| 1 | BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) File No 8105/E8 Tender Inviting Authority: GARRISON ENGINEER GOLCONDA Name of Work: REPAIR / REPLACEMENT OF LT PANELS, LT UG CABLES, LIGHTNING ARRESTERS, EARTHINGS AT 9 MT, 17 DOGRA,TARAMATI, IB LINES AND APS, AMMUNITION DUMP UNDER GE GOLCONDA Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of work Item Code / Make No or Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder including all TaxesRs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for foundation, laying of poles, cables in trenches and getting out in soft/loose soil complete all as directed and specified. |
| 3 | Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as all as specified and directed. |
| 4 | Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtrs above from the starting point complete all as all as specified and directed. |
| 5 | Supply and spread approved dry river sand for cushioning of cable including watering and consolidation, laid in trenches complete all as specified and directed. Note:- Punned thickness shall be measured for payment purpose |
| 6 | M&L brick protection with common burnt bricks sub class ‘B’ of size 230 x 113 x 75mm for cable protection complete all as specified and directed. |
| 7 | M & L for cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable/pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed. |
| 8 | Supply, Laying, testing & commissioning XLPE insulated, PVC sheathed heavy duty LT 1100 Volts grade armoured UG cable 4 Core 16 Sqmm with stranded aluminium conductor in trenches/ fixed to walls/ poles etc. including taking out of existing cable complete all as specified and directed. |
| 9 | Supply, Laying, testing & commissioning XLPE insulated, PVC sheathed heavy duty LT 1100 Volts grade armoured UG cable 3.5 Core 25 Sqmm with stranded aluminium conductor in trenches/ fixed to walls/ poles etc. including taking out of existing cable complete all as specified and directed. |
| 10 | Supply, Laying, testing & commissioning XLPE insulated, PVC sheathed heavy duty LT 1100 Volts grade armoured UG cable 3.5 Core 35 Sqmm with stranded aluminium conductor in trenches/ fixed to walls/ poles etc. including taking out of existing cable complete all as specified and directed. |
| 11 | Supply, Laying, testing & commissioning XLPE insulated, PVC sheathed heavy duty LT 1100 Volts grade armoured UG cable 3.5 Core 50 Sqmm with stranded aluminium conductor in trenches/ fixed to walls/ poles etc. including taking out of existing cable complete all as specified and directed. |
| 12 | Supply, Laying, testing & commissioning XLPE insulated, PVC sheathed heavy duty LT 1100 Volts grade armoured UG cable 3.5 Core 70 Sqmm with stranded aluminium conductor in trenches/ fixed to walls/ poles etc. including taking out of existing cable complete all as specified and directed. |
| 13 | Supply, Laying, testing & commissioning XLPE insulated, PVC sheathed heavy duty LT 1100 Volts grade armoured UG cable 3.5 Core 95 Sqmm with stranded aluminium conductor in trenches/ fixed to walls/ poles etc. including taking out of existing cable complete all as specified and directed. |
| 14 | Supply, Laying, testing & commissioning XLPE insulated, PVC sheathed heavy duty LT 1100 Volts grade armoured UG cable 3.5 Core 120 Sqmm with stranded aluminium conductor in trenches/ fixed to walls/ poles etc. including taking out of existing cable complete all as specified and directed. |
| 15 | Supply, Laying, testing & commissioning XLPE insulated, PVC sheathed heavy duty LT 1100 Volts grade armoured UG cable 3.5 Core 185 Sqmm with stranded aluminium conductor in trenches/ fixed to walls/ poles etc. including taking out of existing cable complete all as specified and directed. |
| 16 | Supply, Laying, testing & commissioning XLPE insulated, PVC sheathed heavy duty LT 1100 Volts grade armoured UG cable 3.5 Core 240 Sqmm with stranded aluminium conductor in trenches/ fixed to walls/ poles etc. including taking out of existing cable complete all as specified and directed. |
| 17 | Supply & Laying 100 mm bore GI tubing, light grade, with all fittings of following sizes for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and directed. |
| 18 | Supply & Laying 80 mm bore GI tubing, light grade, with all fittings of following sizes for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and directed. |
| 19 | Supply & Laying 50 mm bore GI tubing, light grade, with all fittings of following sizes for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and directed. |
| 20 | Supply & Laying 40 mm bore GI tubing, light grade, with all fittings of following sizes for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and directed. |
| 21 | S & F cable end termination jointing kit heat shrinkable type for 1.1 KV (earthed) grade cable for outdoor with jointing material and accessories suitable for 3.5 core of size 25 sqmm to 70 Sqmm complete including taking out old unserviceable end termination jointing kit complete all as specified and directed. |
| 22 | S & F cable end termination jointing kit heat shrinkable type for 1.1 KV (earthed) grade cable for outdoor with jointing material and accessories suitable for 3.5 core of size 95 sqmm to 150 Sqmm complete including taking out old unserviceable end termination jointing kit complete all as specified and directed. |
| 23 | S & F cable end termination jointing kit heat shrinkable type for 1.1 KV (earthed) grade cable for outdoor with jointing material and accessories suitable for 3.5 core of size 185 sqmm to 240 Sqmm complete including taking out old unserviceable end termination jointing kit complete all as specified and directed. |
| 24 | S and F cable jointing kit, outdoor heat shrinkable type straight through joint for 1.1 KV (Earthed) grade cable with jointing material and accessories suitable for cable of size 3.5 core 25 to 70 Sqmm including taking out old unserviceable joint kit straight through type complete all as specified and directed. |
| 25 | S and F cable jointing kit, outdoor heat shrinkable type straight through joint for 1.1 KV (Earthed) grade cable with jointing material and accessories suitable for cable of size 3.5 core 95 to 150 Sqmm including taking out old unserviceable joint kit straight through type complete all as specified and directed. |
| 26 | S and F cable jointing kit, outdoor heat shrinkable type straight through joint for 1.1 KV (Earthed) grade cable with jointing material and accessories suitable for cable of size 3.5 core 180 to 240 Sqmm including taking out old unserviceable joint kit straight through type complete all as specified and directed. |
| 27 | Supply, Fixing and stringing ACSR Conductor steel reinforced of type as directed including stretching, binding using ACSR conductor on insulator on overhead line including taking down of existing conductor complete all as specified and directed. |
| 28 | Stringing only ACSR Conductor of any type as directed including binding using ACSR conductor on insulator on overhead line, complete all as specified and directed. |
| 29 | M&L for Mild steel Cross arm bracing support clamps and back plates fabricated from structural steel sections including nuts, bolts and washers, welding, bending cold or hot drilling holes for bolts in any shape or sizes as indicated or directed inclusive of one coat of red oxide zinc chrome primer and two coats of aluminium paint and removing the existing cross arms etc complete all as specified and directed. |
| 30 | M&L for Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two glavanised iron washers and one galvanised iron nut,100mm height, 65mm dia for 1100 Volts grade, including taking down existing insulator complete all as specified and directed. |
| 31 | M&L for Shakle type, porcelain, vitreous, white brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts 100mm in height, 115mm dia, working pressure 1100 volts, section of strap 31X5, 14mm dia bolts including taking down the existing insulator complete all as specified and directed. |
| 32 | S&F Stay assembly complete with accessories as shown in electric plate No.1, stay rod 16mm dia, including dismantling, demolition of concrete and taking out old unserviceable stay assembly complete all as specified and directed. (Excavation , PCC, Loop type insulator,stay strand measured and paid separately) |
| 33 | S&F Galvanised stay strand 7/3.15 mm complete all as specified and directed. |
| 34 | S&F Loop type insulator porcelain, vitreous, white brown or green in colour small size with overall dimension 65 x 95 mm, clearance of hole 16 mm complete all as specified and directed. |
| 35 | M&L for cement concrete for foundation, filling and mass concrete type C2 1:3:6 with 40 mm graded aggregate for steel tubular swaged poles/ stay foundations complete all as specified and directed. |
| 36 | M&L for cement concrete for coping, type B1 1:2:4 with 20 mm graded aggregate including necessary form work for steel tubular swaged poles complete all as specified and directed. |
| 37 | Cutting & trimming of tree branches any girth and size touching to overhead lines and cleaning the distance 1.5 mtr both sides of overhead line with in a gap of span 40 mtrs each and removing the same cleaning the site all as specified and directed. |
| 38 | S&F PVC separators suitable for LT over head line of 4 conductors all as specified and directed. |
| 39 | M&L for cleaning thoroughly LT distribution steel poles of any height and any description (Maximum 9 Mtr long) with necessary cleaning agent including scrapping of old corroded paint dirt/ rust carefully and applying two coats aluminium paint including marking of pole numbers and colour washing of pole coping complete all as specified and directed . |
| 40 | Supply and erect Steel tubular swaged pole, 9.0 metres long complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified, type 410 SP-31 applying two coats of bituminous paint internally and externally for the portion embedded in concrete and two coats of aluminium paint over one coat of red oxide primer to external/ exposed surfaces including dismantling, taking down carefully the existing unserviceable Steel tubular swaged Pole, serviceable street light fitting, ACSR conductor and connecting accessories and refixing the same after replacing the new pole with all necessary accessories complete all as specified and directed. ( Note:- Excavation and PCC will be paid separately ) |
| 41 | Supply, install, test and commission CPRI APPROVED factory fabricated, outdoor type, LT FEEDER PILLAR BOX made out of 3.15mm thick CRCA sheet of size 1M x 0.75M x 0.35M with projected globe roof for rainwater protection dust and vermin proof, double door with both side opening including neoprene rubber gasket, suitable for 440 Volt 3 Phase 4 Wire System, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers etc. and embedded with 50x50x6mm MS angle iron frame, 600mm above the normal ground level complete with internal connection with suitable size of cable, cable lugs and cable glands, PCC foundation in cement concrete 1:3:6 (20mm graded stone aggregate) complete all as specified and comprising of the following :-(a) Aluminium busbar 200 amps - 04 Nos, supported on suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow, blue and block) for three phases and neutral.(b) MCCB 125 amps, 415 volt, 16 KA breaking capacity 4 pole electromagnetic release duly connected to busbar as incoming - 01 No. |
| 42 | S&F in repair galvanised iron strip of size 32x6mm complete all as specified and directed. |
| 43 | S&F in repair galvanised iron strip of size 25x4mm complete all as specified and directed. |
| 44 | S&F, in repair, SS Enclosure with frame cubical type wall mounted front operated on-load changeover switch of capacity 400 Amps 415 volts, 4 pole including necessary electric connection with suitable size aluminium lugs complete all as specified and directed. |
| 45 | S&F, in repair, SS Enclosure with frame cubical type wall mounted front operated on-load changeover switch of capacity 200 Amps 415 volts, 4 pole including necessary electric connection with suitable size aluminium lugs complete all as specified and directed. |
| 46 | S&F, in repair, SS Enclosure with frame cubical type wall mounted front operated on-load changeover switch of capacity125 Amps 415 volts, 4 pole including necessary electric connection with suitable size aluminium lugs complete all as specified and directed. |
| 47 | M&L for repair of existing LT panel outdoor/indoor type by properly fixing loose/dislocated MS doors complete with provision of hinges and welding at locations as necessary, provision of tower bolt as per as existing size including painting of internal and external surfaces with one coat of synthetic enamel paint of approved colour after preparation of old painted surfaces complete as required for smooth operation of panel and as directed by the Engr-in-charge (Size of Panel board n.exc 2.25x1.2x0.6 m) NOTE: Cost of MS sheet, Tower bolt, sliding bolt as required shall be included in the unit rate quoted by the Contractor. |
| 48 | M&L for Earthing complete with galvanized steel with plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth kit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized steel strip 32 x 6 mm by means of bolts, nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part-I connected to earth test point including necessary earth work and excavation, PCC 1:3:6 type C1 using 20mm graded stone aggregate for earth chamber with RCC cover 50mm thick 1:2:4 mix type B1, using 8mm dia TMT bars reinforcement @ 140mm c/c both ways, watering funnel with GI pipe 20 mm dia medium grade and protection pipe GI 40 mm dia medium all as specified and directed. (Note: Earth strip and protection pipe beyond 7.5m shall be measured and paid separately.) |
| 49 | Disconnecting existing panel and its connections and supply, install, testing and commissioning CPRI APPROVED factory fabricated powder coated, outdoor type, LT FEEDER PANEL of made out of 3.15mm thick CRCA sheet of suitable size with projected globe roof for rainwater protection dust and vermin proof, double door (including locking arrangement) with both side opening including neoprene rubber gasket, suitable for 440 Volt 3 Phase 4 Wire System, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers etc. with panel control copper wiring, accessories fitted on suitable insulator all housed in suitable size chamber and fixing of digital Voltmeter, Ammeter with built in selector switch, CT's of suitable ratio, pilot indication lamps including internal connection with suitable size of cable, cable lugs and cable glands, panel embedded with 50x50x6mm mild steel angle iron frame 600mm above the normal ground level complete, PCC foundation 1:4:8 (using 40mm graded stone aggregate) and testing after installation complete all as specified and including the cost of the following :-(a) Aluminium busbar 800 amps size 50mm x 10mm - 04 Nos, supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.(b) MCCB 400 amps, 415 volt, 50 KA breaking capacity 4 pole - 01 Nos ( as incoming)(b) MCCB 250 amps, 415 volt, 36 KA breaking capacity 4 pole - 03 Nos( as outgoing)(c) MCCB 160 amps, 415 volt, 36 KA breaking capacity 4 pole - 02 Nos( as outgoing) (d) MCCB 100 amps, 415 volt, 16 KA breaking capacity 4 pole - 01 Nos( as outgoing) (e) Three phase panel mounted digital type voltmeter 0-500 volts, selector switch and Ammeter 0-500 Amps with selector switch and LT-CT operated complete - 01 Set(f) Phase indicating lamp LED type for Red, Yellow and Blue - 01 Set |
| 50 | M&L for MCCB 415 Volts, 4 pole, Fixed type, 125 Amps, with breaking capacity 16 KA with all connected accessories including taking out old un-serviceable MCCB all as specified and directed. |
| 51 | M&L for MCCB 415 Volts, 4 pole, adjustable type, 160 Amps, with breaking capacity 36 KA complete with all connected accessories including taking out old un-serviceable MCCB all as specified and directed. |
| 52 | M&L for MCCB 415 Volts, 4 pole, adjustable type, 200 Amps, with breaking capacity 36 KA complete with all connected accessories including taking out old un-serviceable MCCB all as specified and directed. |
| 53 | M&L for MCCB 415 Volts, 4 pole, adjustable type, 250 Amps, with breaking capacity 36 KA complete with all connected accessories including taking out old un-serviceable MCCB all as specified and directed. |
| 54 | M&L for MCCB 415 Volts, 4 pole, adjustable type, 400 Amps, with breaking capacity 36 KA complete with all connected accessories including taking out old un-serviceable MCCB all as specified and directed. |
| 55 | Supply, fix, connect commission and test power capacitor bank MPP out door type operating 3 phase 415 volt AC supply 50 HZ confirmed to IS:2834 complete with necessary bolts and nuts, earth strip connected from LT panel to capacitor bank including suitable copper cable single core multistranded with necessary lugs for inter connection of capacitor bank 5 KVAR complete, including disconnecting and removing existing unserviceable power capacitor bank. and all as specified and as directed. |
| 56 | All as per item No.54above but 10 KVAR |
| 57 | All as per item No.54 above but 15 KVAR |
| 58 | All as per item No.54 above but 20 KVAR |
| 59 | S & Fix, connect and test Capacitive Duty Contactor for capacity 1 KVAR to 3 KVAR capacitor bank, including disconnecting and removing existing unserviceable duty contactor complete all as specified and as directed. |
| 60 | All as per item No.58 above but for 5 KVAR to 15 KVAR |
| 61 | All as per item No. 58 above but for 20 KVAR |
| 62 | Supply, Installation, testing and commissioning of Automatic Power Factor Correction (APFC) panel,outdoor type floor mounted for following capacity of 60 KVAR with due consideration of number of steps, capacitors i.e. 1 KVAR, 2 KVAR, 3 KVAR, 5 KVAR, 10 KVAR, 25 KVAR, 20 KVAR for smooth correction MD-XL Capacitor with ISI marked and Suitable capacity of MCCB Microprocessor base with O/C, S/C, E/L release of TPN 50KA breaking capacity with conntractar, Auto Manual Selector switch, auxiliary contactors, Digital Multi function meter with LED Display for V, A, PF, KW, KVA, KVAR, THD-V & I, Frequency. including internal control wiring shall be done by using 2.5 sq mm, FRLS/HFFR 1100 V grade, PVC insulated multi stranded copper wire complete 3 phase, 415 V , 50 Hz AC System for Ambient temperature -5°C to +40°C, fabricated in compartmentalised designed made of CRCA sheet steel of 2.0mm thick for framework & covers, 3 mm thick for gland plate i/c cleaning & finishing complete with powder coated of approved shade Siemens Gray or as approved by Engineer-in-Charge, having suitable current carrying capacity, extensible TPN Aluminium alloy bus bar of high conductivity, DMC/SMC bus bar supports, bottom base channel of MS Section, panel shall have common earth bar of minimum size of 25mm x 5mm with 2 nos. earth studs, complete all as specified and directed. Make : L & T or Techno commercially equivalent make as listed in list of makes and as dpproved by GE. |
| 63 | S&F in repair test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hexagonal headed screws complete all as specified and directed. |
| 64 | S&F in repair Air termination, single pointed aluminium rod 12mm dia and 300 mm long complete all as specified and directed. |
| 65 | S&F in repair aluminium strip of size 25 x 3.15 mm with saddles and fixing screws etc, for roof conductors and down conductors above ground level complete all as specified and directed. |
| 66 | M&L for surface dressing up to 15 cm in depth including cleaning of vegetation, removing grass, small plants and other unwanted material and levelling inside substations and surrounding area and removal of excavated materials at a distance not exc 50 m where directed complete all as specified and as directed. |
| 67 | Removing Existing unserviceable Analog voltmeter with electrical connections and supply, install and testing new analog voltmeter 0-500V complete all as specified and directed. |
| 68 | Removing Existing unserviceable Analog ammeter with electrical connections and supply, install and testing new analog ammeter 0-250A/100A with necessary wires & CTs complete all as specified and directed. |
| 69 | M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT, 20 x 15 cm size including taking down old plate complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |