| 1 | PROVN OF COVERED PASSAGE CONNECTING MI ROOM TO TRISHAKTI AT DSSC WELLINGTON. |
| 2 | Excavation in post holes (or similar holes) each n exc 0.5cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers n exc 25cm ,in watering and removing surplus soil to a distance n exe 50m and making good surface in hard/dense soil all as specified and as directed. |
| 3 | M&L for Cement concrete type C-2 (1:3:6) using 40mm graded stone aggregate as in foundations,filling and mass concrete complete all as specified and as directed. |
| 4 | M&L Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240conforming to Fe-410-W(Gde-E-250) quality B complete all as specified and as directed. |
| 5 | M&L for Rolled sections as in main and cross beams, hip and jack rafters;purlins where connected to common rafters and running rails and guides for sliding doors;fixed with angle cleats or other connecting plates conforming to Fe-410-W(Gde-E-250) quality B complete all as specified and as directed. |
| 6 | S&F poly carbonate sheet of approved colour 4 mm thick solid sheet half round of appropriate size including necessary drilling etc. fixed with self tapping screws complete all as specified and as directed. |
| 7 | S&F PVC(SWR) 150 mm dia half round Rain water gutter incl all joints etc complete all as specified and as directed. |
| 8 | S&F PVC(SWR) bends any radius 110mm bore provided with access door complete all as specified and as directed. |
| 9 | S&F Aluminium wind tie (flat) with 50 mmx 6mm thick including necessary cutting, drilling and fabrication etc including fixed with self tapping screws on new or old CGI/Polycarbonate roofing etc. complete all as specified and as directed. |
| 10 | Material and labour for two coat SE paint on steel surface over one coat of red oxide primer incl prepareation of new or old steel surface complete all as specified and as directed. |
| 11 | Surface excavation n exc 30cm deep and averaging 15 cm deep and getting out in hard/dense soil completecomplete all as specified and as directed. |
| 12 | M&L hardcore of gauge n.exc 63 mm deposited, spread & levelled in layers n. exc 15 cm thick, watered & rammed to a true surface with broken stone or boulders complete all as specified and as directed. |
| 13 | M&L 75mm thick PCC 1:3:6 type C2 (40 mm graded aggregate) as in Sub base floor finished even and fair to receive top layer of floor etc complete all as specified and as directed. |
| 14 | M&L heavy duty vitrified unporcelain floor tiles of size 300x300 mm , 10 mm thick suitable for heavy vehicles movement, laid in floors/skirting of pattern as approved set and jointed with Epoxy grout with spacers to match over 20 mm thick cement mortar (1:6) all as specified and as directed.make Neo Deccan Natural of Somany , Endura of Johnson, Orient Bell or equivalent. |
| 15 | M&L for PCC 1:3:6 type C1 using 20mm graded stone aggregate steps, seismic and other similar bands, plinth courses string courses, lacingcourses,parapets and railing upto 60cm in height, copings, kneelers, apex stones,bed plates, kerbs , water troughs and the like including weathering, slighty rounded or chamfered angles and throating, complete all as specified and as directed. |
| 16 | Removing excavated materialnot exc 1.50 km but n exc 5 km depositing where directed (Soils) at a level not exc.1.5mts above the starting point complete all as specified and as directed. |
| 17 | PROVN OF SHED FOR BACKUP INVERTOR SUPPLY, FALSE CEILING, AWNING AND CONNECTED ALLIED WORKS IN WATERMANSHIP TRAINING CENTRE (WTC) AT DSSC WELLINGTON |
| 18 | Demolition Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 19 | Demolition cement Concrete(unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 20 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 21 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 22 | Taking down chowkats or frames exc 1.5 but n.exc 4 Sqm each with shutters(without taking off shutters from the frames) complete all as specified and as directed. |
| 23 | Excavating in trenches, exc 1.5 m wide and n exc 3 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and exc 1.5 m but n.exc 3m in depth and getting out in soft soil complete all as specified and directed. |
| 24 | M&L for Cement concrete type D-2 1:4:8 using 40mm graded aggregate in foundations, filling and mass concrete complete all as specified |
| 25 | M&L Pre-cast cement concrete block masonry with solid blocks type C-1, 1:3:6 (using 20mm graded aggregate) , exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed. |
| 26 | M&L for rendering 10mm thick on brick/concrete surface in CM 1:6 to wall finished even and smooth without using extra cement complete all as specified and directed. |
| 27 | M&L for 15 mm thick rendering in cement mortar 1:4 on brick work/concrete surfaces of wall, finished even and smooth with out using extra cement and mixed with Water Proofing compound including scaffolding complete all as specified and as directed.Note: WPC shall be measured and paid seperatly. |
| 28 | Supply only integral water proofing compound complete all as specified and as directed. |
| 29 | M&L for two coats of oil bound distemper on cement plaster over a coat of primer after preparation of surface on wall complete all as specified and directed. |
| 30 | M&L for painting to cement plaster surfaces with two coats of cement base paint over a coat of alkali resistant primer after preparation of surface complete all as specified and as directed. |
| 31 | M&L for hardcore of broken stone or boulder gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 32 | M&L for 150mm thick Cement concrete 1:4:8 type D- 2, (40mm graded aggregate in floor complete all as specified and directed. |
| 33 | M&L for 100mm thick Cement concrete type B-2, 1:2:4 (40mm graded aggregate) as in floor finished even and smooth without using extra cement complete all as specified. |
| 34 | M&L providing cement concrete 1:2:4 type B-1 (Using 20mm graded stone agg) , 25mm thick as in sub base in floor/paving etc complete all as specified and as directed. |
| 35 | M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick (square) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding of cm 1:6 layer in floor finishes complete all as specified and as directed. |
| 36 | M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick (square) area of each tile exceeding 0.16 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding of cm 1:6 layer in floor finishes complete all as specified and as directed. |
| 37 | S & F 2nd class hardwood, Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed in position complete all as specified and as directed. |
| 38 | M&L hold fasts size 25 x 3 mm; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed. |
| 39 | S&F 35 mm thick 2nd class hardwood, Plain, framed, panelled Factory made shutters (two panels), with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS 1003 (Part-I) klin seasoned and chemically pressure treated complete all as specified and as directed. |
| 40 | S&F 35 mm thick 2nd class hard wood glazed and skeleton shutter of factory made divided into square, with plain chamfered or rounded mitred and rebated sash bar any number with edges of sash bar & framing moulded all as specified as per IS fitted to chowkats complete all as specified and as directed. |
| 41 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 42 | S&F butt 100mm size, hinges medium weight, cold rolled mild steel, etc complete all as specified and directed. |
| 43 | S & F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed. |
| 44 | S& F aluminium anodised tower bolt of extruded section, 150mm long, etc complete all as specified and directed. |
| 45 | S&F aluminium handle extruded aluminium alloy fabricated type, 150mm size etccomplete all as specified and directed. |
| 46 | S&F floor door stopper of aluminium alloy body and tounge, anodised with hard drawn spring fixed in floor, overall length of cover plate 150 mm complete all as specified and as directed. |
| 47 | Taking down steel tubing and connections, including cleaning for refixing or removal to store of 15 mm bore complete. |
| 48 | S&F mild steel galvanised tubes 15mm medium grade with all fitting, fixed to wall, ceiling or laying in floor.etc complete all as spd and directed. |
| 49 | S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 20mm bore complete all as specified and directed. |
| 50 | PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 51 | S&F 110 mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, jointed with solvent laid in trenches or in floors complete all as specified and directed. |
| 52 | S&F for 110mm bore PVC (SWR) bends any radius complete all as specified and directed |
| 53 | M&L for Joist, channel, angle, or tee sections, Fe-290 (Gde-E-165), fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and as directed. |
| 54 | M&L for rolled mild steel in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe-290 (Gde-E-165) complete all as specified and as directed. |
| 55 | M&L preparation of new steel surface of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specifed and as directed. |
| 56 | M&L for preparation of old painted steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying one coat of synthetic enamel paint (ordinary tint) complete all as specified and as directed. |
| 57 | S&F 6mm thick plain, multicavity poly carbonate sheet (transparent ) in roof covering, fixed with and including aluminium fillets at joints and aluminium angles at the end, fixed with self drilled screws and standard fittings, fixtures and accessories complete all as specified and as directed. |
| 58 | M&L for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 59 | M&L for cement concrete type B-0 1:2:4 using 12.50mm graded aggregate, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 60 | S&F false ceiling of Non asbestos fibre cement building boards, manufactured from homogeneous mixture of cement, quartz and cellulose and cured with high pressure steam using auto claving process confirming to IS-14862, of size 600 mm x 600 mm x 4 mm thick fixed over and including anodised aluminium powder coated (minimum thickness of powder coating 50 micron) snap grid frame work of T section (main & cross member) of size 25 mm x 25 mm x IS mm thick in square pattern of grid size 600mm X 600mm . The aluminium frame work will supported on side wall with the used of aluminium 'L' section of size 25 mm x 25 mm x 1.5 angles etc. Snap grid shall be supported with hangers of 4 mm dia. Galvanised iron wire adjusting level fixed to roof slabs / truss etc by means of ceiling cleats made out of Galvanised iron flat of size 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified directed. |
| 61 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft soil complete all as specified and directed. |
| 62 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in soils |
| 63 | M&L for finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) after complete removal of existing treatment and providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth on wall complete all as specified and directed. |
| 64 | S&F Two track sliding frame (60mm x 62mm) for Providing and fixing factory made uPVC white colour casement/sliding window/door, made of extruded profiles. Profiles of frames and sash will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc.. making arrangement for fixing of hardware, EPDM gasket, 1.2+ 0.2.mm thick galvanized steel profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, all complete and as directed, (Glazing, hardware hinges and fitting, EPDM rubber gasket etc. to be paid separately.) Note:-Each member of window to be measured separately wrth clear length. |
| 65 | S&F Providing and fixing factory made uPVC white colour fixed window made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (Onevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners- 5mm thick glazing with selected quality glass(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories Net opening will be measured for payment purpose.)(A) Area not exceeding 1.00 sqm each |
| 66 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.. complete all as specified and directed. |
| 67 | Taking down old sub-main wiring incl fixture & fittings etc. removing materials to store for keeping in safe custody or for taking credit & making good the disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 68 | M & L for concealed point wiring with two single core 1.5 sqmm PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with multi stranded copper conductor drawn through and including non-metallic PVC rigid conduit (medium grade) with all fittings and accessories ISI marked incl provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLS, ISI marked as earth continuity conductor (green in colour) & incl fixing of modular metal flush boxes of appropriate size & thickness fixed flush to wall for mounting switch, sockets etc. with including cutting chases for conduits & sinkings for modular boxes & making good the disturbed surfaces, matching to the existing one etc. complete all as specified & as directed. (a) One light point or one fan point controlled by one switch |
| 69 | b) One 3 pin socket outlet, 5 amps, independent |
| 70 | All as per Item No-66 above but One 3 pin socket outlet. 15 amps, independent,with cables 4 sq. mm size complete all as specified and directed. Please Enable Macros to View BoQ information |
| 71 | All as per Item No-66 above but One 3 pin socket outlet. 15 amps, independent,with cables 4 sq. mm size complete all as specified and directed. Please Enable Macros to View BoQ information |