| 1 | Electrification |
| 2 | OD262734/2025-2026:Supply and Installation 1.5 TR invertor type Split Air- conditioner unit conforming to IS 1391(Part2/92) suitable foroperation on 230V+/- 10% 50 Hz single phase AC supply fitted with hermetically sealed compressoroperating on R 32 / CFC Refrigerant gas with copper condensing and evaporating unit capable for cooling aircirculation and filtering etc. including refrigerant copper piping with insulation up to 5 Metre or required lengthmicroprocessor control with chord less remote control and providing wall mounting stand for the outdoorunit etc (With 1 year on product, 5 years on compressor warranty period). Blue star/Daikin/Carrier |
| 3 | OD262735/2025-2026:Supply and fixing 4 KVA voltage stabilizer V guard or equivalent with input voltage 170 to 270 V and output voltage range of 210 to 230 V with overload protection (cut off) time delay, indicators,and chord wire etc.as required |
| 4 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 5 | 1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 6 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 7 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 8 | 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator |
| 9 | 90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket |
| 10 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 11 | 1.17.5:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm |
| 12 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 13 | 1.17.23:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 4 sq. mm |
| 14 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 15 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 16 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 17 | OD336817/2025-2026:Supply and fixing of Led Recessed mounted ( 2X2 )600*600 mm Luminaire having power consumption not more than 30W and light output not less than 3600 Lumens with System efficacy> 120 Lumen/Watt ,UGR<19. Luminaire Housing Shall be made from single piece CRCA body without welding. The Luminaire should be having minimum 50000 Burning hours(L70B50) with CRI ≥80, SDCM<5 and Co-related color temperature (CCT) of 6500K.The luminaire must have 4KV surge protection integrated in driver,Ripple<5%, PF≥0.95, Total harmonic distortion THD≤10%,EMI/EMC Compliant, Operating voltage range 140-270V with High voltage cutoff@325 ± 15V with Auto restart feature. Luminaire and driver shall be separately BIS approved of same make ( Philips RC380B LED36S/equivalent). LM80,LM79 ,Type Test certificate and Bis certificate need to be submitted prior for approvals. Chip make Cree/Osram/lumilled/Nichea complete with all accessories in the existing opening of false ceiling, giving connections with the existing wire etc., as required. |
| 18 | OD336829/2025-2026: Supply and installation and testing of recessed luminaire 2000 lumen 20W square(1X1) fittings made of diecast aluminium, having efficacy not less than 100 l/w, pf greater than 0.95,UGR<19, THD less than or equal to 10%, input voltage 160-300V . The driver shall be plug in type for easy maintenance . The driver and luminaire shall be of same make, Chip make Cree/Osram/lumilled/Nichea complete with all accessories in the existing opening of false ceiling, giving connections with the existing wire etc., as required. |
| 19 | OD336910/2025-2026:Supply Conveyance, installation, testing and commissioning of surface/recess mounting round down light fittings of 18 W 3000K CCT, efficacy 100lm/W directly on ceiling including giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required. (Crompton PROXIMA R /equivalent) Please Enable Macros to View BoQ information |