Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Architectural Drawings:- Consultency for civil and electrical requirements. preparing detailed architectural plans (2D/3D) , elevations, sections for partitions, falseceiling and other associated civil/electric works such as electric load calculations/detailed electric components like DG Set ,Ups,Load Distribution,Electric Panels,HVAC'S, Fire Gas Supperation system, components with desired specification and other structural modifications etc. Preprations of furniture details and drawings etc., Prepration and submission of complition documents etc. dully certified safety clerance from electric/ mechanical inspection division Jammu. |
| 2 | Civl works:- Site Clearance and Cartage: General housekeeping of site including regular removal of malba, debris and waste material and keeping the site clean and workman like. |
| 3 | Demolition of Existing Brick Walls, 115/230 mm: Demolishing brick work manually/by machanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 4 | Dismantling of Existing Door with Frames: Dismantling and removal of existing door frames with glazing and cartage of the same to the nearest dumping grounds. |
| 5 | Dismantling Aluminium partition/Windows, wooden paneling : Dismantling & Removing of existing Gypsum board Parititon with frames ,Skins & glazing / glass / wooden paneling etc complete and disposal of unserviceable material incl.stacking of servicable material complete job. |
| 6 | Full Brick Wall: Providing and constructing 230 mm thick brick wall in 1:6 cement sand mortar incl all carriages . |
| 7 | Half Brick Wall: Providing and constructing 115 mm thick brick wall in 1:4 cement sand mortar with 6 mm diameter MS bar reinforcement at every fourth course. |
| 8 | Cement Plaster: Providing and applying to existing brick masonry in line and level about 12 to 18 mm thick 1:4 cement and sand mortar finished including curing etc. over new brick walls wherever old plaster is loose and wherever surfaces are required to be made good and level incl all carriages. |
| 9 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 10 | POP : Providing & applying average 12mm thick plaster of Paris to the walls and columns in square plumb line and level including scraping and removing the existing POP finish, hacking the surface of walls/columns. After leveling, the surfaces to be finished to receive paint etc. Rate to include providing for Al channels and grooves at all junctions and corners. |
| 11 | RCC Lintels: Cast and Install 1:2:4 ( 1 cement; 2 coarse sand; 4 graded stone aggregate 20 mm nominal size) RCC lintol to span door openings, including the cost of shuttering, centering and steel reinforcement (8/10 mm dia) |
| 12 | Cement Sand Leveling Screed: To provide and lay approx 50-mm thick top layer of 1:2:4 concrete cement finish to provide a finished horizontal surface, ready to receive floor finishes, tiles, carpets etc. |
| 13 | Cinder Filling: To provide and lay approx 100 to 450 mm cinder filling as per approved design to raise floor for visual access to the video wall. Top to be finished with screeding as an extra item. |
| 14 | FRAMELESS GLAZED DOORS : Providing and fixing 12mm toughened glass door 2400/2500 mm x 1200 mm. The shutter will be fixed on Ozone Patch fitting set inclusive on top and bottom patch, lock set and floor spring. Rates to be inclusive of all necessary hardware fittings including SS handle, lock, stopper and stay. Hardware set to be as follows:• Ozone 9400 Floor Spring with • Ozone Top pivot OPF 2• Ozone Bottom Pivot OPF 3• Ozone Patch lock OPL1• Small Pivot FS ACC GDP• H type brushed SS Handle Set, 35 x 1000 mm D shaped floor mounted door stopperRefer to Door Schedule drawing |
| 15 | FRAMELESS GLAZED DOORS : Providing and fixing 12mm toughened glass door 2400/2500 mm x 1000 mm. The shutter will be fixed on Ozone Patch fitting set inclusive on top and bottom patch, lock set and floor spring. Rates to be inclusive of all necessary hardware fittings including SS handle, lock, stopper and stay. Hardware set to be as follows:• Ozone 9400 Floor Spring with • Ozone Top pivot OPF 2• Ozone Bottom Pivot OPF 3• Ozone Patch lock OPL1• Small Pivot FS ACC GDP• H type brushed SS Handle Set, 35 x 1000 mm D shaped floor mounted door stopperRefer to Door Schedule drawing |
| 16 | FIRE RATED DOOR WITH PANIC BAR: P&F Fully insulated Steel Composite light Flush Fire Doors with 2 hour fire rating in conformance with IS 3614 Part 2 and BS 476 Part 22. Door frames to be double rebate profile of 143 mm width and 57 mm height manufactured from 16 gauge galvanized steel, profile to have bending radius of 1.4 mm supplied in Knock down form for butt joint assembly at site. Door Shutter in 46 mm thick manufactured from two 18 gauge galvanized steel sheets lock seam jointed at stile edges to form a double skin fully flush shell. Infill of Properitory insulation material to be provided for structural rigidity & additional reinforcements & sound Insulation for all hardware fixtures as required. Complete with all harware including locks, door closer, door stopper etc as reqd.B102 Overall door size to be 1200-1500x2400 mm. Hardware set to be as follows:• Yale Heavy Duty Door Closer NSK – 680• SS Hinges,1250 mmx75 mmx3 mm hinges, 4 Nos.• Dorset SS lever handle with mortise lock.Panic Bar with single point rim panic latch. |
| 17 | FLUSH DOORS, LAMINATED, WITH VISION PANEL: P&F Semi solid core laminated DOOR formed out of 25X 100 mm wide CPTW frame 6 mm thick comm. ply skins, and faced both sides with 1 mm thick Laminate.. All wood and faces to be stained and melamine polished to Architect’s approval. Door to have vision panel formed of 8/10mm toughened glass. Sizes of cut-outs as per detailed drawing. Complete with all hardware including locks, door closer, doorstoppers etc as required. Overall door size to be 1000-1200 x 2100-2400 mm. Refer to Door Schedule drawing |
| 18 | FULL HEIGHT FRAMELESS GLAZED TOUGHENED PARTITION: Fabricating and fixing of 12mm thk. toughened Glass partition with concealed fixing arrangement in floor and ceilings as/architect’s instructions. The rate shall include sealing all joints with non staining clear silicon sealant/UV treated, machine cut, machine polished edges, tapers to design. |
| 19 | FULL HEIGHT GYPSUM BOARD PARTITION: Providing and fixing 75 mm thick GYPSUM partition faced both sides with 12 mm thick, tapered edge gypsum board (Conforming to IS-2095-1982), screw fixed with dry wall screw of 25 mm at 300 mm centers to either sides of 48 mm GI studs (.55 mm thick), having one flange of 34 mm and other flange of 36 mm, placed at 610 mm center to center (both ways) in 50 mm floor and ceiling channels of 32 mm section. Skirting, door junction and material transition sections to be in hardwood frame 50 x 50 to provide 10x10 grooves at all ends. If any hardwood sections are provided, these are to be coated all over with 2 or more coats of viper anti-termite/fire retard paint. Inside voids to be filled with 50 mm thick panels of glass wool/ rock wool. All gypsum board edges to be protected with aluminum angles. Partition to include laminated skirting on both sides as required. |
| 20 | FULL HEIGHT PLYWOOD PARTITION: Providing and fixing 19 mm thick PLYWOOD partition faced both sides as per required with 19 mm thick, Plywood board ,50mm GI Frame (Armstrong) incl. filling Glass Wool, screw fixed with dry wall screw of 25 mm at 300 mm centers to either sides of 25 mm GI studs. |
| 21 | FULL HEIGHT PLYWOOD PANELLING : Providing and fixing 12 mm thick PLYWOOD partition faced single sides as per required with 12 mm thick, Plywood board ,50mm GI Frame (Armstrong)/solid wood incl. filling Glass Wool screw fixed with dry wall screw of 25 mm at 300 mm centers to either sides of 25 mm GI studs. |
| 22 | PARTITION ABOVE FALSE CEILING : Partitions of GI/wood frame and Gypsum Board and without skirting, to be installed over false ceilings. |
| 23 | LACQUERED GLASS PANELLING: Form paneling on brick wall and columns with 8 mm thick ply faced front side with 6-8 mm thick non toughened glass. Lacquered glass with supirior quality Architect’s approved shade. Ply face to be painted with color to match the glass. Glass to be fixed with dow corning/ 3M high bond tape of adequate bond strength, to laminated strips affixed to the backing ply. Overall specifications, supporting and edge treatment of glass. |
| 24 | LAMINATE : 1 mm thick laminate as per architect’s approval. finished in laminate as specified by Architect |
| 25 | WALL PAPER PANELLING: Provide & Install of wallcovering PVC coated with woven cotton OR woven Polyester backing with a grammage of 350 to 450 Gms/Sqm. The substratum/Base shall be flat, firm, dry, free of dust and grease and of uniform colour made up of POP/Gypboard surfaces. Pre-treat the substrate with Primer with a Block Brush Or Spray and allow it to dry for minimum 8 hours The substarte base moisture level should not exceed 6% of the building moisture limit ( to be verified with Hygrometer).The temperature of the underlying surface must be at least 10°C. As per approved by Architect. |
| 26 | LAMINATED SHELVES: Fabricate and install 250/300 mm deep, 1000/1500 mm long Laminated shelves. Shelf to be mounted on to existing partitions, walls etc as directed with concealed fixing detail. Shelves to be fabricated with 2 Nos. 19 mm thick board, with 19 mm filler pieces, faced all sides with 1 mm thick laminated or MDF shelves finished with duco paint, high gloss. |
| 27 | ALUMINIUM SKIRTING: Fabricating and fixing 100 mm High Aluminium skirting with al. strip cover over partition & pop surface :‐ providing and fixing 1.0 to 1.5mm thick 50mm high extruded anodized aluminum skirting as per manufacture spec with Aluminium Capping. Contractor to ensure ply backing w/o additional cost for fixing of the skirting. Corners to be buffed to Chamfer Details and to be installed neatly without Corner capping. Base rate of aluminium skirting 600 per rmt. as architect approved. |
| 28 | FULL HEIGHT STORAGE, LAMINATED: Fabricating and fixing full height storage cupboards as per details. Top, bottom and shelves to be made out of 19 mm thick pre-laminated laminated commercial board with Ane grey wood lipping. Back to be provided of 8 mm thick commercial ply. Shutters to be made out of 19 mm thick board faced with 1.00 mm thick laminate. All internal surfaces to be faced with 0.8 mm thick laminate of approved shade. External surfaces finished on exposed sides with 1 mm thick laminate. Complete with all necessary fittings like hinges, ball catchers, tower bolts, locks, handles, adjustable shelves etc. as per directions of Architect. Cupboard depth of 400-750 mm. Adjustable shelves to be supported on half cut; 10 mm dia s.s glass pins. |
| 29 | FIRE SIGNAGE, LARGE: Providing and Installing Double sided Glow signs- fire exit and directional signage – of GEO/GLOLITE or equivalent make at locations indicated by Architect including all exit points and directional signage. Size of Glow signage to be 300 mm x 100 mm (Battery operated). |
| 30 | FIRE SIGNAGE, SMALL: Providing and installing fire extinguisher signage as per item number e.1 above but of size, 100 x 100 mm |
| 31 | LOGO SIGNAGE: Fabricate and install Company corporate logo as per company supplied artwork. Logo to be in 15/18mm thk 3 D Acrlic/ MDF Letter cuts . Signage of owner’s Logo, Typeface etc. as required. Size 1050x450mm approx. Final size post approval |
| 32 | HANGING SIGNAGE: |
| 33 | INTERNAL SIGNAGE – MTG/CONFERENCE/CABIN ROOMS: Provide and install internal signage for meeting Rooms. Signage to be printed on 250 x 250 mm sparkle film and adhered to glass partition of meeting room. |
| 34 | FROSTING FILM: Provide and apply frosting film, sparkle finish, on glazed partitions doors etc. in patterns as provided by the Architects. |
| 35 | GLASS SHELVES: Provide and install 10 mm thick glass shelves of size 1000 x 200-300 mm. Shelves to be installed on SS glass pins and edges of glass to be machine ground and polished. |
| 36 | MARKER TRAYS: Fabricate and Install laminate marker tray of size 500 mm x 100 mm x 50 mm, fabricated out of 25 mm thick boards faced with 1 mm thick laminate. Conceal mounted on existing partitions, walls etc. |
| 37 | WASTE BINS: Provide and Install Stainless Steel perforated waste bins, of size 400 mm high and 300 mm dia as per approved samples. |
| 38 | TILES Designer : Provide and lay tiles (size 1200x 600) of approved make. Shade to be finalized by Architect. |
| 39 | CARPET/LAMINATED TYPE -1 : Provide and lay nylon carpet tiles (size 595 x 595) of make CIT (Carpet International) or equivalent. Shade to be finalized by Architect. |
| 40 | ACCESS FLOOR: Providing and fixing access floor panels adjustable (300+/- 20mm) height under floor construction of light weight grade (15 KN/m2) UDL panels of 600x600x31mm thickness faced with 3 mm thick anti stat laminate on top or Bared faced , with BTW stained black edge lipping of tapered profile and aluminum sheet at the bottom. Hewetson make or equivalent. Adjustable jacks to be manufactured from pressed formed corrosion resistant galvanized steel, placed on the pedestal (of axial load 22.5 KN), zinc plated consisting of anti-vibration head cap with cruciform up-stand and four panel locating studs, etc. complete. The rate to include cutting tiles for access to services and also includes supply of 2 nos. of vacuum tile lifter. |
| 41 | RUBBER MAT FLOOR: P&I rubber mat in battery and Ups room as required. |
| 42 | EMULSION PAINT: Providing and applying plastic/acrylic light textured emulsion paint to gypsum walls, POP puning, Gypsum ceiling and existing plastered ceiling, including paint putty, base coat as pre manufacturers recommendations and finishing with 2/3 coats of plastic / acrylic emulsion paint of approved color and make. Surface coating to be achieved as per manufacturer’s recommendations for coverage of paint. |
| 43 | Rodent management system:This Service is carried out for controlling rat problem inside as well as outside the premises and safeguarding the important files, papers, boxes, carpets, electrical and telephone wiring. files papers, boxes, carpets,electrical and telephone wiring, wooden ceiling, paneling, cardboards, raw materials etc. from rodents damage. Area of treatment :- This service is carried out for controlling Rat problem by putting Rodent Box / Glue Traps/Rodenticides. This Service will be provided to you in the entire area as well as entire plot, inside the building area and out side the building premises complete as directed by engineer in charge. 1. Rodent control:-a. Bromadiolone .005%b.Klerat Waxblocks -Syngentsc. Recumin Bat or Powderd. Mechanical Traps (Rodent Box)e. Glue Traps. |
| 44 | Water proofing work in Data Center/Terrace engineering in charge |
| 45 | Providing and fixing of Nitryle Rubber closed cell foam sheet of 12 mm to be glue to the floor with rubber based adheshive/ |
| 46 | GYPSUM BOARD CEILING: P&F 12 mm thick Gypsum board to G.I. framing perfect in level including making grooves at the junction of ceiling and walls/columns/partitions etc., making rectilinear stepped profiles, cut out for light fittings, A/C grills, speakers, services etc etc. and including providing and fixing necessary G.I./wooden frame supports for the above fixtures and additional suspenders to hang the same independently. G.I. frame to consist of proprietary supplied frames and as per manufacturers recommendations, suspended from RCC slab with dash fasteners / or anchored to exposed reinforcement of structural slab by means of GI proprietary angles. Gypsum board fixed with proprietary supplied fixing devices and including top coat and finished to receive paint. All complete including 100/150 wide return air slits & A/C boxing wherever indicated. |
| 47 | TILE GRID CEILING : Providing and Fixing mineral fiber ceiling consisting of tiles and grids as follows:1. AMF/USG, 0.7 NRC or equivalent AMF, 600 x 600 mm nominal size range or equivalent with regular edge. 2. Ceiling grid to be of hot dip galvanized steel system, power coated white finish, including main runners, cross tees and wall angles. Profile to be used is, 15 mm T Grid.3. Main runners to be spaced at 1200mm centers, fixed to soffit by approved hangers at 1200 mm distance. First and last hangers should not be at a distance of more than 450 mm from the adjacent wall. 600 x 600 mm module to be formed by fixing 600 mm cross tee between center of 1200 mm cross tees. Wall angels to be secured to wall at 450mm centers. |
| 48 | ACCESS PANEL : P&F 12mm thick commercial board As per requeried size faced with enamel paint to match ceiling,to G.I framing perfect in level to from access panel for AC ducts and ductable AC Units. |
| 49 | ACP SHEET PANELING : P&F 4mm thick Aluminium composite panel As per requeried size frame with aluminium channel/tube as per requied framing perfect in level. |
| 50 | CREDENZA: Supply & Installing Credenza as per dwg. |
| 51 | WORKSTATIONS. Curvis/Linear Workstation with square leg 1800x1000x750mm with Metal perforated screen as architect approved. |
| 52 | RECEPTION DESK: Supply and installing reception desk as per architects design. Reception desk to consist of front and side units along with storage units. Front unit to have additional horizontal surface at ht. 1200 mm above the floor level. Top & sides finished with 100 mm thick edge polished Duco to Architect’s approval. Table to have wire management detail, if required. O/A dimensions as per drawing All drawers to have White Duco fronts on all sides formed of 19 mm thick board and 12 mm thick lipped sides, and back and 6 mm thick comm. ply bottom. Duco to be finished with PU top coat. Drawers to be hung on Aries nylon glide and be centrally lockable. Provide SS Continous recessed handles from Hettich for drawer handles |
| 53 | Roller Blinds as per approved by Architect |
| 54 | WPC/PVC PANELING: Providing & Placing as per approved design. |
| 55 | Pedestal |
| 56 | DG/PANEL Foundation and lawn devlopment Providing and fixing in position specified grade of reinforced cement concrete , excluding the cost of centering, shuttering, finishing, finishing and reinforcement- 1:2:4 ( 1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
| 57 | Shuttering for DG Platform |
| 58 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars |
| 59 | Structural Steel |
| 60 | Polycarbonate Sheet 10mm |
| 61 | Providing & fixing Chainlink fencing of 10 gauge on the existing frame including welding , fastening , painting etc. as required |
| 62 | LAWN DEVELOPMENTBeautification of the landscaped area (include : Levelling of the soil, plantation of saplings -50 nos.) |
| 63 | Providing and laying machine cut, mirror polished, Italian Marble stone flooring/Granite laid in required pattern in linear portion of the building all complete as per architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified. 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc. |
| 64 | Providing of Grass for the facility by means of Different type of Grass |
| 65 | Supply of Artificial Grass of 25mm thick, green colour artificial grass stands low on maintenance and high on durability, its could fit in any environment and in any climatic condition. |
| 66 | Supply & fixing of Artificial Mat \\"A\\" Category of green colour artificial grass stands low on maintenance and high on durability, its could fit in any environment and in any climatic condition for wall. |
| 67 | Acoystic Polyester Fiber Panel as per approved Architect |
| 68 | Providing & Installation of Baffle ceiling system comprises of 50 mm x 100 mm (50 mm width & 100 mm Height) U Shape panels in RAL color finish. Panels shall be made of 0.5 mm thick galvanized steel after Powder-coated and length up to 4000 mm. Panel shall be high corrosion resistance and good color stability. Centre to Centre panel gap will be 150 mm. Panels are fixed on to roll formed carriers 20 mm wide x 40 mm deep out of 0.80 mmG.I sheet Powder-coated color with cutouts to hold the panels in module of 50 mm at maximum 1200 m c/c. Carriers are suspended from the roof or truss by 6 mm dia. galvanized steel wire rod hanger with special height adjustment suspension clip at max. 1200 mm c/c. Hangers are fixed to the roof by ‘J’ hooks or ceiling brackets and nylon inserts. Panels are factory cut in lengths up to maximum 4.0 m to suit site dimensions or shop drawings. Top cap and side cap are used to cover the edges of the panels. |
| 69 | Dismantling of CC floor : Dismantling of existing cc/Kota floor approx thick 100 mm complete and disposal of unserviceable material. |
| 70 | Anti termitte: Treatment of soil under existing floors/wall using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: with Chlorpyriphos/Lindane E.C. 20% with 1% concentration including cost of chemical. |
| 71 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 72 | Supply and fixing of Hexagonal light as per direction by Architect. |
| 73 | WOODEN FLOORING : Providing and fixing of wooden flooring 10 mm thick as per directions of Architect. |
| 74 | Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge. |
| 75 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead For thickness of tiles 10 mm to 25 mm. |
| 76 | Providing and laying 1200x600 mm Wall tiles in different sizes with water absorption less than 0.08% and conforming to IS : 15622 of make Asian/ Kajaria/Sunheart/ Equi. in all colours and shades including grouting the joints with matching synthetic grouts etc. of approved brand and manufacturer recommendation etc all complete. |
| 77 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm sqm |
| 78 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This indcludes jointing of pipes & fittings with one step CPVC solvent cement & testing of joints complete 20mm nominal outer dia pipes |
| 79 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete |
| 80 | 75 mm nominal inner dia pipes |
| 81 | 100 mm nominal inner dia pipes |
| 82 | Providing and fixing wall mounted including seat cover KOHLER Forefront or Equi. Complete with all fittings, brackets, nuts, bolts etc. |
| 83 | Providing and fixing Single lever basin mixer or Equi. |
| 84 | Providing and fixing Vanity counter of size 900 x 600mmx450mm with Italian Marble/ Corean 16mm thick including facia 100 mm heigh and 150 mm skirting on vertical surface all complete as per approved design |
| 85 | Providing and fixing Counter top wash hand basin of size 535x370x200mm . all fittings, C.P. waste etc. all complete. |
| 86 | Providing and fixing 15 mm dia Angle Valve |
| 87 | Providing and fixing CP brass bottle trap of size 38 mm make Kohler or Equi. for wash basin, sink and urinal etc.of aproved quality all complete |
| 88 | Providing and fixing C.P. brass toilet paper holder all complete |
| 89 | Providing and fixing C.P. brass Towel Rack all complete |
| 90 | Providing and fixing C.P. brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screws 600x20mm size etc all complete |
| 91 | Providing and fixing 100mm CP grating etc, all complete |
| 92 | Supply and installation of heavy duty type exhaust fans of Following size sweep with louvers/ shutters including all accessories/ installation materials required 250mm sweep 900rpm, single phase |
| 93 | Providing and fixing Decorative mirror with teak wood frame with spirit polish of size 1500x900 mm of approved quality fixed to wall with SS studs and washers etc all complete |
| 94 | Providing and fixing concealed flushing Cisterns 4litre/8 Litre capacity complete with frames, fittings, nuts, bolts with Face plates dual operated. |
| 95 | Providing and fixing Kimberley clark soap dispenser etc complete |
| 96 | Providing and fixing kimberley clark napkin holder for bathroom etc complete including the cost of one set of napkins. |
| 97 | Providing and fixing health faucet etc all complete |
| 98 | Providing and laying machine cut, mirror polished, Italian Marble stone/Granite flooring laid in required pattern in linear portion of the building all complete as per architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified. 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc. |
| 99 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in- charge. |
| 100 | Providing and fixing hand drier etc complete Approved by Architect . |
| 101 | PART-I ELECTRICAL WORK:- SI/T/C of DSP controlled 3ph-3ph, 2 x 150KVA/150KW Modular UPS each with inbuilt 4 X 25 KW Hot-Swappable Power Modules, operating in redundant configuration to supply W/S load. There should be provision to add 2 x 25 KW Hot Swappable Module onsite in each of the UPS Chassis for connecting more load in future. Make : Eaton, UPS features as under: i). IGBT based rectifier to achieve input THDI < 5% and input power factor of greater than 0.99 at 100% load. True Online Double Conversion (VFI SS 111 as per IEC 62040-3) UPS using PWM IGBT technology UPS system; ii) Fully rated inbuilt static switch at the inverter output. iii). Variable Module Managerial System to increase running load efficiency of complete UPS system. This user programmable software should be able to seamlessly move extra power modules in sleep mode & switch them ON when load increases. iv). UPS Efficiency Should be >95% from 25% to 100% linear load in view of reducing carbon footprint of the proposed data centre. v). Energy Saver Solution Software should be provided with UPS to enable operate UPS @99% efficiency also. This software should be able to operate UPS in bypass mode when the available input power is well conditioned. vi). Fully rated inbuilt static switch at the static bypass line vii). Fully rated Inbuilt Maintenance Bypass Switch within the UPS Chassis for the continuous operation of the load during maintenance. viii). Web-enabled monitoring and management through SNMP protocols for multi-OS environments. ix). RS232/ RS486 port for BMS connectivity through Jbus/Modbus protocol. x). User-friendly 7” LCD Touchscreen interface shall be provided for ease of monitoring UPS Parameters. xi). UPS Front Door should have dust filter at Ait Inlet End to increase overall components reliability. xii). SNMP+MODBUS CARD Shall be provided with Each UPS. xiii). Relay card + Remote Monitoring Panel + CAT 5 Cable for Connectivity between RMP & UPS shall be provided (upto 50 meter per UPS). xiv). High performance Battery Banks comprising of Valve Regulated Lead Acid, maintenance Free batteries of minimum 5years design life to provide 30 minutes backup at 0.9 load power factor load for the supplied power modules. Additionally, each string should have flexibity of operating at lower battery qty (min 10%) in emergency situations. Battery MCCB should be provided externally with each UPS System.Min. Battery Requirement: (Each 200 KW chassis shall have 12V, 150 Ah x 40 Nos. Batteries) Battery Make : Quanta / Exide / Panasonic or Equivalent UPS Make : Eaton, GE, Gutor, Powerware or Equivalent. xv). Battery Accessories for above UPS :Battery MCCB, Closed Battery Cabinets, Battery to battery interlinks using Uninyvin Cable, Battery to UPS DC Cable will be in UPS Vendor scope (1 Set) |
| 102 | Supply & installation of input Panel with Common Bus-bar for Armoured Cable Termination + 2 x 400 Amps TPN MCCB for UNINYVIN Cable terminations (to be installed in UPS Room). |
| 103 | Supply & installation of output Panel with Common Bus-bar for Armoured Cable Termination + 2 x 400 Amps 4pole MCCB for UNINYVIN Cable terminations (to be installed in UPS Room) |
| 104 | Supply & laying of Uninyvin, U-2 Copper Tinned Cable within The UPS room for UPS Input & Output with problem Lugs / Thimbles / Glands as required, in meters Note: Each Run shall be using 2 X U-2 cable. |
| 105 | LT CABELS :- Supply of 1100 volt grade armoured XLPE insulated & PVC sheathed aluminium / copper multicore stranded conductor cables |
| 106 | 3.5 Core 185 Sqmm- Al |
| 107 | 4 core 50 sq mm -copper conductor |
| 108 | 4 core 25 sq mm -copper conductor |
| 109 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required |
| 110 | Above 95 Sqmm and upto 185 Sqmm |
| 111 | Upto 35 Sqmm |
| 112 | Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor Cable of 1.1 KV grade :- |
| 113 | 3.5 Core 185 Sqmm- Al |
| 114 | 4 core 50 sq mm -cu |
| 115 | 4 core 25 sq mm -cu |
| 116 | EARTHING :- Supply & Installation of Advance maintenance free Chemical Gel Earthings of Copper 3 Mtr. long 50 mm Dia filled with good conductive compound welded with the suitable terminal for connecting of your strip or cable along with a highly conductive, non-corrosive, non-magnetic material called EEM-BFC [Ground Resistance Improvement Powder]. The EEM-BFC Compound powder is also put around up to a depth of the electrode. 50kg |
| 117 | Supply Installation of Advance maintenance free Chemical Gel Earthling of GI 3mtr long 50mm Dia filled with good conductive compound welded with the suitable terminal for connecting of your strip or cable along with a highly conductive, non-corrosive, Non-magnetic material called EEM-BFC [Ground Resistance Improvement Powder]. The EEM-BFC Compound powder is also put around up to a depth the electrode electrode. 50kg |
| 118 | Supply and fixing in position the following G.I. / Cu. Tape/ wires including providing all fixing accessories and effecting proper connections |
| 119 | 50 x 6 mm G.I. Tape |
| 120 | 25 x 6 mm G.I. Tape |
| 121 | 50x6 mm Copper |
| 122 | 25 x 6 mm Copper Tape |
| 123 | LIGHTING & POWER WIRING:- Supply and fixing following modular switch / Socket on the existing modular plate & switch box including connections but excluding modular plate etc. :- |
| 124 | 5/6 amp A Swtch |
| 125 | 5 Amp Socket outlet |
| 126 | 15/16 amp A Swtch |
| 127 | 6 pin 15 Amp Socket outlet |
| 128 | Supply and fixing following Modular base & Cover Plate complete:- |
| 129 | 8 Module |
| 130 | 6 Module |
| 131 | 4 Module |
| 132 | 3 Module |
| 133 | 1 or 2 Module |
| 134 | Supply and fixing following Modular GI Box:- |
| 135 | 8 Module |
| 136 | 6 Module |
| 137 | 4 Module |
| 138 | 3 Module |
| 139 | 1 or 2 Module |
| 140 | Supplying and fixing suitable size GI Box with modular plate and cover in front on surface or in recess, including providing & fixing 6 pin 5/6 & 15/16 amp modular socket outlet and 15/16 amp modular switch, connection etc. |
| 141 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. |
| 142 | Copper Cable from UPS Output Panel to Servers Including IP-65 Connector etc. |
| 143 | Wiring for circuit / sub main wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit. |
| 144 | 2x2.5 Sqmm + 1x2.5 Sqmm earth wire |
| 145 | 2x4 Sqmm + 1x4 Sqmm earth wire |
| 146 | 2x6 Sqmm + 1x6 Sqmm earth wire |
| 147 | 2x10 Sqmm + 1x6 Sqmm earth wire |
| 148 | 4x10 Sqmm + 2x6 Sqmm earth wire |
| 149 | 4x16 Sqmm + 2x6 Sqmm earth wire |
| 150 | Supply, Installation, testing & commissioning of LED Profile Light/ LED Fittings etc. For lighting System for the facility. |
| 151 | LED Light 18 Watt ceiling light, Single phase for Office Area Make: Philips, Bajaj, Jainsons or equivalent. |
| 152 | Providing & Fixing of single phase profile light 12 mm dia 12 watt for recepction area Make Philips , Bajaj, Jainsons or equivalent |
| 153 | LED Profile LED 35 mm dia 20 Watt, single phase for hall Make: Philips , Bajaj, Jainsons or equivalent. |
| 154 | Supply installation testing and commissioning of 43 watt LED reccess light fixing on false celliing including all accessories complete as required |
| 155 | Supply installation testing and commissioning of 20 watt LED Cob Light |
| 156 | Providing of Decorative Lights & Timers as per approved of Engineer-in-charge |
| 157 | Supply & Installation of Hanging Lights |
| 158 | Supply & Installation of Wall Lights |
| 159 | Supply & Installation of conseal Floor Lights |
| 160 | Supply & Installation of Decorative lights |
| 161 | Supply & installation of Led Strip light fixing on false celing including all accessories |
| 162 | RACEWAYS CABLE TRAYS AND G.I.PIPES:- Providing and fixing of following sizes of raceway made of 14 gauge GI/MS sheet with all accessories as required suspended from ceiling/ laying under floor including supply & fixing of approved MS angle supports complete as required, and junction boxes to suite the site or as per site requirement complete as required. Separate colour to be considered for electrical and L.V. :- |
| 163 | 200mm x 40 mm (2mm thick cover) |
| 164 | 150mm x 40 mm (2mm thick cover) |
| 165 | 100mm x 40 mm (2mm thick cover) |
| 166 | Supply and fixing of sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required |
| 167 | 25 mm dia |
| 168 | 32 mm dia |
| 169 | 40 mm dia |
| 170 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface / recessed existing raceway / PVC conduit/ PVC flexible conduit, with moduler switch, moduler plat, suitable GI Box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 171 | Supplying and fixing of following ways surface / recess mounting, certical type. 415 V, TPN MCB distribution board of steel, dust protection, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, for mounting MCBs (but without MCBs and incomer) as required. (Note: vertical MCB TPDB is normally used where 3 phase outlets are required). |
| 172 | 12 Way (4+36), Double door |
| 173 | 8 Way (4+24), Double door |
| 174 | Supplying and fixing of following ways single pole and netural, sheet steel, MCB distribution board, 240 V surface / recess complete tinned copper bus bar, neutral link, earth bar, interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator). |
| 175 | 16 Way, Double door |
| 176 | Supplying and fixing 5 A to 32 amp rating, 240/415 V, 10 KA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing & commissioning etc. as required. |
| 177 | Single Pole |
| 178 | Single Pole and netural |
| 179 | Triple Pole and netural |
| 180 | Triple Pole and netural 63A |
| 181 | UPS OUTPUT PANEL INCOMING 400 Amp 4P (36KA) moulded case circuit breaker with operating handle-2 Nos Digital Multifunctional Meter (EM6436) - 2 Nos Digital Amp meter with selector switch & Resin Cast CTs - 2 set Digital Volt meter with selector switch - 2 Set Phase Indication Lights with control MCB - 2 set ON OFF Indication light - 4 Nos Auxiliary Contact Block - 2 Nos Control MCB - 6 Nos BUS BAR Three Phase with neutral Aluminium Bus Bar suitable for 400 Amp of size 50x10mm for phase, 50x6mm for neutral & 25x6mm for earth or equivalent. OUTGOINGS 250 Amp 4P (25KA) moulded case circuit breaker with operating handle - 2 Nos 63 Amp 4P (10KA) MCBs -08 No 40 Amp DP (10KA) MCBs -02 Nos |
| 182 | ISOLATER UNITS INCOMING 250 Amp 4P (25KA) moulded case circuit breaker with operating handle - 1 No. Digital Multifunctional Meter (EM6436) - 1 No. Digital Amp meter with selector switch & Resin Cast CTs - 1 Set Digital Volt meter with selector switch - 1 Set Phase Indication Lights with control MCB - 1 Set ON OFF Indication light - 2 Nos Auxiliary Contact Block - 1 No. Control MCB -3 Nos Surge Arrestor -1 No. Fuse with fuse base - 1 Set BUS BAR Three Phase with neutral Aluminium Bus Bar suitable for 250 Amp of size 30x10mm for phase, 30x6mm for neutral & 19x6mm for earth or equivalent. OUTGOINGS 32 Amp 4P (10KA) MCBs - 14 Nos 63 Amp 4P (10KA) MCBs - 6 Nos |
| 183 | MAIN ISOLATER TO ELECTRICITY BOARD SUPPLY INCOMING 630 Amp 4P (50KA) moulded case circuit breaker with operating handle - 1 Nos Digital Multifunctional Meter (EM6436) - 1 No. Digital Amp meter with selector switch & Resin Cast CTs - 1 Set Digital Volt meter with selector switch - 1 set Phase Indication Lights with control MCB - 1 Set ON OFF Indication light - 2 Nos Auxiliary Contact Block - 1 No. Control MCB - 1 Set |
| 184 | MAIN L.T.PANEL INCOMING FROM TRANSFOMER 800 Amp 4P (50KA) electrical operated draw out type air circuit breaker with O/L, S/C & E/F releases type SR-18G - 1 No. Under voltage release - 1 No. A/M selector switch -1 No. Timer -1 No. Auxiliary contactor - 1 No. Push button - 1 No. Indication lights On,Off - 2 Nos Control MCB - 4 Nos Digital Multifunctional Meter (EM6436) - 1 No. Digital Amp meter with selector switch & Resin Cast CTs - 1 No. Digital Volt meter with selector switch - 1 Set Phase Indication Lights with control MCB - 1 Set CTs For APFC Relay - 1 Set INCOMING FROM D.G.SET 800 Amp 4P (50KA) electrical operated draw out type air circuit breaker with O/L, S/C & E/F releases type SR-18G - 1 No. Under voltage release - 1 No. A/M selector switch - 1 No. Timer - 1 No. Auxiliary contactor - 1 No. Push button - 1 No. Indication lights On,Off - 2 Nos Control MCB - 4 Nos Digital Multifunctional Meter (EM6436) - 1 No. Digital Amp meter with selector switch & Resin Cast CTs - 1 Set Digital Volt meter with selector switch - 1 set Phase Indication Lights with control MCB- 1 set AMF Relay - 1 No. hooter - 1 No. Battery charger - 1 No. Ammeter DC - 1 No. Voltmeter DC - 1 No On Delay Timer - 1 No. A/M selector switch -1 No. Start, Stop push button - 2 Nos EM Push button - 1 No. |
| 185 | Indication lights - 1 Lot Control MCB - 1 Set BUS BAR Three Phase with neutral ALUMINIUM BUS BAR suitable for 1000 Amp of size 100x10mm for phase, 75x10mm for neutral & 38x6mm for earth or equivalent OUTGOINGS 400 Amp 4P (35KA) moulded case circuit breaker with operating handle - 3 Nos Digital Amp meter with selector switch & Resin Cast CTs - 3 Set ON OFF Indication light - 6 Nos Auxiliary Contact Block - 3 Nos Control MCB -2 Nos 500 Amp 3P (35KA) moulded case circuit breaker with operating handle- 1 No. Digital Amp meter with selector switch & Resin Cast CTs-1 Set ON OFF Indication light-2 Nos Auxiliary Contact Block -1 No. Control MCB -1 Set 250 Amp 4P (25KA) moulded case circuit breaker with operating handle -2 Nos Digital Amp meter with selector switch & Resin Cast CTs -2 Set ON OFF Indication light -4 Nos Auxiliary Contact Block-2 Nos Control MCB -2 Set |
| 186 | RAW POWER DISTRIBUTION PANEL INCOMING 250 Amp 4P (25KA) moulded case circuit breaker with operating handle-1 No Digital Multifunctional Meter (EM6436) -1 No Digital Amp meter with selector switch & Resin Cast CTs -1S etc Digital Volt meter with selector switch -1 Set Phase Indication Lights with control MCB-1Set ON OFF Indication light -2 Nos Auxiliary Contact Block -1 No. Control MCB -1 Set BUS BAR Three Phase with neutral ALUMINIUM BUS BAR suitable for 300 Amp of size 30x10mm for phase, 30x6mm for neutral & 19x6mm for earth or equivalent OUTGOINGS 63 Amp 4P (25KA) moulded case circuit breaker with operating handle -4 Nos 63 Amp 4P (10KA) MCBs- 4 Nos 40 Amp DP (10KA) MCBs- 2 Nos |
| 187 | SAFTY ITEMS:- Supplying and fixing 4.5 Kg Clean Agent Fire extinguishers with wall mounting brackets first filling etc. |
| 188 | Supplying and fixing 1000 mm wide 3 mm thick rubber matting (complying with I.S.S.) & suitable to withstand 11 kV as required. |
| 189 | Supplying and fixing standard shock treatment charts in English & Hindi mounted on wooden frame with glass. |
| 190 | Supplying and fixing of danger plate as per approved sample written in English, & Hindi for MV |
| 191 | Supplying First Aid Box for HV complete as approved by St. John ambulance or Indian Red Cross. |
| 192 | Supplying and fixing fire buckets each painted red with fire written out complete with sand filling, floor/wall mounting brackets complete. |
| 193 | Supplying LT rubber gloves |
| 194 | STEEL STRUCTURE |
| 195 | SERVER EARTHING CABLES:- Supply, laying, testing and commissioning of following sizes of 1.1 KV XLPE insulated Copper conductor cables overhead cable trays or over MS supports in masonry trenches including providing the MS supports and clamps for fixing to supports in an approved manner complete as required and as per specifications. (Length may vary as it depend on Earth Pit Location) |
| 196 | 1 x 95 sq. mm single core copper cable for earthing.(UPS) |
| 197 | 1 x 25 sq. mm single core copper cable for earthing.(Server) |
| 198 | Supply and making terminal joints for the following sizes of 1.1. KV XLPE insulated Copper conductor cable including providing terminal lugs, crimping the joints effecting terminal connections to the equipment complete as required including providing single compression glands. |
| 199 | 95 Sq. mm single core copper cable (armoured) for earthing.(UPS) |
| 200 | 25 Sq. mm single core copper cable (armoured) for earthing.(UPS) |
| 201 | PART-II FIRE SYSTEM FM 200 (HFC 227ea) GAS SUPPRESSION SYSTEM For suitable location with its accessories and control including testing and commisioning UPS ROOM 1 No. 80 Ltr. Seamless CCOE Cylinder with Sinorix VSB 33 Valve 1 No. Pressure gauge + Low Pressuress Supervisory Switch 1 No. Electromagnetic Actuator 1 No. Manual Actuator 1 No.Pneumatic Actuator 1 No. Flexible Discharge Hose 2 Nos. Flexible Actuation Hose 1 Set Warning Sign Board 68 Kgs. Sinorix 227 Gas (1W+1S) (01 Set) Check Valve (02 Each) Discharge Pressure Swtich (01 Each) Seamless Manifold and Cylincer Rack with Strips (01 Each) Discharge Nozzles (04 Each), M.S. Seamless pipes as per ASTM A 106 Gr. B,schedule 40 with necessary fitting, 80 mm dia (05 Mtr), 65 mm dia (03 Mtr), 50 mm dia (06 Mtr), 40mm dia (02 Mtr), 32mm dia (02 Mtr), 25mm dia (02 Mtr), 20mm dia (01 Mtr), 15mm dia (01 Mtr), Detection and control Equipment 02 Zone Gas Release Panel 01, Multi Cirteria optical Smoke Detector 08 No, Electonic Hooter 01 No, Abort Switch 01 No, Response Indicator, Supply, laying tersting & Commsioning of 2 core x1.5 Sq.mm copper armoured cable accessories (100 Mtr), Clean Fire extingusher 4Kgs (02 No), Server Room 01 No 80/100 ltr, Seamless CCOE Cylinder with Sinorix VSB 33 Valve, 01 No Pressure gauge + low Pressure Supervisory switch, 01 No Electromagnetic Actuator, 01 No Manual Actuator, 01 No Flexible Discharge Hose, 02 No Flexible Actuation Hose, 01 Set Warning Sign Board, 68 Kgs Sinorix 227 Gas (1w+1S), Check Valve 02 Each, Discharge Pressure Seitch 01 Each, Seamless Manifold and Cylincer Rack with Strips 01 Each, Discharge Nozzles 06 Each, M. S Seamless pipes as per ASTM A 106 Gr. B, Schedule 40 with necessary fittings 80mm dia 05 Mtr, 65mm dia 05 Mtr, 50mm dia 6 Mtr, 40mm dia 2 Mtr, 32mm dia 2 Mtr, 25mm dia 2 Mtr, 20mm dia 01 Mtr, 15mm dia 01 Mtr, Detection and Control Equipment 02 Zone Gas Release Panel 01 Each, Multi Criteria Optical Smoke Detector 12 No, Abort switch 01 No, Response Indicator 04 No, Supply, laying testing and commssioning of 2 core x1.5 Sq.mm copper armoured cable acessories 200 Mtr, Clean Fire extingusher 4kgs 02 Each. |
| 202 | PART-III AIR CONDITIONING SYSTEM Supply, Installation, testing & commissioning of following nominal capacity Air Cooled 100% Inverter Variable based refrigerant flow volume Scroll/ Rotary modular type air- conditioning system. The PCB Chamber of the outdoor unit shall be refrigerant cooled, suitable for operation on 415 V, 50 Hz AC Supply. The units shall have cooling and heating type, low noise condenser fans, auto address setting, auto check function for connection error and complete outdoor units with individual controller and with Outdoou unit Connection Y Joints and fittings etc. as per quantity given below i/c powder coating of all metalic encloser. The static pressure of the outdoor unit shall be more then 75 Pa to avoid hot air recirculation. The unit shall be able to operate upto to 48°C in cooling mode. The COP of each refrigerant circuit system mentioned below shall be 3.7 at 100% laod and 7.10 min. at 50% load, at AHRI conditions in cooling mode. The unit shall also have feature automatically modulate the evaporative temperature between 6 deg C to 11 deg C with respect to load for better comfort and energy efficiency.Nominal Capacity in HP as stated below: |
| 203 | 16 HP |
| 204 | 20 HP |
| 205 | Supply, installation, testing and commissioning of following minimum capacityround flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan. drain pump, cassette grill, insulation, necessary supports, vibration isolation, cordless remote control etc, suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. All 4 louvers of the unit shall be independently adjustable for positiion as per user preference. |
| 206 | 2.0 TR CASSETTE UNIT |
| 207 | 3.0 TR Cassette Unit |
| 208 | 3.98 TR Cassette Unit |
| 209 | Supply, installation, testing and commissioning of following minimum capacityround flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan. drain pump, cassette grill, insulation, necessary supports, vibration isolation, cordless remote control etc, suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. All 4 louvers of the unit shall be independently adjustable for positiion as per user preference. |
| 210 | 2.0 TR HI-Wall Unit |
| 211 | SITC of Refne Joint for VRV Indoor Unit |
| 212 | REFRIGERANT PIPING Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class‐O tubular insulation/with Class‐O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required: |
| 213 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2mm with 19 mm thick insulation. |
| 214 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation. |
| 215 | 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation. |
| 216 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation. |
| 217 | 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation. |
| 218 | 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation. |
| 219 | 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation. |
| 220 | DRAIN PIPING:- SITC of PVC Drain Water Piping complete with fittings (elbows, tees, reducers, sockets etc.), supports, jointing and any other item required to make the system complete. Outer Diameters of Pipes in mm as indicated below: |
| 221 | 25 mm ( with 6 mm Class‐ O Nitrile Rubber/ XLPE) |
| 222 | 32 mm ( with 9 mm Class‐ O Nitrile Rubber/ XLPE) |
| 223 | CONTROL & TRANSMISSION WIRING :- Providing and fixing control cum transmission wiring of 2 core x 1.5 Sq.mm copper in suitable conduits between indoor and there wire Remote. |
| 224 | Providing and fixing Power Cable of 3 core x 2.5 Sq.mm copper between indoor and Outdoor.Power Cable |
| 225 | Providing and fixing Power Cable of 4 core x10 Sq.mm copper for Outdoor. |
| 226 | Fabrication, Supplying, Installation, Testing and commissioning of Outdoor type Double door feeder pillar, front & back openable MS sheet Cubical Panel of suitable size made out of 2.0 mm thick CRCA sheet duly powder coated with 7 Tank process having 250 Amp TPN alluminium bus bar complete with interconnections and control wiring etc complete as required with following switchgear & accessories. i/c base frame made out of 50mmx50mmx6mm (thick) angle iron duly grouted in cement concrete in ground upto suitable depth & above ground upto 45 cm etc. as reqd. Incomer 250 Amp, 36 kA, FP MCCB with ROH mechanism & 1 set of RYB phase indicating lights 1 set of ring type, tape wound, current transformers of ratio Ammeter (0‐250Amp) Digital with selector switch Voltmeter (0‐500) Digital with selector switch 2A SPMCB C‐Curve 10KA Outgoing 25 A, TPN MCB,10 KA (5W+1S) 25 A, TPN ELCB,300mA (5 W+1S) 16A, DP MCB,10 KA (13 W+2S) |
| 227 | Fabrication, Supplying, Installation, Testing and commissioning of Outdoor type Double door feeder pillar, front & back openable MS sheet Cubical Panel of suitable size made out of 2.0 mm thick CRCA sheet duly powder coated with 7 Tank process having 400 Amp TPN alluminium bus bar complete with interconnections and control wiring etc complete as required with following switchgear & accessories. i/c base frame made out of 50mmx50mmx6mm (thick) angle iron duly grouted in cement concrete in ground upto suitable depth & above ground upto 45 cm etc. as reqd. Incomer 320 Amp, 36 kA, FP MCCB with ROH mechanism & 1 set of RYB phase indicating lights 1 set of ring type, tape wound, current transformers of ratio Ammeter (0‐400Amp) Digital with selector switch Voltmeter (0‐500) Digital with selector switch 2A SPMCB C‐Curve 10KA Outgoing 63 A, TPN MCB,10 KA (6W+1S) 63 A, 4Pole,ELCB,300mA (6 W+1S) 16A, DP 1Vice to A(t3 W+zsi) |
| 228 | S/I/T/C of 380 KVA Silent DG Set comprising of cummins Engine 415V or equivalent with all accessories |
| 229 | EARTHING:- Supply & Installation of Advance maintenance free Chemical Gel Earthings of Copper 3 Mtr. long 50 mm Dia filled with good conductive compound welded with the suitable terminal for connecting of your strip or cable along with a highly conductive, non-corrosive, non-magnetic material called EEM-BFC [Ground Resistance Improvement Powder]. The EEM-BFC Compound powder is also put around up to a depth of the electrode. 50kg |
| 230 | Supply Installation of Advance maintenance free Chemical Gel Earthling of GI 3mtr long 50mm Dia filled with good conductive compound welded with the suitable terminal for connecting of your strip or cable along with a highly conductive, non-corrosive, Non-magnetic material called EEM-BFC [Ground Resistance Improvement Powder]. The EEM-BFC Compound powder is also put around up to a depth the electrode electrode. 50kg |
| 231 | Supply and fixing in position the following G.I. / Cu. Tape/ wires including providing all fixing accessories and effecting proper connections |
| 232 | 50 x 6 mm G.I. Tape |
| 233 | 50x6 mm Copper |
| 234 | LT CABELS :- Supply of 1100 volt grade armoured XLPE insulated & PVC sheathed aluminium multicore stranded conductor cables |
| 235 | 3.5 Core 300 Sqmm- Al |
| 236 | End Terminations:- Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor Cable of 1.1 KV grade :- |
| 237 | 3.5 Core 300 Sqmm- Al |
| 238 | Supply & fixing of Gyser (Water Heater) |
| 239 | Supply & fixing of Exhaust Fan 300mm |
| 240 | Supply & fixing of Wall Fan 400mm Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail