| 1 | DESCRIPTION OF ITEMS |
| 2 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell, bell push etc and removing material for taking credit (credit for material should be made as per condition sepretly) and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified. |
| 3 | Taking Down Switches, Socket, ceiling roses, pendants, regulators, sockets, holder, bell, bell push etc any type. All as specified and direct. |
| 4 | M&L for Point wiring for one light point/fan/bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in and including concealed non metalic rigid PVC conduit medium grade size 20 mm dia or higher with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box for Piano type wiring or metal flush box for modular wiring of required size & as directed & 3 mm thick plastic laminated sheet for piano type wiring or cover plate for with frame modular type, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified. |
| 5 | M&L for Point wiring for one light point controlled by Two way switches with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in and including concealed non metalic rigid PVC conduit medium grade size 20 mm dia or higher with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box for Piano type wiring or metal flush box for modular wiring of required size & as directed & 3 mm thick plastic laminated sheet for piano type wiring or cover plate for with frame modular type,including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified. |
| 6 | All as per srl item No-4 here in above but Point wiring for one 3 pin 5/15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 2.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit. |
| 7 | All as per srl item No-4 here in above but Point wiring for one 3 pin 15 Amps socket outlet independent with 4 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 4 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit. |
| 8 | All as per srl item -4 here in above but Point wiring for for one 5A socket outlet on the same board with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit controlled by one switch |
| 9 | M&L for Point wiring for one light point/fan/bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in PVC casing & caping of size width 25 mm X hight 16 mm or higher with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size & as directed & 3 mm thick plastic laminated sheet,including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified. |
| 10 | M&L for Point wiring for one 3 pin socket outlet, 5 A Same Board with other switches, with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in PVC casing & caping of size width 25 mm X hight 16 mm or higher with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size & as directed & 3 mm thick plastic laminated sheet,including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified. |
| 11 | M&L for Point wiring for one 3 pin socket outlet, 5 A/15A Independent, with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 2.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in PVC casing & caping of size width 25 mm X hight 16 mm or higher with combination PVC box of 15 A switch socket complete all fittings (ISI Marked) or controlled by one switch including CI/MS sunk box of required size & as directed & 3 mm thick plastic laminated sheet,including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified. |
| 12 | M&L for Point wiring for one light point/fan/bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in Existing Conduite controlled by one switch including CI/MS sunk box for Piano type wiring or metal flush box for modular wiring of required size & as directed & 3 mm thick plastic laminated sheet for piano type wiring or cover plate for with frame modular type, including cutting chases (if Requried) to wall making good the disturbed surfaces to match with the existing specification complete all as specified. |
| 13 | M&L for Point wiring in repairs one 3 pin socket outlet, 5 A Same Board with other switches, with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in Existing Conduite controlled by one switch including CI/MS sunk box for Piano type wiring or metal flush box for modular wiring of required size & as directed & 3 mm thick plastic laminated sheet for piano type wiring or cover plate for with frame modular type, including cutting chases (if Requried) to wall making good the disturbed surfaces to match with the existing specification complete all as specified. |
| 14 | M&L for Point wiring for one 3 pin socket outlet, 5 A/15A Independent, with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 2.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in Existing Conduite controlled by one switch including CI/MS sunk box for Piano type wiring or metal flush box for modular wiring of required size & as directed & 3 mm thick plastic laminated sheet for piano type wiring or cover plate for with frame modular type, including cutting chases (if Requried) to wall making good the disturbed surfaces to match with the existing specification complete all as specified. |
