| 1 | Designing, Supplying, Installation, Testing & Commissioning with all tools & Parts of following Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump Suitable for minimum 125mm x 115mm bore well as per MNRE Guideline with following specifications & accessories. A SPV arrays contains specified No of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual PV modules should be minimum 200 watt peak.i) The SPV modules should be as per IEC-61215 and IEC 61730 part 1.0) ii) All external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required.iii) The PV modules should be mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & High wind pressure up to 200Km/h. iv) The module mounting structure should be hot dip galvanized according to IS 4759. v) To enhance the performance of SPV water pumping system & arrangement for seasonal tilt angle Adjustment should be providedv . vi) Necessary arrangement should be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE Specification) .vii) Necessary protection such as lightening arrestor etc. should be provided to protect the controller & SPV. viii) The suction/delivery pipe shall be UPVC / H.D.P.E. pipes of appropriate size 60m or more as required minimum pressure rating of 8kg/Sq cm- PE 100 grade for pump up to 3HP & 10 Kg/Sq cm- PE 100 grade for 5 HP. ix) All cable used shall be as per IS 694. Suitable size of cable shall be used in sufficient length for inter connection between the SPV array to SPV controller and SPV controller to solar power pump. Provision of cable shall be as per IS 14536. x) The motor pump set should have a 5 years warranty. xi) Control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box. (As per MNRE Specification) . xii) The SPV controller must have IP-65 protection or must be housed in cabinet having at least IP-65 protection. xiii) The system should be as per MNRE guide line & Eco-friendly with suitable arrangement to operate new pump manually. xiv) With third party inspection before dispatch.xv) Fitting, fixing & mounting on water tank steel structure. xvi) Provision for web based remote monitoring of the pumps to be installed must be made through the inbuilt controllers . It should be possible to ascertain the daily water output, the power generated by PV Array ,the Up and down time of the pump during the year, number of days the pump was unused or under breakdown repairs. The following details should be marked indelibly on the motor pump set. a) Name of the Manufacturer or Distinctive Logo. b) Model Number. c) Serial Number. B Solar submersible motor pump (SPV DC Type). i) 1 HP (DC Pump) with 900 WP minimum watt P.V. Panel as MNRE pump head Max Shut-off head up to 120 mtrs. For higher or lower head or in between various modules output could be decided on prorates basis. (As per latest guide line of MNRE) |
| 2 | Carrying out recuperation/Yield Test for ascertaining the discharge of constructed well/ excavated profile as directed by the IEC. The test out by the drawing down water from the well/ profile below normal/subsoil water level up to full depth rise is recorded the normal water level/subsoil water level in the well / profile as well as strainer/level at pump as per design of W.S. scheme shall be recorded prior to the test including cost of all materials, over Load , Labours etc. complete as directed. |
| 3 | Supplying all labours, tools and equipments for dismantling of head & water tank assembly and taking out 32 mm dia old G.I. Pipe, connecting rod, cylinder assembly the dismantled components after necessary changing for making the T/W in good condition with all transportation including unused taken out materials back in store all complete job as per direction of E/I.(As per Model Estimate of Solar Energy based Mini WSS. TS done by SE, Ranchi Circle & Circle Gumla dt. 21.05.2019) |
| 4 | Provision of solar night lamp. |
| 5 | Earth work in excavation in foundation trenches in ordinary soil and disposal of excavated earth as obtained to a distance up to 50.0m ,including all lifts, levelling ,ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design ,building specification and direction of E/I (vide classification of soil item -B) |
| 6 | Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) |
| 7 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 8 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 11 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mmnominal size). |
| 12 | providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. (a) 10mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)} |
| 13 | providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. (a) 12mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)} |
| 14 | Providing structural steel galvanised tubular hollow section work in trusses, other similar trussed purlins and members with all bracing ,gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge ,including cutting fabricating ,hoisting , erecting and fixing in position , making riveted/bolted /welded connections and one coat of anticorrosive paint and over it two coat of all oil painting & For Structure(PLUS) Providing and applying materials &labour for hot dip galvanizing of above structure including transportation for galvanizing minimum thickness 80microns (Net wt. of components to be Galv) preferably TATA structural section etc complete. |
| 15 | Providing structural steel work in trusses other similar trussed purlins and members with bracing gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge including cutting fabricating hoisting erecting and fixing in position making reverted bolted welded connections one coat of anticorrosive paint and over it two coats of oil painting etc complete (MJP 2021-2022 Sec F Item 6) |
| 16 | Materials and labour for vinyl painting of matter given by department in different color (As per Market Rate) |
| 17 | Providing and fixing HDPE container Syntex or alike one piecemolded water tank made out of low density polythyler andbuilt corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity 2000.00 litres Capacity Water storage Tank(DWSD item No-01 M) |
| 18 | Transportation Charge |
| 19 | Lifting of 2000 Litrs Capacity Tank up to 4.5m height with lifting tools with rope and labour |
| 20 | Making hole in Tank |
| 21 | Making long screw in G.I. pipe including supplying and fitting jam nuts and extra socket etc. |
| 22 | Earth work in excavation in foundation trenches in hard soil (Vide Classification soil item B) and disposal of excavated earth as obtained to a distance up to 50 Mtr. including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, specification and direction of E/I. |
| 23 | Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 24 | Manufacture, supply and Delivery of following Nominal dia UPVC column pipes including PVC socket (Coupler), 65mm dia -Density of pipe 1.38 to 1.43 Gm per Cm3 OD:74.5 to 75.2mm wall Thickness End:9mm to 10.7mm, Barrel 9mm to 10.7 mm, Length: 3Mtrs.Rising main |
| 25 | Manufacture, supply and Delivery of following Nominal dia UPVC column pipes including PVC socket (Coupler), 50 mm dia -Density of pipe 1.38 to 1.43 Gm per Cm3 OD:87.5 to 88.2mm wall Thickness End:9 .8 mm to 11.9mm, Barrel 7.3mm to 9 mm, Length: 3Mtrs. Delivery Pipe. |
| 26 | Providing and supplying High Density Polyethylene pipe (HDPE pipe) of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10 (Item No-112M 1028) . 63 mm HDPE Pipe- |
| 27 | Providing and supplying High Density Polyethylene pipe (HDPE pipe) of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10 (Item No-112M 1028) . 50 mm HDPE Pipe- |
| 28 | Providing and supplying High Density Polyethylene pipe (HDPE pipe) of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10 (Item No-112M 1028) . 32 mm HDPE Pipe- |
| 29 | Providing and supplying High Density Polyethylene pipe (HDPE pipe) of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10 (Item No-112M 1028). 20 mm HDPE Pipe- |
| 30 | Providing and fixing Gun metal gate valve with CI wheel of approved quality ( Screwed end). 50mm Dia |
| 31 | Providing and fixing Gun metal gate valve with CI wheel of approved quality ( Screwed end).65 mm Dia |
| 32 | Providing and supplying High Density Polyethylene (HDPE ) fittings of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10 |
| 33 | Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II. MJP 19-20 sec-I-IX sl no -2(i) 50mm HDPE pipe |
| 34 | Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II. MJP 19-20 sec-I-IX sl no -2(ii) 65mm HDPE pipe |
| 35 | Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II. MJP 19-20 sec-I-IX sl no -2- Distribution (i) 65mm HDPE pipe |
| 36 | Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II. MJP 19-20 sec-I-IX sl no -2- Distribution (ii) 50mm HDPE pipe |
| 37 | Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II. MJP 19-20 sec-I-IX sl no -2- Distribution (iii) 32 mm HDPE pipe |
| 38 | Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II. MJP 19-20 sec-I-IX sl no -2- Distribution (iii) 20 mm HDPE pipe |
| 39 | Providing 15 mm dia. G.I. pipe Tata or equivalent make as per IS 1239 (Part 1/2004) ISI Mark /medium quality in Stand Post. |
| 40 | Supplying all materials , labour and tools for fixing 15 mm dia G.I. pipes with Red lead and yarn of following nominal bore with screwed and socketed joints on wall, ceiling and floor including supplying and fitting of wall hooks or pipe clamps, wooden plugs, cutting pipes to size and threading ends if required etc. all complete as per specification and direction of Engineer-in-Charge. DWSD 3.1.2(i) |
| 41 | Supplying and fixing G.I. fittings of approved make all complete as per specification and direction of E/I. Elbow 15 mm Dia |
| 42 | Supplying and fixing G.I. fittings of approved make all complete as per specification and direction of E/I. Reducing Socket 20 mm Dia |
| 43 | Supplying and fixing G.I. fittings of approved make all complete as per specification and direction of E/I. Nipple . 15 mm Dia |
| 44 | Supplying and fixing G.I. fittings of approved make all complete as per specification and direction of E/I. Plain Socket . 15 mm Dia |
| 45 | Supplying and fixing G.M. ferrule of approved make in existing C.I./D.I. main Including drilling and taping C.I./D.I. main all complete as per specification and direction of E/I. 3 mm, 6 mm 10 mm dm ferrule weight not less than 425 gram. |
| 46 | Providing and fixing Gun Metal full way valve of approved quality, all complete, as per specification and direction of E/I. 50 mm Dia and weight not less than 1.5 Kg |
| 47 | Providing and fixing Gun Metal full way valve of approved quality, all complete, as per specification and direction of E/I. 65 mm Dia Full way valve |
| 48 | Providing and fixing of male ended C.I.Body brass spindle valve and seat Bib cock of approved quality with extra socket all complete as per specification and direction of E/I. 15 mm Dia and wt. not less than 400 gm. |
| 49 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design.With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. fullway valve chamber |
| 50 | Supplying materials , labours and equipment's for construction of 0.90M x 0.90 M size P.C.C. (1:2:4) Rectangular Platform with stand post in house including 12 mm thick cement plaster in C.M. (1:4) with neat cement punning over exposed surface all complete job, as per approved design, specification and direction of E/I. (As per Annexure II Attached) . 1.20 M x 0.90 M size P.C.C. (1:2:4) Rectangular Platform - |
| 51 | Providing brick masonry chamber of inner size 600 x 600 x 450 mm deep for bore well protection having 125 mm thick wall and 75 mm R.C.C cover including cement plaster of exposed surface, etc all complete job (Annexture I). |
| 52 | Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge. |
| 53 | Providing fitting & fixing 32 mm to 50 mm service HDPE saddle all complete job, as per approved design, specification and direction of E/I. |
| 54 | Operation & Maintenance cost based on Existing D/T Well with solar motor pump for 1 years. (Excluding Repair Charges) |
| 55 | Operation & Maintenance cost based on Existing D/T Well with solar motor pump for 2nd Year = O & M for 1st Yr + 6% of O&M for 1st Year + Annual repairing Charges |
| 56 | Operation & Maintenance cost based on Existing D/T Well with solar motor pump for 3rd Year =1.06 x 2st year |
| 57 | Operation & Maintenance cost based on Existing D/T Well with solar motor pump for 4th Year =1.06 x 3rd year |
| 58 | Operation & Maintenance cost based on Existing D/T Well with solar motor pump for 5th Year =1.06 x 4th year |
| 59 | Provision of one no SIM card & its recharging cost for RMC |
| 60 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 61 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I. |
| 62 | Providing designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 63 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 64 | Carriage of materials Sand |
| 65 | Cement |
| 66 | Stone chips |
| 67 | Brick |
| 68 | G.S.T @ 18% |
| 69 | Labour Cess 1% Please Enable Macros to View BoQ information |