|
| 1 | BoQ BOQ Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GARRISON ENGINEER TEZPUR (NORTH) NAME OF WORK : REPAIR/REPLACEMENT OF PERIMETER LIGHTS, GARDEN LIGHTS, EARTHING AND LIGHTNING PROTECTION WITH ALLIED WORKS AT AGE CHARDUAR AREA UNDER GE (N) TEZPUR. Contract No : GE(N)/TEZ/ OF 2026-2027 (File No. 8272/E8) Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Description of items of works Item Code / Make Approx No. of quentity required. Units Pre Priced Rate (in. Rs.) as Defined by MES Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures to be entered by the Bidder Rs. P. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT (In INR) TOTAL AMOUNT With Taxes TOTAL AMOUNT (In Words) |
| 2 | Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft / loose soil complete all as specified and as directed. |
| 3 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified and as directed. |
| 4 | Removing excavated material / soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 5 | Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and directed. |
| 6 | Supply and laying well burnt bricks sub class 'B' in trenches for cable protection of U/G cable complete all as specified and directed. |
| 7 | Taking down the existing damage / unservicable LT under ground cable/ACSR OH conductor any description of any size from trenchs /walls/poles/floors etc and depositing where directed at site.Note :- Excavation and earth work will be measured under replacement items |
| 8 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 10 sqmm 4 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ. |
| 9 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 16 sqmm 4 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ. |
| 10 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 25 sqmm 4 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ. |
| 11 | S & L trenches /fixed on walls by suitable clamps and jointing complete GI pipe 50 mm dia light grade of following sizes complete including taking down and all as specified and directed by Engr-in Charge . |
| 12 | M&L for 40 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and directed. |
| 13 | M&L for 25 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and directed. |
| 14 | S&F MCB distribution board made of CRCA sheet, powder coated paint comforming of IS 13032, single door fixed in switch boards/wall at various places of capacity 240volt, 2 way MCB DB, SPN, IP 38 protection including taking down of old unserviceable existing DB complete all as specifided and directed |
| 15 | S&F MCB, Single pole 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA including taking down old unserviceable existing MCB complete all as specified and directed. |
| 16 | S&F street light Junction box PVC with operation suitable for accommodating and including heavy duty PVC connector block of 30 amps capacity three phase with one number single pole MCB 06 Amps complete including fixing to pole with suitable brackets, bolts/nuts in connecting cable in testing including taking down old unserviceable existing Junction box complete all as specified and directed. |
| 17 | Taking down the existing mounted LED security lights of gate lights/flood ights / ground lights of any size etc in carrying out repairs including checking luminous replacement of defective spares parts and checking all connection to make the fitting serviceable including replacement of connection while from junction box to fittings and rectifying the same after attending repairs complete all as specified and directed.Note: The spare parts required for making the lights will be measure and paid relevenat item only |
| 18 | Supply only LED Drived 25 watts suitable for existing LED light site requirement comnplete all as specified and directed |
| 19 | Supply only LED Drived 45/60 watt suitable for existing LED light site requirement comnplete all as specified and directed |
| 20 | Supply only 1.5 sqmm 3 core copper codector multsand cable comnplete all as specified and directed |
| 21 | Supply only 15 mm PVC pipe with suitable clamp and nuts/bolts comnplete all as specified and directed |
| 22 | S & F LED street/Security light fitting 25 Watt 230 V AC outdoor type new generation energy saving environmental friendly long life versalile pressuree die cast aluminum hosing and heat resistant complete with driver, including thermal management in multiple optics complete with IP 66 protection including connecting up with and including three core twisted flexible copper conductor cable with suitable size including taking down of old unserviceable existing light fittings including taking down of old unserviceable existing light fittings complete all as specified and directed. |
| 23 | S & F LED Building Security light fitting 45 Watt 230 V AC outdoor type new generation energy saving environmental friendly long life versalile pressuree die cast aluminum hosing and heat resistant complete with driver, including thermal management in multiple optics complete with IP 66 protection including connecting up with and including three core twisted flexible copper conductor cable with suitable size including taking down of old unserviceable existing light fittings complete all as specified and directed. |
| 24 | S & F LED Building Security light fitting 60 Watt 230 V AC outdoor type new generation energy saving environmental friendly long life versalile pressuree die cast aluminum hosing and heat resistant complete with driver, including thermal management in multiple optics complete with IP 66 protection including connecting up with and including three core twisted flexible copper conductor cable with suitable size including taking down of old unserviceable existing light fittings complete all as specified and directed. |
| 25 | S & F energy saving & environment friendly long life 120 W, outdoor type, LED Flood light made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection & impact resistance not less than IK-10 complete with integrated type, with high efficiency electronic driver, built-in surge suppressor / SPD of 10 KV or more & high brightness LEDs, luminaire efficacy > 120 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz complete including bracket suitable fixing arrangement including taking down of old unserviceable existing light fittings complete all as specified & as directed |
| 26 | S&F for new generation energy saving garden light 10 W environmental friendly long life aesthetically desiged aluminium landscape luminire for diffused lighting with high power LED as light source complete as per category: Havells \\"TURIN LED BOLLARD\\" or similar specification including taking down of old unserviceable existing light fittings complete all as specified & as directed |
| 27 | Supply, fix, test and commissioning LED Post top latern luminaries outdoor type 60 Watts new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LEDs as light source and electronic driver suitable for operation on AC single phase 220-240 Volts, 50 HZ supply, including provision of two single core 1.5 sqmm copper conductor PVC insulated, 1100 Volts, cable not less than 8 meter long etc, connectiing from junction boxes of poles including taking down of old unserviceable existing light fittings complete all as specified & as directed |
| 28 | Supply, fix, test and commissioning LED Post top latern luminaries outdoor type 20 Watts new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LEDs as light source and electronic driver suitable for operation on AC single phase 220-240 Volts, 50 HZ supply, including provision of two single core 1.5 sqmm copper conductor PVC insulated, 1100 Volts, cable not less than 8 meter long etc, connectiing from junction boxes of poles complete all as directed by Engr-in-Charge. |
| 29 | Supply and fix for bracket for single street light fitting with GI pipe medium grade 40 mm dia 2 m long bend to shape and double clamped with fabricated MS clamps as directed and fixed out side wall with bolts and nuts including taking down of old unserviceable existing fittings complete all as specified & as directed |
| 30 | S & F energy saving & environment friendly long life 70 W, outdoor type, LED Flood light made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection & impact resistance not less than IK-10 complete with integrated type, with high efficiency electronic driver, built-in surge suppressor / SPD of 10 KV or more & high brightness LEDs, luminaire efficacy > 120 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz complete including bracket suitable fixing arrangement including taking down of old unserviceable existing light fittings complete all as specified & as directed |
| 31 | S & F energy saving & environment friendly long life 50 W, outdoor type, LED Flood light made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection & impact resistance not less than IK-10 complete with integrated type, with high efficiency electronic driver, built-in surge suppressor / SPD of 10 KV or more & high brightness LEDs, luminaire efficacy > 120 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz complete including bracket suitable fixing arrangement including taking down of old unserviceable existing light fittings complete all as specified & as directed |
| 32 | Supply & Lay of PVC insulated flat aluminium conductor cable of 10 Sqmm x 2C Coplete with all suitable accessories as directed by Eng-in-Charge including taking down of old unserviceable existing light fittings including taking down of old unserviceable existing complete all as specified & as directed |
| 33 | Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6.3 mm thick burried directly in ground( earth pit not less than 2.25 m deep below the normal groungnd level) with top edgee of the plate not less than 1.5m below normal GL connected to GI earth strip of size 25x4mm by means of bolts, nuts, check nuts washers of GI or steel all as shown in electrical plate No-5 of SSR Part I connected to machanery/equipments installed power house/sub station/building all as specified including testing on completion.Note No-1 the unit rate shall also include for excavation earth work in any type of soil PCC (1:3:6) type C1 pit RCC 1:2:4 type B-1 cover reinforced with 8 mm dia CTD bars @ 150mm C/C both ways funnel with 15mm bore GI watering pipe 20mm dia bore GI protection pipe wire mesh and copper lugs complete in addition to item No 1(a) to (e) of preamble ( Notes) Under sub heading earthing specified on SI page NO-389 of SSR Part-II 2004. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |