| 1 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, ceiling roses, pendants, regulators, sockets etc but excluding DBs, light fittings etc and making good disturbed surfaces of walls, floors etc. and matching with existing surface all as specified and as directed. |
| 2 | M&L for point wiring with two runs of 1.5 sqmm for phase and neutral, single core, multistranded copper conductor cable of 1100 Volts grade, conforming to IS-694 1990, PVC insulated and unsheathed , FRLS cable laid / fixed and including concealed in PVC rigid conduit on walls/ceiling alongwith 1.5 Sqmm copper conductor cable (multistranded) PVC insulated and unsheathed FRLS cable as earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including PVC modular boards and plate for mounting switches, sockets, fan regulators, accessories etc as specified and directed for one light point or one fan point controlled by one, one way switch complete all as specifed and as directed. NOTE: 1.Proper colour coding shall be adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black). 2. All points shall be earthed up to fixtures i.e holders,tube lights,all lights,ceiling lights,bulkhead lights,bldg security lights etc. |
| 3 | All as per serial item No. 2 here-in-before but for one 5 Amp, 3 pin socket outlet point on same board with other switches including earth wire as specified. |
| 4 | All as per serial item No. 2 above but for one 3 pin socket outlet, 5 Amps on independent board but below the switch board of light points in the same vertical plane/horizontal plane, with cables, 1.5 sq. mm size. |
| 5 | All as per serial item No. 2 here-in-before but on independent board. |
| 6 | All as per serial item No. 2 here-in-before but for one bell/buzzer point controlled by one push button on the same board with other switches or independent. |
| 7 | All as per serial item No. 2 here-in-before but for one light point controlled by 2 way switches. |
| 8 | All as per serial item No. 2 here-in-before but with 2.5 Sqmm, PVC copper stranded cable FRLS type for phase, neutral and earth for one 15 Amp, 6 pin socket on independent board. |
| 9 | All as per serial item No. 2 above but for one 3 pin socket outlet, 15 Amps on independent board but below the switch board of light points in the same vertical plane/horizontal plane, with cables, 2.5 sq. mm size. |
| 10 | S&F modular switch one way, 6 Amp, one module, 230V all as specified and directed. |
| 11 | S&F modular switch one way, 16 Amp, one module, 230V all as specified and directed. |
| 12 | S&F modular switch, piano type, 6 Amp, single pole, two way, one module, 230V all as specified and as directed. |
| 13 | S&F modular bell push, 6 Amp, one module, 230V all as specified and directed. |
| 14 | S&F modular socket, 6A, 3 pin combined 2 module, 230V all as specified and directed. |
| 15 | S&F modular socket, 6A/16A, 3 pin combined 2 module, 230V all as specified and directed. |
| 16 | S&F electric door bell, 230 V, multi music type, ISI marked all as specified and as directed. |
| 17 | S&F lamp holder insulated, PVC / polycarbonate /bakelite body complete all as specified and as directed. |
| 18 | S&F ceiling rose surface bakelite 65x50mm three terminal complete all as specified and as directed. |
| 19 | M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sqmm for phase and neutral, single core, multistranded copper conductor cable of 1100 Volts grade,conforming to IS-694 1990, PVC insulated and unsheathed , FRLS cable drawn through and including PVC casing and caping (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, coloumns/ beams alongwith 1.5 Sqmm copper conductor cable (multistranded) PVC insulated and unsheathed FRLS cable as earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including PVC folding boards for mounting switches, sockets, fan Regulators, accessories etc as specified and directed for one light point or one fan point controlled by one, one way switch NOTE: 1.Proper colour coding shall be adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black). 2. All points shall be earthed up to fixtures i.e holders,tube lights,all lights,ceiling lights,bulkhead lights,bldg security lights etc. |
| 20 | All as per serial item No. 19 above but for one 3 pin socket outlet, 5 Amps on same board with other switches. |
| 21 | All as per serial item No. 19 above but for one 3 pin socket outlet, 5 Amps on independent board but below the switch board of light points in the same vertical plane/horizontal plane, with cables, 1.5 sq. mm size. |
| 22 | All as per serial item No. 19 above but for one light point controled by two, two way switch. |
| 23 | All as per serial item No. 19 above but for one bell point controlled by one bell push. |
| 24 | All as per serial item No. 19 above but for one 3 pin socket outlet, 5 Amps on independent board with cables, 1.5 sq. mm size. |
| 25 | All as per serial item No. 19 here-in-before but with 2.5 Sqmm, PVC copper stranded cable FRLS type for phase, neutral and earth for one 15 Amp, 3 pin socket on independent board. |
| 26 | All as per serial item No. 19 above but for one 3 pin socket outlet, 15 Amps on independent board but below the switch board of light points in the same vertical plane/horizontal plane, with cables, 2.5 sq. mm size. |
| 27 | S&F switch piano, flush button, 6 Amp, single pole, one way, 230 volts, white finish, all as specified & as directed. |
| 28 | S&F socket outlet, flush type, 3 pin, 6 Amp, multipurpose, 230 volts, single pole, one way all as specified & as directed. |
| 29 | S&F switch socket combination, flush type, 3 pin, 6 Amp, multipurpose, 230 volts, single pole, one way, all as specified & as directed. |
| 30 | S&F switch socket combination, multipurpose, flush type, 2 in 1 type (3 pin ) 6/16 Amps, 230V, AC. all as specified & as directed. |
| 31 | S&F lamp holder, angle/ batten type, PVC/Polycarbonate type with back plate, suitable for batten fittings all as specified & as directed. |
| 32 | S&F ceiling rose, surface PVC 50mm dia, 3 terminals including PVC mounting block white/ivory finish all as specified & as directed. |
| 33 | S&F bell push, flush type, 6 Amp, single pole, 230 volts, white finish all as specified & as directed. |
| 34 | S&F bell, AC, 230 volts, single phase complete all as specified and as directed. |
| 35 | S&F in repairs, MCB, SPN 40 to 63 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and directed. |
| 36 | S&F in repairs, single pole & neutral DB, 4 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed. |
| 37 | S&F in repairs, single pole & neutral DBs, 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed. |
| 38 | S&F in repairs, factory made, sheet steel distribution boards, TPN, 4 Way, protection class IP-43 with min 100 Amp rating copper bus bar, provision for FP MCB as incomer and SP MCBs as outgoing complete complete all as specified and as directed . |
| 39 | S&F in repairs, MCCB four pole 63A, Icu16KA, thermal magnetic, 415v AC complete all as specified and as directed. |
| 40 | S&F in repairs, MCCB four pole 100A, Icu16KA, thermal magnetic, 415v AC complete all as specified and as directed. |
| 41 | S&F in repairs, MCBs, SP 6 to 32 Amps, 10 KA, IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 42 | S&F in repairs, MCB, SPN 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and directed. |
| 43 | Supply and fixing LED round/square shape 6 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 44 | Supply and fixing LED round/square shape 12 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 45 | Supply and fixing LED round/square shape 15 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 46 | S&F in repairs, 600 mm x 600 mm size, ultra slim, recess mounted LED luminaire of capacity 36 watt, with driver, for soft glare free light, AC 230 volt complete with all acessories and connections, complete all as specified & as directed. |
| 47 | S & F LED Tube light fitting 20 Watt decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, enviromental friendly energy efficiency with LED light source 6000k with all accessories including its connection with 3 core seathed copper conductor cable of size 0.5 sqmm with complete with all as specified and directed by Engineer-in-charge. |
| 48 | S & F LED Tube light fitting 10 Watt decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, enviromental friendly energy efficiency with LED light source 6000k with all accessories including its connection with 3 core seathed copper conductor cable of size 0.5 sqmm with complete with all as specified and directed by Engineer-in-charge. |
| 49 | Surface mounted, decorative round plastic bulk head LED luminaire comprising of high brightness LED's, IP54 protection, 10 watt, 6000K complete fitting with LED lamp, driver and all other fixing accessories including electric connection connecting with using flexible copper wire twin core upto ceilling rose/connector including taking down old unserviceable light fitting any type complete all as specified and as directed by Engineer-in- Charge. |
| 50 | Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp all fittings and accessories complete all as directed by Engr-in-Charge. |
| 51 | S&F in repairs, security light fitting of building with single piece new generation energy savng and environmental friendly, long life, LED 30W, made up of pressure die cast aluminium housing with acrylic covers as diffuser with IP66 protection and impact resistance of IK07 including one bracket made of light grade GI Pipe 25 mm dia, 1.5 mtr long, fixed to wall/ pole with two clamps made out of mild steel flat iron 40 mm x 5 mm and connect to nearest electric supply by two core 1.5 sqmm aluminium cable all as specified and as directed. Make : Havells Cat No LHEXAY7PN6K030 or equivalent model of make Philips / Crompton Wipro/Surya |
| 52 | M&L in repairs for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including 4mm dia GI wire upto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 15mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal,salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified and as directed. |
| 53 | S&F in repairs, LED edge lit panel drivers of capacity 18 W to 36 W with universal connector for easy installations complete all as specified and as directed. |
| 54 | S&F in repairs, LED edge lit panel drivers/post top lamp of capacity 42 W with universal connector for easy installations complete all as specified and as directed. |
| 55 | S&F in repairs PVC casing caping 32 mm with fixing accessories such as complete,lock nuts, saddles hook etc of adequate size, fixed in replacement complete all as specified and directed by Engineer in charge. |
| 56 | S&F in repairs PVC casing caping 100 mm with fixing accessories such as complete,lock nuts, saddles hook etc of adequate size, fixed in replacement complete all as specified and directed by Engineer in charge. |
| 57 | S&F in repairs, PVC rectangular box of 100 mm x 100mm x 50 mm deep, for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc. all as specified and as directed. |
| 58 | S&F in repairs, PVC rectangular box of 175 mm x 100mm x 50 mm deep, for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc. all as specified and as directed. |
| 59 | S&F in repairs, PVC rectangular box of 200 mm x 150mm x 50 mm deep, for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc. all as specified and as directed. |
| 60 | S&F in repairs, PVC rectangular box of 250 mm x 200mm x 50 mm deep, for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc. all as specified and as directed. |
| 61 | S&F in repairs, PVC rectangular box of 350 mm x 300mm x 50 mm deep, for mounting of switch, sockets, fan regulators, etc.complete with screws and washers, etc. all as specified and as directed. Note Cutting of board for mounting switch,sockets, fan regulators etc. shall be as per site requirement. |
| 62 | S&F in repairs, modular cover plate frame, 2 module complete all as specifed and as directed. |
| 63 | S&F in repairs, modular cover plate frame, 4 module complete all as specifed and as directed. |
| 64 | S&F in repairs, modular cover plate frame, 6 module complete all as specifed and as directed. |
| 65 | S&F in repairs, modular cover plate frame, 8 module complete all as specifed and as directed. Note :(i) Item shall be executed to attend day to day complaints. (ii) Burnt/damaged fitting only shall be replaced.(iii) Wiring is not included in the item. |
| 66 | S&F in repairs, PVC insulated, sheathed cable with stranded aluminium conductor service cable of size 4 sqmm, two core complete all as specified and as directed. |
| 67 | S&F in repairs, PVC insulated, sheathed cable with stranded aluminium conductor service cable of size 6 sqmm, two core complete all as specified and as directed. |
| 68 | S&F in repairs, PVC insulated, sheathed cable with stranded aluminium conductor service cable of size 10 sqmm, two core complete all as specified and as directed. |
| 69 | S&F repairs 5/6 Amp plug top 230 volts, single pole, white/ivory finish all as specified & as directed. |
| 70 | S&F repairs 15/16 Amp plug top 230 volts, single pole, white/ivory finish all as specified & as directed. |
| 71 | S&F in repairs, sheet metal enclosures with plug socket, single pole and neutral with two pin and earth plug with one MCB of 20 Amps (SP) complete all as specified and as directed. |
| 72 | M & L for sub main wiring with 2 runs of 4 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm dia PVC conduit conforming to IS-9537 / suitable size casing caping (ISI marked) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduitcomplete all as specified and as directed. |
| 73 | M & L for sub main wiring with 2 runs of 6 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm dia PVC conduit conforming to IS-9537 / suitable size casing caping (ISI marked) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduitcomplete all as specified and as directed. |
| 74 | M & L for sub main wiring with 2 runs of 10 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm dia PVC conduit conforming to IS-9537 / suitable size casing caping (ISI marked) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 10 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduitcomplete all as specified and as directed. |
| 75 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm. Make : Crompton Greaves, Model : BRISK AIR , or equivalent in USHA/Bajaj. Note: Old UNSV exhaust fans will be deposited to MES Store. |
| 76 | Taking down of exhaust fan upto 450/300mm sweep, opening, replacement of unserviceable accessories, servicing, oiling, greasing, complete overhauling of fan and re-assembling and testing complete for efficient functioning after fixing / hanging in position from ceiling rose to fan complete as directed. (Note : gun metal bush, bearing will be measured and paid under relavant item here-in-after). |
| 77 | S & F gun metal bush of sizes suitable for exhaust fan upto 450 mm sweep. |
| 78 | S & F ball bearing No 6203 suitable for fan of existing make type & sweep complete Make:- NBC/SKF/TATA |
| 79 | S & F unserviceable capacitor/ tightening the loose connections if any including testing complete all as directed by Engr-in-Charge. |
| 80 | M & L for painting of exhaust fan carefully with one coat of synthetic enamel paint including filling cavities with filler after cleaning all dust etc complete all as directed. |
| 81 | M&L for shifting of exhaust fan from one place to another including making hole at new place and filling of hole at old place including all necessary electric connection, brick work, plastering and 2 coat of painting of size 150, 200, 250 and 300mm dia all as specified and directed. |
| 82 | S & F INVETER LED Tube light fitting 20 Watt with square profile and polycarbonate channel. lITHIUM Ion battery with charging time 8 to 10 hrs and back up time upto 4 hrs LED light source 6500k with uniform light output,with all accessories including its connection with 3 core seathed copper conductor cable of size 0.5 sqmm with complete with all as specified and directed. |
| 83 | S&F in repairs, LED 9W Bulb, 230 Volts AC supply, all as specified and directed. |
| 84 | S&F in repairs, LED 9W Inverter Bulb, 230 Volts AC supply, all as specified and directed. |
| 85 | Taking down carefully electric storage type water heater (Geysers) of any make and any capacity from its mounting place opening for inspection compete Including back plate heating element inner copper tank etc. De-scaling back plate and heating element by cleaning with Sulfuric acid/ de-scaling compound and re-assembling of Geysers after repairs carrying out and re-fixing in same position (Replaced items such as spares measured and paid separately)in relevent item including making good to walls with CM (1:3) or PCC (1:2:4) and plastering the wall surfaces with CM 1:6 and replacement of old nuts, bolts and rubber gasket etc all as directed by the Engineer-in Charge. Note :- Any type of rubber gasket , rubber washer, screws , insulator tape required in work deem to be included in the rate. |
| 86 | All as per item No 85.00 herein before but for descaling / cleaning the inner tank including denting and brazing the leakage joints / points till the leakage stop including carrying out minor repair of outer body surface, bottom and top cover complete all as specified and as directed. Note :- Any damage if occured during the process of cleaning the geysers will be made good by contractor at no extra cost. |
| 87 | M&L for 1.5 KW capacity Heating Element, triangular type including making electrical connection incl taking down old u/s heating element complete all as directed by the Engineer-in-Charge. |
| 88 | All as per item Srl No 87.00 but of capacity 2.0 KW complete all as specified and directed. |
| 89 | Supply & fixing PVC connection heavy duty with brass/PTMT nuts of reqd length not exceeding 300 mm with rubber & PVC washer suitable for 15 mm bore GI pipe complete for cold water.incl taking down old u/s connection complete. |
| 90 | Supply & fixing hot water outlet connection made of brass chromium plated with Union rubber washer suitable for 15 mm bore GI pipefor hot water incl taking down old u/s item complete. |
| 91 | Supply & fix in replacement of thermostat (automatic cut of) of existing type & make, 15 Amps, 230/250 volts AC ISI marked complete. |
| 92 | Supply & fix in replacement of indicator lamp assembly LED type RED/GREEN for geyser complete. |
| 93 | Supply and fix electric water heater,storage type steel body and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece including anchoring bolts and making connection and testing complete all as specified and directed. Please Enable Macros to View BoQ information |
| 94 | Supply and fix electric water heater,storage type steel body and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece including anchoring bolts and making connection and testing complete all as specified and directed. Please Enable Macros to View BoQ information |