|
| 1 | 1. Clearing and GrubbingClearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be use dor auctioned, upto a lead of 1000 m Including removal and disposal of top organic soil not exceeding 150 mm in thickness asper Technical Specification Clause 201. I) By Manual MeansA) In area of non thorny jungle |
| 2 | 2.E/W in CoreConstruction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto p g q p 1000 m as per Technical Specification Clause 301.5i) Private Land |
| 3 | 3. E/W in Sub-Grade and Shoulder Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.i) Private land |
| 4 | 4. G.S.B. 15 cm thickConstruction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix inplace method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.ii) For grading II materials |
| 5 | 5. CD Work: Construction of RCC Slab Culvert 4.00m SPan at Ch-1400.00m 1 no.Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.i) Ordinary SoilUpto 3 m depth |
| 6 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause802, 803, 1202 & 1203A. With crushed StoneI. PCC grade M10Nominal mix 1:3:6 |
| 7 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204I. P.C.C grade M15I. Nominal mix (1:2.5:5) |
| 8 | Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5A. With crushed stoneI) R.C.C grade M 20iii) For design mix RCC M 20 |
| 9 | Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3A With crushed stone |
| 10 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
| 11 | Drainage spouts complete as per drawing and technical specifications Clause 1209 |
| 12 | Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204 3 8 |
| 13 | Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/ THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses1002, 1005, 1010 & 1202 |
| 14 | Construction of R.C.C. railing of M25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical post not to exceed 2000 mm as per drawing and technical specifications clauses 800, 900, and 1208.3 Please Enable Macros to View BoQ information |