| 1 | Supply and stacking cow dung/swine manure at site for preparing compost at site as specified and as directed by Engineer-in-Charge.Note: stack volume shall be reduced by 10% for pavment. |
| 2 | Supply only fertilizer mix of vermi compost, agromeal, neem khali at site as specified and as directed by Engineer-in-Charge |
| 3 | Supply only fertilizer urea at site as specified and as directed by Engineer-in-Charge |
| 4 | Supply only chiorophyriphoes 20% at site as specified and as directed by Engineer-in-Charge |
| 5 | Supply only good/sweet earth at site suitable for agriculture purpose, which should be free from pebbles, stone, weeds etc., for their mount and filling at site as specified and as directed by Engineer-in-Charge.Note: stack volume shall be reduced by 20% for pavment. |
| 6 | Excavation of pit of size 0.75x0.75x0.75m for trees, in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (02 parts of stacked volume of earth after reduction by 20%: 01 part of stacked volume of manure after reduction by 8%) as required and inside coat of Antitermite chemical in pit, flooding with water, dressing including removal of rubbish & surplus earth if any with all leads & lifts, planting of trees and stacking in full and final location as directed by Engineer-in- Charge. Note: (i) Rate of trees shall be paid separately under respective items (ii) Supply only ATT chemical, manure and fertilizer shall be measured and paid under respective items. |
| 7 | Supply only following TREES at site as specified and as directed by Engineer-in-Charge. Note: Height of tress shall be minimum 4 feet measured from ground level :- |
| 8 | Cycus palm |
| 9 | Bottle palm |
| 10 | China palm |
| 11 | Washing tunia palm |
| 12 | Ashok tree |
| 13 | Lime tree |
| 14 | Guava |
| 15 | Mandarin orange |
| 16 | Mango |
| 17 | Bottle brush |
| 18 | Amaltash |
| 19 | Red Gulmohar |
| 20 | Cherry blossom |
| 21 | Jacranda(jacaranda mimosifolia) |
| 22 | Blue Gulmohar |
| 23 | Bouganvila |
| 24 | Kasood(Cassia samea) |
| 25 | Gardening (Rangoon, rosé , jamine, yellow merrygold, Glardia, jeenia, cosmos, gumprina, partula etc.,) |
| 26 | M&L for planting of crotons, hedge plants/sapling Acalypha variegated/Duranta Erecta/Hibiscus red and pink/ carisssa carandas, Ficus (height of plant not less than 75 cm above ground level) of approved species at a spacing not exceeding 60cm C/C including excavation of pit of min dimension 50cmx50cm50cm and removal of excavated earth to outside the MD land, preparation of ground upto 30cm deep and filling with good earth, cow dung, vermi composit and watering etc complete all as specified and directed. |
| 27 | M&L for preparing the soil base for planting grass by ploughing of whole site in ordinary soil upto a depth of 30 cm, removing all unwanted materials such as stones, weeds, tree roots etc which are not suitable for healthy growth of grass, levelling the base to required slopes and levels, supplying and spreading 02 parts of sand, 01 Part of bio fertiliser and one part of red loamy virgin soil for growth of grass to an average thickness of 300mm including mixing vermin compost etc., to improve the fertility of the soil in the required proportion and finally preparing the soil base suitable for planting carpet grass etc. including remoal surplus debris outside MoD land, complete all as specified and as directed. |
| 28 | M&L for planting ever green grass of natural Korean/mexican feather carpet grass of approved pattern over the prepared base lawn/carpet area with good earth over the prepared base including watering, removing the weeds or any other vegetation, mixing the manure from time to time and pesticides as required for healthy growth as per standard gardening practice complete all as specified and directed. |
| 29 | Maintinance of plants/trees planted as per item No 7 above for ensuring survival and growth for a period of 3 years or height of tree 6' which is earlier including removing of weeds, watering, spraying of pastisides, adding manure etc., complete all as specified and as directed.Note:-Water will be supplied by MES at lorry filling point.Necessary vehicle for transporting water from lorry filling point/pump house to location where trees are planted will be made by contractor on his own arrangement. |
| 30 | Maintinance of plants/crotons/hedge plants planted as per item No 8 & 9 above by watering, taking out weeds, manuring the organic manure at regular intervals, using chemical fertilizers, spraying pesticides etc. required healty growth, trimming branches/grass to maintain proper shape etc., all as per standard gardening practice for a period of 3 years complete all as specified and as directed. |
| 31 | Maintinance of Grass planted as per item No 11 above by watering, taking out weeds, manuring the organic manure at regular intervals, using chemical fertilizers, spraying pesticides etc. required healthy growth, trimming branches/grass to maintain proper shape etc. all as per standard gardening practice for a period of 3 years complete all as specified and as directed. |
| 32 | NOTE FOR ITEM NO 12 TO 14 ABOVE :-(i) For this purpose sufficient number of gardeners shall be deployed by the contractor.(ii) Water shall be supplied by MES free of cost for maintaining the grass and plants(iii) Water will be supplied by MES at lorry filling point. Necessary vehicle for transporting water from lorry filling point/pump house to location where trees are planted will be made by contractor on his own arrangement. |
| 33 | Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out, in hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, and removing surplus soil to a distance not exceeding 50 m and depositing where directed and making good the disturbed surface complete all as specified and as directed by Engineer-in-Charge. |
| 34 | M&L for PCC 1:3:6, type C-2, using 40 mm graded stone aggregate as in foundation/bed concrete etc., complete all as specified and directed |
| 35 | S&F mild steel work as in angle iron posts & struts in fencing including cutting top to shape as directed drilling holes, notching for wire etc., flat iron fillets (for securing wire mesh etc., ) and similar works conforming to Grade E.165 (Fe 290) complete all as specified & directed. |
| 36 | S&F for mild steel screwed bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut, Length of bolt exceeding 5cm long but not exceeding 10cm long and dia of neck 11mm to 15 mm complete all as specified and directed. |
| 37 | S&F galvanised Chain link fencing PVC coated of 50x50mm mesh size and made of 3mm GI wire, streched and fixed to fencing post all as specified and directed by Engineer-in-Charge. |
| 38 | S&F 10 mm dia mild steel round bars as in tie bars fixed to fencing posts including cut to length bent to shape, welding of bars at spots as directed and other similar works conforming to Grade E-165 (Fe 290 ) complete all as specified & directed. |
| 39 | M&L for prepartion new or previously untreated surface of steel, any description over 10cm width or girth and applying two coat of synhetic enamel pain over a coat of red oxide primer complete all as specified and directed. |
| 40 | Excavation over area not exceeding 1.5m deep and getting out in loose soil complete all as specified and directed |
| 41 | Removing surplus excavated soil to a distance exceeding 50 metre but not exceeding 200 metre and depositing where directed at a level not exceeding 1.5 m above the stafrting point complete all as specified and directed |
| 42 | S&F cast iron garden bench having seating capacity of 4 seater, Cast iron side frame, Mild steel seat with 2 mm thick steel pipe, Mild steel back rest with 2mm thick steel pipe, all fiunished with powder coating, (Total height-900mm (+/-200mm), seat height-425mm (+/-100mm),width-1500mm (+/-100mm) and weight bearing capacity of 160 to 200 kg.) complete all as specified and directed. |
| 43 | S&F Metal & fibre body playground slide for kids, out door play ground, including necessary arrangement for making functionable complete all as directed by Engineer in Charge. |
| 44 | S&F Metal body swing for kids, out door play grond, including necessary arrangement for making functionable complete all as directed by Engineer in Charge. |
| 45 | S&F Metal body seesaw for kids, out door play ground including necessary arrangement for making functionable complete all as directed by Engineer in Charge. |
| 46 | Excavation in trenches not exceeding 1.5 mtr in wide and not exceeding 1.5 mtr in depth for laying of pipes/underground cable and getting out in soft/loose soil complete all as specified and directed. |
| 47 | Excavation in trenches not exceeding 1.5 mtr in wide and not exceeding 1.5 mtr in depth for laying of pipes/underground cable and getting out in Hard/dense soil complete all as specified and directed. |
| 48 | Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed. |
| 49 | Removing of excavted soil to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 50 | Supply and lay double wall corrugated (DWC) HDPE pipe, 40 mm bore, as per IS:16205 including necessary couplers and bend for cable protection, laid in trenches complete all as specified and directed. |
| 51 | Supply, lay, test and commissioning of LT UG , XLPE insulated, heavy duty, 1100V grade electric cable with aluminum conductor, 10 sqmm 2 core served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipe, making all connections with and including provision of necessary glands, lugs, bushing etc., as required complete all as specified and as directed by Engineer-in-Charge. |
| 52 | Supply, lay, test and commissioning of XLPE insulated, heavy duty, 1100V grade electric cable flat or circular with stranded aluminum conductor, 6 sqmm 2 core served with an PVC inner sheathed, in service connection fixed on wall/trenches by means of saddle, nut and bolts complete all as specified and directed |
| 53 | Supply and laying XLPE insulated, heavy duty, 1100 volts grade electric cable with stranded copper conductor, 1.5 sqmm 3 core, PVC inner sheathed cable passing through and including PVC pipe 25 mm, laid in trenches or fixed on wall by saddling complete all as specified and directed.Note: (i) Rate Including the PVC conduit 20 mm with all fitting & saddling as required(ii) Earth work will be paid separately with their respective item |
| 54 | Supply and laying GI tubing, 40mm bore, light grade for cable protection laid in trenches/under road/path etc., complete all as specified and directed by Engr-in-charge.Note: (Ii) Earth work will be paid separately with their respective item |
| 55 | M&L for PCC 1:4:8, type C-2, 1:4:8, using 40 mm grade stone aggregate as in foundation of poles/trenches and coping of poles/complete all as specified. |
| 56 | M&L for cutting the existing bituminous road / hard standing to size not exceeding 45cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete in 1:3:6, type C1, using 20mm graded stone aggregate complete all as specified and directed by Engineer-in-Charge.Note : Price of GI Pipe will be measured and paid separately in the relevant items of schedule. |
| 57 | S&F LED Bollard light with cast aluminium housing and polymer diffuser 9 watt LED, IP65 protection, LED and in built driver suitable for garden and pathway lighting including copper cable connection of suitable size complete all as specified and as directed by Engr-in-charge.Make- Shakti cat no-SZPGBMX009-C or its techno-commercial equivalent.Note : Necessary grouting with PCC 1:3:6 for foundation and cooping of size 25 x 20 cm for fixing of new bollards (above which light to be fixed) shall deemed to be included rate quoted by the contractor. Please Enable Macros to View BoQ information |
| 58 | S&F LED Bollard light with cast aluminium housing and polymer diffuser 9 watt LED, IP65 protection, LED and in built driver suitable for garden and pathway lighting including copper cable connection of suitable size complete all as specified and as directed by Engr-in-charge.Make- Shakti cat no-SZPGBMX009-C or its techno-commercial equivalent.Note : Necessary grouting with PCC 1:3:6 for foundation and cooping of size 25 x 20 cm for fixing of new bollards (above which light to be fixed) shall deemed to be included rate quoted by the contractor. Please Enable Macros to View BoQ information |