| 15 | S&F in repairs submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 4 Sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 4 Sqmm as earth lead in & including concealed PVC conduit medium grade 20 mm dia or Higher cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed. |
| 16 | S&F in repairs submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 4 Sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 4 Sqmm as earth lead but in existing concealed conduit . |
| 17 | S&F in repairs submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 6 Sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 6 Sqmm as earth lead in & including concealed PVC conduit medium grade 20 mm dia or Higher cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed. |
| 18 | S&F in repairs submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 6 Sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 6 Sqmm as earth lead but in existing concealed conduit . |
| 19 | S&F switch piano flush button single pole one way 5/6 amps 240 volts. |
| 20 | S&F switch piano type single pole two way 1 module 6 amps 240 volts. |
| 21 | S&F switch piano flush button single pole one way 15/16 amps 230 Volts. |
| 22 | S&F socket 5 amps 5 pin flush type, 230 volts. |
| 23 | S&F socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts. |
| 24 | S&F bell push AC SP 240 volts flush type 5/6 Amps, single pole one way complete as all specified and directed. |
| 25 | S&F ceiling rose surface bakelite 3 terminals. |
| 26 | S&F Lamp holder insulated body with back plate for dome batten fittings. |
| 27 | S&F Electronic fan regulator stepped type,two module with five step 240 volts,100Watt suitable for 1200/1400 mm sweep AC ceiling fan complete, all as directed by Engineer in charge. |
| 28 | S&F switch modular type single pole one way 1 module 6 amps 240 volts. Sample approved by GE or as per exsisting at site, all as specified and directed by Engr-in- Charge. |
| 29 | S&F of switch modular type single pole two way 1 module 6 amps 240 volts. |
| 30 | S&F switch modular type one way 1 module 16 amps 230 Volts. Sample approved by GE or as per exsisting at site, all as specified and directed by Engr-in- Charge. |
| 31 | S&F socket 6 amps modular type 2/3 pin combined 2 module , 230 volts.Sample approved by GE or as per exsisting at site, all as specified and directed by Engr-in- Charge. |
| 32 | S&F socket modular type , 2/3 pin, 6 and 16 amps combined 2 module, 230 volts. Sample approved by GE or as per exsisting at site, all as specified and directed by Engr-in- Charge. |
| 33 | S&F Modular type Electronic fan regulator stepped type,two module with five step 240 volts,100Watt suitable for 1200/1400 mm sweep AC ceiling fan complete, Sample approved by GE or as per exsisting at site, all as specified and directed by Engr-in- Charge. |
| 34 | S&F bell push AC SP 240 volts Modular type 5/6 Amps, single pole one way complete as all specified and directed. Sample approved by GE or as per exsisting at site, all as specified and directed by Engr-in- Charge. |
| 35 | S&F bell electric multi music type / AC SP 240 Volts Complete all as specified and directed. |
| 36 | S&F in repairs Tube light fitting integrated type suitable for LED 20 W(4 feet) efficacy min 100 lumens/watt, indoor decorative LED batten complete with Aluminium housing with all accessories pre wired and making connection with cord flexible copper cable of suitable size from ceiling rose to PVC connection to light fitting complete all as specified and directed. |
| 37 | S&F in repairs Tube light fitting integrated type suitable for LED 10 W (2 feet) efficacy min 100 lumens/watt, indoor decorative LED batten complete with Aluminium housing with all accessories pre wired and making connection with cord flexible copper cable of suitable size from ceiling rose to PVC connection to light fitting complete all as specified and directed. |
| 38 | S&F in repairs LED bulk head fitting with opal diffuser min 10/12 Watt, 6500 K, IP-65, with Aluminium housing of efficient heat dissipation and integrated electronic driver with surge protection and high voltage protection completewith all accessories pre wired and making connection with cord flexible copper cable of suitable size from ceiling rose to PVC connection to light fitting complete all as specified and directed. |
| 39 | S&F in repairs LED light fitting recess mounted min 32/36 Watt, 6500 K 2' x 2' with all accessories suitable for amstrong/grid/POP ceiling complete with integrated electronic driver and making electrical connection properly with pre wired and making connection with cord flexible copper cable of suitable size from ceiling rose to PVC connection to light fitting complete all as specified and directed. |
| 40 | S&F in repairs LED light fitting recess mounted min 10 Watt, 6000 K Round/Square Panel with all accessories suitable for exsisting cut in amstrong/grid/POP ceiling complete with integrated electronic driver and making electrical connection properly all as directed. |
| 41 | S&F in repairs Decorative wall light fixture made of polycarbonate, including 9 W LED Bulb (White/Warm) complete all as specified and directed and making electrical connection properly all as directed. |
| 42 | S&F 5/15 A Switch Socket Combination of PVC Box with Plug top of 15 Amp as per directed by engineer in charge. |
| 43 | S&F in repairs LED Bulb 9 W all as specified and directed. |
| 44 | S&F in repairs LED Bulb 12 Inverter type W all as specified and directed. |
| 45 | S&F in repairs Decorative Gate Light made up of high grade unbreakable ploycarbonate material Globe type of dia min 200 mm and including 9/10 w LED Lamp including fixing of GI pipe of suitable dia (if requried), any mm long light grade, partly embedded on column of gate or wall with fixing arrangement complete and making electrical connection complete all as spfd. |
| 46 | S&F in repairs LED post top lantern 35 Watt warm white/white made in die cast aluminium housing with decorative clear opal acrylic diffuser and IP-65 protection including fixing of GI pipe of suitable dia dia, 300 mm long light grade, partly embedded on column of gate with fixing arrangement complete and making electrical connection complete all as spfd. |
| 47 | S&F in repairs LED street light fitting 60 Watt 230 V AC, in multiple optics,Outdoor type with high pressure die cast aluminum housing, IP-65, with 4 KV inbuild surge protection driver and heat resistant complete with driver, fixing the same by GI pipe medium grade minimum 25 mm dia bore pipe with two nos FI clamps of 40X4 mm duly painted and suitable size of nut and bolts etc and making poper electric connection with three core flexible copper wire complete all as specified and directed. |
| 48 | S&F in repairs modular type 3/4 module power unit with 16 Amp plugtop Box with sheet steel enclosure MCB Combo plug and socket complete with one SP MCB 20 Amps, 240 Volts. Protection to human shock due to direct or indirect contact as well as provides protection from overload and short circuit faults, all as specifed and direced. |
| 49 | S&F in repairs TPN DB, 4 Way, as per IS-8523, IP-42 protection, universal mounting with 200A copper bus bar with neutral bar, earth bar and cable ties for cable management, top and bottom removable gland plate suitable for MCB TPN as incomer and MCB TPN/MCB as outgoing, with and including provision for MCCB/MCBs & making necessary electrical connection for Incoming & outgoing cables, with copper lugs, crimped with crimping tool |
| 50 | S&F in repairs MCB FP TPN of 63-100 Amp, voltage rating 415 V,10 KA C- curve with connection testing and commisioning. |
| 51 | S&F in repairs sheet metal enclosure MCB distribution board, double door with IP-43 IK-09 protection with metal door single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification . |
| 52 | All as per item No 50 but for 8 way. |
| 53 | All as per item No 50 but for 12 way. |
| 54 | S&F in repairs MCB SP of 6 to 32 Amp rating 240,10 KA C- curve with connection testing and commisioning. |
| 55 | S&F in repairs MCB SPN of 32 Amp rating 240,10 KA C- curve with connection testing and commisioning. |
| 56 | S&F in repairs MCB SPN of 40-63 Amp rating 240,10 KA C- curve MCB with connection testing and commisioning. |
| 57 | Attending complaints of an electrical nature and rectification of faults such as “no light” in buildings/blocks due to short circuits in point wiring, sub-main wiring, DBs, LT distribution panels, etc. The scope of work includes rectifying faults such as decarbonizing connections in LT panels, XLPE cables, and DBs; checking for disconnections; tightening loose connections; and identifying any burning/heating due to overloading in distribution boards. The work also includes restoring the electrical supply and carrying out repair/replacement of short-circuited point wiring or sub-main wiring; repair/replacement of recessed light fittings; and checking and rectifying earth faults/leakage current in water taps, home appliances, building security lights/fittings, etc. The work shall include complete repairs as required by removing connections from the system; rectifying faults in wires, battens, conduits, sunken boxes, junction boxes, main switches, MCBs/DBs, utility light fittings, lamp holders, ceiling/exhaust fans, and other connected fixtures.One-time rectification of a fault will be considered as one job.Internal electrification works shall be carried out with respect to the complaint lodged, including refixing of fittings/fixtures to their original positions after dismantling. Nothing extra shall be paid on this account. The work shall be completed as directed at site to the entire satisfaction of the Engineer-in-Charge.Note: (i) The rate quoted by the tenderer are included dismantiling and refixing the fitting the serviceable wire, MCB, SPN, and TPN after minor repairs. However unserviceable wire, MCB SPN and TPN shall be measured and paid seperately as \\"S&F\\" in respective item of this schedule. |
| 58 | Supply and fix in repairs Single core unsheathed 1100 volts PVC-FRLS insulated wire with copper conductor(multistrand) ISI marked of size 1.5 Sqmm, complete all as specified and directed. |
| 59 | Supply and fix in repairs of Single core unsheathed 1100 volts PVC-FRLS insulated wire with copper conductor(multistrand) ISI marked of size 2.5 Sqmm, complete all as specified and directed. |
| 60 | Supply and fix in repairs Single core unsheathed 1100 volts PVC-FRLS insulated wire with copper conductor(multistrand) ISI marked of size 4.00 Sqmm, complete all as specified and directed. |
| 61 | Supply and fix in repairs of Single core unsheathed 1100 volts PVC-FRLS insulated wire with copper conductor(multistrand) ISI marked of size 6.00 Sqmm, complete all as specified and directed. |
| 62 | Supply & fixing in repair of 1100 volts grade heavy duty cable with PVC insulated aluminiuum conductor served with an inner sheating of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm suspention wire one twin core flat/circular 10sq mm solid conductor. |
| 63 | Taking down Ceiling/Exhaust Fan any Sweep any type ,from the exsisting site and keep safe and under custody and complete cleaning, Oiling ,Greasing , repair to make fan seveciable , bearing and nut washet bolt and clamps of fan and Refixing fan as existing location and connection to celing rose with copper wire twin core complete all as specified and directed. |
| 64 | Taking down LED Light fitting , 2X2 Led Panel, Bulkhead, Bldg secuity light, wall Light, Post top lamp any type, from the exsisting site and keep safe and under custody and complete cleaning, repair to make seveciable by changing driver of existing make(if required) and Refixing the same as existing location and connection to celing rose with copper wire twin core complete all as specified and directed. |
| 65 | Supply and fix in repairs Exhaust fan made of sturdy Engineering Plastic , PVC Body of size 250mm sweep single phase 230 V 50 Hz AC 1400 RPM energy saving, heavy duty motor copper wounded with die cast aluminium rotor mounted on two ball bearing complete with louvrs shutter including making hole of suitable size and making good disturbed surface (including making hole and plasterng, nacessary brickwork and distemparing to match with existing) connecting with 3 core copper cable to ceiling rose. All as specified and directed . Note: Old Unsv Fans shall be deposited to MES store by the contractor. |
| 66 | Supply install and tesing water heater storage type (Geyser) in repairs single phase 230 V, 50 Hz, 5 star energy saving high density PUF insulation tank made of heavy duty mangesium anode rod with steel core to protect enamelled tank from rust & corrosion, vertical installation type 25 Ltr Cap 2000 Watt rated power, incoloy 800 glass coated heating element, inner tank coating of feroglas powder, tank made of ultra thick super cold rolled steel plates, rated pressure 0.8 MPa, IPX4 protection consist of safety valves, thermal cut off, thermostat including connecting up and fixing arrangement on wall including providing hole fastners-04 Nos hot and cold water metallic flexible pipes 15 mm bore of adequate length as provided by OEM or required at site - 02 Nos non return valve 01 No and including necessary plumbing work, complete with intergated shock safe PRCD Plug with all protection features as per OEM design and standard all as specified and directed. Note: Old Unsv Storage tank shall be deposited to MES store by the contractor. |
| 67 | M&L for Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991 or directed by Engineer-in-charge and testing on completion. |
| 68 | Supply and fixing LED street light fitting 45 Watt 230 V AC, in multiple optics,Outdoor type with high pressure die cast aluminum housing, IP-65, with 4 KV inbuild surge protection driver and heat resistant complete with driver, fixing the same by GI pipe medium grade minimum 25 mm dia bore pipe with two nos FI clamps of 40X4 mm duly painted and suitable size of nut and bolts etc and making poper electric connection with three core flexible copper wire complete all as specified and directed. Please Enable Macros to View BoQ information |