| 1 | 25.1:Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminum extruded section shall be taken for purpose of payment |
| 2 | OD439907/2025-2026:Designing, fabricating, , installing and fixing in position special design Aluminium CompositePanel Cladding linear as well as curvilinear portions of the building , for all heights and alllevels etc. including: a) Structural analysis as per relavent IS codes . b) Providing, fabricatingand supplying and fixing panels of aluminium composite panel cladding in required shape inmetalic colour of approved shades made out of 4mm thick aluminium composite panel materialconsisting of 3mm thick core sandwiched between two Aluminium sheets (each0.5mm thick).The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500basedPVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts,washers, cleats, weather silicone sealant, backer rods etc. The item includes cost of all material& labour component, the cost of all mock ups at site,cleaning and protection of the cladding tillthe handing over the building for occupation. . Base frame work for ACP cladding is payableunder the relevant item.s The Contractor shall provide aluminium composite panel cladding,having all the performance characteristics all complete , as per the Architectural drawings, asper item description, as specified, as per the approved shop drawings and as directed by theEngineer-in-Charge. However, for the purpose of payment, only the actual area on the externalface of the curtain wall with Aluminum Composite Panel Cladding (including width of groove)shall be measured in sqm. up to two decimal places (Modified 25.7) |
| 3 | 13.99.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work |
| 4 | OD440027/2025-2026:Providing and fixing stainless steel (Grade 304) three dimension English Letters or Numbers ,22 gauge front side and projection 24 gauge including buffing, polishing and and fitting thesame with necessary stainless steel nuts and bolts complete, i/c fixing the Letters to the wallwith necessary accessories & stainless steel dash fasteners, stainless steel bolts etc. as perapproval of Engineer-in-charge, 35.00 cm height SS 3D letters |
| 5 | 8.2.2.2:Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm |
| 6 | 16.21:Engraving letters in hard stone |
| 7 | 10.25.2:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works Please Enable Macros to View BoQ information |