| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as directed by Engineer-in-Charge. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layersnot exc 25 cm in soft/loose soil complete all as specified. |
| 3 | Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and as directed. |
| 4 | Taking up or down steel tubing 15mm bore dia and connections,including cleaning for refixing or removal to store and refixing steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed by Engr-in-Charge.Note : Excavation and earth work shall be measured and paid separately. |
| 5 | All as per item No 04 above but 25 mm bore dia. |
| 6 | All as per item No 04 above but 40 mm bore dia. |
| 7 | All as per item No 04 above but 50 mm bore dia. |
| 8 | All as per item No 04 above but 80 mm bore dia. |
| 9 | S&F 20 mm dia bore steel water tubing, medium grade, galvanised, with all fitting; laid in trenches including taking up or down steel tubing and connections, including removal to store complete all as specified and directed by Engr-in-Charge. |
| 10 | All as per item no 09 above but 25 mm bore dia. |
| 11 | All as per item no 09 above but 40 mm bore dia. |
| 12 | All as per item no 09 above but 50 mm bore dia. |
| 13 | All as per item no 09 above but 80 mm bore dia. |
| 14 | All as per item no 09 above but 100 mm bore dia. |
| 15 | Supply and fixing 1000 litres of capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling water tanks and removing to store complete all as specified and directed by Engr-in-Charge. |
| 16 | All as per item no 15 above but capacity 750 ltr. |
| 17 | All as per item no 15 above but capacity 500 ltr. |
| 18 | Supply and fixing in repairs Gun-metal, globe or gate valves, with iron wheel head, screwedboth ends for iron pipe of 50 mm dia and fixed complete all as directed. |
| 19 | Supply and fixing in repairs Gun-metal, globe or gate valves, with iron wheel head, screwedboth ends for iron pipe of 40 mm dia and fixed complete all as directed. |
| 20 | Supply and fixing in repairs Gun-metal, globe or gate valves, with iron wheel head, screwedboth ends for iron pipe of 25 mm dia and fixed complete all as directed. |
| 21 | Supply and fixing in repairs Gun-metal, globe or gate valves, with iron wheel head, screwedboth ends for iron pipe of 20 mm dia and fixed complete all as directed. |
| 22 | M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 and painting with two coat of black bitiminious paint over a coat of red oxide primer including dismanting of old unserviceable existing staging complete all as specified by Engr-in-Charge.Make : TATA / SAIL / JINDAL |
| 23 | M&L for cement concrete type C2 (1:3:6) (40mm graded aggregate in foundations, filling and mass concrete including demolition of old existing cement concrete complete all as specified by Engr-in-Charge. |
| 24 | M&L for Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, complete all as specified and as directed. |
| 25 | M&L PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) water troughs and the like including weathering, slightly rounded or chamfered angles and throating including extra using waterproofing compound including dismanting of old existing concrete complete all as specified by Engr-in-Charge. |
| 26 | M&L 15 mm thick rendering in cement mortar (1:6) on fair faces of brick or concrete surfaces, rendering finished even and smooth (without using extra cement ) including Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified by Engr-in-Charge. |
| 27 | M&L for Pre-cast cement concrete type C1 (1:3:6) (20mm graded aggregate) block masonry with solid blocks, exc. 10 cm in width and setting in mortar (1:6) including dismanting of old existing block masonry complete all as specified by Engr-in-Charge. |
| 28 | Construction of valve pit of size 110 x 90 x 100 cm internal dimensions with 100 mm thick PCC (1:4:8) type D2 (using 40 mm graded broken stone aggregate sub base of floor, 50 mm PCC (1:2:4) type B-1 ( using 20 mm graded crushed stone aggregate) in floor finished even and fair without using extra cement one brick thick brick work in CM (1:4) rending 15 mm thick plaster in CM (1:4) including 3 mm thick MS sheet pit cover fixing with angle iron frame 40x40x6 mm thick complete with looking arrangement having provision of lifting handle including 2 coats of synthetic enamel paint over one coat of red oxide primer to steel surface and excavation in soft/loose soil, returning filling and removal of surplus soil up to 50 mtr distance complete and all as specified dismentling old valvepit chamber accessories and deposited to store Yard for futher disposal. |
| 29 | Construction of valve pit of size 90 x 90 x 100 cm internal dimensions with 100 mm thick PCC (1:4:8) type D2 (using 40 mm graded broken stone aggregate sub base of floor, 50 mm PCC (1:2:4) type B-1 ( using 20 mm graded crushed stone aggregate) in floor finished even and fair without using extra cement one brick thick brick work in CM (1:4) rending 15 mm thick plaster in CM (1:4) including 3 mm thick MS sheet pit cover fixing with angle iron frame 40x40x6 mm thick complete with looking arrangement having provision of lifting handle including 2 coats of synthetic enamel paint over one coat of red oxide primer to steel surface and excavation in soft/loose soil, returning filling and removal of surplus soil up to 50 mtr distance complete and all as specified dismentling old valvepit chamber accessories and deposited to store Yard for futher disposal. |
| 30 | Supply & Fix new CI Sluice valve 100mm dia class PN 1.6 with stainless steel spindle confirming to ISI including jointing material nut bolts packing including dismantling / disconnecting unserviceable sluice valve assembly complete by removing old nut bolts packing sheet etc all as directed by Engineer In-charge. |
| 31 | Supply & Fix new CI Sluice valve 80mm dia class PN 1.6 with stainless steel spindle confirming to ISI including jointing material nut bolts packing including dismantling / disconnecting unserviceable sluice valve assembly complete by removing old nut bolts packing sheet etc all as directed by Engineer In-charge. |
| 32 | M& L for cutting of existing steel tubing for alterations or additions (each cut measured) and inserting new Tee, bend, elbow etc 25 to 40 mm dia GI pipe complete all as specified and directed by Engr-in-Charge. |
| 33 | M& L for cutting of existing steel tubing for alterations or additions (each cut measured) and inserting new Tee, bend, elbow etc 50 to 80 mm dia GI pipe complete all as specified and directed by Engr-in-Charge. |
| 34 | Disconnecting existing tanks of capacity in litres exc 500 & n exc 1000, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in old or position complete all as specified and as directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| 35 | Disconnecting existing tanks of capacity in litres exc 500 & n exc 1000, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in old or position complete all as specified and as directed by Engr-in-Charge. Please Enable Macros to View BoQ information |