| Sl. No. | Item Description |
| 1 | Taking down cement plaster on brick, stone or concrete surface including racking out joints hacking for key scrubbing down with water to receive plaster etc complete all all as specified and as directed by Engineer-in-charge. |
| 2 | M & L for rendering 10mm thick in CM (1:6) on surfaces of brick work/ stone masonry /concrete surface of wall, finished even and smooth without using extra cement complete all all as specified and as directed by Engineer-in-charge. |
| 3 | M&L for Preparation of newly plaster surfaces of wall by hand held sander/ long handle sander including cornices, pilasters etc completed all as specified directed and applying two coat of oil bound distemper over a coat of alkali resistant priming paint with roller finish complete all as specified and as directed by Engineer-In-Charge. |
| 4 | Dismantaling floor, hearth or wall tiling including cement motar bedding(but not backing) removing servicable tiles to store and rubbish off premises completed as specified and as directed by Engineer in charge. |
| 5 | M & L for rendering 5mm thick in CM (1:3) on concrete surface of ceiling, finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge. |
| 6 | M&L for Preparation of newly plaster surfaces of ceiling by hand held sander / long handle sander including cornices, pilasters etc and applying three coat of white washing with roller finish complete all as specified and as directed by Engineer-In-Charge. |
| 7 | M & L for rendering 15mm thick in CM (1:4) on fair faces of stone masonry/brick/concrete surfaces of wall, finish even and fair without using extra cement complete all as specified and as directed by Engineer -in-charge. |
| 8 | M & L Non skid coloured ceramic tiles 7-8mm thick area of each tiles exceeding 0.06 Sqm but not exceeding .11 Sqm, in floors etc. set and jointed in neat cement slurry mixed with water proofing liquid compound and pointed in white or coloured grouting chemical to match, over 15mm thick screed bed in CM 1:6. complete all all as specified and as directed by Engineer-in-charge. |
| 9 | M&L Glazed ceramic coloured designer tiles in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick plaster in cement mortar (1:3) complete all all as specified and as directed by Engineer-in-charge. |
| 10 | M&L Preparation of newly plastered surface of wall by hand held sander/ long handle snader including cornices, pilasters etc and applying with airless spray two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete as specified and as directed by Engineer in charge. |
| 11 | M&L for Preparing of old surfaces by complete removal of existing treatment, scraping down, washing, rubbing down and stopping of painted surface of walls & ceiling including roof projection / chajjas and by hand held sander / long handle sander including cornices, pilasters etc (Plastered or unplastered surfaces) and applying Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade on Two coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.9lit/10 sqm complete all as specified and as directed by Engineer-in-charge. |
| 12 | Demolition of cement concrete (un-reinforced) in any position not otherwise specifically provided complete all all as specified and as directed by Engineer-in-charge. |
| 13 | M&L for 40 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate mixed with liquid water proofing compound @ 3% of cement in bottom of sunken floors all as specified and as directed by Engineer-in-charge.Note: water proofing comound will be measured and paid saperatly. |
| 14 | Supply only of integral water proofing compound as per manufactures instruction complete all as specified and as directed by Engineer-in-charge. |
| 15 | M&L Cleaning vertical and horizontal surfaces of sunken slab using wire brushing followed by sanding with emery paper for loose materials/dust and applying two coats of epoxy resin component (Dr. Fixit DAMPGUARD or equivalent) solution/mix using nylon brush pouring Base part in appropriate container followed by the Hardner part and mix thoroughly to attain homogeneous smooth paste and dilute the mixed compound with water in ratio 1 part Base: 1 part Hardner: 1 part water by slow addition and mix thoroughly until a brushable consistency is obtained, first coat will be allowed to dry for 6 to 8 hrs before application of second/final coat) incl curing treated surface for 24 hrs complete incl applying evenly a coat of blown bitumen @ 1.5kg/sqm over entire treated surfaces incl spout holes complete all as specified as per manufacturer instructionall as specified and as directed by Engineer-in-charge. |
| 16 | M&L 15mm thick rendering in cement plaster 1:3 with WPC on bottom and side walls of sunken floor incl finishing even and smooth w/o using extra cement complete all all as specified and as directed by Engineer-in-charge. |
| 17 | M&L for filling PCC 1:5:10 type E-2 (40 mm graded stone aggr) as in sunken floor after applying appropriate treatment to side walls complete all all as specified and as directed by Engineer-in-charge. |
| 18 | Taking down PVC chowkats or frames with shutters (without taking off shutters from the frame) each area exc 1.5 sqm but n.exc 4.0 sqm of any description each, complete all as specified and directed by Engineer in charge. |
| 19 | S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed by Engineer-in-charge. |
| 20 | S&F factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel designed with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face incl particle board core complete all all as specified and as directed by Engineer-in-charge. |
| 21 | S&F100mm butt hinges,extruded aluminium alloy with galvanised mild steel hinge pin,anodised and fixed,type B-21. complete all all as specified and as directed by Engineer-in-charge. |
| 22 | S&F Extruded aluminium alloy handles 125mm long, fabricated type, anodised. complete all all as specified and as directed by Engineer-in-charge. |
| 23 | S&F Aluminium anodised barrel tower bolts, 150mm long, of extruded section. complete all all as specified and as directed by Engineer-in-charge. |
| 24 | S&F 250 mm long aluminium anodised sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium complete all all as specified and as directed by Engineer-in-charge. |
| 25 | S & F Vitreous China Squatting Pan ‘ORISSA’ Pattern, size 580X440 mm White, with , Integral Foot Rest, providing Joints between Flush Pipe and Socket of WC Pan (excluding Flushing Cistern and Flush Pipe), and connected Items, complete all all as specified and as directed by Engineer-in-charge. |
| 26 | S&F 10 litre capacity low level PVC flushing cistern (white), syphonic action type, with inlet, ball valve, float, handle, fixed with cast iron bracket (of suitable size) and providing 32 mm dia PVC flush pipe and making all necessary connections complete all all as specified and as directed by Engineer-in-charge. |
| 27 | S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe). complete all all as specified and as directed by Engineer-in-charge. |
| 28 | S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all all as specified and as directed by Engineer-in-charge. |
| 29 | S&F powder coated anodised aluminium alloy sections 3 tier track sliding windows series B of size 92mm x 31.75mm x 1.2mm and shutter section 18mm x 43mm x 1.30mm weight 0.547 kg/m Jindal or equivalent duly fitted with neoprene beading, glazing clips, tinted glass panes 4.80/5.0 mm nominal thickness, stainless steel wire cloth 0.36 mm dia and average width of aperture 1.4 mm, aluminium alloy handles etc including taking down old window in any size and make. complete all all as specified and as directed by Engineer-in-charge.Note : rate shall include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, handle etc all as specified and as directed by Engineer-in-charge. |
| 30 | S&F powder coated anodised aluminium fixed louvered ventilator frame of size 63.5 x 38.1 x 1.01 mm thick or equivalent section fixed in vertical position with aluminium vertical members and half portion to be provided with 4 mm thick pinhead glass and remaining portion to be louvered using 4 mm thick pinheaded glass and louvered portion covered with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm incl necessary channel frame work, including rubber gasket and aluminium beading including taking down old ventilator in any size complete all all as specified and as directed by Engineer-in-charge.Note : rates shall include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading etc all as specified and as directed by Engineer-in-charge. |
| 31 | Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and as directed by Engineer-in-charge |
| 32 | M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, incl 20 mm thick screed bed in CM 1:6 complete all all as specified and as directed by Engineer-in-charge. |
| 33 | Moulding to Granite(single or double) slab including rounding off edges for 20 mm thick slabs including grinding and polishing complete all all as specified and as directed by Engineer-in-charge. |
| 34 | S & F in repair under counter basin ovel size 595x420x200 complete including 32 mm bore s/s waste coupling , washers and s/s bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and directed by Engr-in-Charge. |
| 35 | S&F in repairs vitreous china urinals, flat back of size 465x355x265mm, Vitreous China urinals bowl type (back or corner wall type), complete including covering and fixing plugs, bedding urinals against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around back in cement, fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe white with grating and union for discharge pipe including connecting waste pipe complete all all as specified and as directed by Engineer-in-charge. |
| 36 | S&F in repair 600 X 450 mm bevelled edge miror of selected guality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with CP brass screws and cup washer complete all as specified and as directed by Engineer-in-charge. |
| 37 | S&F in repairs 2 in 1 wall maounted mixer (15 mm bore) with quater turn fittings and provision for overhead shower with 115 mm bend pipe and wall flange, cast copper alloy with capstan heads, fancy type chromium plated (robotic electroplating for everlasting lustrous shine) with 2 water volume adjustment knobs one both side to control the flow of temperature ,screwed down, screwed for iron pipe or for brass ferrule and fixed includng neccesary fittings complete for mixing hot and cold water for tap and shower complete all as specified and directed by Engr-in-charge. |
| 38 | S&F in repairs bib taps cast copper alloy chromium plated, fancy type, long body, concealed type with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule & fixed 15mm bore complete all all as specified and as directed by Engineer-in-charge. . |
| 39 | S & F in repair 15mm bore fancy type pillar taps, cast copper alloy, with long heads, chromium plated , screwed down high pressure, with or without lettered 'Hot or Cold ' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed by Engineer-in-charge. |
| 40 | S&F in repairs stop cock 15 mm bore cast copper fancy type chromium plated alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions complete as specified and as directed by Engineer-in-charge. |
| 41 | S&F in repair 125 mm Brass chromium plated shower rose with or without swivel joints, any size, including fixing to steel pipe or union, complete all all as specified and as directed by Engineer-in-charge. |
| 42 | S&F in repair Brass chromium plated Tublar towel rail 20mm dia D type 60 cm long between flanges complete all all as specified and as directed by Engineer-in-charge.. |
| 43 | S&F in repairs Soap Dish of any type (S/S) approximate size 160x160 fixed to plugs with chromium plated brass screws as selected complete all as specified and directed by Engineer-in-charge.. |
| 44 | S&F in repairs 600mm long PVC connection tubes 15mm dia bore Size with brass nuts. as selected all as specified and directed by Engineer-in-charge.. |
| 45 | S&F in repairs glass corner shelf 300 mm (with ABS Bracket 300x 600) as selected including removing existing shelf ,specified and directed by Eng-in-charge. |
| 46 | S & F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated braket guard and railing 60cm long complete all all as specified and as directed by Engineer-in-charge. |
| 47 | Supply and fix in repair 75 mm bore PVC (SWR) plain floor trap with CP grating complete all as specified and directed by the Engr-in-Charge. |
| 48 | S&F in repairs PVC(SWR) pipe 110 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, fixed to walls complete all all as specified and as directed by Engineer-in-charge. |
| 49 | S&F in repairs PVC(SWR) pipe 110 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, laid in trenches or in floors complete all all as specified and as directed by Engineer-in-charge.. |
| 50 | S&F in repairs PVC(SWR) pipe 75 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, fixed to walls complete all all as specified and as directed by Engineer-in-charge.. |
| 51 | S&F in repairs PVC(SWR) pipe 75 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, laid in trenches or in floors complete all all as specified and as directed by Engineer-in-charge.. |
| 52 | S&F 110mm PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and directed by Engineer-in-charge. |
| 53 | S&F 75mm PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and directed by Engineer-in-charge. |
| 54 | S&F in repairs PVC(SWR) bend any radius,110 mm dia.provided with access door complete all as specified and directed by Engineer-in-charge. |
| 55 | S&F in repairs PVC(SWR) bend any radius,75 mm dia.provided with access door complete all as specified and directed by Engineer-in-charge. |
| 56 | S&F in repairs PVC (SWR) junction single, (single T), equal or unequal 110mm bore provided with access door complete all as specified and directed by Engineer-in-charge. |
| 57 | S&F in repairs 110 mm dia PVC (SWR) vent cowl complete all as specified and directed by Engineer-in-charge. |
| 58 | S&F in repairs PVC (SWR) junction double, (double T), equal or unequal provided with access door complete all as specified and directed by Engineer-in-charge. |
| 59 | Taking down 25 mm or 32mm bore steel water tubing and connection from wall and floor complete all as per directed including cleaning for refixing or removal from site as in repairs. complete all all as specified and as directed by Engineer-in-charge. |
| 60 | Taking down 20 mm bore steel water tubing and connection from wall and floor complete all as per directed including cleaning for refixing or removal from site complete all all as specified and as directed by Engineer-in-charge. |
| 61 | S & F of 25mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fitings, connected joint with CPVC adhesive taflon tape in any requirment complete to walls and ceilings or laid in floorss including all connected brass CPVC fitting sand cutting grooves filled with CM (1:6) complete as specified and as directed by Engineer-in-charge. |
| 62 | S & F of 20mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fitings, connected joint with CPVC adhesive taflon tape in any requirment complete to walls and ceilings or laid in floors including all connected brass CPVC fitting sand cutting grooves filled with CM (1:6) complete as specified and as directed by Engineer-in-charge. |
| 63 | M&L 75 mm thick Cement concrete,1:3:6 type C-2(using 40 mm graded aggregate) as in plinth protection complete all all as specified and as directed by Engineer-in-charge. |
| 64 | M&L Forming Construction joint 30mm deep x 10mm wide filled with sealing compound Grade A complete all all as specified and as directed by Engineer-in-charge. |
| 65 | Dismantling water tanks and removing to store capacity exc 500 & n.exc 1000 ltrs complete all all as specified and as directed by Engineer-in-charge. |
| 66 | S&F 1000ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position with 20mm ball/float valve complete all all as specified and as directed by Engineer-in-charge. |
| 67 | Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sqm on plan and not exc 1.5m in depth and getting out in soft/loose soil, complete all all as specified and as directed by Engineer-in-charge. |
| 68 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all all as specified and as directed by Engineer-in-charge. |
| 69 | Removing excavated materials to a distance not exceeding 50 m and depositing at a level not exceeding 1.5 m from starting point complete all all as specified and as directed by Engineer-in-charge. |
| 70 | Demolition and breaking up sewage drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar (Internal dia of pipe in 200 mm) complete all as specified and as directed by the Engineer-in-Charge. |
| 71 | S&F DWCPE (SN8) pipes, nominal dia 200 mm laid in trenches for sewer network, fixed and jointed with integral socket or coupler and EPDM sealing ring (depending on pipe ends) as per manufacturer instructions complete all as specified and as directed by Engr-in-Charge |
| 72 | M&L for cement concrete to bedding 200 mm bore drain pipes and haunching against the sides of pipes after they are laid in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates) laid to falls including packing under, and tested, complete all all as specified and as directed by Engineer-in-charge.NOTE :- Pipe shall be measured and paid separately).as in repairs. |
| 73 | Demolition for reinforcement cement concrete in cover slab of manholes complete all all as specified and as directed by Engineer-in-charge. |
| 74 | M&L for precast RCC 1:2:4 type B1 using 20mm graded stone aggregate in cover slabs including necessary form work etc for manholes covers set in CM 1:4 (reinforcement measured seperately) complete as specified and as directed by Engineer-in-charge. |
| 75 | M&L for TMT bars 6 to 8mm dia and over cut to length bent to shape required including bending and binding with and including MS wire annealed not less than 0.9mm dia complete all all as specified and as directed by Engineer-in-charge. |
| 76 | Demolition of brick/stone masonary built in CM 1:6 as in manholes complete all as specified and as directed by Engineer in charge. |
| 77 | M&L for block masonary 1:3:6 type C1(using 20mm graded aggregate) built in CM 1:6, as in manholes complete all as specified and as directed by Engineer-in-charge. |
| 78 | M & L for rendering 15mm thick in CM (1:4) on fair faces of stone masonry/brick/concrete surfaces of manhole, finished even and fair without using extra cement complete all as specified and as directed by Engineer -in-charge. |
| 79 | M&L Hard core of guage exc 63mm thick (broken bricks) but n exc 100mm, deposited spread and levelled in layers n exc 15cm thick watered and rammed to a true surface of ground floor etc. complete all all as specified and as directed by Engineer-in-charge. |
| 80 | M&L Hard core of guage n.exc 63mm thick(broken stone or boulder) deposited spread and levelled in layers n exc 15cm thick watered and rammed to a true surfac of ground floor etc. complete all all as specified and as directed by Engineer-in-charge. |
| 81 | M&L for 40 mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregates) as in sub base, flooring , mass concrete etc complete all all as specified and as directed by Engineer-in-charge. |
| 82 | M&L for old size brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 as in repairs. complete all all as specified and as directed by Engineer-in-charge. |
| 83 | Demolition of cement concrete (reinforced) as in roof, lintel , shelf , staircase landing, chajjas and similar suspeded work complete all as specified and as directed by Engineer in charge. |
| 84 | M&L for RCC (nominal mix) 1:2:4 type B1 (20mm aggregate) as in beam, cantilevers, bressummers, lintels over 1.5 span complete all as specified and directed by Engineer-in-charge. |
| 85 | M&L for formwork to side and soffits of floor or roof beams, beam haunchings, girders, bresssummers, lintels, catilevers, shelves including sup-ports , overhangs, etc. also splays between floors and beams, etc complete all as specified and directed by Engineer-in-charge. |
| 86 | S&F Mild steel bars (TMT bars) 10mm dia & over as in lintel, cut to length, bent to shape required, including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-charge. |
| 87 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all all as specified and as directed by Engineer-in-charge. |
| 88 | Removing the plant/growth of any description size, any location of external surfaces of walls shafts by cutting & remvoing the roots completely spraying the suitable chemical (each plant 100 ML) in the removed portion to avoid re-growth & making good damaged portion to match the existing surfaces by PCC type B0 (1:2:4) 12.5 mm graded aggregate complete all as directed by Engr In Charge (Chemical :- Gramzone/Roundup or equavalent suitable chemical to remove/destroy the plants/roots) |
| 89 | Removal of all loose/unsound/bad/damaged concrete or plaster existing RCC structure of slab/beams/walls/chajja by using chesel/hammar .Cut and remove unsound reinforcement bars, wires etc without damaging the sound reinforcement . clean loose rust from bars manually with brush . fixing new supplymentary bars if required,either by tying it with existing bars or by welding on it. Applying eppoxy bonding agent and making good with polymer modified plaster/micro concrete as required thickness over a coat of rust removing alkaline primer and match the finishing to the existing surface in ground floor including formwork complete all all as specified and as directed by Engineer-in-charge. |
| 90 | Complete removal of existing roof treatment, removing rubbish off the premises, cleanning the surface and preparing to receive new roof treatment and applying roof treatment as under:- (a) Applying coat of bituminios primer @ 0.40 litre/ Sqm on prepared surfaces and allow to dry(the primer and the membrane to be used shall be of same manufacturer, (b) Supply and laying of minimum 3 mm thick APP modified polymeric membrane weighting not less than 3 KG/ Sqm black finish reinforcement with non woven polyster matt with help of torching with proplane or abutance gas using torch with minimum 75 mm side overlap and 100 mm end overlap. (c) two coat of approved aluminium paint over membrane complete. (d) all overlaps and joints shall be sealed as per manufacturers instruction complete all all as specified and as directed by Engineer-in-charge. |
| 91 | Roughening surfaces of old concrete surfaces by picking, sweeping clean and washing down with water to remove dust, etc incl brushing neat cement slurry with 3.0 kg of cement per sq metre complete all all as specified and as directed by Engineer-in-charge. |
| 92 | M&L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all all as specified and as directed by Engineer-in-charge. |
| 93 | M&L for Rendering 10 mm thick in CM(1:3) with using water proofing compound on fair faces of brick work/ Fasia and roof surface finished even and smooth without using extra cement complete all all as specified and as directed by Engineer-in-charge. |
| 94 | M&L 25mm thick PCC 1:2:4, type B0 (using 12.5mm size stone aggregate) as levelling course complete all all as specified and as directed by Engineer-in-charge. |
| 95 | S&F tube GI medium grade 20 mm dia with all fittings laid in trenches complete as specified and as directed by Engineer-in-charge. |
| 96 | S&F tube GI medium grade 25 mm dia with all fittings laid in trenches complete as specified and as directed by Engineer-in-charge. |
| 97 | Supply and fix Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 20 mm complete as specified and as directed by Engineer-in-charge. |
| 98 | Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all all as specified and as directed by Engineer-in-charge. |
| 99 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all all as specified and as directed by Engineer-in-charge. |
| 100 | Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all all as specified and as directed by Engineer-in-charge. |
| 101 | M & L for Point wiring One light point controlled by one, one way switch 5 Amps using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster completeall as specified and as directed by Engineer-in-charge. |
| 102 | Description all as per item No 101 here in before but using One exhaust fan point controlled by one , one way switch 5 Amps and regulator ( New Provn) |
| 103 | Description all as per item No 101 here in before but using 3 point 5 Amps switch socket outlet point controlled by one switch on the same board |
| 104 | Description all as per item No 101 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dollyall as specified and as directed by Engineer-in-charge. (power point) |
| 105 | Description all as per item No 101 here in before but using 4 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 15 amps switch socket cobmination point including necessary running of 4 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dollyall as specified and as directed by Engineer-in-charge. (power point For geyser )(New provision) |
| 106 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and,cutting chases for concealed water,tubing or concealed conduit wiring,,etc., and making good, cutting not,exc 10 cm girth ®(stone massonary )complete all all as specified and as directed by Engineer-in-charge. |
| 107 | S & F for modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all all as specified and as directed by Engineer-in-charge. |
| 108 | S & F for modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all all as specified and as directed by Engineer-in-charge. |
| 109 | S & F for modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all all as specified and as directed by Engineer-in-charge. |
| 110 | S & F for modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all all as specified and as directed by Engineer-in-charge. |
| 111 | S & F for metal clad box suitable for 230 volt 50 hz AC supply three pin with MCB sp 20/32 Amps including removal of old unserviceable one complete all all as specified and as directed by Engineer-in-charge. |
| 112 | S & F for ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all all as specified and as directed by Engineer-in-charge. |
| 113 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all all as specified and as directed by Engineer-in-charge. Note:- Two runs of 6.0 sqmm cable,one run of 6.0 sqmm cable and one run of PVC conduit will be measured as one unit |
| 114 | S & F for sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all all as specified and as directed by Engineer-in-charge. |
| 115 | S & F for MCB single pole and neutral rated capacity 40 to 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all all as specified and as directed by Engineer-in-charge. |
| 116 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all all as specified and as directed by Engineer-in-charge. |
| 117 | S & F for LED tube light fitting 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all all as specified and as directed by Engineer-in-charge. |
| 118 | S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all all as specified and as directed by Engineer-in-charge. |
| 119 | Supply and fix electic water heater , storage type steel body with copper inner tank and heating element upto 2 kw capacity 25 litre BEE 5 star rated complete with ass accessories such as safety valve , thermostate ,nrv, connection piece etc all as specified and as directed by Engineer-in-charge. (New provision) |
| 120 | S & F for energy efficient exhaust fan of 300 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and as directed by Engineer-in-charge. (Note : Cost of suitable opening in wall for fixing exhaust fan is deemed to be included in overall rate quoted).(New provision) |
| 121 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts with pre wired and necessary mounting arrangements and provision of 1.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail