| 1 | BoQ BOQ Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GARRISON ENGINEER TEZPUR (NORTH) NAME OF WORK : REPAIR/MAINT OF DAY TO DAY MAINTENANCE OF INTERNAL WIRING OF MES INSTALLATIONS, LIGHT FITTINGS, SWITCHES, LED FITTINGS AND OTHER ALLIED WORKS IN SECTOR V TO XI AT AGE CHARDUAR UNDER GE (N) TEZPUR. Contract No : GE(N)/TEZ/ OF 2026-2027 (File No. 8270/E8) Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Description of items of works Item Code / Make Approx No. of quentity required. Units Pre Priced Rate (in. Rs.) as Defined by MES Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures to be entered by the Bidder Rs. P. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT (In INR) TOTAL AMOUNT With Taxes TOTAL AMOUNT (In Words) |
| 2 | M&L for point wiring for one light point/fan point controlled by one way switch 5/6 amps with 1.5 sqmm single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with multistranded copper conductor with proper colour coding drawn through and including rigid PVC medium grade casing caping and accessories (ISI Marked) fixed on wall/fixed to roof, ceiling etc including provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI Marked) with proper colour coding as earth continuity conductor connected to common earth dolly, including pressed steel terminal boxes 1.6 mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium screws for housing the switchs,sockets, fan regulators etc, Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles including taking down of old unserviceable existing point wiring complete all as specified and directed.Notes : The quoted rate shall be include chase cutting, making good to the disturbed surfaces including plastering and painting to match with the existing colour. |
| 3 | All as per Item No 01 ditto but for one 3 pin socket outlet 5 amps on the same board controlled by one switch complete all as specified and directed. |
| 4 | All as per Item No 01 ditto but for One 3 pin socket outlet 5 amps on independent board controlled by one switch complete all as specified and directed. |
| 5 | All as per Item No 01 ditto but for One bell/buzzer point controlled by one bell push complete all as specified and directed. |
| 6 | All as per Item No 01 ditto but for One socket outlet three pin 15 amps control by one switch independent board with cable 2.5 sqmm size (two run) & 2.5sqmm (one run) complete all as specified and directed. |
| 7 | S&F switch piano flush type, 5 Amp single pole, one way, 230 volt, ISI marked complete all as specified and directed by Engr-in Charge |
| 8 | S&F socket outlet 2 in 1, 3 pin, 5 Amp, 230 volts ISI marked complete all as specified and directed by Engr-in Charge |
| 9 | S&F switch piano flush type, 15 Amp single pole, one way, 230 volt, ISI marked complete all as specified and directed by Engr-in Charge |
| 10 | S&F socket outlet 2 in 1, 3 pin, 15 Amp, 230 volts ISI marked complete all as specified and directed by Engr-in Charge |
| 11 | S&F bell push 5 amps 230 volts flush type complete all as specified and directed by Engr-in Charge |
| 12 | S&F for flush type bell push, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and directed. |
| 13 | S&F in ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed. |
| 14 | S&F Electronic fan regulator dimmer type, 250 volt suitable for 1200/1400 mm sweep energy saving fans, ISI marked complete all as specified and directed by Engr-in Charge |
| 15 | Re- fixing for Ceiling Fan after cleaning including taking down carefully of any size/any type after disconnecting the electric connection and re-connecting the fans to ceiling rose/connector after necessary servicing complete all as specified and directed by Engr-in Charge |
| 16 | S&F in repair lamp holder insulated body with back plate for batten fittings/angle holder as required and including taking down old damaged holder complete all as specified and directed. |
| 17 | S&F in repair LED bulb 12 w high sutable for lamp holder 230V Base-22 complete all as specified and directed. |
| 18 | S&F IP 20, class I, LED light 1X18 W (or nearest next higher wattage) (4 feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc with all accessories internally prewired and connecting up including taking down of old unserviceable existing light fitting complete all as specified and directed. |
| 19 | S&F IP 20, class I, LED light 1X18 W (or nearest next higher wattage) (4 feet), warm White with colour temperature 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc with all accessories internally prewired and connecting up including taking down of old unserviceable existing light fitting complete all as specified and directed. |
| 20 | S&F IP 20, Class I, LED Mirror light fitting 1 x 10 W, (or nearest next higher wattage) 5700 K, wall /Surface mounted with aluminium housing 2 feet long, integrated type, with high efficiency PMMA diffuser, integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc complete including 01 No 10 W LED lamp with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size including taking down of old unserviceable existing light fitting complete all as specified and directed. |
| 21 | S&F 36Watts 2 x 2 Panel Light(Cool White) Environment friendly, new generation, aesthatically, ultra modern designed Recess mounting luminaire with high brightness SMD LEDs as light source suitable for Armstrong/Grid ceiling all as per Cat LHEBAEP7IW1W036 of Havells or equivalent of other specified makes fixed to ceiling including taking down the old fitting all as specified and as directed by the Engineer-in-Charge. Make : HAVELLS CG/Philips /Wipro/Surya |
| 22 | S&F 36Watts 2 x 2 Panel Light(Warm White with Colour Temp 3000K) Environment friendly, new generation, aesthatically, ultra modern designed Recess mounting luminaire with high brightness SMD LEDs as light source suitable for Armstrong/Grid ceiling all as per Cat LHEBAEP5IW1W036 of Havells or equivalent of other specified makes fixed to ceiling including taking down the old fitting all as specified and as directed by the Engineer-in-Charge. Make : HAVELLS CG/Philips /Wipro/Surya |
| 23 | S&F of Bulk head luminaire suitable for 10 Watt LED (or nearest next higher wattage) light IP66 grade, luminaire efficiency not less than 120 lumens/watts with and including 10 watt LED (or nearest next higher wattage) lamp and connecting up with and including PVC insulated 3 core of size 0.75 Sqmm copper conductor from ceiling rose to terminal block of light fitting including taking down of old unserviceable existing light fitting complete all as specified and directed. |
| 24 | Material and labour for concealed sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid casing caping (medium grade) of of size not less than 25 mm with all fittings and accessories ISI marked including complete, including taking down old unsv aluminium submain wiring complete all as specified and directed. NOTE : (i) Two runs of 4 sqmm conductor for main and one run of 4 sqmm conductor as earth wire with proper colour coding including one run run of PVC casing caping shall be measured as one unit length. Connections of cables with MCBs or bus bar shall be done through appropriate size brass/ copper thimbles.(ii) Rate for taking down old unsv aluminium submain wiring deemed to be included in the quotated rate. |
| 25 | Material and labour for concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid casing caping (medium grade) of of size not less than 25 mm with all fittings and accessories ISI marked including complete, including taking down old unsv aluminium submain wiring complete all as specified and directed. NOTE : (i) Two runs of 6 sqmm conductor for main and one run of 6 sqmm conductor as earth wire with proper colour coding including one run run of PVC casing caping shall be measured as one unit length. Connections of cables with MCBs or bus bar shall be done through appropriate size brass/ copper thimbles.(ii) Rate for taking down old unsv aluminium submain wiring deemed to be included in the quotated rate. |
| 26 | Material and labour for concealed sub-main wiring alongwith earth wire of size of 2 x 10.0 sq. mm + 1x10.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid casing caping (medium grade) of of size not less than 25 mm with all fittings and accessories ISI marked including complete, including taking down old unsv aluminium submain wiring complete all as specified and directed. NOTE : (i) Two runs of 6 sqmm conductor for main and one run of 6 sqmm conductor as earth wire with proper colour coding including one run run of PVC casing caping shall be measured as one unit length. Connections of cables with MCBs or bus bar shall be done through appropriate size brass/ copper thimbles.(ii) Rate for taking down old unsv aluminium submain wiring deemed to be included in the quotated rate. |
| 27 | Supply and fixing of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 8, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc flushed on the existing wall , to match with existing surface and making all necessary connections including taking down of old unserviceable existing DB complete all as specified and directed. |
| 28 | Supply and fixing of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 6, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc flushed on the existing wall , to match with existing surface and making all necessary connections including taking down of old unserviceable existing DB complete all as specified and directed. |
| 29 | Supply and fixing of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 4, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc flushed on the existing wall , to match with existing surface and making all necessary connections including taking down of old unserviceable existing DB complete all as specified and directed. |
| 30 | Supply and fixing of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, TPN 8, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc flushed on the existing wall , to match with existing surface and making all necessary connections including taking down of old unserviceable existing DB complete all as specified and directed. |
| 31 | Supply and fixing of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, TPN 6, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc flushed on the existing wall , to match with existing surface and making all necessary connections including taking down of old unserviceable existing DB complete all as specified and directed. |
| 32 | Supply and fixing of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, TPN 4, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc flushed on the existing wall , to match with existing surface and making all necessary connections including taking down of old unserviceable existing DB complete all as specified and directed. |
| 33 | S&F in reapir isolator MCB of rating 100 Amps, TPN, 415 Volts, ‘C’ curve, breaking capacinty 10KA complete all as specified and directed. |
| 34 | S&F in reapir MCB, Triple pole & neutral (TPN) 63-100 Amps, 240 volts, ‘C’ curve, breaking capacinty 10KA complete all as specified and directed. |
| 35 | S&F in reapir MCB of rating 240 Volts, SPN, 63 Amps, 240 volts, ‘C’ curve, breaking capacinty 10KA complete all as specified and directed. |
| 36 | S&F in reapir MCB of rating 240 Volts, SPN, 40 Amps, 240 volts, ‘C’ curve, breaking capacinty 10KA complete all as specified and directed. |
| 37 | S&F in reapir MCB of rating 240 Volts, SP, 6-32 Amps, 240 volts, ‘C’ curve, breaking capacinty 10KA complete all as specified and directed. |
| 38 | S&F in reapir MCB of rating 240 Volts, SP, 40 Amps, 240 volts, ‘C’ curve, breaking capacinty 10KA complete all as specified and directed. |
| 39 | S&F for epoxy powder coated sheet metal enclosure with socket plug top and MCB, single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amps, 240 Volts, C Series current carrying capacity 10 kA, incl necessary connection and taking down of old unserviceable existing DB complete all as specified and directed |
| 40 | S&F in repair CPVC Conduit, medium grade, 25mm dia including conduit accessaries for cable passing through trench/fixed on walls or ceilings /Raising through poles complete all as specified and directed. |
| 41 | S&F in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 sqmm 2 core complete all as specified and as directed. |
| 42 | Supply only switch piano flush type, 5 Amp single pole, one way, 230 volt, ISI marked complete all as specified and directed by Engr-in Charge |
| 43 | Supply only socket outlet 2 in 1, 3 pin, 5 Amp, 230 volts ISI marked complete all as specified and directed by Engr-in Charge |
| 44 | Supply only switch piano flush type, 15 Amp single pole, one way, 230 volt, ISI marked complete all as specified and directed by Engr-in Charge |
| 45 | Supply only socket outlet 2 in 1, 3 pin, 15 Amp, 230 volts ISI marked complete all as specified and directed by Engr-in Charge |
| 46 | Supply only 5m long LED Strip, 24 W, Warm White (Colour Temp 3000K), with constant Voltage 12V 2A driver for 24 W Strip, copper PCB for improved heat dissipation complete all as specified and as directed by the Engineer-in-Charge |
| 47 | Supply only LED Light Strip 18 mtr,144 W, IP65 Protection,tricolour 5mtr suitable driver for Strip Light, copper PCB for improved heat dissipation complete all as specified and as directed by the Engineer-in-Charge |
| 48 | S&F in replacement of copper flexible cable, PVC insulated, 6sqmm, 3 core, 70/.0076 complete all as specified and as directed by the Engineer-in-Charge |
| 49 | Supply only for LED bulb 12 w (Cool White), B-22 sutable for lamp holder complete all as specified and as directed by the Engineer-in-Charge. |
| 50 | Supply only for LED bulb 12 w,(warm white), B-22 suitable for lamp holder complete all as specified and as directed by the Engineer-in-Charge. |
| 51 | Supply only for Surface mounted LED COB Light fixture with 7 W Led light with pressure die cast aluminium heat shrink & clear PC as a cover in while powder coated finish with integrated electronic LED driver omplete all as specified and as directed by the Engineer-in-Charge. |
| 52 | Supply only for 20Watts LED light fitting(Cool white), basic all purpose surface and wall mounted LED batten fixture with extruded polycarbonate and integrated electronic driver including 20W LED tube - 1No. all as per Cat No.LHEXAWP7UN1W020 (LED Pride essential) of Havells or equivalent of other specified makes fixed on surfaces of wall or ceiling including taking down the old fitting all as specified and as directed by the Engineer-in-Charge. |
| 53 | Supply only for 20Watts LED light fitting(Warm White), basic all purpose surface and wall mounted LED batten fixture with extruded polycarbonate and integrated electronic driver including 20W LED tube of Havells or equivalent of other specified makes fixed on surfaces of wall or ceiling including taking down the old fitting all as specified and as directed by the Engineer-in-Charge. |
| 54 | Supply Only LED ROUND PANEL light (Cool White)18 W, Slim profile, Compact aluminium die cast edge lit panel light, recessed type with opal diffuser and electronic driver complete all as specified and directed. |
| 55 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 16 sqmm 2 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ. |
| 56 | Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft / loose soil complete all as specified and as directed. |
| 57 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified and as directed. |
| 58 | Removing excavated material / soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 59 | Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and directed. |
| 60 | Supply and laying well burnt bricks sub class 'B' in trenches for cable protection of U/G cable complete all as specified and directed. |
| 61 | S & F in replacement of PVC switch boards, closed recessed suitable for surfaces, sizes 4 X 4 (Inches) complete all as specified and as directed. |
| 62 | S & F in replacement of PVC switch boards, closed recessed suitable for surfaces, sizes 4 X 7 (Inches) complete all as specified and as directed. |
| 63 | S & F in replacement of PVC switch boards, closed recessed suitable for surfaces, sizes 8 X 6 (Inches) complete all as specified and as directed. |
| 64 | S & F in replacement of PVC switch boards, closed recessed suitable for surfaces, sizes 8 X 10 (Inches) complete all as specified and as directed. |
| 65 | S & F in replacement of PVC insulated copper conductor cable, FRLSH, single core, 1100 Volts, 1.5 Sq mm with colour coding complete all as specified and directed. |
| 66 | S & F in replacement of PVC insulated copper conductor Cable, FRLSH, single core, 1100 Volts, 2.5 Sq mm with colour coding complete all as specified and directed. |
| 67 | S & F in replacement of PVC insulated copper conductor Cable, FRLSH, single core, 1100 Volts, 4.0 Sq mm with colour coding complete all as specified and directed. |
| 68 | S & F in replacement of PVC insulated copper conductor Cable, FRLSH, single core, 1100 Volts, 6.0 Sq mm with colour coding complete all as specified and directed. |
| 69 | Earthing in replacement complete with galvanised steel earth plate electrode 60cm x 60 cm x 6.3 mm thick burried directly in ground vertically to a depth not less than 2.25m deep below ground level with top edge of plate not less than 1.5 below ground level connected to GI 4mm earth wire by means of bolts, nuts check nuts washers made of galvanised iron or steel earth wire protected by GI pipe 15 mm bore light grade connected upto switch board incl 20mm bore GI water pipe with funnel and wire mesh all as shown in electrical plate No.3 of SSR Part I including dearth chamber of PCC 1:2:4 type B1 using 20mm grade aggregate with RCC cover slab 1:2:4 type B1, 40mm thick with 15mm dia MS bar 100mm C/C both ways and 6 MM dia MS hooks complete all as specified inlcuding testing on completion. Note: This rate shall be includes excavation & Earthwork needed for making earthpit etc. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |