| 1 | Providing and laying D.P.C. 40 mm thick with cement concrete consisting of( 1:2:4) cement , Coarse sand and 10mm grade stone grit and including water proofing material as directed by the Engineer-In -Charge in the proportion as specified by the manufacturer. |
| 2 | Dismantling door and windows chaukhat with hold fast i/c stacking material within 60 m |
| 3 | Dismantling Brick work in cement mortar i/c staking of material within a distance of 60m.as per E/C |
| 4 | Cement plaster 12 mm thick on brick work in cement mortar 1cement : 4 coarse sand. |
| 5 | Providing and laying Vitrified tiles in floor of 600 x 600mm sizes (thickness 10mm), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in desired colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, including grouting of joints. |
| 6 | Providing and fixing 1st quality ceramic glazed floor/wall tiles conforming to IS :15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 7 | Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 8 | Providing and fixing 5.5 mm thick float glass panes shutters of aluminium Z-section door,window and ventilator |
| 9 | S/F Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia.wire and 1.4mm wide aperture with matching wood beading etc complete. |
| 10 | Providing and fixing ISI marked flush doors,shutters conferming of I.S. 2202 part-1 decorative type core of block board construction with frame of 1st class hard wood & well matched teak 3 ply veening with vertical grains or cross bend & face vaneers on both face of shutters i/c isi marked stainless steel butt hinges with nessesary screw. |
| 11 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade. Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand & manufacturer. |
| 12 | Distempering (First coat) with oil bound distemper of approved brand and manufacture and of requred shade over and including a priming coat with cement primer of approved brand and manufacture such as Berger, J & N. Shalimar Asian paints etc. after thoroughly brushing the surface free from mortar, dropping and ay foreign material and also including preperation of surface even with plaster of approved synthetic material and sand prepared smooth with cost of all material, labour T & P Etc. complete. |
| 13 | Finishing walls with Acrylic smooth exterior paint of required shade new work two or more coat applied @ 1.67 litr./10 sqm over and i/c priming coat of exterior primer applied @2.20 Kg/sqm supply of all labour material & T&p required for proper complition of work. |
| 14 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete supply of all labour material and T&P required for proper completion of work for all heights. |
| 15 | Earth work in foundation in dry ordinary soil (loam clay or sand) including lift upto 1.5m and lead upto 30m including back filling, watering and ramming of excavated earth into the structure and the sides of foundation trenches or into the plinth with removal and disposal of surplus earth as directed by E in C upto a distance of 30m from the foundation trenches. |
| 16 | Providing and laying Cement concrete (1:4:8) in base with cement , coarse sand , and 20mm to 40mm stone ballast including cost of all material, labour and T&P etc.complete. |
| 17 | Brick work in 1:4 cement mortar with cement , coarse sand , and M-150 bricks . including cost of all material, labour and T&P etc.complete. |
| 18 | Providing and laying RCC. (1:1.5:3) including cost of all material, labour and T&P etc.complete.(Excluding cost of Reinforcement) |
| 19 | Supplying of steel bars with bending,binding,cutting and placing of reinforcement including cost of wire including all material, labour and T&P etc.complete. |
| 20 | Painting top roofs with bitumen of approved quality @ 1.70 kg. Per Sq.M. impregnated with a cost of coarse sand @ 0.60 Cu.M. per 100 Sq. M. including cleaning the slab surface with a piece of cloth lately soaked in kerosene oil complete. |
| 21 | Centering and fine ply wood or steel shuttering for R C C Work including supply of all material Labour, T&P etc (Complete language for all heights.) |
| 22 | Providing and laying C.C. 1:2:4 with cement, Coarse sand and stone grit (10-20 mm size) including cost of all material, labour and T&P etc.complete. |
| 23 | Providing and laying I shaped precast interlocking tiles of thickness 80 mm (ordinary gray) i/c 25 mm thick local sand base levelling and dressing,filling joints with local sand etc. |
| 24 | Supply and hoisting of Sintex or equivalent high density polyethylene seamless of piece moulded tanks and placing the same in proper position including all taxes, labour and T&P etc. for proper completion of work. Tank should be ISI marked, Sintex or equivalent. |
| 25 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap. |
| 26 | Providing and fixing water closet squatting pan (Indian type W.C. Pan) with 100 mm sand cast iron P or S Trap, 10 litre low level white P.V.C. Flushing Cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : White Viterous China Orissa pattern W.C. pan of size 580x440 mm with internal type foot rests. |
| 27 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required:Single half stall urinal with 5 litre PVC. automatic flushing cistern |
| 28 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings 32 mm Flexible. |
| 29 | Providing & fixing Chlorinated Polyvinyl Chloride (CPVC) pipes(20 mm nominal outer dia pipes) having thermal stability for hot and cold water supply including all CPVC plain & brass threaded fittings, including fixing the pipes with clamps at 1.0 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per diection of Engineer in Charge. (For External work exposed on walls) |
| 30 | Providing & fixing Chlorinated Polyvinyl Chloride (CPVC) pipes(15 mm nominal outer dia pipes) having thermal stability for hot and cold water supply including all CPVC plain & brass threaded fittings, including fixing the pipes with clamps at 1.0 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per diection of Engineer in Charge. (For External work exposed on walls) |
| 31 | Providing and fixing C.P. brass Long body bib cock/ Angle Valve of approved quality conforming to IS:8931 15 mm nominal dia including cost of material, labour and T&P etc. |
| 32 | Providing and fixing 110 mm dia PVC pipe conforming to IS make working pressure 6 Kg/Cm including testing labour T&P and all complete fittings |
| 33 | Constructing brick masonry chamber (600x 600x750mm) for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design |
| 34 | Supplying and fixing 1.5 HP submersible pump incuding testing labour T&P and all complete fittings as per Direction of Engineer in Charge. |
| 35 | Supply & Fixing of Starter single phase MV. incuding testing labour T&P and all complete fittings as per Direction of Engineer in Charge. |
| 36 | Wiring point for light (Surface Conduit) in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit and GP Box ,Modular switch and ceiling rose/angle/ batten holder etc. complete in all respect, as directed . |
| 37 | Wiring point for fan /fresh air fan (Surface Conduit) (light duty exhaust fan) in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit ,GP Box, Modular type switch & ceiling rose etc, complete in all respect. |
| 38 | Wiring Point for plug (Surface Conduit) in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit , GP Box and Modular type switch and socket etc. complete in all respect. |
| 39 | Supply and fixing of power plug with 20 Amp./250 (Surface Conduit) volt flush type modular switch and 5 pin 20 A/250 volt flush type universal modular socket switch on concealed M.S box including supply of all material, labour T&P etc. required for proper completion of work |
| 40 | Supply and fixing of Electronic fan regulator( Modular) 120-280 V. ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work |
| 41 | Invertor Wiring in wiring Point for light/ Fan/ Plugwith 1.5 mm Cu Wire |
| 42 | S&F surface/flush mounting 8ways TPN distribution board with additional metal door without MCB complete in all respect, as directed by Engineer in charge. |
| 43 | S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve |
| 44 | S&F of 40 Amp. SPMCB (10KA)C Curve C |
| 45 | Supply and fixing hexagonal/Round G.P.fan box of approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S Bar X 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work |
| 46 | Submain in conduit on surface (2.5 sq. mm.)Supply and wiring of submain with two number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20mm dia. heavy duty (2mm thick) PVC conduit with 1 number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor as earth continuity wire. etc, complete in all respect. |
| 47 | Providing & fixing 1.2 meters high GI barbed wire fancing with 1.8 m angle iron post 40 mm x40 mm x 6 mm placed every m meters center to center founded in M15 grade cement concrete ,0.6 meter below ground level , every 15th post, last but one end post and corner post shall be strutted on boyh sides and end post on one side only and provide with 9 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckeles etc . complete as per clause 817 as per direction of Enginee-in-charge MoRTH Standard Data book .G.I Barbed Wire Fencing 1.8 Metre High |
| 48 | S/F Sign Board 0.0 0.0 Please Enable Macros to View BoQ information |