Tender For Replacement And Rectification Of Auto Spring Charging Mechanism, Breaker Operation, Indication Circuits, Ct/Micom Related Issues And Allied Works In 33 Kv And 11 Kv Switchgear Panels At Substations
Tender Overview
Project Description
Tender for Replacement And Rectification Of Auto Spring Charging Mechanism, Breaker Operation, Indication Circuits, Ct/Micom Related Issues And Allied Works In 33 Kv And 11 Kv Switchgear Panels At Substations
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 08-Jun-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 23-Jun-2026 |
| 2 | 23-Jun-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 03-Jul-2026 |
| 3 | 08-Jun-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 23-Jun-2026 |
| 4 | 03-Jul-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 10-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Rectification of HT breakers auto spring charging mechanism including cleaning, lubrication, replacement of worn-out parts(i.e spring charging motor) as per specification and scope of work. |
| 2 | Rectification of HT breaker in and out mechanism including interlocks,etc. as required as per specification and scope of work. |
| 3 | Replacement and Rectification of control wiring, panel AC circuit, TPC & charging circuit faults, etc. as required. as per specification and scope of work. |
| 4 | Replacement and Rectification of indication lamps(relevant colour), wiring and accessories, etc. as required.as per specification and scope of work. |
| 5 | Supply and replacement of dual core CT 150-100/1+1 for 630 A VCB HT 33 KV panel, testing and commissioning, tightening, insulation, etc as required as per specification and scope of work. |
| 6 | Supply and replacement of dual core CT 300-150/1+1 for 630 A VCB HT 11 KV panel, including testing & commissioning, tightening, insulation, etc as required as per specification and scope of work. |
| 7 | Supply, installation and testing of relevant Protection MICOM relay including checking, fault diagnosis, reconfigurationand testing, etc. as required at 33 KV panel in MRSS as per specification and scope of work.. |
| 8 | Supply, installation and testing of relevant MICOM Protection relay including checking, fault diagnosis, reconfiguration and testing, etc. as required at 11 KV panel SS2, SS3 as per specification and scope of work.. . |
| 9 | Rectification including spares of DCDB Battery bank including testing, commissioning etc. as required as per specification and scope of work.. |
| 10 | Supply and installation of TNC switch suitable for all HT side breaker as per specification and scope of work. |
| 11 | HT panel cleaning, testing, commissioning and functional checks after repair, etc. as required.as per specification and scope of work. (33/11 kV Sub-station-1 nos., 11 KV sub-station-4 nos( SS-1, SS-2 and CSS) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-4 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender