| 1 | Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. (SOR-8-7-2) | Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. (SOR-8-7-2) |
| 2 | Dismantling the existing overhead line including G.I. wires of all sizes without damaging & making the coils in suitable sizes. (SOR-8-7-3) | Dismantling the existing overhead line including G.I. wires of all sizes without damaging & making the coils in suitable sizes. (SOR-8-7-3) |
| 3 | Dismantling the existing lightening arrestor set, insulator from DP structure complete. (SOR-8-7-4) | Dismantling the existing lightening arrestor set, insulator from DP structure complete. (SOR-8-7-4) |
| 4 | Erecting rolled steel joist (girder) pole 200 x 100 mm. (25.9 kg/m) with provided base plate in provided foundation as per specification no. OH-PL/RSJ (SOR-8-1-10) (2021-22) | Erecting rolled steel joist (girder) pole 200 x 100 mm. (25.9 kg/m) with provided base plate in provided foundation as per specification no. OH-PL/RSJ (SOR-8-1-10) (2021-22) |
| 5 | Making Cement concrete foundation including excavation (60 x 60 x 150)cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45)cm /45cm dia. x 45cm height plinth duly plastered, with necessary curing and finishing complete. (above 6m to 9m poles) (SOR-16-3-3) | Making Cement concrete foundation including excavation (60 x 60 x 150)cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45)cm /45cm dia. x 45cm height plinth duly plastered, with necessary curing and finishing complete. (above 6m to 9m poles) (SOR-16-3-3) |
| 6 | Supplying and erectingG.I. stay set for poles, including loop insulators at in accessible height with anchor plate 300x300x6mm., straining screws,G.l. stay wire7/10SWG,G.l.stayrod 20mmx1.8m length andpole clamps duly erected in provided cement concrete foundation complete. (SOR-8-6-1) | Supplying and erectingG.I. stay set for poles, including loop insulators at in accessible height with anchor plate 300x300x6mm., straining screws,G.l. stay wire7/10SWG,G.l.stayrod 20mmx1.8m length andpole clamps duly erected in provided cement concrete foundation complete. (SOR-8-6-1) |
| 7 | Making Cement concrete foundation including excavation (60 x 60 x 150)cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay) (SOR-16-3-6) | Making Cement concrete foundation including excavation (60 x 60 x 150)cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay) (SOR-16-3-6) |
| 8 | Supplying and erecting C type (half) clamps for pole made from 50x10mm flatfor fixing cross arms by means of 15 mm bolts and nuts painted with one coat of red oxide and two coats of aluminium paint complete. (SOR-8-6-12) | Supplying and erecting C type (half) clamps for pole made from 50x10mm flatfor fixing cross arms by means of 15 mm bolts and nuts painted with one coat of red oxide and two coats of aluminium paint complete. (SOR-8-6-12) |
| 9 | Supplying & erecting MS pole bracket for guarding/LT OH line, fabricated from angle iron 50x50x6mm and 1100mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT (SOR-8-3-2) | Supplying & erecting MS pole bracket for guarding/LT OH line, fabricated from angle iron 50x50x6mm and 1100mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT (SOR-8-3-2) |
| 10 | Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. (SOR-8-7-2) | Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. (SOR-8-7-2) |
| 11 | Dismantling the existing overhead line including G.I. wires of all sizes without damaging & making the coils in suitable sizes. (SOR-8-7-3) | Dismantling the existing overhead line including G.I. wires of all sizes without damaging & making the coils in suitable sizes. (SOR-8-7-3) |
| 12 | Erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with provided base plate in provided foundation as per specification no. OH-PL/RSJ ((SOR-8-1-12) 2021-22)) | Erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with provided base plate in provided foundation as per specification no. OH-PL/RSJ ((SOR-8-1-12) 2021-22)) |
| 13 | Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles) (SOR-16-3-3) | Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles) (SOR-16-3-3) |
| 14 | Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay).(SOR-16-3-6) | Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay).(SOR-16-3-6) |
| 15 | Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6mm., straining screws, G.l. stay wire 7/10 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete.(SOR-8-6-1) | Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6mm., straining screws, G.l. stay wire 7/10 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete.(SOR-8-6-1) |
| 16 | Supplying and erecting C type (half) clamps for pole made from 50x10mm flat for fixing cross arms by means of 15mm bolts and nuts painted with one coat of red oxide and two coats of aluminium paint complete. (SOR-8-6-12) | Supplying and erecting C type (half) clamps for pole made from 50x10mm flat for fixing cross arms by means of 15mm bolts and nuts painted with one coat of red oxide and two coats of aluminium paint complete. (SOR-8-6-12) |
| 17 | Supplying & erecting MS pole bracket for guarding/LT OH line, fabricated from angle iron 50x50x6mm and 1100mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT (SOR-8-3-2) | Supplying & erecting MS pole bracket for guarding/LT OH line, fabricated from angle iron 50x50x6mm and 1100mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT (SOR-8-3-2) |
| 18 | Supplying & erecting MS pole bracket for LT OH conductor fabricated from 65x65x6 mm section, 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. OH PL/BKT (SOR-8-3-6) | Supplying & erecting MS pole bracket for LT OH conductor fabricated from 65x65x6 mm section, 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. OH PL/BKT (SOR-8-3-6) |
| 19 | Supplying and erecting pin type LT medium insulator 100mmx 62mm dia. with suitable G.l. spindle, nut, bolts complete. (SOR-8-5-1) | Supplying and erecting pin type LT medium insulator 100mmx 62mm dia. with suitable G.l. spindle, nut, bolts complete. (SOR-8-5-1) |
| 20 | Suplying & erecting hard drawn G.I. wire 8 SWG complete erected for overhead line with proper size of G.I. wire for binding with jumpering etc. (PO. No. 5700206858 dated 11.05.2023) | Suplying & erecting hard drawn G.I. wire 8 SWG complete erected for overhead line with proper size of G.I. wire for binding with jumpering etc. (PO. No. 5700206858 dated 11.05.2023) |
| 21 | Erecting ACSR conductor of size 6/1-3.60mm complete. (Ferret) (171.3 kg/km) as per specification no.OH-CON/ACSR ((SOR-8-5-8) 2021-22)) | Erecting ACSR conductor of size 6/1-3.60mm complete. (Ferret) (171.3 kg/km) as per specification no.OH-CON/ACSR ((SOR-8-5-8) 2021-22)) |
| 22 | Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results as per specification no. EA-EP (SOR-9-1-4) | Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results as per specification no. EA-EP (SOR-9-1-4) |