| 1 | SH-I One Time Special RepairRewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. a) Group C |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. a) Group C |
| 3 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. a) 3 x 1.5 sq. mm |
| 4 | b) 6 x 1.5 sq. mm |
| 5 | c) 3 x 4 sq. mm |
| 6 | d) 6 x 4 sq. mm |
| 7 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.a) 20 mm |
| 8 | b) 25 mm |
| 9 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm |
| 10 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. a) 1 or 2 Module (75mmX75mm) |
| 11 | b) 3 Module (100mmX75mm) |
| 12 | c) 6 Module (200mmX75mm) |
| 13 | d) 8 Module (125mmX125mm) |
| 14 | e) 12 Module (200 mmX150 mm) |
| 15 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.a) 5/6 amps switch |
| 16 | b) 3 pin 5/6 amp socket outlet |
| 17 | c) Bell push |
| 18 | d) Blanking Plate |
| 19 | e) 15/16 A switch |
| 20 | f) 6 pin 15/16 A socket outlet |
| 21 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.a) 1 or 2 Module |
| 22 | b) 3 Module |
| 23 | c) 4 Module |
| 24 | d) 6 Module |
| 25 | e) 8 Module |
| 26 | f) 12 Module |
| 27 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 28 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 29 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 30 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/ 6 A modular switch, connections etc. as required. |
| 31 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 32 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 33 | Supplying and fixing following way, single pole and neutral, sheet steel, with MCB distribution board, 240 V, on surface/ recess, complete tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)a) 12 way Double door |
| 34 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole |
| 35 | b) Single pole and neutral |
| 36 | Providing and fixing following rating and breaking capacity and poleMCCB with thermomagnetic release and terminal spreaders inexisting cubicle panel board including drilling holes in cubicle panel,making connections, etc. as required. a)125 A,36KA,FPMCCB |
| 37 | b)200 A,36KA,FPMCCB |
| 38 | Supplying & fixing of 300 mm sweep 1400 RPM 230 Volt 1-ph 50 Hz AC heavy duty Exhaust fan in the existing opening including making good the damage, connection, testing and commissioning etc. as reqd. |
| 39 | S/I/T/C of 1200 mm sweep BEE star rating energy efficient ISI marked ceiling fan capacitor type with double ball bearing suitable for operation of single phase AC supply with power Consumption of Max. 50W capable to deliver 220 CFM (min.), speed of 350 rpm (min.) i/c wiring the down rod of standard length (upto 30 cm) with 1.5 Sqmm FR PVC insulated copper conductor single core cable etc and help of steel chain approx. 1 mtr x 2 nos. as reqd. (i/c dismantling the old fitting if any) |
| 40 | Supplying, installation, Testing & Commissioning of LED surface mountedBatten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 5700°K /6000°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 18- 22 watt |
| 41 | Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 5700°K/ 6000°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 36 watt |
| 42 | Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor armoured power cable of 1.1 kV grade of following size on wall surface as required. a) 4 X 16 sq. mm Alu. Cable. |
| 43 | Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg- 120deg as per the application and the project requirement deg, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 5700°K /6000°K(As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 200 watt |
| 44 | S/I/T/C of Starter Control panel for 3 phase motor upto 7.5 HP having DOL starter of relay range 9 to 14 Amp. on the wall mounting comprising of contactor, relay, single phase preventor, auto-manual On/Off voltage selector switch, voltmeter, ammeter, push buttons etc. as reqd. |
| 45 | SH:-II Routine MaintenanceRunning maintenance and operation of all EI wiring, Light points / Fan Points / Exhaust Fan Points / Call Bell Points, Light / Power Plug Points, AC Points, EDB, Main Board, Street Light Points, Fittings, Ceiling Fans, Exhaust Fans, Brass Batten / Angle Holder, Call Bells, Buzzer etc. by deputing the following experience staff including Sunday and holidays as per terms and conditions attached. (For 15 Days in a month)Staff engaged by the contractora) Wireman cum operator: 01 No.b) Khallasi: 01 No. |
| 46 | SH-III (Minor repair of Pumpset Work)Rewinding of following size Submersible/Mono submersible/monoblock Pumpset with copper rewinding wire incl. dismantling of Pumpset from site, cartage from site to work shop and return back to site, cutting the burnt winding wire (i/c credit for old winding wire) along with installation, testing & commissioning etc. as reqd. at site.a) Upto 5 HP |
| 47 | Lowering of upto 7.5 HP Mono Submersible/Sewage/ Submersible P/set along with G.I. pipe in existing well/underground tank with the help of chain pulley and tripod etc. as reqd. |
| 48 | Taking out of upto 7.5 HP Mono Submersible/Sewage/ Submersible P/set along with G.I. pipe in existing well/underground tank with the help of chain pulley block and tripod complete as reqd. Please Enable Macros to View BoQ information |