| 1 | Demolition of reinforced Cement concrete of any description and in any position not specifically provided and removing rubbish out side MD land ,complete all as specified and directed. |
| 2 | M&L for RCC (1:2:4) type B1 using 20mm graded stone aggregate as in manhole cover slab supported on walls and the like complete all as specified and as directed. |
| 3 | M&L for TMT bars 10mm dia and over in dia, cut to length bent to shape required including cranking, bending, hooking ends and binding with MS wire (annealed) not less than 0.9mm dia complete all as specified and as directed. |
| 4 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed. |
| 5 | Ditto-as- above item No 4, exc 1.5 m n. exc.3.0 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. for each additional 1.5m or part thereof in depth beyond the first 1.5 m and getting out complete all as specified and directed. |
| 6 | Returning filling with excavated soil obtained from excavation in layers n exc 25cm including spreading levelling watering and well ramming complete all as specified and as directed. |
| 7 | Removing of old debris of any type obtained from excavation/demolition building material to a distance exc 1.5 Km but n exc 5 Km and deposited out side the MD land complete all as specified and directed.. |
| 8 | M&L for reinforced cement concrete pipe 150 mm dia class NP3 laid and jointed complete with collars as in sewar lines and jointed including Demolition/Breaking up Drain Pipes (SGSW), AC/RCC 150mm dia, Jointed in Cement Mortar of any description including demolition of PCC of the Pipes with Bed, and removing rubbish out side MD land ,complete all as specified and as directed by Engr-in-charge. |
| 9 | M&L for reinforced cement concrete pipe 200 mm dia class NP3 laid and jointed complete with collars as in sewar lines and jointed including Demolition/Breaking up Drain Pipes (SGSW), AC/RCC 300mm dia, Jointed in Cement Mortar of any description including demolition of PCC of the Pipes with Bed, and removing rubbish out side MD land , complete all as specified and as directed by Engr-in-charge. |
| 10 | M&L for reinforced cement concrete pipe 300 mm dia class NP3 laid and jointed complete with collars as in sewar lines and jointed including Demolition/Breaking up Drain Pipes (SGSW), AC/RCC 300mm dia, Jointed in Cement Mortar of any description including demolition of PCC of the Pipes with Bed, and removing rubbish out side MD land ,complete all as specified and as directed by Engr-in-charge. |
| 11 | M&L for Cement Concrete (1:4:8) Type D2 (20mm Graded Stone Aggregate) Bed for Drain Pipes of Bore 150mm including Packing under and Haunching against the Sides of Pipes after they are laid in Foul Condition and Testing, complete all as specified and as directed. |
| 12 | M&L for Cement Concrete (1:4:8) Type D2 (20mm Graded Stone Aggregate) Bed for Drain Pipes of Bore 200 mm including Packing under and Haunching against the Sides of Pipes after they are laid in Foul Condition and Testing, complete all as specified and as directed. |
| 13 | M&L for Cement Concrete (1:4:8) Type D2 (20mm Graded Stone Aggregate) Bed for Drain Pipes of Bore 300 mm including Packing under and Haunching against the Sides of Pipes after they are laid in Foul Condition and Testing, complete all as specified and as directed. |
| 14 | M&L cement concrete 1:4:8 type D2 using 40mm graded stone aggregate for foundation of manholes,sub base of flooring,etc. complete all as specified and directed. |
| 15 | M&L cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in benching including necessary form work complete all as specified and directed. |
| 16 | Cutting into existing manholes for connecting new drains of 150/200/300mm bore dia making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 Section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as directed . |
| 17 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and directed. |
| 18 | M&L cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate as in bed blocks, coping,benching,bed block for rungs,window cills etc including necessary form work complete all as specified and directed. |
| 19 | Demolition of brick work build in cement morter of any description and removing rubbish out side MD land ,complete all as specified and directed. |
| 20 | M & L for old size brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified & directed by Engr-in-Charge. |
| 21 | Taking down Cement Plaster from wall of any description from Brick/block masonary/concrete surfaces including raking out Joints, hacking for Key, scrubbing down with Water, etc., and removing rubbish out side MD land ,complete all as specified and directed. |
| 22 | M & L Rendering 15mm thick in cement mortar 1:4 on brick surfaces finished even smooth with liquid water proofing compound as per manufacturers instrucitons. (Note :- WPC shall be measured and paid separately) |
| 23 | Supply only liquid water proofing compound |
| 24 | Demolition of Cement Concrete (un-reinforced) of any description, not exc. 150mm thickness (above or below Ground Level) and removing rubbish out side MD land ,complete all as specified and directed. |
| 25 | M&L for 100mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in floor and paving including finishing even and smooth without using extra cement complete all as specified and directed by Engr-in-charge |
| 26 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweeping extrasand; complete all as specified and directed. |
| 27 | M&L in repair for rubber moulded Chequered Cement Concrete Tiles 300X300X 20mm thick pre printed colour, Set and Jointed in Neat Cement Slurry with Grey Cement and Pigment over and including Screed Bed 15mm thick in Cement Mortar (1:6) as in Path, complete all as specified and as directed. |
| 28 | Demolition and breaking of drain pipes AC /CI/PVC set in cement mortar or adhensive all as directed of 75mm to 110 mm dia |
| 29 | S&F in repair PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in floors/in earth of 110 mm dia. |
| 30 | S&F in repair PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in floors/in earth of 75 mm dia. |
| 31 | S&F PVC (SWR) bends plain 110 mm bore |
| 32 | S&F PVC(SWR) bends plain 75mm bore |
| 33 | S&F PVC (SWR) bends with oval access door of 75 mm bore |
| 34 | S/F PVC SWR Branch piece single (Single Y) equal or unequal 110mm dia with door access. |
| 35 | S/F PVC SWR Branch piece single (Single Y) equal or unequal 75 mm dia with door access. |
| 36 | S&F PVC (SWR) of 110mm dia junction single (single 'T') equal or unequal with door access. |
| 37 | S&F PVC (SWR) of 75 mm dia junction single (single 'T') equal or unequal with door access. |
| 38 | S/F PVC SWR Branch piece double (double 'Y') equal or unequal 110mm dia with door access. |
| 39 | S/F PVC SWR Branch piece double (double 'Y') equal or unequal 75mm dia with door access. |
| 40 | S&F for 110 mm dia PVC SWR vent cowl |
| 41 | S&F for 75 mm dia PVC SWR vent cowl. |
| 42 | M&L for mild steel clamps, bands straps, supports or stays for soil waste pipe & rain water pipes including fixing clamps with coach screws etc complete all as spd and directed. Please Enable Macros to View BoQ information |