| 1 | Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth and getting out in soft/loose or any other type of soil for taking up or laying of cable all as specified and directed. |
| 2 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms. |
| 3 | Removing excavated material not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above starting point. |
| 4 | Supply and laying new dry river sand laid in trenches 8cm below the cable and 15cm above the cable and punned to 18cm as cable cushioning and covering all as directed. |
| 5 | M&L for laying bricks, sub class'B' for protection of cable, in trenches, laid in dry flat across the cable with length of whole bricks complete all as specified and directed. |
| 6 | Taking down/erecting in replacement steel tubular poles in vertical position/as strut poles sewaged 410-SP-31, 9 Mtr long, complete all as specified and as directed at site by the Engr-in-Charge. |
| 7 | Supply and fix Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0metres long) complete all as specified and as directed |
| 8 | S & F in replacement pin type insulator procelain, vitreous white, brown or green including galvanised mild steel spindle, two nos galvanised iron washer and one galvanised iron nut 100mm height, 65mm dia for 1100 volts grade complete including taking up of old UNSV pin type insulator complete all as specified and directed by Engr-in-Charge. |
| 9 | S & F in replacement shackle type insulator porcelain vitereous white, brown or green including galvanised M.S. straps 31x5mm size, 100mm height, 115mm dia including galvanised mild steel straps, nut, bolts washers complete for 1100 volts grade insulator complete including taking up of old UNSV Shakle type complete all as specified and directed by Engr-in-Charge. |
| 10 | M & L in repacement of cross arms, bracings, supports, clamps, back plate fabricated from structural steel sections such as channels, angles, flat iron including 16mm dia bolts, nuts, washers, welding, bending, cold or hot drilling holes for bolts/insulators in any shape and size as directed and inclusive of one priming coat of red oxide zinc chrome, one under coat and one finishing coat of aluminium paint including dismantling of old unserviceable cross arms complete including taking up of old UNSV cross arms complete all as specified and directed by Engr-in-Charge. |
| 11 | Supply and fixing in replacement of ACSR conductor for LT/HT OH Line aluminium conductor steel reinforced size as per existing including dismantling of old unserviceable ACSR conductor including taking up of old UNSV ACSR conductor complete all as specified and directed by Engr-in-Charge. |
| 12 | M & L cupper wire with Two core 2.5 sqmm PVC insulated 1100 volts grade connected from DB to DB/main board complete all as specified and as directed. |
| 13 | M&L for painting of steel tublar pole 9 Mtr long, LT any type vertical complete with cross arms with one coat of aluminium paint after preparation on of surfaces of pole/cross arms including painting of red strip of 30cm upto 1.5Mtr above coping along with fluorescent/light reflecting tape of yellow colour and directed by Engr-in-charge. |
| 14 | M&L in replacement for Earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick burried in a pit to a depth of 2.25mtrs below ground level with top edge of earth plate at a depth of not less than 1.50 meters below ground level, earth plate packed on all sides with charcol dust mixed with salt to a thickness of 15cm,.Connected with earthing lead of 32mmx6mm strip galvanised iron, watering pipe 20mm dia light grade and water filling funnel and mess complete all as shown in plate No 3 of MES schedule part II to the earthing test point, Including PCC Work complete including taking up of old UNSV earthing complete all as specified and directed by Engr-in-Charge. (Note :- Earthing lead beyond test point shall be measured separately) |
| 15 | Supply and laying in replacement of earthing strip GI 32 x 6 mm from earth test point to Electrical equipment including taking up of old UNSV earthing strip complete all as specified and directed by Engr-in-Charge. |
| 16 | Taking down of old U/S cable of any size any capacity of broken/damage all specified & directed by Engr-in-charge. |
| 17 | Supply Laying, jointing, testing and commissioning or fixing in replacement of cable in wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor, 1100 volts, grade of cross sectional area as under including taking up of old UNSV XLPE cable complete all as specified and directed by Engr-in-Charge. :- (a) 16 sqmm 4.0 core |
| 18 | (b) 25 sqmm 3.5 core |
| 19 | (c) 35 sqmm 3.5 core |
| 20 | (d) 50 sqmm 3.5 core |
| 21 | (e) 70 sqmm 3.5 core |
| 22 | (e) 95 sqmm 3.5 core |
