|
| 1 | Charges for repairing of leakages in UPVC / HDPE pipe line with PVC coupler and solvent cement etc. including necessary earth excavation backfilling of soil as required after laying of pipe line in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. complete as per specification and direction of the Engg.-in-charge. |
| 2 | (i) 90mm OD |
| 3 | ii) 110mm OD |
| 4 | iii) 140mm OD |
| 5 | Removal of blockage after earth excavation from existing distribution pipe line of all diameter as well as washing by inserting cutter fitted to the 40/25 mm dia UPVC coil pipe up to the length of 30.00m and both side by cutting of pipe at any depth including necessary dewatering when ever required and refilling the excavated soil properly complete as per direction of the Engineer-in-charge. (Bituminous road cutting, C.I. specials, PVC coupler laying of pipe line, lead joint will be paid separately but PVC coil 40/25mm dia will be supplied by the agency.) |
| 6 | a) For D.I/C.I / G.I pipe |
| 7 | b) For PVC/HDPE pipe |
| 8 | Providing, fixing and laying fabricated UPVC socket / coupler conforming to IS : 10124 ( Part 2 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 9 | (i) 90 mm dia |
| 10 | (i) 110 mm dia |
| 11 | iii) 140 mm dia |
| 12 | Charges for dismantling PVC / HDPE pipe after necessary excavation of earth including washing and stacking of pipes properly at site with all leads and lifts and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. complete as per specification & direction of the Engineer-in-charge. |
| 13 | (i) 90 mm dia |
| 14 | (i) 110 mm dia |
| 15 | iii) 140 mm dia |
| 16 | Providing and fixing Moulded UPVC end cap conforming to IS: 7834 (Part-8) complete as per CPWD Specification and direction of the Engineer-in-Charge. |
| 17 | (i) 90 mm dia |
| 18 | (i) 110 mm dia |
| 19 | Providing and fi xing C.I. sluice valves (with cap) completewith bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge. |
| 20 | i) 80 mm diaa) PN - 1.6 |
| 21 | ii) 100 mm diaa) PN - 1.6 |
| 22 | Providing, fixing and laying flanged fabricated UPVC tail piece conforming to IS : 10124 ( Part 6 ) with G.I. flange ( 8 mm thick ) with solvent cement conforming to IS - 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 23 | (i) 90 mm dia |
| 24 | (ii) 110 mm dia |
| 25 | Providing and fitting fixing of D.I mechanical joint (J.P coupling) in/c rubber washer and nut botls as per direction of the Engineer-in-charge. |
| 26 | i) 150 mm dia |
| 27 | ii) 200 mm dia |
| 28 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.-All kinds of soil |
| 29 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 30 | Filling in Foundation Trenches as per drawing and MoRD technical specification Clause 305.3.9, 1200.i) Sand Filling |
| 31 | Flat Brick solingProviding and laying flat brick soling layer on prepared subgrade according to lines, grades and cross-section shown on the drawing, filling joints with Earth, free from clay with a Plasticity Index not exceeding 6, watering and rolling the same with three wheeled road roller 80-100 kN as per MoRD Technical Specification Clause 412. |
| 32 | Providing, fixing and laying rigid UPVC pipes conforming to IS : 4985 jointing with couplers, of same class conforming to IS : 10124 ( Pt-II ) with solvent cement conforming to IS : 14182 including testing of joints complete ( but excluding the cost of specials like bend, tees etc. which will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.A) Class - 3 ( working pressure 6.0 kg / cm2) |
| 33 | (i) 40 mm dia |
| 34 | (i) 50 mm dia |
| 35 | (i) 90 mm dia |
| 36 | (i) 110 mm dia |
| 37 | Excavating trenches of required width for pipes, cables etc. in/c excavation for sockets and dressing of sides ramming of bottoms depth up to 1500 mm(slope -1 in 200) in/c getting out the excavated soil and back filling of soil as required after laying of pipeline in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per CPWD specification and direction of the engineer-in-Charge.A) For UPVC pipes in new work(a) In all kinds of soil. |
| 38 | (i) For pipes not exceeding 90 mm dia |
| 39 | (ii) For pipes exceeding 90 mm dia but not exceeding 300 mm dia |
| 40 | Making road crossing by horizontal boring for smooth laying of UPVC / CI / DI / GI pipes etc. of required dia complete as per specification and the direction of the Engineer-in-charge.A. by manual means |
| 41 | Providing and fixing brass ferrule with C.I. cover conforming to IS : 2692 including boring and tapping the main as per CPWD specification and direction of the Engineer - in - chargea) 10 mm dia nominal bore. |
| 42 | Providing and laying of flexible PVC pipe (conforming to IS:7634) complete as per specification and direction of the of the Engineer-in-Charge. |
| 43 | (a) 15 mm dia |
| 44 | (b) 32 mm dia |
| 45 | Providing and fixing G.I. Bend/Elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer-in-charge. i. 15 mm dia |
| 46 | Providing and fixing G.I. socket as per CPWD specification and direction of the Engineer-in-charge. (a) 15 mm dia |
| 47 | Providing and fixing G.I. union as per CPWD specification and direction of the Engineer-in-charge. (a) 15 mm dia |
| 48 | Providing and fixing G.I. Nipple of mediumclass as per CPWD specification and direction of the Engineer-in-charge.(i)15mm dia 150 mm long |
| 49 | Demolishing cement concrete manually / by mechanical means including disposal of material with all lifts and upto 50 m lead etc. complete as per direction of the Engineer- in-charge:-i) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 50 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:i) 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size) |
| 51 | Labour charge for lifting of 2 HP / 3 HP submersible pump with motor in/c column assembly by chain pulley block as per direction of the Engineer in charge. |
| 52 | Labour charge for lowering of 2 HP / 3 HP submersible pump with motor in/c column assembly by chain pulley block as per direction of the Engineer-in-charge. |
| 53 | Repair and maintenance of submersible Motor suitable for submersible pump set by complete dismantling in/c providing & fitting fixing of PVC ( IS : 8783-1978 ) insulated electro grade copper ( IS : 613-1984 ) conductor winding in stator & all necessary spare parts and reassembling the same including servicing of rotor & necessary trial run as per specification and direction of the Engineer-in-charge.i) 2.0 HP Motor suitable for 2000 GPH capacity submersible pump set. |
| 54 | Repairing of 2HP/3HP capacity submersible pump of different make in/c dismantling the old unserviceable pump and remaking the pump in good condition by providing necessary parts etc. complete as per direction of the Engineer-in-charge. |
| 55 | Providing & fabrication of column pipe including fitting fixing of G.I. flange by cutting the GI pipe ( conforming to IS : 1239 medium class ) into 3.05 mtr. long and welding the same with GI flange as per specification and direction of the Engineer-in-charge (G.I. pipe will be provided by the agency at his own cost & risk)i) For 50 mm dia G.I. pipe with 10 mm thick GI flange. |
| 56 | Providing and fitting fixing with PVC insulated 3 core flat Copper cable conforming to relevant IS code for submerssible motor with all necessary equipments and fittings as required as per specification and direction of the Engineer-in-charge.i) 2.50 sqmm |
| 57 | Washing and development of tube well by using hand pump or by any suitable method and testing of the well as per specification and direction of the Engineer - in - charge. |
| 58 | Providing and fitting fixing of double pole and neutral 32-Amps Switch fuse unit (main switch) SPL make item code-No SFSRW2Dp-32 as per direction of the Engineer-In-Charge. |
| 59 | Providing and fitting fixing of one phase submersible pump starter with two pole contactor and relay range 17.4-204 A in/c. Amps meter and volt meter panel 3-HP cat no CPMSNBW-SP volt meter as per direction of the En-in charge. Please Enable Macros to View BoQ information |