| 1 | Taking down chowkats or frames (without taking off shutters from frame) not exc 1.50 Sqm each including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out holdfasts shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and as directed. |
| 2 | Taking down chowkats or frames (without taking off shutters from frame) exc 1.50 Sqm and not exc 4.00 Sqm each including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out holdfasts shall be finished identical to existing finish without any extra cost to Govt.) , complete all as specified and as directed. |
| 3 | Taking down shutters of any description not exceeding 1.0 Sqm each, from chowkhats/frames and removal to store for reuse or credit, complete all as specified and as directed. |
| 4 | Taking down shutters of any description exceeding 1.0 Sqm but not exceeding 2.0 Sqm each, from chowkhats/frames and removal to store for reuse or credit, complete all as specified and as directed. |
| 5 | Taking down wooden shutters of any description exceeding 1.0 Sqm but not exceeding 2.0 Sqm each, from chowkhats/frames and refixing in the same opening after necessary repair, easing and adusting, jointing replacement/refixing of mongries etc, complete all as specified and as directed. |
| 6 | Resecuring or easing & adjusting without taking down Shutters of any description exceeding 1 sqm each and not exceeding 2 sqm, complete all as specified and as directed. |
| 7 | S&F plain, solid, 2nd class hard wood straight chowkats and frames wrought framed rebated on the solid, rounded or chamfered put together with pinned at joint etc., complete all as specified and as directed. |
| 8 | S&F factory made pressed steel frames for doors with two rebates, of size 125 mm x 60mm, made out of 1.25mm thick sheet, one shop coat primer and necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and as directed. |
| 9 | S&F factory made pressed steel frames for doors with two rebates, of size 105 mm x 60mm, made out of 1.25mm thick sheet, one shop coat primer and necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and as directed. |
| 10 | M&L for providing PCC 1:3:6 type C0 using 12.50 mm graded crushed stone aggregates as in filling of pressed steel chowkhats, cill, step and for inserting hold fasts etc and similar work , complete all as specified and as directed. |
| 11 | M&L for plain cement concrete 1:2:4, type B-0 using 12.5 mm graded crushed stone aggregates as in benching, coping, bed plates ,foundation filling etc for including weathering, slightly rounded or chamfered angles and throating as directed including necessary formwork as required, complete all as specified and as directed. |
| 12 | S&F MS flat iron as in hold fast etc, wall ties, hooks for hanging fans and similar small articles conforming to Fe-290 Gde-E-165 , complete all as specified and as directed. |
| 13 | S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube in opening, complete all as specified and as directed. |
| 14 | S&F 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part-I), kiln seasoned and chemically presssure treated , complete all as specified and as directed. |
| 15 | S&F second class hard wood 35 mm thick plain, glazed and skelton factory made shutters, open rebated and prepared divided into squares with plain chamfered or rounded mitred and rebated sash bars any number, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutter as specified in SSR Part I, Section 8, Clause 8.24(a), kiln seasoned and chemically pressure treated , supplied and fitted to chowkats, complete all as specified and as directed.Note:- Glass or Wire cloth in panels will be measured and paid separately in relevent items. |
| 16 | S&F 30 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part-I and fitted to chowkats, complete all as specified and as directed. |
| 17 | S&F factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement forstyle and plain colour PVC sheets for top rail lock rail and bottom rail on either side and as gap insert for topo rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and jointed together with solvent cement supply & fixing in the frame at site, complete all as specified and as directed. |
| 18 | S&F 18 mm/ 19 mm thick prelaminated particle board, interior grade, prelaminated both sides with decorative choice lamination for wooden and fixed with screws to timber frame as in cupboards, shutters, shelves, pelmet etc. including fixing 18 mm wide 6 mm thick beading of Ist class HW (Teak) all around, fixed in repairs, complete all as specified and as directed. |
| 19 | S&F in repair's continuous ( piano ) hinges mild steel, bright finish or electro glavanised, size 30mm , complete all as specified and as directed. |
| 20 | S&F aluminium anodised, Hasp and staple of size 100mm, safety type, with mild steel hinge pin including bolt to hinge plate and fixed with screws, complete all as specified and as directed. |
| 21 | S&F 300 mm mild steel helical pattern door springs including roller and roller plate, complete all as specified and as directed. |
| 22 | S&F in repair's 300mm mild steel helical pattern door springs including roller and roller plate , complete all as specified and as directed. |
| 23 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm as in doors and windows with necessary nuts and bolts/ fillets , complete all as specified and as directed. |
| 24 | Supply and fix in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm as in doors and windows with necessary nuts and bolts/ fillets complete all as specified and directed. |
| 25 | S&F plain sheet glass 3 mm thick, ordinary quality, not exceeding 0.50 Sqm in each pane, and glazing with oil putty/wooden beads with nailing , complete all as specified and as directed. |
| 26 | S&F plain sheet glass 3 mm thick, ordinary quality, not exceeding 0.50 Sqm in each pane, and glazing with oil putty/wooden beads with nailing including hacking out old broken glass (any thickness size, quality or description) from wooden/ steel frames, glazed with putty or fixed with wooden beads/ metal pins, complete all as specified and as directed. |
| 27 | S&F in repair's 4 mm thick frosted sheet glass, ordinary quality and glazing with oil putty in squares n exc 0.5 sqm in each pane including hacking out broken glass from existing any type of frame, complete all as specified and as directed. |
| 28 | S&F stainless steel butt hinges, medium weight, 100mm long, cold rolled mild steel , complete all as specified and as directed. |
| 29 | S&F stainless steel butt hinges, medium weight, 75mm long, cold rolled mild steel , complete all as specified and as directed. |
| 30 | S&F 100mm long aluminium double leg door stopper fixed to door, complete all as specified and as directed. |
| 31 | S&F in repair's 100 mm long aluminium double leg door stopper fixed to door , complete all as specified and as directed. |
| 32 | S&F 150 mm long aluminium handles, cast type, anodised , complete all as specified and as directed. |
| 33 | S&F in repair's 150 mm aluminium handles, cast type, anodised, complete all as specified and as directed. |
| 34 | Supply and fixing 100 mm long aluminium handles, cast type, anodised complete all as specified and directed. |
| 35 | S&F 200 mm long aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and as directed. |
| 36 | S&F in repair's 200 mm long aluminium anodised barrel tower bolts of extruded section, complete all as specified and as directed. |
| 37 | S&F 100 mm long aluminium anodized, barrel tower bolt of extruded section, complete all as specified and as directed. |
| 38 | S&F in repair's 100 mm long aluminium anodized, barrel tower bolt of extruded section, complete all as specified and as directed. |
| 39 | S&F aluminium alloy sliding door bolt 250 mm long with hasp, staple ( bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and as directed. |
| 40 | S&F in repair's aluminium alloy sliding door bolt 250 mm long with hasp, staple ( bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and as directed. |
| 41 | S&F in repair's Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed ,complete all as specified and as directed . |
| 42 | S&F in repair's Door closer of aluminium (extruded section) hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg and fixed , complete all as specified and as directed. |
| 43 | M&L for applying two coats of synthetic enamel paint over and including a coat of pink primer, on new wooden surfaces over 10cm width or girth, including preparation of wooden surface, complete all as specified and as directed. |
| 44 | M&L for applying one coats of synthetic enamel paint on old wood & wood based surfaces of any descriptions exc 10 cm width or girth including preparation of wooden surface, complete all as specified and as directed. |
| 45 | M&L for applying two coats of synthetic enamel paint over and including a coat of red oxide primer, on new steel surfaces over 10cm width or girth, including preparation of steel surface, complete all as specified and as directed. |
| 46 | S&F MS Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed. |
| 47 | M&L for brick work with sub class 'B' bricks, straight or curved on plan, exceeding 6 metre mean radius built in cement mortar 1:6 including demolition of brick work or stone masonry built in cement mortar, complete all as specified and as directed. |
| 48 | M&L for Rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces, finished even & smooth without using extra cement, complete all as specified and as directed. |
| 49 | M&L for Rendering 5 mm thick in cement Plater of CM 1:4 on fair faces of brick work or concrete surfaces, mixed with integral water proofing compound as per manufacturers instructions over and including 10 mm thick backing coat in cement mortar 1:4 on fair faces of brick work or concrete surfaces finish even and smooth without using extra cement, complete all as specified and as directed.Note: Water proofing compound shall be measured and paid seperately under relevant item. |
| 50 | M&L for Rendering 5 mm thick in cement Plater of CM 1:4 on fair faces of brick work or concrete surfaces, mixed with integral water proofing compound as per manufacturers instructions over and including 10 mm thick backing coat in cement mortar 1:4 on fair faces of brick work or concrete surfaces finish even and smooth without using extra cement including taking down cement plaster, any description on brick or stone walls/ceiling etc including racking out joints, hacking for key, scrubbing down with water etc., complete all as specified and as directed.Note: Water proofing compound shall be measured and paid seperately under relevant item. |
| 51 | M&L for rendering 15 mm thick, cement plaster, in cement mortar (1:6) on surface other than fair face of brickwork and finishing surface even and smooth without using extra cement, including taking down cement plaster, any description on brick or stone walls/ceiling etc including racking out joints, hacking for key, scrubbing down with water etc., complete all as specified and as directed. |
| 52 | M&L for preparation of newly plastered or previously untreated surfaces and applying two coat oil bound distemper over one coat of primer on walls, complete all as specified and as directed. |
| 53 | M&L for preparing new plastered or unplastered wall surfaces for applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm, to match the existing surface of wall, complete all as specified and as directed |
| 54 | M&L for Second Class Hardwood timber Scantling unframed work Clean sawn in scantling complete including dismantling of unservicable timber scantling 40 Sqcm and over in sec in any position as in framed work, complete all as specified and as directed |
| 55 | S&F in repair's Anodised aluminium snap grid of Size 600X600mm' frame work for false ceiling with HPSC 4 mm thick Non asbestos fibre cement building boards white colour designer type ready to fix ,fixed or laid/ inserted to timber/GI/Aluminium framework as in Ceiling with including proper hanging arrangement after dismantling wall and celling board (fibre, pulp, insulation,glass etc) any thickness including cover fillets, complete all as specified and as directed. |
| 56 | M&L for 4 mm thick, 3 Nos. ply, plywood, grade BWR, type BB, fixed with screws to timber frame work,including dismantling existing wall and ceiling boards (fibre, pulp, insulation,etc.) or insulation boards/slabs/blankets,any thickness, including cover fillets, complete all as specified and as directed. |
| 57 | Taking down of existing aluminium door carefully except Floor spring/hydraulic door closer from the existing frame and repair the same for smooth operation/movement, including replacing of unservicable screw, cleats, door handle, aluminium hinge & beading etc and refixing in the same location after repairing all components, complete all as specified and as directed. Note: Area of door not exc 4.00 Sqm. |
| 58 | S&F in repair's unserviceable rubber packing of aluminium door & window including taking down carefully glass panels & re-fixing the same, complete all as specified and as directed. |
| 59 | S&F in repair's Brass type 4 lever mortice door lock for fixing in aluminium door/ wooden door including necessary grooving, screwing in aluminium door and aluminium frame for adjusting or fixing of mortice door lock, complete all as specified and as directed. |
| 60 | S&F 4.8 mm thick tinted Sheet glass, ordinary quality and in doors, windows, ventilator etc with rubber packing in square n exc 0.5 sq. m in each pane including hacking out old broken glass (any thickness and any size from aluminium beading), complete all as specified and as directed. |
| 61 | S&F 4.8 mm thick tinted Sheet glass, ordinary quality and in doors, windows, ventilator etc with rubber packing in square exc 0.5 sq. m in each pane including hacking out old broken glass (any thickness and any size from aluminium beading) , complete all as specified and as directed. |
| 62 | S&F butyl & bitumen Based flashing tapes/strips 100 mm wide are cold applied self-adhesive tapes with one side bitumen adhesive protected by release film and other side is reinforced aluminium foil to prevent leakages ,fill cracks & joints for metal ,cement asbestos ,fiber ,plastic ,vinyl etc., complete all as specified and as directed. |
| 63 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading and rubber for glazing/ paneling, C.P. brass/ stainless steel screws, including taking down of existing partiation with partical board etc., complete all as per architectural drawings and the directions of Engineer-in-Charge. |
| 64 | S&F powder coated aluminium door frame and shutter single leaf panelled door partly glazed with 5mm thick glass and partly 6mm thick prelaminated board door shutter divided into two panels fabricated including powder coated aluminium snap beading and rubber gasket/ lining for fixing of glass and prelaminated board panel. The door frame shall be fixed aluminium anodised bolt by drilling in the existing wall and with thrust bolt of suitable size. The door frame and shutter shall be comprising of the following section and fitting including taking down of existing shutter with frame and fittings, complete all as specified and as directed:-(a) Aluminium door frame section 101.6x44.5x1.27mm(b) Aluminium styles of shutter section 85x44.5x1.56mm(c) Aluminium top & bottom rail of shuttersection 101.6x44.5x2.5mm(d) Aluminium middle/ lock rail of shutter section 100x44.45x2mm(e) Aluminium handle 250mm long 02 Nos in each shutter(f) Aluminium tower bolt 200mm long as required as per normal(g) Six lever mortice lock brass(h) 03 Nos aluminium butt hinges 100mm long (i) 06mm thick pre-laminated board (j) 5.0mm thick tinted glass Note: In case of two leaf each leaf wil be measured seperately. |
| 65 | S&F in repair's powder coated aluminium grill 8 mm thick (anodised transparent or dyed to required shade acoording to IS: 1868 with minimum anodic coating of grade AC 15) of approved design /pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @200 mm centre to centre, including, cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and as directed. |
| 66 | M&L for prepration of old decorated wall by washing,rubbing down and stopping of old distempered and painted surfaces and applying one coat of oil bound distemper on walls, complete all as specified and as directed. |
| 67 | S&F in repair's existing false ceiling with HPSC 4 mm thick, non asbestos fibre cement building boards white colour designer type ready to fix, fixed or laid/ inserted to timber/GI/Aluminium framework with screws, as in ceiling, complete all as specified and as directed. |
| 68 | Demolition of existing cement concrete of any type in ground floor, complete all as specified and as directed . |
| 69 | M&L for glazed ceramic coloured tiles of size 450 X 300 X 6 to 7mm thick, conforming to IS 15622,Grade B III, on vertical surface of wall such as dados, skirting etc., set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick screed bed or bedding layer of cement mortar (1:4) and including dismantling existing floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises,complete all as specified and as directed. |
| 70 | M&L for Non - skid Ceramic tiles, coloured,7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, conforming to IS 15622,Grade B IIa, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer of cement mortar (1:4) and including dismantling existing floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises, complete all as specified and as directed. |
| 71 | M&L for Non - skid Ceramic tiles, coloured, 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, conforming to IS 15622,Grade B IIa, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer of cement mortar (1:4) and including dismantling existing floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises, complete all as specified and as directed. |
| 72 | M&L for Non - skid Ceramic tiles, coloured, 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, conforming to IS 15622,Grade B IIa,on vertical surface of wall such as dados,skirting etc.,set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick screed bed or bedding layer of cement mortar (1:3) and including dismantling existing floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises, complete all as specified and as directed. |
| 73 | M&L for Vitrified ceramic tiles light shade 8 to 9 mm thick (square/ rectangular) polished, area of each tile not exceeding 0.36 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement over screed bed or bedding layer 15 mm thick in cement mortar 1:4 after dismantling existing floor tiling including cement mortar bedding (but not backing), removing rubbish of the premises, complete all as specified and as directed. |
