| 1 | Class-150 (Non Modular) brick work in 1:4 cement and Coarse sand mortar in foundation and plinth including supply of all materials, labour and T&P etc. required for proper completion of the work. (PWD SOR 2025-26 Chapter No-06 Item No. 2 Spec. No. 6.1) |
| 2 | Proving and laying cement concrete in 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and curing complete, including cost of form work. (PWD SOR 2025-26 Chapter No-05 Item No. 7 spec. No. 4.1) |
| 3 | 12mm Cement plaster with cement mortar in proportion of 1:3 cement & coarse sand of single coat for interior plastering upto floor two level including internal rounded angles chamfers, and rounded angles not exceeding 80mm in girth and finished even and smooth.. (PWD SOR 2025-26, Chepter-7, Item No.1 Spec. No. 13.9) |
| 4 | Tack Coat Providing and applying tack coat with bitumen VG-10 using bitumen pressure distributor at the rate of 0.30 kg per sqm on the prepared bitumenous surface cleaned with mechanical broom.(As per Analysis). |
| 5 | Bituminous ConcreteProviding and laying bituminous concrete with higher capacity batch type hot mix plant using creshed aggergates of specified graing, premixed with bituminous binder @ 5.4 percent of mix and filler, transporting the mix to work site, laying with a hydrostatic paver finisher with senser control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects. (As per Analysis) |
| 6 | Grandular Sub-base with well Graded Material (Table 400.1) (A) By Mix in Place MethodConstruction of granular sub-base by providing well graded material, spreading in uniform layers wth motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheelo roller to achieve the desired density. complete as per technical spercification clause-401 (As per Analysis). |
| 7 | RCC work Providing and laying in position specified grade of reinforced cement concrete in Raft foundation, including the cost of centering, shuttering, finishing and excluding reinforcement - All work up to plinth level in :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) (PWD SOR 2025-26, Chepter-5, Item No.9 Spec. no. 5.1). |
| 8 | R.C.C work in Wall (any thickness) including attached plasters, buttresses, plinth and string courses, fillers, columns, pillars, abutments, post and struts etc. including the cost of centering, shuttering, finishing and excluding reinforcement All work up to plinth level in 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) upto plinth level (PWD SOR 2025-26, Chepter-5, Item No.9 Spec. no. 5.2) |
| 9 | RCC Work Providing and laying inposition specified grade of reinforced cement concrete, including the cost of centering, shuttering, finishing and excluding reinforcement All work upto plinth level :1:1.5:3 (1cement :1.5 coarse sand: 3graded stone aggregate 20mm nominalsize) (PWDSOR 2025-26 Chapter No-05 Item No.8 Spec. No. 5.1). |
| 10 | Supply & Laying precast concrete blocks (Interlocking Tiles) for paving of thickness 100mm (Compresive strength not less then 30 mpa) Including 25 mm theick local sand Base leveling and dressing of surface to requred level and slope] filling Jointsa With local sand all complete work as speciefied in IS 15658:2006. (PWD SOR 2025-26 Chapter No-12 SI No. 10 New Item) |
| 11 | P/L of hot applied thermoplastic compund 2.5 mm thick including trorising glass beeds @ 250 gm per sam area. Thickess of 2.5 mm in exclusive of surface applied glass beeds etc. …………Including cost of all material, labour, T&P etc. require for proper completion of work as direction by E/I. (PWD SOR 2025-26, Chepter-14, SI No. 02 Morth-803 (8.13). |
| 12 | Suppy & Fixing of pavment Makers (Cat Eye) Type XASTMD-4956-04 Avery Dennison/3-M (USA Make) consisting of ASA plastic housing fitted with tightly aderent plotting compound. The housing shall contain prismatic two glass coverd prismatic reflective face to reflect light I/Call tax. With shanks (PWD SOR 2025-26, Chepter-14, SI No. 05 Morth-804 (8.35). |
| 13 | Solar power road marker (Solar Studs) (Cat Eye) Type XASTMD-4956-04 Avery Dennison/3-M (USA Make) consisting of ASA plastic housing fitted with tightly aderent plotting compound. The housing shall contain prismatic two glass coverd prismatic reflective face to reflect light I/Call tax. With shanks (PWD SOR 2025-26, Chepter-14, SI No. 16 Morth-804.6 (8.35). |
| 14 | M.S or Iron work in plain work such as reinforced concrete or reinforced brick work (When not included in and an over all rates) brought to required shape as necessary of the work and including the suply of steel and its wastage bend, hooks and authorized over lapping shall be measured upto floor to level. (As per Analysis of Rate) |
| 15 | Distempering (two coat) with oil bound distemper of approved brand ……………………………………. Include all materials. (PWD SOR 2025-26, Chepter-8, Item No. 13+14 (649+650). |
| 16 | M.S Speciefication Board including painting & writing |
| 17 | P/F of Inogration Granite stone including writing and Please Enable Macros to View BoQ information |