Housing Urban and Rular Development Government Departments Closing in 0 days TDR #55535321

Tender For Shifting And Reconstruction Of Existing Electrical Installation Due To Impvt Such As Widening And Strengthening To Chhatia Kalakala Road From 0.00 Km To 16.393 Km In The District Of Jajpur For The Year 2026-27

Issued by Government Departments · Chhatia, Odisha
Tender Value
35.03 Lakhs
Estimated cost
Bid Submission
30 May 2026
0 days left
EMD
35100
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chhatia → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Shifting And Reconstruction Of Existing Electrical Installation Due To Impvt Such As Widening And Strengthening To Chhatia Kalakala Road From 0.00 Km To 16.393 Km In The District Of Jajpur For The Year 2026-27

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 22-May-2026 Modification in Office Memorandum regarding APS calculation in DTCN. Other 30-May-2026

BOQ

Name of Work:- Shifting and reconstruction of existing electrical installation due to impvt such as widening and strengthening to Chhatia Kalakala road from 0.00 km to 16.393 km in the district of Jajpur for the year 2026-27
Sl. No. Item Description
1PART A: Construction of 0.05 CKM 33 KV O/H line using 13 Mtr. WPB Pole & 148 Sq.mm. AAA Conductor 33 KV Cut Point with 180 Degree AngleWPB (GI) Pole 160x152 (13Mtr. Long, 30.44KG/Mtr.)(Total Pole Weight with Base Plate & Stiffner=395.72 KG+10.74 KG= 406.46 KG)
2Straight Cross Arm Channel(GI) 100 x 50 x 6 mm, 9.56 KG/mtr, each Channel(GI) length 1.7 Mtr., 2 No's of Channel(GI) = (2x 9.56x1.7)
3Fish Plate(GI) 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 8 no's required = (8x2.36x0.280)
4Straight Cross Arm Top Channel(GI) 100 x 50 x 6 mm, 9.56 KG/mtr, each Channel(GI) length 0.306 Mtr., 2 No's of Channel(GI) = (2x 9.56x0.306)
5Danger Plate, 1 no's.
6Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 1 no's = (1x0.59x0.510)
7GI barbed wire anticlimbing device 3 Kg. Per support
8Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 4 no's = (4x0.59x0.510)
933KV pin insulator polymer
10H W fitting(B&S)90KN,4 Bolt
11Disc insulator (B&S)90 KN polymer
12Earthing of Support ( Coil Type )
13No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing
14Wedge connector for 148 sq.mm AAA conductor
15GI Nut , Bolt & Washer of different sizes (4.879 Kg each 180 deg. Cut point)
16POLYCARBONATE BIRD GUARD
17Black Paint(GIS Numbering & Zebra Stripping)
18Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
19Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX2200mm) = 0.55Cu.mtr(Per Pole)
20Couping ratio 1:1.5:3(M-20 Grade) with dimension (500X500X450)= 0.1125 Cu mtr(Per Pole)
2133 KV Pin Points148 sq.mm AAA conductor
22PART B: Construction of 1.0 CKM 11 kV O/H line using 11 Mtr. WPB Pole & 80 Sq.mm. AAA Conductor11 KV Cut Point with 90 Degree AngleWPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)(Total Pole Weight with Base Plate & Stiffner=334.84 KG+10.74 KG= 345.58 KG)
23Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each Channel(GI) length 1.2 mtr., 4 no's Channel(GI) required =( 4x9.56x1.2)
24Fish Plate(GI) 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 16 no's required = (16x2.36x0.280)
25Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each Channel(GI) length 0.306 mtr., 4 no's Channel(GI) required =( 4x9.56x0.306)
26Danger Plate, 1 no's.
27Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 1 no's = (1x0.59x0.510)
28GI barbed wire anticlimbing device 3 Kg. Per support
29Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 4 no's = (4x0.59x0.510)
3011 KV pin insulator polymer
31H W fitting(B&S) 70KN, 3Bolt
32Disc insulator (B&S) 70 KN polymer
33Earthing of Support ( Coil Type )
34No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing
35WEDGE CONNECTOR FOR 80 SQMM.CONDUCTOR
36POLYCARBONATE BIRD GUARD
37H.T. Stay clamp, 50x8 mm. Flat(GI), 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)
38H.T. Stay set (Complete )
39H.T. Stay Insulator Type-C
407/10 SWG Stay Wire 15kg /stay
41GI Nut , Bolt & Washer of different sizes (7.433 Kg each Cut Pole)
42Black Paint(GIS Numbering & Zebra Stripping)
43Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
44Fixing of complete 11KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire.5)Stay clamps with Nuts & bolts BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & Standard.
45Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1800mm) = 0.45Cu.mtr(Per Pole)
46Couping ratio 1:1.5:3(M-20 Grade) with dimension ( 500X500X450)= 0.1125 Cu mtr(Per Pole)
4711 KV Pin Points With WPBWPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)(Total Pole Weight with Base Plate & Stiffner=334.84 KG+10.74 KG= 345.58 KG)
4811 KV V cross Arm(GI) (10.2 K.g. each )
49Top bracket 100x50X6 mm GI Channel(GI) (2kg each)
50Danger Plate, 1 no's. for each pole
51Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 1 no's = (1x0.59x0.510)
52GI barbed wire anticlimbing device 3 Kg. Per support
53Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 4 no's = (4x0.59x0.510)
5411 KV pin insulator polymer, 3 Nos. required for each support
55Earthing of Support ( Coil Type )
56No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing
57GI Nut , Bolt & Washer of different sizes (1.45 Kg/ Pin Point)
5880 sq.mm AAA conductor
59Crimping type Midspan Compression Joint for 80 sq.mm AAA conductor
60Black Paint(GIS Numbering & Zebra Stripping)
61Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
62POLYCARBONATE BIRD GUARD
63Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1800mm) = 0.45Cu.mtr(Per Pole)
64Couping ratio 1:1.5:3(M-20 Grade) with dimension (500X500X450)= 0.1125 Cu mtr(Per Pole)
65Part-C: Installation of 01 No of existing 11/0.433 KV, 63 KVA DTR on Proposed DP (Cost of DTR not considered, existing DTR will be used)WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)-DP(Total Pole Weight with Base Plate & Stiffner=334.84 KG+10.74 KG= 345.58 KG)
669 Mtr. long 300 Kg. PSC Pole
67Pole clamp for EYE hook for (XLPE Aerial bunched Cable)
68EYE hook for XLPE Aerial bunched Cable
69Dead End Clamp suitable for messenger XLPE Aerial bunched Cable
70LT Cable raising Channel(GI) 75x40x4.8 mm GI Channel(GI) (1000 mm long)(7.14Kg./Mtr., 3 No's.) (Each 3x1.000x7.14= 21.42 Kg)
71Top Channel(GI) GI 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)
72Fish Plate(GI) 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280)
73AB Switch Mounting Channel(GI) 75x40x4.8 mm GI Channel(GI) (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)
74AB Switch Side Support Channel(GI) 100X50X6mm,9.56 KG/Mtr., each Channel(GI) length 0.35 mtr., 2 no's Channel(GI) required =( 9.56x2x0.35)
75Channel(GI) Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each Channel(GI) length 0.8 Mtr., 1 no's Channel(GI) required =( 7.14x0.8x1)
76HG/ DO Fuse Mounting Channel(GI) 75x40x4.8 mm GI Channel(GI) (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)
77Cantilever Support Channel(GI) 75x40x4.8 mm GI Channel(GI) (810 mm long,2 No's.) (7.14Kg./Mtr., 2 No's.) (Each 2x0.810x7.14= 11.57 Kg)
78Cantilever Support Angle(GI) 50 X 50 X 6MM GI (1282 mm long) (4.5Kg./Mtr, 2 No's.) (Each 2x1.282x4.5= 11.54Kg)
79Transformer Base GI Channel(GI) 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)
80Transformer Base Support GI Channel(GI) 100 X 50 X 6 MM (515 mm long) (9.56Kg./Mtr, 2 No's) (Each 2x0.515x9.56= 9.85Kg)
81Transformer Belting Angle(GI) 50 X 50 X 6MM GI (3000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x3.0x4.5 Kg)
82Transformer Belting Support Angle(GI) 50 X 50 X 6MM GI (580 mm long)(4.5Kg./Mtr,2 No's) (Each 2x0.580x4.5= Kg)
83LTDB Mounting Angle(GI) 50 X 50 X 6MM GI (1000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x1x4.5 Kg)
8450x6mm Flat(GI) for earthing, 2.36kg/mtr., (2.5x7 mtr. For mesh formation, 12 Mtr. For LA and 2.5 mtr. For raising, 11 mtr for AB switch, 2.8 mtr for HG Fuse, 5x2 mtr. for DTR Nutral, (1.3+4.5) mtr. For DTR Body, 0.500 mtr for LTDB & AB Switch operating handle, 3 mtr. for Fencing) ( Each 65.6x 2.36= 154.81 Kg)
85LT Distribution Box with MCCB, Aluminium Busbar of single Bay with kit kat fuse for 63 KVA S/S
8655 SQ.MM. AAAC XLPE Covered Conductor
874 Cx 95 mm2 LT XLPE Cable(Armoured) - FOR 63 KVA Trf.
884 Cx 95 mm2 LT XLPE Cable(Armoured) - From LTDB to Pole
89AB Switch(11KV,200A.3pole,50Hz)
90D.O.Fuse( 11KV.200A.3Pole)
915Amp Fuse link
92WEDGE CONNECTOR FOR 55 SQMM.CONDUCTOR
93POLYCARBONATE BIRD GUARD
94Disc insulator (B&S)70 KN polymer
95H W fitting (B&S)70KN(3bolted)
96Lightning Arrester(12KV,10KA) Station Class 2
9711KV pin insulator polymer
98HT stay set complete
99HT stay Clamp (1.9Kg/pair)
100HT stay insulator TYPE-C
1017/10 SWG GI stay wire, Grade -2 (15Kg./ Set)
10240 mm Nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long
103GI Nuts & Bolts of Assorted size (25 Kg/ DSS DP)
104GI Barbed wire/Anticlimbing device (3Kg /Pole)
105Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 8 no's = (8x0.59x0.510)
106Danger plate 11kv
107Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 2 no's = (2x0.59x0.510)
108Name plate
109Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
110Black Colour Paint(GIS Numbering & Zebra Stripping) for numbering
111Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1800mm) = 0.450Cu.mtr(Per Pole) (For WPB Pole)
112Couping ratio 1:1.5:3(M-20 Grade) (500mmX500mmX450mm) = 0.113Cu.mtr(Per Pole)
113PCC ratio 1:3:6(M-10 Grade) For DSS Area (5X3X0.1)= 1.5 Cu. mtr.
114Fixing of stay set with 0.5Cum cement concrete foundation 1:3:6(M-10 Grade) size ( 900mmx600mmx900mm) using 40mm BHG metal with all labor and material except stay set , stay wire , stay insulator .
115Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI) around pipe .
116Laying of 4 Cx 95 mm2 LT XLPE Cable
117SITC and Erection of GI Fencing with Gate
118Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1500mm) = 0.375Cu.mtr(Per Pole) (For PSC Pole)
119Supply of AL Lugs suitable for 95 sq mm cable/conductor, Crimping with cable and Fixing/connecting include supply and erection of PVC Tape as per voltage requirement.
120Supply and erection of double Compression Flameproof Type Glanding for armored Cable 3.5/4C 50-95sqmm including making hole in Base plate and dressing of cable along with vermin proofing properly .Supply to be done as per TPCODL Spec and approved make dowells.
121Part-D: Installation of 01 No of existing 11/0.433 KV, 100 KVA DTR on Proposed DP(Cost of DTR not considered, existing DTR will be used)WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)-DP(Total Pole Weight with Base Plate & Stiffner=334.84 KG+10.74 KG= 345.58 KG)
1229 Mtr. long 300 Kg. PSC Pole
123Pole clamp for EYE hook for (XLPE Aerial bunched Cable)
124EYE hook for XLPE Aerial bunched Cable
125Dead End Clamp suitable for messenger XLPE Aerial bunched Cable
126LT Cable raising Channel(GI) 75x40x4.8 mm GI Channel(GI) (1000 mm long)(7.14Kg./Mtr., 3 No's.) (Each 3x1.000x7.14= 21.42 Kg)
127Top Channel(GI) GI 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)
128Fish Plate(GI) 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280)
129AB Switch Mounting Channel(GI) 75x40x4.8 mm GI Channel(GI) (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)
130AB Switch Side Support Channel(GI) 100X50X6mm,9.56 KG/Mtr., each Channel(GI) length 0.35 mtr., 2 no's Channel(GI) required =( 9.56x2x0.35)
131Channel(GI) Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each Channel(GI) length 0.8 Mtr., 1 no's Channel(GI) required =( 7.14x0.8x1)
132HG/ DO Fuse Mounting Channel(GI) 75x40x4.8 mm GI Channel(GI) (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)
133Cantilever Support Channel(GI) 75x40x4.8 mm GI Channel(GI) (810 mm long,2 No's.) (7.14Kg./Mtr., 2 No's.) (Each 2x0.810x7.14= 11.57 Kg)
134Cantilever Support Angle(GI) 50 X 50 X 6MM GI (1282 mm long) (4.5Kg./Mtr, 2 No's.) (Each 2x1.282x4.5= 11.54Kg)
135Transformer Base GI Channel(GI) 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)
136Transformer Base Support GI Channel(GI) 100 X 50 X 6 MM (515 mm long) (9.56Kg./Mtr, 2 No's) (Each 2x0.515x9.56= 9.85Kg)
137Transformer Belting Angle(GI) 50 X 50 X 6MM GI (3000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x3.0x4.5 Kg)
138Transformer Belting Support Angle(GI) 50 X 50 X 6MM GI (580 mm long)(4.5Kg./Mtr,2 No's) (Each 2x0.580x4.5= Kg)
139LTDB Mounting Angle(GI) 50 X 50 X 6MM GI (1000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x1x4.5 Kg)
14050x6mm Flat(GI) for earthing, 2.36kg/mtr., (2.5x7 mtr. For mesh formation, 12 Mtr. For LA and 2.5 mtr. For raising, 11 mtr for AB switch, 2.8 mtr for HG Fuse, 5x2 mtr. for DTR Nutral, (1.3+4.5) mtr. For DTR Body, 0.500 mtr for LTDB & AB Switch operating handle, 3 mtr. for Fencing) ( Each 65.6x 2.36= 154.81 Kg)
141LT Distribution Box with MCCB, Aluminium Busbar of 2 Bay with kit kat fuse for 100 KVA S/S
14255 SQ.MM. AAAC XLPE Covered Conductor
1434 Cx 150 mm2 LT XLPE Cable(Armoured) - FOR 100 KVA Trf.
1441.1kV, 4Core, 150 sqmm, XLPE insulation armoured -Aluminium UG cable from LTDB to Pole
145AB Switch(11KV,200A.3pole,50Hz)
146D.O.Fuse( 11KV.200A.3Pole)
14710Amp Fuse link
148WEDGE CONNECTOR FOR 55 SQMM.CONDUCTOR
149POLYCARBONATE BIRD GUARD
150Disc insulator (B&S)70 KN polymer
151H W fitting (B&S)70KN(3bolted)
152Lightning Arrester(12KV,10KA) Station Class 2
15311KV pin insulator polymer
154HT stay set complete
155HT stay Clamp (1.9Kg/pair)
156HT stay insulator TYPE-C
1577/10 SWG GI stay wire, Grade -2 (15Kg./ Set)
15840 mm Nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long
159GI Nuts & Bolts of Assorted size (25 Kg/ DSS DP)
160GI Barbed wire/Anticlimbing device (3Kg /Pole)
161Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 8 no's = (8x0.59x0.510)
162Danger plate 11kv
163Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 2 no's = (2x0.59x0.510)
164Name plate
165Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
166Black Colour Paint(GIS Numbering & Zebra Stripping) for numbering
167Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1800mm) = 0.450Cu.mtr(Per Pole) (For WPB Pole)
168Couping ratio 1:1.5:3(M-20 Grade) (500mmX500mmX450mm) = 0.113Cu.mtr(Per Pole)
169PCC ratio 1:3:6(M-10 Grade) For DSS Area (5X3X0.1)= 1.5 Cu. mtr.
170Fixing of stay set with 0.5Cum cement concrete foundation 1:3:6(M-10 Grade) size ( 900mmx600mmx900mm) using 40mm BHG metal with all labor and material except stay set , stay wire , stay insulator .
171Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earthresistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI)around pipe .
172Laying of 4 Cx 150 mm2 LT XLPE Cable
173SITC and Erection of GI Fencing with Gate
174Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1500mm) = 0.375Cu.mtr(Per Pole) (For PSC Pole)
175Supply of AL Lugs suitable for 150 sq mm cable/conductor, Crimping with cable and Fixing/connecting include supply and erection of PVC Tape as per voltage requirement.
176Supply and erection of double Compression Flameproof Type Glanding for armored Cable 3.5/4C 120-185sqmm including making hole in Base plate and dressing of cable along with vermin proofing properly .Supply to be done as per TPCODL Spec and approved make dowells.
177PART E: Installation of 01 Nos of 33 kV Road crossing guarding having span 40 Mtr. each Guarding Channel(GI) 75x40x4.8 mm, 7.14 KG/Mtr., each Channel(GI) length 2.5 mtr., 4 no's Channel(GI) required =( 4x7.14x2.5) ( For Single Pole)
178No-6 GI wire (0.192 kg/mtr.) for Main String
179No-8 GI wire (0.131 kg/mtr.) for lacing
180Eye Bolt (236mm, 16mm dia, 1.577kg/mtr.)
181Gi Pipe Earthing 40mm. 3 Mtr. Long
18250x6mm Flat(GI) for earthing, 2.36kg/mtr., (12.7 mtr For raising)= 12.7x2.36
183Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI) around pipe .
184Part:F:- 1. Installation of 4 Nos of 11 kV Road crossing guarding having span 30 Mtr. each 2. Installation of 1 Nos of LT Road crossing guarding having span 30 Mtr. each Guarding Channel(GI) 75x40x4.8 mm, 7.14 KG/Mtr., each Channel(GI) length 2.2 mtr., 4 no's Channel(GI) required =( 4x7.14x2.2) ( For Single Pole)
185No-6 GI wire (0.192 kg/mtr.) for Main String
186No-8 GI wire (0.131 kg/mtr.) for lacing
187Eye Bolt (236mm, 16mm dia, 1.577kg/mtr.)
188Gi Pipe Earthing 40mm. 3 Mtr. Long
18950x6mm Flat(GI) for earthing, 2.36kg/mtr., (10.7 mtr For raising)= 10.7x2.36
190Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI) around pipe .
191PART G: Construction of 0.3 KM LT line using 9 Mtr. PSC pole & (4C×70 mm² (P)+1C×70 mm²(M)+1CX16 mm²(Street Light) LT AB cable WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)(Total Pole Weight with Base Plate & Stiffner=334.84 KG+10.74 KG= 345.58 KG)
192H.T. Stay clamp, 50x8 mm. Flat(GI), 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)
193H.T. Stay set (Complete )
194H.T. Stay Insulator Type-C
1957/10 SWG Stay Wire 15kg /stay
1969 Mtr. long 300 Kg. PSC Pole
197LT Stay set Complete
1987/12 SWG GI stay wire, Grade -2
199LT stay Clamp ( 1.40Kg/pair)
200LT Stay insulator
201LT Accessories with Eye hook and ClampPole clamp for EYE hook for (XLPE Aerial bunched Cable)
202EYE hook for XLPE Aerial bunched Cable
203Dead End Clamp suitable for messenger XLPE Aerial bunched Cable
204Suspension Clamp with EYE hook for ABC
2054C×70 mm² (P)+1C×70 mm²(M)+1CX16 mm²(Street Light) (LT AB Cable)
2068 WAY SERVICE Distb.Box with kit kat fuse and Aluminium bus bar.
207Insulated piercing connector.Type-A-main 50 to 150 sq.mm & Tap-50 to 150 sq.mm
208GI Pipe Earthing (each 5th pole to earth)
209Coil Earthing
210No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing
211Danger plate (LT)
212Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 1 no's = (1x0.59x0.510)
213GI barbed wire anticlimbing device 3 Kg. Per support
214Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 4 no's = (4x0.59x0.510)
215GI Nut , Bolt & Washer of different sizes (0.5 Kg/ Pole)
216Black Paint(GIS Numbering & Zebra Stripping)
217Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
218Fixing of LT Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts, including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size (500mmx500mmx800mm) using 20mm BHG metal with all labour and material (Excavation of earth will be done of size 500X500X1500 mm.)
219Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1500mm) = 0.375Cu.mtr(Per Pole)
220Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1800mm) = 0.45Cu.mtr(Per Pole)
221Couping ratio 1:1.5:3(M-20 Grade) with dimension ( 500X500X450)= 0.1125 Cu mtr(Per Pole)
222Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI) around pipe .
223PART H: Construction of 0.5KM LT line using 9 Mtr. PSC pole & (4C×50 mm² (P)+1C×50 mm²(M)+1CX16 mm²(Street Light) LT AB cable (9 Mtr. long 300 Kg. PSC Pole
224LT Stay set Complete
2257/12 SWG GI stay wire, Grade -2
226LT stay Clamp ( 1.40Kg/pair)
227LT Stay insulator
228Pole clamp for EYE hook for (XLPE Aerial bunched Cable)
229EYE hook for XLPE Aerial bunched Cable
230Dead End Clamp suitable for messenger XLPE Aerial bunched Cable
231Suspension Clamp with EYE hook for ABC
2324C×50 mm² (P)+1C×50 mm²(M)+1CX16 mm²(Street Light) (LT AB Cable)
2338 WAY SERVICE Distb.Box with kit kat fuse and Aluminium bus bar.
234Insulated piercing connector.Type-A-main 50 to 150 sq.mm & Tap-50 to 150 sq.mm
235GI Pipe Earthing (each 5th pole to earth)
236Coil Earthing
237No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing
238Danger plate (LT)
239Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 1 no's = (1x0.59x0.510)
240GI barbed wire anticlimbing device 3 Kg. Per support
241Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 4 no's = (4x0.59x0.510)
242GI Nut , Bolt & Washer of different sizes (0.5 Kg/ Pole)
243Black Paint(GIS Numbering & Zebra Stripping)
244Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
245Fixing of LT Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts, including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size (500mmx500mmx800mm) using 20mm BHG metal with all labour and material (Excavation of earth will be done of size 500X500X1500 mm.)
246Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1500mm) = 0.375Cu.mtr(Per Pole)
247Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI) around pipe .
248PART I : Dismantling Portion Dismantling of 09/11 Mtr. Joist/WPB Pole- 116X100mm
249Dismantling of 9/8 Mtr. PCC/Joist Pole
250Dismantling of existing 11/0.4kV, 33/0.4KV, Three Phase Distribution Transformer 63KVA including removal of HT/LT leads, earth connections and unloading by crane if required.
251Dismantling of existing 11/0.4kV, 33/0.4KV, Three Phase Distribution Transformer below 100KVA including removal of HT/LT leads, earth connections and unloading by crane if required.
252Dismantling of ACSR/AAAC 34/ 55mm2 from overhead line
253Dismantling of ACSR/AAAC 80/100 mm2 from overhead line
254Dismantling of ACSR/AAAC 148/232mm2 from overhead line
255Dismantling of varous size of LT AB Cable Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 55535321
AUTHORITY Government Departments
TENDER VALUE 35.03 Lakhs
LAST DATE 30-05-2026
Authority
Authority Name Road And Building Department
Work Description Tender for Shifting And Reconstruction Of Existing Electrical Installation Due To Impvt Such As Widening And Strengthening To Chhatia Kalakala Road From 0.00 Km To 16.393 Km In The District Of Jajpur For The Year 2026-27
Basic Detail
Tender No SE CBT (R and B)-01/2026-27
Bidding Type Tender
Location
City Chhatia
State Odisha
Key Dates
Publish Date 22 May 2026
Submission Date 30 May 2026
Open Date 01 Jan 0001
Finance
Tender Value 35.03 Lakhs
Tender Fee 6000
EMD 35100
Exemption Not Available
Document List
498eb858-7e56-4cbb-a784-bdc032b024ab.html
BOQ_591625.xls
DTCN.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
May 30, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
May 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed

Tender Documents

Download All (ZIP) ↓
html

498eb858-7e56-4cbb-a784-bdc032b024ab.html

xls

BOQ_591625.xls

pdf

DTCN.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders