| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Superintending Engineer, ESWC, Aligarh. Name of Work: Increasing capacity of 33/11kv Sub-stations Iglas, Aligarh 2x10 To 2X10+1X5 MVA Under Business Plan 2026-27 (Semi Turn Key Basis) Turn Key E-Tender No: ESWCA-06/2026-27 |
| 2 | Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Work Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Rates Quoted Per Unit with GST & All Taxes Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT With GST & All Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 3 | Safe Carriage of following store items with loading & unloading at both ends respectively. (under jurisdiction of DVVNL) to praposed site |
| 4 | ACSR Dog conductor |
| 5 | 11KV incoming with CT ratio 600/300/5A, 350 MVA |
| 6 | 11KV Outgoing with CT ratio 200/100/5A, 350 MVA |
| 7 | 90 Lbs. Rail pieces for T/F |
| 8 | 33 KV Single Transformer Control Panel. |
| 9 | 33 KV VCB 800A, 750 MVA |
| 10 | 33 KV CT, 200/100/1-1-1A |
| 11 | 33 KV Fuse Set |
| 12 | 33 KV PT (33KV/110 Volt) |
| 13 | 33 KV XLPE Cable 3×300 mm2, |
| 14 | 33 KV Cable Jointing Kit 3×300 mm outdoor |
| 15 | 11 KV 3 Core XLPE Cable Al. 3x300 Sq.mm |
| 16 | 11 KV 3 Core XLPE Cable Al. 3x185 Sq. mm |
| 17 | 11 KV Cable Jointing kit. Heat 3x300 Sq. mm Indoor |
| 18 | 11 KV Cable Jointing kit. Heat 3x300 Sq. mm Outdoor |
| 19 | 11 KV Cable Jointing kit. Heat 3x185 Sq. mm Indoor |
| 20 | 11 KV Cable Jointing kit. Heat 3x185 Sq. mm Outdoor |
| 21 | 33 KV Bus Type Isolator. |
| 22 | 33 KV Post Insulator. |
| 23 | 33 KV Lightening Arrestors |
| 24 | 8.5 Mtr. PCC Pole |
| 25 | 11 KV Polymeric Pin Insulator |
| 26 | 11 KV TPMO |
| 27 | 11 KV Fuse Set |
| 28 | LT Cable 3.5x70 sqmm Al |
| 29 | Complete Stays (Stay Set, GI Stay rod 20x1800, Stay wire 7/8 SWG 10 kg, Stay Clamps and Nut bolt & washer |
| 30 | M.S Earthing Complete (20x2540mm) |
| 31 | Supply Providing of follwoing materials (Decentralized materials) by contractor with all Associatas accessories like all Type Clamps, Nut& Bolts etc. |
| 32 | Structure for 33 KV Bus Type Isolator |
| 33 | Structure for 33 KV PT |
| 34 | Structure for 33 KV CT with Junction Box |
| 35 | Structure for Post Insulator. |
| 36 | Structure for 33 KV Lightening Arrestors |
| 37 | Structure for 33 KV Fuse Set |
| 38 | G.I Pipe 6 inch Dia |
| 39 | Holding clamp for 3x300 xlpe cable 11 kv |
| 40 | M.S. Nut Bolt off size with washer |
| 41 | PG Clamp Dog to Dog |
| 42 | Equipment Earthing with all requried material up to water level (minimum 50 Mtr.) |
| 43 | Outdoor Equipment Earthmat |
| 44 | Control Cable 4x2.5 Sq. mm.Cu. Xlpe (Armoured) |
| 45 | Control Cable 2x2.5 Sq. mm.Cu. Xlpe (Armoured) |
| 46 | Painting of Substation Structure |
| 47 | Structure For cable support of power T/F |
| 48 | \\"L\\" Type Structure for Neutral |
| 49 | Structure For cable support for 33 KV XLPE Cable all requried material provided by firms. |
| 50 | G.I. Barwed wire |
| 51 | Stay Insulator |
| 52 | Danger Board with clamp |
| 53 | Number Plate Clamps With Bolts & Nuts. |
| 54 | MS Channel 100x50x2028mm (fuse set) |
| 55 | Stone Pad 300x300x75 |
| 56 | Clamp (T- OFF) bolt and nut |
| 57 | Holding Clamp for Top Channel for Fuse Set Etc with Bolts & Nut. |
| 58 | M.S angle 65x65x6 mm with clamp & bolt and nut (T&F base) |
| 59 | MS Channel 125x65x2240mm (Top Channel) |
| 60 | Silica Gel Breather with pot For 5 MVA Power Transformer |
| 61 | OTI For 5 MVA Power Transformer |
| 62 | WTI For 5 MVA Power Transformer |
| 63 | HV Side Brass connectors with Nut & Bolts |
| 64 | LV Side Brass connectors with Nut & Bolts |
| 65 | Erection of following Material & Miscellaneous Electrical Works. (As Per Resspo Norms) :- |
| 66 | Plinth & Foundation of 33 KV PT (1 No), 33KV CT (1 No), Post Insulator (2 No), 33 KV Lightening Arrestors (1 No), 33 KV Fuse Set (1 No) as per Resspo Noms. |
| 67 | LINE/BUS ISOLATOR STRUCTURE: (3Nos.) Erection of Structure, including cutting, straightening & drilling of holes in Channel/Angle. |
| 68 | Fuse Set/L.A./P.T/POST INSULATOR STRUCTURES (1+1+1+2): Erection of structure, including cutting, straightening & drilling of holes in Channel/Angle/Joists. M.S.Plate to be fixed on structure of required size. |
| 69 | Plinth for 5 MVA/8 MVA Transformer Qty 01 Nos. |
| 70 | Construction of plinth for 5 MVA/8 MVA, 33/11 KV Transformer of (3.46x4.46x1.0)m (0.50m below ground level and 0.5 m above ground level) as per details & drawing attached (All required matrials provided/Supply by the contractor own his cost):-Excavation of earth in foundation. |
| 71 | Cement concrete in foundation in ratio 1:6:12, Cement, Sand & Brick ballast. |
| 72 | First Class Brick work in ratio 1:4 with Cement & Coarse sand mortar. |
| 73 | Cement concreting inner side of plinth in ratio 1:4:8, Cement, Coarse sand and stone shingle. |
| 74 | M.S.work for re-inforcement 12mm. Tor at a distance of 15Cms. apart, including cutting, bending & binding by wire to each other for making JAL in two layer, 12 to 15Cms. apart. M.S.12mm Tor bar provided by the contractor his own cost. |
| 75 | Fixing of 3.46 Mtr.long, 2No. Rail Pices, 90Lbs, on top of Plinth at proper distance in alignment by C.C. |
| 76 | Cement concrete in ratio 1:2:4, Cement, Coarse sand & Stone shingle, on top of the plinth, including fixing of M.S.Tor Jal. |
| 77 | 12mm.thick Cement Plaster in ratio 1:4, Cement & Sand mortar, on all side of plinth. |
| 78 | Neat cement coating 3mm.thick on top surface of plinth. |
| 79 | Plinth for 33 KV V.C.B. |
| 80 | Construction of plinth for the structure of 33 KV VCB & C.T.’s as per details for . (All required materials provided / Supply by the contractor own his cost) :-Excavation of earth of size 2x(2.0x2.0x1.0)m pits for construction of plinth. |
| 81 | Brick Ballast ratio (1:4:8) (cement, sand & brick ballast) for foundation work 2x(2.0x2.0x0.5)m plinth. |
| 82 | R.C.C. work in ratio 1:2:4 (cement, coarse sand & stone grit) of 20m size for making plinth of size 2x(2.0x2.0x1.0)m and grouting of foundation bolts 04 Nos. for 33 KV VCB. |
| 83 | 12mm thick plaster with cement mortar in ratio 1:4 (cement & fine sand) of plinth of 0.4m upper side |
| 84 | Earthing of indoor equipment, details as given below:- |
| 85 | Cutting of 32mm.dia M.S. Bar-3Mtr.long and making one end in conical shape by forging process and driving it into the earth at each corner of bridge outside control room and proper welding with M.S.Bars. |
| 86 | Digging of Pits for making Bridge on both side of control room by laying 32mm. dia M.S.Round in rectangular shape. Electric welding on cross joints by providing “U” Clamp in size 25x6mm. of M.S.Flat and inter connecting both by M.S.Round 32mm.dia through control room trench, with over lap joint by providing M.S.Round-12mm dia, on both sides of over lap joints of M.S.Round, by electric welding. All joints shall be painted with black bituminious paint. |
| 87 | Outdoor Switchyard Earthing with 32mm size Earth Mat with Delta earthing on Power Transformer 02 Nos. Body Earth, 33KV LA , 33 KV CT, 33 KV PT, 33KV Fuse Set, 33KV Bus Isolater, 33KV VCB & 33KV PI Including connecting MS Strip of size 50x6 mm at both site (As per Resspo Specification) |
| 88 | Water level earthing by Boring and lowering of G.I. pipe size 40 mm dia & thickness 3mm into the ground at 30 Mtr depth or upto the water level with the lower end of solid copper cone Approx 225 mm long and 750 gm in weight shall be provided and screwed in pipe as well as bringing out a continuous copper wire 6 SWG from the cone up to the ground surface where it will be bolted to the G.I. earth Strip for Transformer neutral connection, the G.I.Earth strip size 50x6mm will be welded to the G.I. pipe and neutral earthing support & other installed equipment in switchyard. All required material provided / supply by the contractor own his cost. |
| 89 | CONSTRUCTION OF CONTROL CABLE TRENCH WITH TRENCH COVER IN SWITCHYARD, AS PER Specifation (All required matrials provided/Supply by the contractor own his cost):- |
| 90 | Installation of 5/8/10 MVA Transformer and other accessories equipments. |
| 91 | Fabrication and erection of neutral earthing L Type support made of G.I. Channel size 100x50mm. Structure shall be 4 Mtr. Long with 1 Mtr. Arms. Structure shall be grouted in ratio 1:3:6 in block size 300x300x700mm and painted of welding joint with one coat of Ready Mixed primer and Two coat of enamel Aluminium paint work includes connecting neutral bushing rod of power Transformer and G.I. Earthing strip with the help of flexible copper bond, G.I. Bolt and washer. |
| 92 | Fabrication and erection of cable support made of two pieces of G.I. Angle (65x65x6)mm, 2.75 meter long, joined to each other by means of 5 Nos. G.I. Flat (50x6) mm pieces of size 750 mm long each by welding at equal intervals and grouting in a block of size (300x300x700)mm in C.C. 1:3:6 (cement, coarse sand and stone ballast) complete and painted of welding joint with one coat of Ready Mixed primer and Two coat of enamel Aluminium paint. Work includes providing of three Nos. G.I. clamps made of (50x6)mm G.I. Flat for holding the cable including nuts and bolts. |
| 93 | Properly Control Cable connections for OTI, WTI, PRV,33 KV Breaker, 33KV CT, 33KV PT, Single/Double Control & Relay pannel Buck holz relay & All Control and relay penal should be operate in auto mode. |
| 94 | H.T. Power Cable Laying (11 KV 3X300sqmm): /(33 KV 3X300 sqmm) Laying 11 KV/33 KV, (3x300) mm2 XLPE, Cable from 33 KV Bus bar to Bus Isolator & Power transformer to 11 KV incoming switch gear in the cable trench 0.45 m wide, 0.90m depth. Providing 150 mm local sand for cushion beneath and 150 mm above the cable (quality of local sand required 0.375 cum/m in length). The cable shall be dully protected by brick. On both side of cable by laying brick vertically and bricks would also be laid bricks along the single cable (minimum 18 Nos. of bricks are to be laid top and outer side along the single cable. The work includes digging of trenches, laying of cable in under ground trenches, joining of terminal’s, back filling of earth and testing and commissioning of power cable etc. Spare cable shall be left over and laid in the trenches in shape of 6 m ring at both ends. |
| 95 | Cable Laying (11 KV 3X185sqmm): Laying 11 KV, 3x185mm2 XLPE, Power cable from outgoing switch gear to 11 KV double poles in the cable trench 0.50m wide, 0.90m depth. Providing 150 thickness mm local sand for cushion beneath and 150mm above the cable (quantity of local sand required 0.375 cubm/m in length). The cable shall be duly protected by brick. On both side of cable by laying bricks vertically and bricks would also be laid horizontally on top of vertically laid bricks along the single cable (minimum 18 Nos. of bricks are to be laid top and outer side along the single cable. The work includes digging of trenches, laying of cable in under ground trenches, joining of terminal’s, back filling of earth and testing and commissioning of power cables etc. Spare cable shall be left over and laid in the trenches in shape of 6m rings at both ends. At the end of feeder cables, where the cable is to be laid across pucca/main road, 100 mm dia G.I. pipe will be weared over the cable in the cable trench for the protection of cable. |
| 96 | Preparation of 33 KV/11 KV Power Cable Jointing Kits: Making of 33KV/11 KV XLPE Heat shrinkable outdoor jointing kits 3x185Sq.mm/3x300Sq.mm/3x70Sq.mm after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs |
| 97 | Laying of Control Cables (2x2.5)mm2/ (4x2.5)mm : Laying of different size of (2x2.5)mm2/ (4x2.5)mm2 control cables i.e. from Buchholz realy to Marshalling box Marshalling box to indication protection board in switch gear room, 33 KV CT’s to CT’s Junction Box, 33 KV CT, 33 KV PT, V.C.B. Control Panel Junction Box to 33 KV VCB control panel and control panel to 33 KV VCB outdoor operating mechanism panel from T/F etc. in the cable trench including making proper connection at Buchholz Relay, Marshalling box and indication board as per required for installed equipment. |
| 98 | Providing & wearing of 160 mm dia, 6.0 mtr long G.I. pipe in the feeder cable & 33KV/11 KV Cable of size of (3x300, 3x185)mm2 XLPE 33KV/11KV power cable before making the outdoor cable boxes. The work includes the sealing of G.I. Pipe, top end and lower end of the pipe is to be buried in to the ground about ½ m and proper dressing of cable etc. The work includes lifting, mounting and clamping of 11 KV feeder cable boxes on the feeder with double pole structure and making connections including supply of cable mounting clamps etc. |
| 99 | Painting of Structures : Painting of the all structures with one coat of ready mixed primer and two coats of ISI Mark Aluminium paint after rubbing with sand paper to the surface of the structure including labour and T&P complete in all respect. |
| 100 | Installation of 33 KV Isolators: Assembling and installation of Bus Isolator on the isolator structure. Adjusting of operating mechanism in proper alignment so as to ensure smooth operation of the same. In case of Line Isolator proper operation of earth links shall also be ensured. The work includes complete with earthing and line connections & fabrication for proper fixing if required. |
| 101 | Installation of 33 KV Lightning Arrestors: Assembling and installation/mounting of 3 Nos. lighting arrestors on the L.A.’s structure/terminal gentry, complete with earthing and line connections. The work includes fabrication for proper fixing, if required. |
| 102 | Installation of 33 KV Post Insulators: Installation of 6 Nos. PI on each structure. The work includes complete with earthing and line connections & fabrication for proper fixing, if required. |
| 103 | Installation of 33 KV Fuse Set: Assembling and installation of fuse set on the fuse set structure. The work includes complete with earthing and line connections & fabrication for proper fixing, if required. |
| 104 | Installation of 33 KV VCB : Assembling and installation of 33 KV VCB on the VCB out door structure on the plinth. Adjustment of operating mechanism in proper alignment for smooth operation of the same. The work also includes complete with earthing and line connections & fabrication of addition arrangement for proper fixing, if required. |
| 105 | Installation of 33 KV VCB Control Panel for single T/F & Double T/F Control Panel. Carefully and safely shifting of 33 KV VCB control panel from outside of the switch gear room to inside of the switch gear room, grouting with anchor bolts in the floor, work also includes cutting & proper finishing of floor if necessary for completion of work. Placing and fixing of panel on foundation, bolts of proper size in proper position and alignment. |
| 106 | Installation of 33 KV PT & C.T.’s: Installation of 3 Nos. PT & C.T.’s on the PT & C.T’s structure. The work includes complete with earthing and line connections & fabrication for proper fixing, if required to complete the work. |
| 107 | 33 KV CT’s Junction Box: Providing & fixing of junction box of size (400x400x150) mm made of G.I. sheet of 16 SWG in between 33 KV CT’s & control panel. The work also include making proper connection on the junction box and making all connection in between CT’s and control panel complete as per manufacture’s panel drawing including testing and commissioning of work etc. complete the work. |
| 108 | 33 KV Bus Bar Jumpering: Jumpering, including clamping/binding with ACSR Dog conductor/33KV 3x300mm2 XLPE cable with providing P.G.Clamp & Connector HV side of T/F and other accessories with complet Job. |
| 109 | Providing and fixing of Silica Gel Breather with pot For 5 MVA Power Transformer, OTI , WTI, HV Side Brass connectors with Nut & Bolts, LV Side Brass connectors with Nut & Bolts & Etc. |
| 110 | Painting of 05 MVA Power T/F with one coat of red oxide primer and two coat of grey colour enable paints with proper rubbing and cleaning of Power T/F |
| 111 | Oil leackage work like top cover plate, radiator, H.V. bushing & L.V. bushing any leackage of Power T/F work will be done by contrator all required materials will be provided by firms |
| 112 | Double Pole structure 11 Mtr Long SP-55/PCC 9 Mtr. Pole/8.5 Mtr. PCC Excvation Fabrication,Erection,Fixing all clamps and other accessories such as Top Channel, Dropper Channet, Cross Bracing & No plate danger board barbed wire ,painting etc with earting of supports |
| 113 | Grouting of 11 Mtr STP/PCC 8.5 Mtr. pole as per relevant drawing including cost of grouting material ratio1:4:8 (cement, sand and brick ballast ) |
| 114 | Earthing of 11 Mtr. Long PCC/8.5 Mtr. long PCC/ 11 Mtr. STP poles complete as per construction manual and drawings with G.I. Wire fitted M.S. Nut Bolt & Washer. |
| 115 | Fixing of D/P related Asseseries |
| 116 | Shifting & Re-Installation of Substation DP, Old Busbar structure & Desmentling of old Structure From Swithyard and |
| 117 | soilfelling in switchyard approx. 03 to 04 Feet. |
| 118 | INSTALLATION OF SWITCH GEARS IN CONTROL ROOM:- Errection and instalation of 11 K.V. V.C.B's (Incoming & Outgoing in aligment and connecting interconnecting bus bars and 11 K.V. cables. Total in Figures 0.0 23 Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |