Public Administrative Department Local Bodies Closing in 0 days TDR #55538562

Tender For Construction Of Primary Health Centre (Phc) At Jogta, Block-Baghmara, District - Dhanbad (Jharkhand)

Issued by Local Bodies · Baghmara, Jharkhand
Tender Value
1.42 Crore
Estimated cost
Bid Submission
23 May 2026
0 days left
EMD
2.86 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Baghmara → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Primary Health Centre (Phc) At Jogta, Block-Baghmara, District - Dhanbad (Jharkhand)

BOQ

Name of Work:- Construction of Primary Health Centre (PHC) at JOGTA, Block-Baghmara, District - Dhanbad (Jharkhand)
Sl. No. Item Description
1Earth Work in excavation in Foundation Trenches in Ordinary soil (vide classification of soil item -B) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I
2Extra for earth work in hard soil as per specification & direction of engineer in charge (Vide classification of soil item B)
3Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compactedvolume).
4Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer In charge (Mode of measurementcompacted volume)
5Providing and laying in position cement concete of soecified grade excluding the cost of centering and shuttering - All work up tp plinth level 1:4:8 (1 cement :4 coarse sand (Zone -III) :8 graded stoneaggregrate 40 mm normial size)
6R C C WORK Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
7Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
8Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chayas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
9Providing Tor steel reinforcement of 8mm. dia rods as per approved design and drawing -do- -do- TMT Fe 500 (Only valid for sAIL & TATA Stee 20%
10Providing Tor steel reinforcement of 10mm. Dia. bars asper approved design and drawing -do- -do - 15%
11Providing Tor steel reinforcement of 12mm. To 20 Dia. bars as per approved design and drawing -do- -do- 65%
12Centering and shutteing including struting, propping etc and removal of form for Foundations, footings, bases for columns, etc for mass concrete
13Centering and shutteing including struting, propping etcand removal of form for Suspended floors, roof , landings , balconies and access platform
14Centering and shutteing including struting, propping etcand removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
15Centering and shutteing including struting, propping etcand removal of form for Columns, Pillars, Piers, abutments, Posts and struts
16Centering and shutteing including struting, propping etc and removal of form for Vertical and horizontal fins individuaaly or forming box louvers band, facies and eaves boards
17Centering and shutteing including struting, propping etc and removal of form for Edges of slab and breaks in floors and walls Under 20 cm Wide First floor
18Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). uspended floors, roofs, landing, beams and balconies (Plan area to be measured) All floors slabs:( floor to floor HI 3.6 m)
19providing designation 75 B brickwork in C M (’1 : 6 ) in foundation and Plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing. taxes and royalty all complete as per building specification and direction of Eñ.
20Providing Designation 100A B/W with Fly Ash Lime Brick (FALB) conforming to IS 12894-1990 (9\\"x4.5\\"x3”) in cement mortar (1:6) in Superstructure with clean coarse sand of F.M. 2 to 2.5 including 10mm thick mortar joints,cost of screening, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of EJ.
21Providing designation 112 mm thick reinforced designation100 A brick work vuith fly ash lime brick (FLAG)confirming to IS 12894-1990 (9\\"x4'5\\"x3\\" ) in C.M. ( 1 . 4 ) insuperstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specificationand direction of EDI
22Extra for providing & placing in position 2 no 6mm dia ms bar every 3rd corse of half brick masonary
23Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxesroyalty all complete as per building specification and direction of E/I.
24Supplying fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both side decorative veneered with black board core bended with high quality phenol formal clehydes synihetic resin of standard make with Aluminium fittings :such as hinges, tower bolts, hendle, cleats and sand blocks and taxes all conrplete as pe building specrfication and direction of E/I.
25Supplying fihing and fixing 35mm thick soltd core typedecorative double leaf flush door sltutter with both side decorative veneered with black board core bended with high quality phenol formal clehydes synihetic resin of standard make with Aluminium fittings :such as hinges, tower bolts, hendle, cleats and sand blocks and taxes all conrplete as pe building specrfication and direction of E/I.
26Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat onunexposed surface etc. complete :
27Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
28Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
29Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
30Providing and fixing double action hydraulic floor spring ofapproved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
31Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
32Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness,incIuding hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
33Supplying,frtting and fixing M.S. grill made of 20x6cmmM.S. flat as per approved design and drawing, properly fabrlcated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/1
34Supplying fitting and fixing glass panes including supplying putty, beads and nails after taking out old and broken glass panes and disposal of debris all complete as per building specification and direction of E/1.( 5.5 mm thick Glass )
35providing and laying, Doublecharge vitrified floor tiles indifferent sizes (thickness to be specified by Ihe manufacturer) with water absorption less than 0.08% and conforming to IS 15622/ISO 13009 of approved make in all cotours and shades, laid on 20mm thick cement mortar 1 4 (1 cement:4 coarse sand) jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of tile 600x600 mm
36Providing and fixing granite 18 mm thick gang saw cut,mirror polished, premoulded and prepolished, machine cut for flooring, kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete atall levels.
37Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement :4 coarse sand) laid and jointed with œment slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishingetc. all complete as specified and as directed by the Engineer-in-Charge
38Providing edge moulding to 18 mm thick marble/granitestone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
39Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc.complete.
40Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineers in-charge and finished smooth.Granite Stone of approved shade
41Providing and laying 1st quality Ceramic glazed wall tiles thickness to be specified by the manufacturer) in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing polishing and cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
42Providing and laying 25mm. thick kotah stone slab flooring of approved size, texture and colour over 19 mm thick base of lime morter (1:I:1) ( Lime putty : surkhi: coarse sand ) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to granolithic finish with approved quailty of carborandum stone including cost of curring, taxes and royalty all complete as per building specification direction of E/I. 600x600mm Size.
43Providing and laying 25mm. thick kotah stone riser of steps, skirting and pillers of approved size, texture and colour over 12 mm thick cement morter (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to granolithic finish with approved quailty of carborandum stone including cost of curring, taxes and royalty all complete as per building specification direction of E/I. 600x600mm Size.
44Providing and laying Ceramic glazed floor tiles of size300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
45Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design '
46Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand 4 graded stone aggregate of 20 mm nominal size) overP.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
47Water proofrng for Old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory a designed ready to use, acrylic modified flexible material applied with brush, roller or spray waterproofi ng coating as per manufacturer specification-With following steps :-(a)surface preparation :-Provrding and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt.Ltd.(c) :2nd Coat:- To apply the 2nd coat of two componentacrylic modified,ready to-use, flexible cementitious material right angle to the '1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/ Sqmt/coat. For the purpose of measurement the entire treated surface will be measured.\\" Alter three days of drying the 2nd coal , the rain water outles to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectificationlo be done as per satisfation of E/c.(e)Groove of PCC surface should be filled withPolysulphide Sealant (Paid Separately) Brand - Sika India Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc
48Covering of treated surface wrth PCC :- Providing 25 mm thick Cement Concrete M20 (1:1.5:3) raintaining slope in alternate 2 mlx 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and clcaned sand of F M 2 5 io 3 including screening,shuttering,and mixing cerite nt c0ncrete in mixer with admixture of integral water proofing and placing rn position,strikirrg cLrring,t-a]glgnd royality all complete as per buildirrg specifictionJand direction of E/I.Panels that has been left should be casteci nextday.-lhere should be 6 mm gap between Panels.Brando Sika *Plastocrate pIus,MYK proof WP10, Fosroc- Conplast X421ic , Dr Frx,t Prdiproof LWr
49Provrding and filling of Groove beMeen 25 mm PCC Panels with Polyshlphide Sealant (Poring Grade)as per drawings and technical specifications and dii-ection of E in Charge (with 1B% GST).Brand:-Sika- Polysulphide, Fosroc-I-hioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivallent
50Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
51Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
52Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete
53Providing 12mm thick cement plaster (1:6) with cleancoarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
54Finishing walls with Acrylic Smooth exterior paint of required shade,New work (Two or more coat applied @1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
55Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and m anufacture, including applying additional coats wherever required, to achieve even shade and colour.
56Providing and fixing aluminium work for doors, windows,ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately):
57For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
58Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse send : 6 graded stone aggregate 20 mm nominal size ) over 75 mm thick bed of dry brick ballast 40 mm nominal size ,wall rammed and consolidated and grouted with fine sand including necessary excavation, levelling & dressing & finishing the top smooth.
59Providing 150mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
60Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners.Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
61CARRAIGE OF MATERIALS Sand Lead = (19P + 1 UK) = 20km
62Stone Chips Lead = (25P ) = 25km
63Bricks Lead = (9P + 1 K) = 10km
64Cement +steel Lead = (15P ) = 15km
65SEPTIC TANK, Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling, ramming the foundation trenches, removing roots of trees shurbs all complete as per approved design building specification and direction of E/I.
66Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B)
67Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compactedvolume)
68Providing designation 75Bwork in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.m. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials ranking out joints to 15mm depth, curing taxes and royalty all complete as per building specification and direction ofE/I.
69Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
70Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
71Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size).
72Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
73Providing TMT steel reinforcement above 16mm to 36mm dia bars as per approved design and drawing excluding carriage of M.S. roads (Straight or in coils) to work site, cutting, bending end binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I. 10mm dia
7412mm dia
75Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification &direction of E/I
76Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water,scaffolding taxes and royalty all complete as perbuilding specification and direction of E/I.
77Providing 1.5mm cement punning including curing,carriage of water with all leads and lifts as per building specification and direction of E/I.
78Carriage of Materials- Bricks Lead = (9P + 1 K) = 10km
79Sand lead = 20 km
80Stone chips lead = 20 km
81cement+Tmt lead = 10 km
82ELECTRICAL WORK Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required.Group C
83Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
84Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 No 4 sq. mm FR PVC insulated copper conductor single core cablefor loop earthing as required.
85CIRCUIT/ SUBMAIN WIRING Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required2x1.5 sq mm + 1x1.5 sq mm earth wire
862x2.5 sq mm + 1x2.5 sq mm earth wire (1.7.2)
874x2.5 sq mm + 2x2.5 sq mm earth wire (1.7.8)
884x10 sq mm + 2x6 sq mm earth wire. (1.7.11)
89Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/PVC conduit as required.
90Supplying and fixing of following sizes of PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm dia
9125 mm dia
92Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excludingmodular plate etc. as required. 5/6 amps one way switch
9315/16 amp one way switch
945/6 amp 3 pin socket outlet
955/16 amp 6 pin socket outlet
96TV anteena Socket Outlet
97Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excludingmodular plate etc. as required.
98Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
99(Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (78mm x 78mm x 45mm) - For Telephone & TV outlet.
1004/5 Module (78mm x140mm x 50mm)
1016 Module (78mmX205mmx50mm)
102Supplying and fixing 2 pin 5 Amp Ceiling rose on the existing junction box/ wooden block including connection etc as required.
103Supplying and fixing brass batten/ angle holder including connection etc. as required.
104Supplying and fixing Ding dong sound call bell single phase, 230 volts, complete as required.
105Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, etc. as required.
106Installation of exhaust fan up 450 mm sweep in the existing opening including making the hole to suit the size of above the fan, making good the damage, connection, testing, commissioning etc. as
107Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (JSR-2.18)
108Supplying and fixing following ways, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 Way (4+24), Double Door Horizontal Type
109Supplying and fixing 6 Amp to 32 Amp rating 240 volts, 10 KA \\"C\\" Curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc.,as required. 6 / 32 Amp Single Pole
11040 Amp TPN
111Supplying and fixing Single pole blanking plate in the existing MCB DB complete etc. as required.
112Supplying and fixing of following rating double pole ( Single pole & neutral), 240 volts, resudual current circuit breaker (RCCB), having a sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc as required. 40 Amps (2.16.2)
113Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.
114Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
115Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
116Supply of XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto andincluding 1100 volts. (conforming to IS-7098. (Part-I).4 core, 16 sq.mm.
117Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existingsurface/ recessed Steel/ PVC conduit as required.1 run of cable
118Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trenchetc as required.Upto 35 sq. mm
119Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired.4 core, 16 sq.mm.
120S.I.T.C of following rating reccess/ surface mounted LED round/ square shape down light luminarie with pressure die cast housing for single phase Supply voltage. Luminarie shall be confirm to IS: 10322 part- 5/ Section- 2 or IEC: 62722 with all neccessary accessories as required. 18 /20 W LED Round Down Light (Surface) (JSR-9.3.4)
121Bulk Head fitting with 9/10Watt LED.
122S.I.T.C of following rating surface mounted LED Tube Lighting Fitting Suitable for 230V 50 Hz, Single Phase Supply etc. complete as required. 10/12 W LED Tube Light
12320/22 W LED Tube Light (JSR-9.5.2)
124SITC of 300 mm (12\\") Exhaust fan (Metal body) suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required. Make :- Usha/Crompton / Havells .
1251200 mm ( 48\\") BLDC 5 Star rating 32W Ceiling Fan
126PLUMBING AND SANITARY WORK Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. Of parry Hindustan or any other I.S.S. Approved make with 100mm H.C.I. 'P' trap 15liters C.I. Pull and let go flushing cistern of names or other I.S.S. Equipment make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/ P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pert of vitreous white glazed earthenwere were footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I.(A) 580 mm. long(a) with 10lit low Level PVC Cistern
127Supplying fitting and fixing 40mm high vitreous white glazed earthen E.W.C. With 'P' trap of parry hindustan or any other approved I.S.S. Make including supplying and fixing 15 litres C.I. Mosquito proof low down flushing cistern of approved make with complete fittings With C.I. handle and R.S. or bracket with telescope flush pipe with brass coupling and plumbers joints spindle stop cock of approved uality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved pain over a coat of red oxide priming all complete as per specification and direction of E/I.(b) With 10 ltr low level PVC cistern
128Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps
129Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I.(a) glass shelf with C.P. Brass rail.(i) 600X125mm glass shelf complete
130Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms
131Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved qualityand colour, weighing not less than 105 gms.
132Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms.
133Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore
134Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
135Providing and fixing toilet paper holder : C.P. brass
136SUBHEAD-II(A): INTERNAL DRAINAGE INSTALLATIONS Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 75 mm diameter metre
137110 mm diameter
138Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 110 mm.
139Single tee with door110x110x110 mm
140Bend 87.5°110 mm bend
141Shoe (Plain)110 mm Shoe
142Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length,including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.75 mm
143110 mm
144SUBHEAD-III(A): WATER SUPPLY INSTALLATIONS Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.20 mm nominal dia Pipes
14525 mm nominal dia Pipes
14632 mm nominal dia Pipes
14740 mm nominal dia Pipes
14850 mm nominal dia Pipes
149Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clampsat 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per directionof Engineer in Charge.15 mm nominal Outer dia Pipes
15020 mm nominal Outer dia Pipes
15125 mm nominal Outer dia Pipes
15232 mm nominal Outer dia Pipes
153Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design.
154Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
155Providing and fixing G.I. pipes complete with G.I. Fittings including trenching and refilling etc.External Work {25mm nominal nominal bore}
15632mm nominal nominal bore
15740mm nominal nominal bore
15850mm nominal nominal bore
15965 mm nominal nominal bore
160Providing & Fixing of Garden hydrant outlet consisting 1 No. 25mm dia. Ball valve,( Brass) for connecting rubber hose, pipes & fittings.
161Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) 25 mm dia, nominal bore
16250mm nominal bore
16365mm nominal bore
164Constmcting masonry Chamber 60x45x50 cm,inside with 75 class designation brick work in cement mortar 1:5 (1 cement:5 fine sand) for water meter complete with C.I. Doble flap surface box 400x200x200mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size) necessary excavation foundation concret 1:5:10 (1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design.With F.P.S. bricks
165Painting GI pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality {50 mm dia, nominal bore}
16665 mm dia, nominal bore
16780 mm dia, nominal bore
168Providing and fixing G.I. union in G.I. pipe including cutting andthreading the pipe and making long screws etc. complete. 32 mm dia, nominal bore
16940 mm dia, nominal bore
17050 mm dia, nominal bore
17165 mm dia, nominal bore
172Providing & fixing in position precast RCC manhole cover and frame of reqd. shape and approved quality.EHD - 35,Circular shape 560 internal dia.
173Constmcting masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard designWith common burnt clay F.P.S.(non modular) bricks of class designation 7.5
174Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately):50 mm dia
175Providing and fixing square mouth SW gully trap grade ’A' complete Cl grating brick masonry chamber with bricks of class designation 75 and water tight Cl cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. (COVER MIN. 4.5 KG & FRAME MIN.2.7 KG )150x100mm size P type With FPS bricks
176Providing and laying non-pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.150 mm dia RCC pipe
177Providing and laying in position cement concrete of grade excluding the cost of centering and shuttering - all work up to plinth level {1:5:10} (1 cement : 5 coame sand : 10 graded ston aggregate 40 mm nominal size)
178Deep Boring (200x150 mm dia ) Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well asfule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.(a) From 0.00 M to 50.00 M below G.L.
179(b) From 51.0 M to100.00 M
180(c) From101.0 M to125.00 M
181Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia
182Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineerin-charge
183Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of 200 mm dia
184Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete .200 mm clamp
185Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable forworking on 415 + 10, 3HP, 50 Hz, AC supply with cable guard thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/ double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages1.5 HP
186Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes , all complete job as per direction of E/I.
187Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX /HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I.
188Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(b) 32 mm nominal outer dia Pipes
189Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item –B) and disposal of excavated earth as obtained to a distance up to 50 M. Trenches , removing roots of trees , shrubs all complete as per approved design, Building specification and direction of E/I.
190Providing coarse clean sand filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm. Thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
191Providing designation 75 B one brick on edge soling joints filled with local sand including cost of Watering, taxes, royalty, all complete as per building specification and direction of E/I.
192Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
193Earth work in filling in foundation trenches and plinth in layers not exceeding 150mm. Thick well watered, rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 Mtr . and lift of 1.5 Mtr. All complete as per building specification and direction of E/I.
194CARRAIGE OF MATERIALS Sand Lead = (19P + 1 UK) = 20km
195Stone Chips Lead = (25P ) = 25km
196Bricks Lead = (9P + 1 K) = 10km
197SILENT TYPE D.G SET OF CAPACITY 15 KVF THREE PHASE WITH AMF PANEL IS/IEC -60034-1 IS:1460 IS:13018 (JESOR22){M-889}
198Add Sign Board and Photograph
199Goods & Service Tax (G.S.T.) -
200Labour Cess - Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 55538562
AUTHORITY Local Bodies
TENDER VALUE 1.42 Crore
LAST DATE 23-05-2026
Authority
Authority Name Zilla Parishad
Work Description Tender for Construction Of Primary Health Centre (Phc) At Jogta, Block-Baghmara, District - Dhanbad (Jharkhand)
Basic Detail
Tender No 26/2025-26/DE/ZPDH/DHANBAD/2nd Call
Bidding Type Tender
Location
City Baghmara
State Jharkhand
Key Dates
Publish Date 16 May 2026
Submission Date 23 May 2026
Open Date 25 May 2026
Finance
Tender Value 1.42 Crore
Tender Fee 10000
EMD 2.86 Lakhs
Exemption Not Available
Document List
35f35c18-e5f6-4648-959e-d6f885d09724.html
BOQ_154144.xls
Tendernotice_1 (9).pdf
Tendernotice_2 (3).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
May 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

35f35c18-e5f6-4648-959e-d6f885d09724.html

xls

BOQ_154144.xls

pdf

Tendernotice_1 (9).pdf

pdf

Tendernotice_2 (3).pdf

Disclaimer