| 74 | M&L for Vitrified ceramic tiles light shade as in skirting of specified height cut from 10mm thick (square/rectangular) polished, area of each tile not exceeding 0.36 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement over screed bed or bedding layer 10 mm thick in cement mortar 1:3 after dismantling existing floor tiling including cement mortar bedding (but not backing), removing rubbish of the premises, complete all as specified and as directed. |
| 75 | S&F in repair's GI pipes 'medium grade' 15 mm bore galvanised,with all fitting and fixed complete to walls and ceilings or laid in floors ,complete all as specified and as directed. |
| 76 | S&F in repair's GI pipes, 'medium grade' 20 mm bore galvanised with all fitting and fixed complete to walls and ceilings or laid in floors including taking down exiting tube, complete all as specified and as directed. |
| 77 | Refixing of 15 mm bore old steel tubing and connections in new or old position (wall, ceiling,floors etc.) including taking up or down 15 mm dia steel tubing & connection, including cleaning, complete all as specified and as directed. |
| 78 | Refixing of 20 mm bore old steel tubing and connections in new or old position (wall, ceiling,floors etc.) including taking up or down 20 mm dia steel tubing & connection, including cleaning, complete all as specified and as directed. |
| 79 | S&F 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part – I ,including ball valves high pressure of PTMT (Minimum weight 210 gms) with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe, 20 mm bore and fixed and including dismantling of existing water tanks exc. 250 but not exc.500 litres capacity and removing to store, complete all as specified and as directed. |
| 80 | S&F 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part – I ,including ball valves high pressure of PTMT (Minimum weight 210 gms) with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe, 20 mm bore and fixed and including dismantling of existing water tanks exc. 500 but not exc.1000 litres capacity and removing to store, complete all as specified and directed. |
| 81 | S&F in repair's 500/1000 litres capacity rotational moulded polyethylene water storage tanks covers including necessary fittings required for fitting of cover to the tank, complete all as specified and as directed. |
| 82 | S&F in repair's 20mm ball valves high pressure of PTMT (Minimum weight 210 gms) with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore and fixed, complete all as specified and as directed. |
| 83 | S&F in repair's bib tap,cast copper alloy, fancy type, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule of 15 mm bore and fixed, complete all as specified and as directed. |
| 84 | S&F in repair's 15mm bore Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm-90gms), complete all as specified and as directed. |
| 85 | S&F in repair's angle stop valves,cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for steel pipe or for unions of 15 mm bore, complete all as specified and as directed. |
| 86 | S&F in repair's pillar taps, cast copper alloy, with capstan heads, fancy type,chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe of 15 mm bore, complete all as specified and as directed. |
| 87 | S&F in repair's pillar tap Brass chromium plated mixer for mixing hot & cold water screwed down for iron pipe 15 mm bore,complete all as specified and as directed. |
| 88 | S&F in repair's health faucets (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connection and fixed in position, complete all as specified and as directed. |
| 89 | S&F in repair's cast copper alloy,chromium plated urinal spreader, screwed for iron pipe of 15 mm bore, complete all as specified and as directed. |
| 90 | S&F waste coupling of PTMT (half or full threaded) (Minimum weight 45gms) for 32 mm bore discharge pipe, complete all as specified and as directed. |
| 91 | S&F in repair's PVC connections 15 mm size with PTMT nuts of length 450 mm, complete all as specified and as directed. |
| 92 | S&F in repair's flush pipe of polyethylene of low or high density or PVC, 32 mm dia, for low level cistern,complete all as specified and as directed. |
| 93 | S&F in repair's PVC collapsible waste pipe (31/32 x 800) mm, complete all as specified and as directed. |
| 94 | S&F 600 mm X 450 mm bevelled edge mirror of selected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed. |
| 95 | S&F in repair's vitreous China wash down closet pan and trap EWC type, white, with plastic seat cover including connection to drain (or outgoing pipes ) and to flushing pipe,antisyphonage pipe ,fixing bolt etc and making good damaged portion, complete all as specified and as directed. |
| 96 | S&F in repair's vitreous China wash down closet pan and ' S ' trap EWC type\\"Swirl \\" of size 690 x 370 x645 mm , with combined twin flush fitting , white, with soft close seat cover including connection to drain (or outgoing pipes ) and to flushing pipe,antisyphonage pipe ,fixing bolt etc and making good damaged portion, complete all as specified and as directed. |
| 97 | S&F in repair's Vitreous China squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rest and 'P' or 'S' trap, including provision of lime concrete bedding, connection to trap and flushing pipe etc complete (excluding flushing cistern and flush pipe ) finishing with PCC gap between surface and new WC, complete all as specified and as directed. |
| 98 | S&F in repair's Vitreous China urinals, half stall type (back or corner wall type)with grating, spreader and union for discharge pipe and waste pipe (excluding flushing cistern)complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, flush pipe, grating and Union for discharge pipe, complete all as specified and as directed. |
| 99 | S&F in repair's Vitreous China Urinal flat back size bowl type 465x355x265 mm white (minimum),with grating and union for discharge pipe and waste pipe (excluding flushing cistern) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, complete all as specified and as directed. |
| 100 | S&F in repair's PVC valve less, syphonic action type, flushing cistern, low level,white, with inlet, ball valve, float and handle, of capacity 10 Litres, including brackets, flush pipe, complete all as specified and as directed. |
| 101 | S&F in repair's plastic water closet seat cover, closed pattern with flat bottom,and cover and mild steel chromium plated or aluminised hinging device, complete all as specified and as directed. |
| 102 | S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, laid in trenches or in floors, including taking down existing pipe with fitting by necessary excavation, return filling and demolition of PCC etc if required, complete all as specified and as directed. |
| 103 | S&F 75 mm bore PVC (SWR) bends any radius, complete all as specified and as directed. Notes:- (i) The existing fittings are deemed to be taken down along with the SWR pipe. |
| 104 | S&F 110 mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints,fixed to walls including taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks,etc.(measured overall as fixed along the centre line over fittings and accessories), complete all as specified and as directed. |
| 105 | S&F 110 mm bore PVC (SWR) bends any radius, complete all as specified and as directed. Notes:-(i) The existing fittings are deemed to be taken down along with the SWR pipe. |
| 106 | S&F in repair's Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union, complete all as specified and as directed. |
| 107 | S&F in repair's tubular Towel rail of 20mm dia and 600 mm long of brass chromium plated fixed with chromium plated screws, complete all as specified and as directed. |
| 108 | S&F in repair's Wash Hand Basin 550x400mm, vitreous China (flat back or angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe, complete all as specified and as directed. |
| 109 | S&F in repair's Wash Hand Basin 565x430x845mm, vitreous China,one piece wash basin with padestal ,white colour , any size, including fixing it with necessary fiiting but exclusive of fixing of supply and waste pipe, complete all as specified and as directed. |
| 110 | S&F in repair's fancy glass shelf 300mm long fixed with SS screw to wal,l complete all as specified and as directed. |
| 111 | S&F in repair's stainless steel bathroom soap holder fixed to wall with ss screw with wooden clits, complete all as specified and as directed. |
| 112 | S&F in repair's sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, complete all as specified and as directed. |
| 113 | M&L for powder coated (minimum thickness of powder coating 50 micron) aluminium three track window and ventilator frame with powder coated (minimum thickness of powder coating 50 micron) aluminium sliding glazed shutters (2 Nos Glazed shutter & 1 Nos Gauzed shutter), made out of aluminium section weighing not less than 0.55 Kg/RM without sash bars, including necessary jointing cleats, glazing clips, rubber packing, powder coated (minimum thickness of powder coating 50 micron) aluminium snap beading, locking arrangements, handle screws etc. with 4mm tinted glass, stainless steel wire mess including taking down of existing shutter with frame, complete all as specified and as directed. |
| 114 | M&L for 2nd class hardwood Plain fillets. square, rectangular or triangular in section Exc 13 Sqcm & n exc 25 Sqcm in area, clean sawn, secured with nails or brads.,including dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sqcm in section (unframed ), Complete all as specified and as directed. |
| 115 | M&L for Second Class Hardwood timber Scantling unframed work Clean sawn in scantling complete including dismantling of unservicable timber scantling 40 Sqcm and over in sec in any position as in framed work, complete all as specified and as directed. |
| 116 | S&F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per direction of Engr in charge ,including dismantiling existing wall panneling, complete all as specified and as directed. |
| 117 | S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per as per direction of Engr in charge,including dismantling of existing framing ,fillet etc., complete all as specified and as directed. |
| 118 | M&L for powder coated aluminium door frame and shutter single leaf panelled door partly glazed with 5mm thick glass and partly 6mm thick prelaminated board door shutter divided into two panels fabricated including powder coated aluminium snap beading and rubber gasket/ lining for fixing of glass and prelaminated board panel. The door frame shall be fixed aluminium anodised bolt by drilling in the existing wall and with thrust bolt of suitable size. The door frame and shutter shall be comprising of the following section and fitting including taking down of existing shutter with frame and fittings, complete all as specified and as directed:-(a) Aluminium door frame section 101.6x44.5x1.27mm(b) Aluminium styles of shutter section 85x44.5x1.56mm(c) Aluminium top & bottom rail of shuttersection 101.6x44.5x2.5mm(d) Aluminium middle/ lock rail of shutter section 100x44.45x2mm(e) Aluminium handle 250mm long 02 Nos in each shutter(f) Aluminium tower bolt 200mm long as required as per normal(g) Six lever mortice lock brass(h) 03 Nos aluminium butt hinges 100mm long (i) 06mm thick pre-laminated board (j) 5.0mm thick tinted glass Note: In case of two leaf each leaf will be measured and paid seperately. |
| 119 | M&L for 18-20mm thick Granite (pure black colour) stone work (table rubbed and polished) as on horrizontal/vertical surface such as cooking platforms, window cills, steps and like, set in neat grey cement slurry, laid over and including 20mm thick bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, ncluding dismantling existing stone slabs and tiles of any description or thickness,laid,bedded in any mortar, complete all as specified and as directed. |
| 120 | M&L for Providing precast cement concrete type-B1 1:2:4 (20 mm Graded ) set in cement mortar 1:6 as in landings, cover slabs (for man holes,drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces, including of demolition of existing reinforced cement concrete slab of any thickness, complete all as specifiecd and as directed. |
| 121 | M&L for mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, Complete all as specified and as directed. |
| 122 | M&L for square/rectangular designer bevelled edge looking mirror of 5 to 6mm thick selected quality glass, mounted on 6mm thick AC building board or commercial plywood of direct to wall and fixed with 04 Nos stainless steel wall touch holding brackets suitabel for wall mounted mirror with plastick plugs, complete all as specified and as directed. |
| 123 | S&F in repair's stainless steel anodised curtain rod 20mm dia, including set of fixing bracket, fennels with stops, rollers etc, fixed to wall, length 1.50 to 2.50 metre, including removal of old one to store for reuse or credit, complete all as specified and as directed. |
| 124 | S&F in repair's chromium plated towel ring fixed to wall with chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms), complete all as specified and as directed. |
| 125 | S&F in repair's Grating doom 100 to 125 mm dia PTMT with/without hole, complete all as specified and as directed. |
| 126 | S&F in repair's flexible/collpasible PVC waste pipe 32/40x800mm long for kitchen sink/ wash basin, complete all as specified and as directed. |
| 127 | Declogging and cleaning of floor trap/nahani trap/gully trap and clearing of blockage for clog free flowing of waste water upto the first manhole, complete all as specified and as directed. |
| 128 | Declogging and clearing of blockage of IWC/ EWC/ Urinal by removing chocked wastes/silt and mud etc., including removal of debris from site and washing down thoroughly for free flowing of waste upto 1st manhole and finally cleaning the washroom/toilet with clear water throughly or removal of debries/dirt etc.,complete all as specified and as directed. Materials and Labour for rendering 8 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 12 mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed.Note: - (Water proofing compound will be measured and paid separately) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail