| 1 | Earthwork in excavation in foundation trenches in ordinary soil ( vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/l Extra for earthwork in hard soil as per specification and direction of E/I (Vide classification of soil item_B) |
| 2 | Filling In foundation trenches and plinth In layers not exceeding 150 mm. thick well watered, rammed, fully compacted and flne dressed with earth obtained from excavation of foundation , trenches within a lead of 50 M and lift of 1.5M all complete as per building specification anddirection of Ell (Mode of measurement compacted volume). |
| 3 | providIng coarse clean sand In filling in foundation trenches or In plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour. royalty and taxes all complete as per building specification and direction of Ell (Mode of measurement compacted volume). |
| 4 | Supplying chemical emulsion in sealed containers including delivery as specified. |
| 5 | Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 6 | With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. |
| 7 | CONCRETE WORK |
| 8 | Providing P.C.C. M-75 with nominal mix of (1: 4:8) in foundation with approved quality of stone metal grade - III ( 50 mm to 25 mm) size clean coarse sand -chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3, incIuding Screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as perbuilding specification and dIrection of Engineer-ln-charge. |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : |
| 10 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stoneaggregate 20 mm nominal size). |
| 11 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor,etc., up to floor five level, excluding the cost of centering, shuttering and finishing: |
| 12 | 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 13 | SUB-HEAD 5.0 - REINFORCED CEMENT CONCRETE |
| 14 | JSOR ITEMS (Steel Reinforcement) |
| 15 | Providing Tor steel reinforcement of 8mm. dia rods as per approved design and drawing -do- -do- TMT Fe 500 (Only valid for SAIL & TATA Steel, JSPL, Electro Steel Ltd. And Vizal Steel) |
| 16 | Providing Tor steel reinforcement of 10mm,12mm & 16 mm. dia bars as per approved designand drawing -do- -do- |
| 17 | a) 10 mm (TMT coiI Fe 500) {Only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel steels Ltd.Bokaro and Vizag (RINL)} |
| 18 | b) 12 mm (TMT coiI Fe 500) {Only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel steels Ltd.Bokaro and Vizag (RINL)} |
| 19 | c) 16 mm (TMT coiI Fe 500) {Only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel steels Ltd.Bokaro and Vizag (RINL)} |
| 20 | Providing Tor steel, reinforcement of 20mm, 25mm, 28mm, 32mm dia bars as per approveddesign and drawing-do- -do- |
| 21 | 20/25 mm dia,TMT bar Fe 5OO {Only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel steels Ltd.Bokaro and Vizag (RINL)} |
| 22 | FORM WORK |
| 23 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 24 | Foundations, footings, bases of columns, etc. for mass concrete |
| 25 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 26 | Suspended floors, roofs, landings, balconies and access platform |
| 27 | Shelves (Cast in situ) |
| 28 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 29 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 30 | Extra for shuttering in circular work (20% of respective centering and shuttering items) |
| 31 | Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, stringcourses, bands, copings, bed plates, anchor blocks and the like |
| 32 | Edges of slabs and breaks in floors and walls |
| 33 | Cornices and mouldings |
| 34 | Weather shade, Chajjas, corbels etc., including edges |
| 35 | DESIGN MIX CONCRETE |
| 36 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 37 | All works upto plinth level |
| 38 | Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 39 | All works above plinth level upto floor V level |
| 40 | Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 41 | Providing and fixing in position 12 mm thick bitumen impregnated fiber board conforming to IS: 1838, including cost of primer, sealing compound Grade-A in expansion joints. |
| 42 | MASONARY WORK |
| 43 | Providing designation 75 A brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 Including providing 10 mm thick mortar joints. cost of screentng materials raking out joints to 15mm depth, curing, taxes and royalty all complete asper building specification and direction of E/l. |
| 44 | Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry with 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar allcomplete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). (correction slip no-1 (13-10-2021) |
| 45 | FLY ASH BRICK WORK |
| 46 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894- 1990 (9\\"x4.5\\"x3\\" in C.M (1: 6) in super structure with approved quality of clean coarse sand ofF.M. 2 to 2.5 including providing 10 mm thick /mortar joints, cost of screening materials, raking out Joints to 15mm depth, curing, taxes and royalty all complete as per building specification anddirection of E/l. |
| 47 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars atevery third course of halfbrick masonry. |
| 48 | Half brick masonry with non modular fly ash bricks of class designation 10, conforming to IS : 12894, in super structure above plinth and upto floor V level. |
| 49 | Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 50 | SUB-HEAD 8.0 MARBLE W O R K |
| 51 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high glossfinish etc. complete at all levels. |
| 52 | Granite of any colour and shade |
| 53 | Area of slab over 0.50 Sqm |
| 54 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 55 | Granite work. |
| 56 | Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. |
| 57 | SUB-HEAD 9.0 - WOOD & PVC WORK |
| 58 | Supplying, fitting and fixing 35mm thick solid core type non-decorative double leaf flush shutters in doors and windows with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneered of standard make with oxidised iron fittings -- do --- |
| 59 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 60 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edgesof flush door shutters (over all area of door shutter to be measured). |
| 61 | Providing and fixing aluminium sliding door bolts, ISI marked anodised anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 62 | 250x16 mm |
| 63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less thangrade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 64 | 150x10 mm |
| 65 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessaryscrews etc. complete : |
| 66 | 125mm |
| 67 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade,with necessary screws etc. complete. |
| 68 | single rubber stoper |
| 69 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape. colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367: Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at al comers, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. |
| 70 | Wire mesh/Glazing of plain/ toughened/ laminated/ double glass unit with/without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shallbe paid separately. |
| 71 | Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for: (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 (ii)Sites with structure height more than 20m for all wind speeds |
| 72 | Two track two panels sliding window with Aluminium channelfor roller track, wool pile, nylon rollers with SS 304 body. |
| 73 | Using R3 series with frame (55 mm & above) x (40 mm & above) & sash (30 mm & above) x (55 |
| 74 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rollingshutters. |
| 75 | 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 76 | Providing and fixing ball bearing for rolling shutters. |
| 77 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 78 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 79 | VITRIFIED FLOOR TILES |
| 80 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. |
| 81 | Size of Tile 600x600 mm |
| 82 | STONE FLOORING |
| 83 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment ofmatching shade complete. |
| 84 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), including grouting the joints with white cement and matching pigmentsetc., complete. |
| 85 | Providing and laying 25mm thick kotah stone slab flooring of approved size, texture and colour over 19mm. thick base of lime morter (1:1:1) (lime putty:surkhi:coarse sand) laid over and Jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandium stone including cost of curing, taxes and royalty all complete as per building speclflcationand direction of Ell. |
| 86 | iv) 600X600 mm Size |
| 87 | Providing and laying 25mm thick kotah stone tiles In risers of steps, skirting, and pillars of approved size, texture and colour laid over 12mm. thick cement mortar (1:3) and joined with grey cement slurry mixed with pigment to match the shade of the slab including rubbing to granolilthicfinish with approved quality -do- |
| 88 | PLASTER WORK |
| 89 | Providing 12mm. cement plaster (1:3) with clean coarse sand of F.M 1.5 Including screening, curing with all leads and lifts of water scaffolding taxes and royalty all complete as per buildingspecification and direction of E/l. |
| 90 | Providing 12mm. Thick cement plaster (1:6) -do- |
| 91 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 92 | 1:6 (1 cement : 6 fine sand) |
| 93 | CEMENT PLASTER IN TWO COATS |
| 94 | Providing 19 mm thick water proofing cement plaster (1:3)-do |
| 95 | 6 MM CEMENT PLASTER |
| 96 | Providing 6mm thick cement (1:4) in ceiling with clean corse sand of FM. 1.5 do |
| 97 | Making 6x6mm grooves in plaster surface over walls truely horizontal or vertical as Specified at regular Intervals, at all heights including cleaning, finishing, scaffolding and curing with all leads and lifts of water all complete as per building specification and direction of E/l |
| 98 | Finishing walls with textured exterior paint of required shade : |
| 99 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) overand including priming coat of exterior primer applied @ 2.20kg/ 10 sqm |
| 100 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 101 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat ofexterior primer applied @ 2.20 kg/ 10 sqm). |
| 102 | Providing and applying white cement based putty of average thickness 1 mm, of approved brandand manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 103 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : |
| 104 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 105 | Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coatswherever required to achieve even shade and colour. |
| 106 | Two coats. |
| 107 | Applying priming coats with primer of approved brand and manufacture, having low VOC(Volatile Organic Compound ) content. |
| 108 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 109 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid forseparately) : |
| 110 | For fixed portion |
| 111 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 112 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): |
| 113 | With float glass panes of 5.50 mm thickness |
| 114 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings anddirection of Engineer-in-charge complete. |
| 115 | Upto 5mm depth and 5 mm width |
| 116 | SUNKEN PORTIONS |
| 117 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 118 | Water proofing for Old and New Roof Slab:- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with, brush, roller or spray for water proofing coating as per manufacturer specifications with following steps: (a surface preparation-Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt Ltd /MYK Schomberg/Dr Fixit/Fosroc or equivallent Providing and reparing of all comers and joints such as those between the parapet wall and the roof slab etc shall be chamfered with 150 mm X 150 mm fillet of mortar (Cement: sand-1:4) admixed with acrylic polymer of Sika Fosroc/MYK Schomberg Fixit or equivalent. Before chamfering a prime coat shall be given with the slurry ofacrylic polymer. Repairing surface irregularities, damaged concrete in base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete. (b)1st Coat Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roiler After 1st coat of application, 45 gsm of Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg / Samt/coat.For the purpose ofmeasurement the entire treated surface will be measured.\\" (c) 2nd Coat-To apply the 2nd coat of two component acrylic modified, ready to use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface 2nd coat should be applied @0.7 kg/Samticoat For the purpose of measurement the entire treated surface will be measured After three days of drying the 2nd coat, the rail water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of EIC. The waterproof coating to be protected from damage before screed over it. Waterproofing Brand- Sika Topseal 109hi/Fosroc Brushbond RFX/Dr Foxit Pidiffin 2K/MYK |
| 119 | Covering of treated surface with PCC :- Providing 50 mm thick Cement Concrete M20(1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and cleaned sand of F.M 2.5 to 3 including screening,shuttering and mixing cement concrete in mixer with admixture of integral water proofing and placing in position,striking curing,taxexand royality all complete as per building specifiction and direction of Ell.Panels that has been left should be casted next day.There should be 6 mm gap between Panels .Brand-Sika-P\astocrate plus, MYK proof WP 1O,Fosroc-Conplast X4211 C,Dr.fixit Pidiproof LW+ or Equivalent . |
| 120 | 5.12.8. Providing and filling of 6 mm thick Groove between 25 mm PCC Panels with Polysulphide Sealant (Poring Grade)as per drawings and technical specifications and direction of E in Charge.(with 18% GST) .Brand:-Sika-Polysulphide, Fosroc-Thioflex 600,Dr. Fixit Pidiseal PS(42P),MYKSeal PS or Euivalent |
| 121 | CARRIAGE OF MATERIAL |
| 122 | Local Sand (3 km) |
| 123 | Stone Chipps & stone aggregate (22 km from Chash Bokaro) |
| 124 | Coarse Sand ( 10 km from Chash Bokaro) |
| 125 | Bricks (8 km) |
| 126 | Fly Ash Bricks(8km) |
| 127 | NON-SCHEDULE ITEMS |
| 128 | Providing and fixing of Glass Reinforced Concrete (G.R.C) Wall Cladding Tiles in approved design, size, texture, thickness, pattern and color. The thickness of the tiles should range between 12 to 18 mm (depending on the texture of the tile), allowing variance of ±2 mm in accordance with IS: 1237-1980. The composition of tiles should be '43' Grade White Portland cement, reinforced with Alkali Resistant Glass Fiber and the pigmentation should be done with exterior grade synthetic inorganic iran oxide pigments manufactured by 'BAYFERROX (Germany)' or equivalent. The pigmentation should be homogeneous and in accordance with British Standards BS EN 12878:1999. The other additives should be fine washed graded quartz, super plasticizers and integrated water proofing agents and others. The tiles should be produced with high vibration technology and should have compressive strength equivalent to M-40 Grade@28 days. The top surface of the tilles should be sealed with acrylic lacquer resulting in surface water absorption of tiles, less than 1% and water absorption by 24 hrs immersion method, less than 8%. The tiles should be applied on a plaster of cement mortar 1:3 (1 cement: 3 coarse sand) and the fixing of tiles should be done by 'Unistone' tile adhesive or equivalent as per manufacturer's laying instruction. |
| 129 | ELECTRICAL WORK |
| 130 | Point wiring in PVC conduit, with modular type switch |
| 131 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated |
| 132 | Group C |
| 133 | Circuit wiring in PVC conduit |
| 134 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper |
| 135 | 2 x 1.5 Sq.mm. + 1 x 1.5 Sq.mm. earth wire |
| 136 | 2 x 6 Sq.mm. + 1 x 6 Sq.mm. earth wire |
| 137 | 4 x 10 Sq.mm. + 2 x 6 Sq.mm. earth wire |
| 138 | S/ F Light Plug Point With Modular Type Accessories |
| 139 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, |
| 140 | S/ F Power Plug Point with Modular Type Accessories |
| 141 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, |
| 142 | S/ F 20 Amps SPN MCB Industrial Socket Outlet |
| 143 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal |
| 144 | Power Plug wiring in PVC Conduit (2 x 4 Sq.mm) |
| 145 | Wiring for light/ power plug with 2 x 4 sq. mm FR PVC insulated copper conductor single core cable in |
| 146 | S/ F MS Conduit |
| 147 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessedconduit as required. |
| 148 | 25 mm |
| 149 | 32 mm |
| 150 | S/ F ModulaR Type Electronic Fan Regulator |
| 151 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch boxincluding connections but excluding modular plate etc. as required. |
| 152 | S/ F Modular Boxes, Base & Cover Plate |
| 153 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess etc as required. |
| 154 | 1 or 2 Module (78 mm x 78 mm x 45 mm) |
| 155 | Fixing Louvers Shutters For Exhaust Fan |
| 156 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 157 | S/F SP & N MCB Distribution Board |
| 158 | Supplying and fixing following way SP&N MCB distribution board of steel sheet for 240 volts on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections,phosphatized and powder painted including earthing etc. as required. (But withoutMCB/ RCCB/ Isolator) |
| 159 | 8way, Double door |
| 160 | S/F TP & N MCB Distribution Board |
| 161 | Supplying and fixing following way TP&N MCB distribution board of 415 volts on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator) |
| 162 | 4 Way (4 + 12), Double Door,Horizontal Type |
| 163 | Supplying and fixing following rating, 240, \\"C\\" series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. asrequired. |
| 164 | 6/ 32 Amps, Single Pole |
| 165 | 6/32 Amps DP |
| 166 | 6/ 32 Amps, TPN |
| 167 | S/ F Modular Type Blanking Plate |
| 168 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excludingmodular plate as required. |
| 169 | SUPPLY & INSTALLATION OF LIGHTING FIXTURES |
| 170 | 20/22W LED Tube light with all neccssary accessories as required. |
| 171 | SITC of 6/7W LED round Down light with all neccssary accessories as required. |
| 172 | 1200mm (48\\") BLDC 5star rating 32W Ceiling Fan |
| 173 | 15' (380mm) metal exaust fan. |
| 174 | ACCESSORIES FOR DATA & TELEPHONE SYSTEM |
| 175 | S/ F PVC Conduit |
| 176 | Supplying and fixing of following sizes of PVC conduit along with accessories in surfac/ recess including cutting the wall and making good the same in case of reccessed conduit as required.(For Data & Tele. ) |
| 177 | 25 mm |
| 178 | Data & Telephone wiring in existing conduit |
| 179 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduitas required. |
| 180 | EXTERNAL LIGHTS |
| 181 | S.I.T.C of floowing rating LED Flood lighting luminarie with pressure die cast housing and toughened glass covern (IP 66 protection) in existing pole/pipe for supply voltage 1C[.Z70Y AC,50Hz. Luminarie shall be confirm tolS:,1,0322part-5/section-5 and shall be complete withall neccssary accessories as required |
| 182 | 90/100W LED Flood light |
| 183 | Supply of Copper Cables |
| 184 | Supplying & laying with Cable end termination of following 1100 volt grade PVC insulated sheathed copper conductor armoured cable as per specification in existing trenches, cable trays ducts over bed of sand, clamped includes anchor fastners to wall with suitable clamps, saddles fixing bolts includingconnecting testing and commissioning. |
| 185 | 3 Core 4 Sq.mm |
| 186 | Add GST 18 % |
| 187 | Add Labour cess 1% Please Enable Macros to View BoQ information |