| 1 | Wiring for Light point/Fan point/Exhaust fan/Bell point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable, (Havells/Polycab/Anchor/Apar/ Grandlay/ Eq Make) in surface/recessed Conduits laid in slabs with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified/Schneider/ Havells/ Legrand/Anchor roma plus/ ABB/ Eq.Make & along with 2.5 Sqmm (P+N+E) Circuit Wire of same make as mentinoned above & items shall be approved before execution of work by SDO. |
| 2 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/Anchor/Apar/ Grandlay/ Eq. Make to be approved by EIC) |
| 3 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified /Legran/Anchor roma plus/Schneider/ABB/Eq Make & shall be approved before execution of work by SDO. |
| 4 | Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/ Recessed Conduit (Havells/ Polycab/ Anchor/ Grandlay/ Apar/ Eq. Make) |
| 5 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Havells/Legrand/ Anchor roma plus/Schneider/ABB/Eq.Make & shall be approved before execution of work. |
| 6 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Polycab/Anchor/ Eq.Make) & shall be approved before execution of work |
| 7 | 2x10 sq.mm+ 1x6 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards. |
| 8 | 2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/ Sub main in One run from Main Panel to Distribution Boards. |
| 9 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire for AC Sub-main |
| 10 | Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB DB Complete with connections. (L&T/ Siemens/ Legrand/ Havells/ABB/Eq. Make) |
| 11 | Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens /Legrand/Havells/ABB/Eq Make) |
| 12 | 40Amp. |
| 13 | 63Amp. |
| 14 | Supplying and Fixing of MCB 8 way (4 + 24), horizontal typed , sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ Schneider/ABB/Eq Make) |
| 15 | Supply/Installation/Testing and Commissioning of 18W + LED Conceal (Commerical Type) light luminary fitting round shape with minimum system lumen efficacy of 120 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Havell's/Wipro/Halonix/Eq Make as approved by SDO. |
| 16 | Providing & Fixing of IK08 IP-66 protected high power LED 50 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Havells/Crompton/Philips/Halonix/Eq.Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department. |
| 17 | Supply/Installation/Testing and Commissioning of 225-250mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB of Following Sizes including connection etc USHA/Havells/Crompton/Eq. Make.(Min 1-Star) |
| 18 | Supply/Laying/Connecting and Commissioning of 70 sq.mm 2-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/Polycab/Eq. Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench .(Material to be approved before execution) |
| 19 | Supply/Installation/Testing and Commissioning of CPRI Approved (IS/IEC:61439) Main Controlling Panel,fabricated out of heavy gauge sheet steel ,dully Painted with powder coated paint ,dust protected ,earth terminal fitted on epoxy cleats, volt meter & Ammeters with selector switch & CT Coil of required ratio with all necessary connections & inner wiring of panel on both heating and lighting circuits. The switches are connected with bus bars inside panel & manufacturer CPRI Certified.The switch are adjustable type made of Havells/ L&T/ABB/Legrand/Siemens Make and change over switch should be of Havells/ L&T/Legrand/ Schneider Make.(1) Normal Incomer:a) 125 Amp-2-Pole ,25kA C-CURVE MCCB with extended terminals Havells/L&T/Legrand/Schneider/ eq. make as approved=01 No. b) 200 Amps TPN Al. Bus Bar Set = 01 Set,Digital Voltmeter ,Ammeter ,C.T Coils with Selector Switch & Phase indicator Set.Outgoing:(1) Normal outgoing for Heating/AC/Lighting/Inverter etc load(a) 40-Amp DP MCB = 02 No. as per site requirement)(b) 63-Amp DP MCB = 02 No. as per site requirement)(c) 32 Amp DP MCB = 04 No. as per site requirement) for AC's |
| 20 | ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER Rod EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value .Supplying, Installation and Testing of 75 mm copper Pipe Filled with Crystallineconductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 2OMM Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through DWC High Density Poly ethylene Pipe having Corrugation complete job |
| 21 | Supply/Installation/Testing & Commissioning of 10W LED Bed Light of Havells/Wipro/Halonix/ Eq.Make as duly fitted on walls including making of necessary Connections & sample shall be approved by EIC. |
| 22 | Providing ,fabricating and fixing GI |pipe 40 mm dia class A 2.5Mtrs long with suitable brackets for holding 30W flood light and fixing the same in concrete (1:2:4) surya/Tata/jindal/Eq.make |
| 23 | Supply/Installation/Testing and Commissioning of IK08 IP-66 protected high power 30 Watt.LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 Im/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @›=300 V AC and Auto resetting Safety Power Factor >0.95, THD(1) <10%, driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10K external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department. connection wires Philips/Wipro/Havells/Halonix/Eq. make. |
| 24 | Supply/ installation/testing and commissioning of CPRI Approved (IS/IEC:61439) panel Outdoor type , Mian Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices(1) Normal Incoming100 Amp DP MCB 25 kA with thermo magnetic adjustable based of Legrand/ Siemens/ ABB /Schinder /L&T/Havells make = 1 no 160 Amp P&N Bus bar Al Strips = 1 SetVolt meter =1 no, Ammeter = 1 no ,phase indicators =1setOutgoing:1) 40 Amp DP = 2 No. for Lighting Circuits Legrand/ Siemens/ ABB /Schinder /L&T/Havells make |
| 25 | Supply/Laying/Connecting and Commissioning of 16 sq.mm 2-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/Polycab/Eq. Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench .(Material to be approved before execution) |
| 26 | Supply Installation Testing & Commissioning of 4 Star rating 1.5 TON inverter type split Air Conditioning system suntable for operation on AC supply single phase 220 V The indoor unit fitted on wall by employing suntable clamps and the outdoor unit fitted on the wall by using suitable angle iron stand fitted with nuts/bolts outside the room to avoid noise, including standard length of suitable size copper tubing covered with nitrilic foam, topping up with refrigerant for additional length of piping if required, PVC flexible drain pipe, suitable capacity 3 core sheathed/ pvc insulated coper cable and a battery operated wireless remote unit. the job also includes repairs to walls wherever the same are cut and the AMC of AC for a period of one and a half year from date of successful commissioning. ‹O-General make) including cost of 5 KVA Digital Auto control VOLTAGE Stabilizer for ACs of Approved brand for smooth functioning/ constant voltage supply having etc Input voltage= 90-220 volts & output voltage=220 volt & stand Copper piping ete & all other allied accessories. installation charges.GST, income tax, Carnage ete Complete job The job includes CMC (reckoned from date of successful commissioning) for a period of Two years. |
| 27 | Supply & fixing of Modular AC box with 32 AMP Single pole MCB of Havells/Legrand/Schneider/L&T/ eq. make to be approved by EIC |
| 28 | Supply and fixing of wooden channel/ casing made from Kashmiri budloowood having 2.6\\"-3\\" width suitable for carrying out wiring for different circuits. |
| 29 | Supply ,installation ,testing , &commissioning of 20 KVA 1 -Phase SERVO controlled VOLTAGE Stabilizer of Approved brand with following SPECIFICATIONS :(1). INPUT VOLTAGE: 90 Volt -220 Volts (2). OUT PUT VOLTAGE : 230Volts+ 1% (3).Winding Material Insulation : 99.97% PURE COPPER WOUND FIBER GLASS (4). IN DOOR TYPE(5). COOLING :OIL 1S 335(6).MICRO CONTROLLED TRUE RMS Based LCD display (7). Protections are Over Load COPPER wound of /Chinar / Electric Field /Alba /AE /Cosco etc ISI/1SO certified for smooth functioning/ constant voltage supply having Technical Specifications : Input voltage= 90-220 volts & output voltage=230 volts+ - 1%Buck Boost Transformer Copper wound 99.9% ,OIL Immersed COOLING OIL ,High cut/Low Cut /Time delay / Over Cut through Micro Control and Spike Protection including ,Carriages ,installation charges , testing & taxes complete job alongwith servo bypass switch of adequate rating. |
| 30 | Supply/Installation/Testing and Commissioning of 63 Amp Two Pole manual bypass changeover switch of Havells / Siemens/ ABB /Schinder /L&T/Eq make to be approved by EIC Please Enable Macros to View BoQ information |