| 1 | Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out soft/loose soil complete all as specified and directed. |
| 2 | Excavating over areas n.exc 1.5 m deep and getting out soft/ disintegrated rock complete all as specified and directed. |
| 3 | Excavating over areas exc 1.5 m deep but n.exc 3.00 m deep and getting out soft/disintegrated rock complete all as specified and directed. |
| 4 | Excavating in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying cables, poles and stay etc n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 5 | Excavation in trenches n.exc 1.5 m wide and n.xc 1.5 m depth for foundation etc n.exc 10 sqm on plan and getting out in hard/dense soil complete all as specified and directed. |
| 6 | Returning, filling in, including spreading levelling watering and well ramming in layers n.exc 25cm as in hard/dense soil complete all as specified and directed. |
| 7 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed. |
| 8 | Removing excavated material to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.50 mtr above the starting point complete all as specified and directed. |
| 9 | Removing excavated material to a distance exc 1.5 KM but n.exc 5 KM and depositing where directed at a level n.exc 1.50 mtr above the starting point complete all as specified and directed. |
| 10 | Removing excavated material exc 250 m but n.exc 500 m and depositing where directed in hard/dense soil complete all as specified and directed. |
| 11 | Supply and lay unwashed Sand cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified. Note : Measurement shall be done after puning down of sand. |
| 12 | M&L cement concrete (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundation filling or sub base, Mass Concrete complete all as specified and directed. |
| 13 | M&L for cement concrete (1:2:4) type B-2 using 40mm graded crushed stone aggregte as in surface channels and drain complete all as specified and directed. |
| 14 | M&L for RCC nominal mix (1:2:4) using 20 mm graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like cpmplete all as specified and directed. |
| 15 | Precast RCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate in cover slabs of manholes, open drains inclusive of form work set in CM (1:4) complete all as specified and directed. Note :- Reinforcement shall be measured and paid separately. |
| 16 | M&L RCC M-25 (Design Mix) using 20 mm graded crushed stone aggregate as in foundation, raft, footing, plinth beam, base for column etc complete all as specified and directed. |
| 17 | M&L RCC M-25 (Design Mix) using 20 mm graded crushed stone aggregate as in column complete all as specified and directed. |
| 18 | M&L RCC M-25 (Design Mix) using 20 mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.50 m complete all as specified and directed. |
| 19 | M&L RCC M-25 using 20 mm graded stone aggregate as in slabs suppoorted on walls, beams and column in floors, roof, landings, balconies, canopies, deck slab and in shevels the like complete all as specified and directed. |
| 20 | Use and waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished concrete surfaces complete all as specified and directed. |
| 21 | Use and waste Formwork to sofits of suspended slabs such as roof slabs, floors slabs,landings and similar work n.exc 200mm thick (horizontal or sloping) for rough finished surfaces of concrete completed all as specified and directed. |
| 22 | Use and waste Formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished surfaces of concrete completed all as specified and directed. |
| 23 | Use and waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc and also splays between floors and beams, etc rough finished surfaces of concrete completed all as specified and directed. |
| 24 | S&F Mild TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 25 | S&F Mild TMT steel bars 8mm dia and over upto and including 10 mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 26 | M&L mild steel TMT bars 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or secring with clips complete all as specified and directed. |
| 27 | M&L old size brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed. |
| 28 | M&L for brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified. |
| 29 | M&L 10 mm thick Rendering on fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and directed. |
| 30 | M&L 15mm thick rendering on fair faces of brick surfaces in CM (1:4), first coat 10 mm thick plaster in CM 1:4 and second coat 5 mm thick in CM 1:4 with using water proofing liquid finished surfaces even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid seperately. |
| 31 | M&L for 5mm thick rendering in CM (1:3) on ceiling finished even and smooth without using extra cement complete all as specified and directed. |
| 32 | M&L for forming embarkment including raising (or lowering) earth spreading in layer n.exc 30 cm thick watering, ramming/rolling and finishing to required size and slope etc n.exc 1.5 mtr high from base complete all as specified and directed. |
| 33 | M&L Hard core gauge n.exc 63 mm of borken boulder below sub base/plinth protection/hard standing, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a truesurface complete all as specified and directed. |
| 34 | M&L for PCC 1:2:4 type B-2, 100 mm thick using 40 mm graded crushed stone aggregate as in floor finished the surface even and fair complete all as specified and directed. |
| 35 | M&L for PCC 1:4:8 type D2, 75mm thick using 40mm graded crushed stone aggregate as in sub base complete all as specified and directed. |
| 36 | M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including provision of 20 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 37 | M&L for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with all as per item No 37 including provision of 10 mm thick backing coat in CM 1:4 complete all as specified and directed. |
| 38 | M&L anti-termite Treatment of soil inder floors using emulsion @ one litre per litre per hole, 300mm apart including drilling and plugging 12 mm dia holes with CM 1:2 to match the floors complete all as specified and directed. |
| 39 | M&L for anti-termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear meter including drilling and plugging holes etc in apron complete all as specified and directed. |
| 40 | S&F factory made steel windows with side hung shutters including projecting type hinges with lugs steel handles and steel peg stays, with glazing bars, devetailed or welded complete all as specified and directed. |
| 41 | S&F factory made steel windows with side hung shutters including projecting type hinges with lugs steel handles and steel peg stays, without glazing bars, devetailed or welded complete all as specified and directed. |
| 42 | M&L framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290, Gde-E-165 complete all as specified and directed. |
| 43 | S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 44 | M&L Sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane 3 mm thick complete all as specified and directed. |
| 45 | M&L for rendering 10 mm thick on fair faces of concrete surface in cement mortar 1:3 for receive the roof finishes with water proofing liquid complete all as specified and directed. Note : WPL Shall be measured and paid separately. |
| 46 | Supplying and providing water proofing treatment over cleaned roof/chajja/vertical surface with 3mm thick polymeric standard water proofing APP membrane wt not less than 3 kg/m2 comprising of the following for Non approachable roof including cleaning, sweeping and washing with water to remove all dust etc from the plastered roof surfece or walls applying a coat of hot air blown bitumen of grade 82/25 confirming to IS 702 @ 1.20 kg/m2 over a coat of bitumen primer @ 0.3 kg /m2 on prepared surface weight of APP membrane not less than 3 kg/m2 with 100 mm over laps with sides and end . the over lap shall be sealed flame including with vertical surface after cutting necessary grooves and making good with PCC gala 1:2:4 type B1 etc adhere to hot blown bitumen all as per manufacturere instruction (i) over membrane applying a coat of hot applying bitumen of grade 85/25 confirming to ISD 702 @ 0.75 Kg/sqm binding Material such as dry condition minimum shall be dusted over bitumen including cement slurry 3Kg/Sqm, including two coat of aluminium paint complete all as specified and directed. |
| 47 | M&L for 75 mm thick cement concrete type C2, 1:3:6 using 40mm graded crushed stone aggregate finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 48 | S&F 125 x 60 mm size of Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and as directed. |
| 49 | M&L for plain cement concrete type C-0, 1:3:6 using 12.50 mm graded crushed stone aggregate for filling of hollow pressed steel frame complete all as specified and directed. |
| 50 | M&L for PCC (1:2:4), type B-0 using 12.5 mm graded crushed stone aggregate for fixing hold fast including repairing of disturbed plaster (while taking down door/window,ventilator frame) and matching the repaired surface with existing one complete all as specified and directed. |
| 51 | M&L for providing PCC (1:24) type B-1 using 20 mm graded crushed stone aggregate as in coping/channel of drain etc complete all as specified and directed. |
| 52 | S&F 25 x 3mm F1 hold fast conforming to Fe 290, Gde -E-165 complete all as specified and directed. |
| 53 | S&F 35mm thick second class hardwood factory made flush shutters, solid, core construction with black board core and plywood face panals commercial type on both sides complete all as specified and directed. |
| 54 | S&F 35 mm thick second class hardwood factory made glazed and skelton shutters open rebated and prepared to receive glass gauge etc without sash bars sizes of the members of the shutters as specified in SSR Part-I section 8, clause 8.24 (a) complete all as specified and directed. |
| 55 | S&F 150 mm extruded aluminium alloy handles, fabricated type, anodised and fixed complete all as specified and directed. |
| 56 | S&F 150 mm long aluminum anodized barred tower bolts of extruded section complete all as specified and directed. |
| 57 | S&F 300 mm Aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections and fixed complete all as specified and directed. |
| 58 | S&F Aluminium door stopper of size 150 mm long double legged fixed to bottom rail of door shutter provided with rubber bushing at one end to stop the door at floor and other end provided with aluminium plate base fixed with door shutter with screws at appropriate height complete all as specified and directed. |
| 59 | S&F MS 300mm helical door springs including roller and roller plate complete all as specified and directed. |
| 60 | Supply only liquid water proofing compound (ISI mark) complete all as specified and directed. |
| 61 | Preparing new surfaces of ceiling and applying three coat of white wash complete all as specified and directed. |
| 62 | M&L for preparation of newly plastered surfaces of wall and applying two coats distmper oil emulsion over a coat of primer and avg 3 mm thick wall care putty complete all as specified and directed. |
| 63 | M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including primingcoat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 64 | M&L preparing new steel surfaces and applying two coat of synthetic enameled paint over a red oxide primer exc 10 cm width or girth complete all as specified and directed. |
| 65 | M&L for Preparation of new or previously un treated wooden surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink priming complete all as specified and directed. |
| 66 | M&L for forming Contraction (Dummy) joints 100 mm deep x 10mm wide, filled with sealing compound Grade A complete all as specified and directed. |
| 67 | Finishing surface of concrete roads, pavements, by brooming complete all as specified and directed. |
| 68 | M&L for 150mm dia reinforced cement concrete pipe CL NP-2 laid and joionted complete with collars all as specified. |
| 69 | M&L PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 150 mm bore complete all as specified and directed. |
| 70 | S&F Cast iron centricast soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls, 75mm bore, confirming to IS-3989 complete all as specified and directed. |
| 71 | S&F 75 mm dia Cast iron cowls complete all as specified and directed. |
| 72 | M&L for point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC medium grade conduit not less then 20 mm width with MS sheet metal sunken switch/Terminal box 1.2 mm thick and ebonite switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface all as directed and specified. Note : (i) Making good to match with the adjoining surface shall be included in the unit rate. (ii) Rate is inclusive of cutting/chases of wall/floor/ceiling. |
| 73 | One 5 Amps light/fan/bell point controlled by one, one way switch. |
| 74 | One 3 pin 5 Amps socket out point on the same board with other switches. |
| 75 | One 3 pin 5 Amps socket out let point on independent board. |
| 76 | All as per Sr Item No. 72 here-in-before but with 4 Sqmm copper cable for power point. |
| 77 | M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 6.0 Sqmm, earth continuity conductor of size 6.0 Sqmm to be drawn through and including PVC conduit 25 mm dia medium grade conceled in walls/roof/floors complete all as specified and directed. Note :- Two wires of 6.0 Sqmm and one wire of 4.0 Sqmm and one run of PVC conduit shall be measured as one unit. |
| 78 | S&F Switch piano flush type single pole one way 6 Amps. |
| 79 | S&F Socket out let 2 in one, 5/3 pin 6 Amps. |
| 80 | S&F Switch socket 2 in 1, 5 & 15 Amps flush type |
| 81 | S&F Ceiling rose, surface bakelite 65 x 50 mm three terminal. |
| 82 | S&F LED lights fitting 1 x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 83 | S&F Electronic regulator 100/120 Watt step type complete all as specified and directed. |
| 84 | S&F ceiling fans with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 85 | S&F Single pole and neutral 8 way double door sheet metal enclosure factory made DBs protection class IP-42, suitable for fixing of MCBs confirming to IS-13032, Isolators etc with 200 Amps rated bus bar 240V powder coated painted complete all as specified and directed. |
| 86 | S&F MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 40 Amps complete all as specified and directed. |
| 87 | S&F MCB SPN 20 Amps 240 Volts complete all as specified and directed. |
| 88 | S&F LED street light fitting 40 Watt, 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified and directed. |
| 89 | S&F Exhaust fan, steel body AC Single Phase 230V of size 300mm sweep with blades and frame and louvers complete all as specified and directed. |
| 90 | S&F GI Steel water tubing light grade IS marked including all fittings laid in trenches complete all as specified and directed. |
| 91 | S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 2 core complete all as specified and directed. |
| 92 | S&F un-reinforced, precast concrete cable cover of LV, Type I, flat, size 250 mm x 150mm x 40mm complete all as specified and directed. |
| 93 | Schedule of credit amount of Rs 00.0 to be deducted during AOC. Please Enable Macros to View BoQ information |