| 1 | POINT WIRING: Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required - Group C (DSR-1.3.3) |
| 2 | Rewiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable and 1.5 sq. mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required - Group A (DSR-1.15.1) |
| 3 | Wiring for twin control light point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required.(DSR-1.4) |
| 4 | Wiring for light / power plug with 2 x 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed in suitable size of steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (DSR-1.5) |
| 5 | Wiring for light / power with 4 x 4 sq. mm FRLS PVC insulated coppeer conductor single core cable in surface / recessed in suitable size of steel conduit along with 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable cable for loop earthing as required.(DSR-1.6) |
| 6 | Wiring for circuit / submain alongwith earth wiring with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed in suitable size of steel conduit as required.DSR-18/ 1.7 |
| 7 | i) 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire DSR-1.7.1) |
| 8 | ii) 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire (DSR-1.7.2) |
| 9 | iii) 4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire (DSR-1.7.7) |
| 10 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).(DSR-1.31) |
| 11 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. (DSR-1.32) |
| 12 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed steel / PVC conduit as required.(DSR-1.19) |
| 13 | Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (DSR-1.21) |
| 14 | 20 mm (DSR-1.21.1) |
| 15 | 25 mm (DSR-1.21.2) |
| 16 | Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. DSR-18/1.24 |
| 17 | i) 5/6 A Switch (DSR - 2018/ 1.24.1) |
| 18 | ii) 15/16 A Switch (DSR - 2018/ 1.24.3) |
| 19 | iii) 3 Pin 5/6 A Socket outlet (DSR - 2018/ 1.24.4) |
| 20 | iv) 6 Pin 15/16 A Socket outlet (DSR - 2018/ 1.24.5) |
| 21 | v) Bell Push (DSR - 2018/ 1.24.8) |
| 22 | vi)Telephone socket outlet DSR -1.24.6) |
| 23 | Supplying and Fixing following sizes / modules , GI box along with modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) DSR-1.27.1 |
| 24 | 3 Module (100mmX75mm) (1.27.2) |
| 25 | 8 Module (125mmX125mm) (1.27.5) |
| 26 | 12 Module (200mmX150mm) (1.27.6) |
| 27 | Supplying and Fixing following modular base & cover plate on existing modular metal boxes etc. as required.DSR-1.28 |
| 28 | 1 or 2 Module (1.28.1) |
| 29 | 3 Module (1.28.2) |
| 30 | 4 Module (1.28.3) |
| 31 | 8 Module (1.28.5) |
| 32 | 12 Module (1.28.6) |
| 33 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.DSR-1.25 |
| 34 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required DSR-1.26 |
| 35 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.. DSR-2.18 |
| 36 | DISTRIBUTION BOARD: S &F surface / flush mounting 12 way SPN distribution board (Legrand Lexic) with additional metal door without MCB complete in all respect, as directed at site by Engineer in charge. UPPWD-1025A Cat -A |
| 37 | S & F surface/Flush mounting 12ways V TPN distributionboard with additional metal door without MCB complete in allrespect, as directed at site by Engineer in charge. Cat A.UPPWD-1029C |
| 38 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole Ps.No.1002 Cat A |
| 39 | S&F of 6 Amp. to 32 Amp. DP MCB (10 KA) C Curve Ps.No. (1009) Cat A |
| 40 | Supplying and fixing 63 Amp 4 pole MCB . Complete in all respects Cat -A, PS No 1020A |
| 41 | S&F of 80 to 100 Amp 4 pole MCCB (16 KA) Thermal Magnetic release PS No. (1021) Cat A |
| 42 | S&F of 250 Amp 4 pole MCCB (25KA) Thermal Magnetic release PS No. (1021G) Cat A |
| 43 | S&F and making connection of 25A 2 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as perdirection and satisfaction to the Engineer in charge. PS No. 392 |
| 44 | S&F and making connection of 40A 2 pole 30mA ELCB /RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge.PsNo. (393) |
| 45 | S&F and making connection of 63A 2 pole 30mA ELCB /RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. Ps.No (394) |
| 46 | Supply and fixing of recess/surface mounting round 15 Watt to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with extended heat sink, diffuser/ Reflector and driver set completed in all respects. CAT- AAA Ps.No.1403 |
| 47 | Supply and fixing of 36 watt to 46 watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of special Polycarbonate meterial and driver set complete in all respect. PS No. 1406. Cat-AA. |
| 48 | Supply and fixing of LED Tube Light with batten suitable for up to 1x22 watt LED tube light complete including tube etc. on surface complete in all respects. P.S No. 1413 Cat-AAA. |
| 49 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. Ps.No. 807 i) 40 A TPN |
| 50 | Supplying of Labour Electrician.2 Nos |
| 51 | Supplying of Helper 02 Nos |
| 52 | Supply and Fixing of 400mm dia decorative type bracket fan.( wall fan) complete in all respects as per direction of E/I. |
| 53 | Supply and Fixing of 1200mm dia Ceiling Fan complete in all respects as per direction of E/I. |
| 54 | Supply & laying of Al. Conductor PVC Insulated armoured served sheathed cables 1100 Volt grade at a depth of below ground level over a cusion of 750mm below ground level over a cushion of 75mm. thick sand all round and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by the Engineer - Incharge, complete in all respect, the armouring of the cable shall be properly connected with the earth conductor by clamps etc. as per PS No.-501 (Nicco,Grandlay, Havells,Kalinga, Skytone make) |
| 55 | i) 10 Sqmm x 4 core |
| 56 | ii) 16 Sqmm x 4 core |
| 57 | iii) 185 Sqmm x 3.5 core |
| 58 | S/F of palm or pin type copper tin plated cable socket (lugs) to the cable leads, insulating with tape and making connection etc. complete in all respects as per direction of E/I. P.S No. 504. |
| 59 | i) 400 Sqmm |
| 60 | ii) 185 Sqmm |
| 61 | iii) 120 Sqmm |
| 62 | iv) 95 Sqmm |
| 63 | v) 70 Sqmm |
| 64 | vi) 16 Sqmm |
| 65 | vii) 10 Sqmm |
| 66 | S/F of 400 Amp. Four pole Mouled case type on load change over switch with enclosure incl. the cost of labour T&P, Painting and other material required for proper completion of the work as per the direction and satisfaction of E/I.P.S.No 381A. |
| 67 | Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. DSR-18/15.4 |
| 68 | 3 output (1output per phase) and suitable for three phase supply. 15.4.3 /p-51 |
| 69 | Repairing of 11KV fuse wire/Jumper i/c supply and fixing of required size conductor, fuse wire of 11KV Line/DP structure of Transformer by takinng shutdown from UPPCL Department with all safety instruments like-safety belt, Gloves, shoes and other necessary items complete including all taxes. |
| 70 | Supply and fixing of LED Strip Light 5W/M with life L 70/40000 burning hr. of reputed LED make saffran/white/green dachable in 1M suitable for 240V AC 30m of strip for out door use with 3 year warranty complete in all respect as per direction fo E/I |
| 71 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 3000mm, outer pipe 50mm, inner dia 25mm, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.(P.S. No 725B) |
| 72 | Hire Charges of LED Light Multi Colour(RGB) Imported having 62 bulb & above with labour and transportation including prpper connection. Complete in all respects as per direction of E/I Please Enable Macros to View BoQ information |