| 23 | (g) 120 sqmm 3.5 core |
| 24 | (g) 150 sqmm 3.5 core |
| 25 | (h) 10 sqmm 4.0 core |
| 26 | (i) 10 sqmm 2 core |
| 27 | (k) 6 sqmm 2 core |
| 28 | S & F in replacement of GI tubing light grade 50mm nominal bore for cable protection fixed with clamps of M.S. Flat iron 25x3mm, GI nuts, bolts and washers to poles/under floor/under roads/alongwith walls including two coats of aluminium paint over a coat of red oxide primer on clamps complete including taking up of old UNSV GI tubing complete all as specified and directed by Engr-in-Charge. |
| 29 | S&F 25 mm bore dia light grade GI steel tubing with all fittings for fixing of tapping of incoming and outgoing point complete all as specified and directed. |
| 30 | S&F 32 mm bore dia light grade GI steel tubing with all fittings for fixing of tapping of incoming and outgoing point complete all as specified and directed. |
| 31 | S&F 40 mm bore dia light grade GI steel tubing with all fittings for fixing of tapping of incoming and outgoing point complete all as specified and directed. |
| 32 | M&L PCC 1:3:6 type C1using 20mm stone aggregate for coping of pole complete all as directed |
| 33 | M&L PCC 1:3:6 type C2 using 40mm stone aggregate for stay assembly complete all as directed |
| 34 | M&L PCC 1:4:8 type D2 using 40mm stone aggregate for pole foundation complete all as directed |
| 35 | Taking down Supply and fix in replacement of old unserviceable LED street light fitting 90 Watt230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistantcomplete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete withIP 65/66 protection complete |
| 36 | Taking down Supply and fixing LED flood light 200 watt 230 VAC outdoor type with thermal management inmultiple optics and equipped with IP66protection, with impact and corrosion resistantcomplete with driver and lamp complete all as specified. |
| 37 | Taking down Supply and fixing LED flood light 100 watt 230 VAC outdoor type with thermal management inmultiple optics and equipped with IP66protection, with impact and corrosion resistantcomplete with driver and lamp complete all as specified. |
| 38 | Taking down Supply and fix in replacement of unserviceableSupply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistantcomplete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete withIP 65/66 protection complete |
| 39 | Supply and fix in replacement of unserviceable Supply and fixing LED street light fitting 45 Watt230 V AC outdoor type with senser high pressure diecast aluminum hosing and heat resistantcomplete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete withIP 65/66 protection complete. |
| 40 | Supply and fix in replacement GI pipe 25 mm 1.5 Mtr ling dia of suitable size min 0.60 mtr length fixed on wall with bracket, clamps, nuts and bolts complete as directed by engr-in-charge. |
| 41 | Supply & Fixing in replacement of MCCB, 4 Pole, 100 Amps, 415 Volt, 36 kA including connecting up using suitable size of lugs all as directed. |
| 42 | Supply & Fixing in replacement of MCCB, 4 Pole, 160 Amps, 415 Volt, 36 kA including connecting up using suitable size of lugs all as directed. |
| 43 | Supply & Fixing in replacement of MCCB, 4 Pole, 200 Amps, 415 Volt, 36 kA including connecting up using suitable size of lugs all as directed. |
| 44 | Supply & Fixing in replacement of MCCB, 4 Pole, 250 Amps, 415 Volt, 36kA including connecting up using suitable size of lugs all as directed. |
| 45 | Supply & Fixing in replacement of MCCB, 4 Pole, 400 Amps, 415 Volt, 36 kA including connecting up using suitable size of lugs all as directed. |
| 46 | Supply & Fixing in replacement of MCCB, 4 Pole, 350 Amps, 415 Volt, 36 kA including connecting up using suitable size of lugs all as directed. |
| 47 | Supply & Fixing in replacement of MCCB, 4 Pole, 630 Amps, 415 Volt, 50 kA including connecting up using suitable size of lugs all as directed. |
| 48 | Trimming of trees all as along the LT line in such a way that there is clear distance of 3 meter between tree and electric line. The work will be executed to the entire satisfaction of Engr-In-Charge irrespective of the size of the tree branches etc complete all as specified and as directed. Note : (i) Tree branches etc will be left as itias the wood belongs to Cantt board/DEO back as if the property of (ii) Contractor will employ sufficient labour to complete the full one job with in time consitant by directed by engr-in-charge.(iii) Contractor will only be responsible for any type of accident if take place while trimming the trees. (iv) Contractor supervisor will take proper shut down from MES installation before starting the work and clear it before resuming power supply, however full asministrativeassistance will be provided by MES staff. |
| 49 | M & L in replacement for stay assembly complete for LT over head line comprising of 7/4.00mm (7/8 SWG) galvanised M S Stranded wire of required length fixed to poles with and including flat iron, clamps, fabricated out of 50x6mm flat iron, bolts, nuts and washers, GI stay bow 19mm dia 400mm long with threading ends, GI nuts and wahsers, M S stay plate galvanised 305x305x6mm thick,stay rod 20mm dia, two numbers thimbles including taking out old unserviceable stay assembly complete all as specified and as directed by the Engr-in-Charge.Note : Earth work and PCC measured and paid at approprite item. |
| 50 | M&L in replacement of DB for street light made out of CRC sheet, dust and vermin proof out door type duly painted of size 200 mm x 200 mm x 15 mm with arrangement of incoming and outgoing feeder with bus bar of suitable capacity for termination of line with single MCB SP, 230 V, 6-10 Amp 10 KA ( In accordance wth IS/IEC 60898-1) and arrangement for fixing cooper wire of size 2 x 1.5 Sqmm with 1 x 1.0 Sqmm earth wire in green color of FR PVC insulated copper conductor,from DB to light fitting complete including taking up of old UNSV DB complete all as specified and directed by Engr-in-Charge. |
| 51 | M & L required for retrenching / tightening of LT over head line (Conductor) of any type/GI earth wire including opening out binding wire from pin/shackle/disc insulator and rebinding the conductor with insulator with 14 SWG binding wire complete all as directed by Engr-in-Charge. |
| 52 | Supply and fix in replacement of Voltmeter 0 - 230 Volts, Digital display, flush mounted 96mm square 3 phase 4 wire with slector switch complete all as specified and as directed. |
| 53 | Supply and fix in replacement of Ammeter 0 - 500 Amps, Digital display, flush mounted 96mm square 3 phase 4 wire with slector switch complete all as specified and as directed. |
| 54 | Supply and fix in replacement of LED based indicator lamp sets comprising of three colours complete all as specified and as directed. |
| 55 | M & L for painting of existing panel with the same existing colour and repair and replacement of the doors of the existing panel complete all as specified and directed. |
| 56 | S&F in replacement of synthatic rubbe insulated mats 2.5 mm thick for electrical purpose as per ISI marked suitable for electrical shock of size 2x1 mtr complete all specified & directed by Engr-in-charge. |
| 57 | S&F Danger notice plate of sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 25x20cm all as specified and directed by Engr- in -charge. |
| 58 | M&L for highmask light of this area checking of serviceable of the light connection of and painting ,replacement of flood light complete all as specified and directed by Engr-in-charge. |
| 59 | S&Fix in replacement of 10sqmm 2 core aluminium of service wire sithed of covered complete all as specified and directed by Engr-in-charge. |
| 60 | M&L for jointing and testing of straight through termination joint (heat shrinkable) suitable for 3.5 core (Earthed) underground XLPE cable of size 10 to 50 sq mm including taking down existing unserviceable joint complete all as specified and as directed. |
| 61 | M&L for jointing and testing of straight through termination joint (heat shrinkable) suitable for 3.5 core (Earthed) underground XLPE cable of size 50 to 95 sq mm including taking down existing unserviceable joint complete all as specified and as directed. |
| 62 | M & L for Boring under Road / PCC by using manual tool for inserting, including GI pipe of 80mm size for protection of cable complete all as specified and as directed by the Engineer-In-Charge. |
| 63 | M & L for Cutting of existing RCC Floor/PCC/Tiles for electrical cable and supply and fix tube, 'light grade, galvanised 25mm dia, necessary connection to TPN DB from LT control panel and making good to the disturbed surfaces of floor from RCC including to match the existing type etc all as directed |
| 64 | Attending the complaint of Electric supply of any type such as ,no electric supply in Accn or breakdown of electric & rectifying the complaint within the timeline of electricion with helper,veh stair etc with safty tools, and other refixing material will be included in the provided contractor quote rate.Complaint to be recd at 24 hrs daily complaint in three shifts attending register to complaint silip ,telephonic msg of encharge and rectifying the issue and same as deposited complaint silip to JE(E/M) encharge of Electric supply. |
| 65 | Supply and fix in replacement of three phase LT spacer for over head lines complete all specified and directed by Engr-in-charge. |
| 66 | Supply and fixing, testing and commissioning Out door type Bus bar made out of MS CRCA sheet 2mm thick of size 0.60 Mtrx0.60mtrx0.30 mtr consisting of aluminium Bus Bar of rating 400 Amps with incomming & oytgoing MCCB 200A working 4 wire system 415 volt mounted on various insulator with cable earth alleys including steel flexible pipe as per required length at site with new aluminium lugs of suitable size including making connection properly of existing cables of any size/type for existing new incoming and outgoing cables complete all as specified and as directed by Engr-In-Charge. Note : Bus Bar mounting stand made out of angle iron of size 50mm x50mm x 6mm, 600 mm high and size suitable to mount the panel including foundation of PCC (1:3:6) type C-1 using 20mm graded stone aggregate with and including excavation and earth work in any type of soil complete all as specified and directed. |
| 67 | Supply, installation, testing and commissioning in replacement electrical cubical control out door cubical fedder pillarbox factory assembled wheather and vermin proof fabricated of 3.15 mm CRCA MS sheet Suitable for ,3 phase 4 wire 415 Volt AC 50 Hz complete electric supply duly painted with powder coating complete with locking arrangement, earthing terminals with suitable incoming/outgoing MCCB's, measuring instrument such as digital Volt meter,digital Ammeter, Selector switchs, with suitable ratio CT's - 3 Nos , Phase indicator lamps with holder , toggle switches and backelite fuse cut outs etc including incoming and outgoing cables connections with suitable cable glands and grouting of feeder pillar box 30 cm above and 30 cm below ground level by providing angle iron size 50x50x6mm welded on all four corner embedded in PCC (1:2:4) using 20mm graded upto 30cm complete including taking up of old UNSV feeder pilarbox complete all as specified and directed by Engr-in-Charge.( Feeder piller box shall be consisting the following in addition to the item mentioned here -in- before) |
| 68 | (a) Aluminium bus bar proper insulated 03 Nos for phase (RYB) rating 400 Amp and 01 Nos neutral rating 400 Amp and mounting on porcelain support (b) MCCB 4 Pole 400 Amp repturing capacity rating 35 KA - 01 Nos (Incomming)(c) MCCB 4 Pole 100 Amp repturing capacity rating 25 KA - 03 Nos (Outgoing) Note : Cost for all items to be assembled in the panel are deemed to be included in item rate quoated. |
| 69 | Material & Labour in replacement for supply,installing,testing & commissioning in of factory made,IP-54,front and rear opening,locking arrangement cable alley,affix danger notice board out door type sloping conopy top roof epoxy powder coated with seven tank proccess painting of LT panel outdoor type for LT distribution switch gear and control gear,floor mounted ,cubical type modular compartment, dust and vermin proof with neoprene gasket fabricated out of CRCA sheet of thick ness not less than 3.15 mm (CPRI Approved) complete with aluminium bus bar chamber & Cupper Bus bar of four wire system 415 volt with heat shrinkable insulator sleeve suitable for 315 A for phases and for neutral having openable front and rear shutters with suitable locking arrangement epoxy powder spray painted with one coat primercomplete including PCC 1:2:4 type B-1 using 20 mm graded stone agregate foundation raised base angle iron size 50mm x50mmx6mm thick 60cm up and 60cm ground level ,The contractor shall submit the drawing (Genral & Circuit lay out drawing ) for approval by accepting offier /Engr-in-charge before percorument complete all as specified and directed by the Engr in Charge of the following components:- Contractor should arrange factory visit to Engr-in-charge at own arrangement for LT Pannel manufacturing. |
| 70 | (a) INCOMING :- (i)Supply and fix 4 Pole MCCB ,500 Amp 50 Hz 415 V, With Thermal based Release type Capacity 25 KA complete all as specified and directed =01 Nos (incoming)(b) OUTGOING :- (i)Supply and fix 4 Pole MCCB , 200 Amp 50 Hz 415 V, With Thermal based Release type Capacity 25 KA complete all as specified and directed =04 Nos(ii) Supply and fix 4 pole MCCB, 125 Amp 50HZ 415V Thermal based Release type Capacity 25 KA complete all as specified and directed =01 Nos(c) Supply and fix R Y B Phase LED based indicator lamp sets comprising of three colours complete all as specified and directed =01 Set(d) Supply and fix time switches 415 V three Phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and directed =01 Nos(e). Ammeter 0 - 400 Amps, Digital display, flush mounted 3 phase 4 wire with slector switch including CTs of required capacity =01 Nos(f) Voltmeter 0 - 600 Volts, Digital display, flush mounted 3 phase 4 wire with slector switch - 01 Nos(g) complete Internal wiring of suitable size of copper wire Please Enable Macros to View BoQ information |