| 1 | Supply of following De-Centerlised material as per GTP Approved by Dvvnl and Erection,Installation, Commissioning of Single Pole/Double Pole of 11 KV Overhead Lines and Transformers By Completeing Following Works/Jobs As Per Respo Drawings/Estimate With all required Materials.Work Includes All Cartage, Carriage, of including Received Back Material. T&P, Raw Materials And Any Other Material/Work Which Is Required For Completion of Said Work But Not Mentioned In This Boq/Estimate. | Supply of following De-Centerlised material as per GTP Approved by Dvvnl and Erection,Installation, Commissioning of Single Pole/Double Pole of 11 KV Overhead Lines and Transformers By Completeing Following Works/Jobs As Per Respo Drawings/Estimate With all required Materials.Work Includes All Cartage, Carriage, of including Received Back Material. T&P, Raw Materials And Any Other Material/Work Which Is Required For Completion of Said Work But Not Mentioned In This Boq/Estimate. |
| 2 | STP Pole 11 Mtr. Long SP-55 | STP Pole 11 Mtr. Long SP-55 |
| 3 | STP Pole 9 Mtr. Long SP-33 | STP Pole 9 Mtr. Long SP-33 |
| 4 | PCC Pole 8.5 Mtr. Long | PCC Pole 8.5 Mtr. Long |
| 5 | LT XLPE Cable 1X400 Sq mm | LT XLPE Cable 1X400 Sq mm |
| 6 | LT ABC Cable 3X120 Sq mm | LT ABC Cable 3X120 Sq mm |
| 7 | LT XLPE Cable 3.5X240 Sq mm | LT XLPE Cable 3.5X240 Sq mm |
| 8 | LT ABC Cable 3X95 Sq mm | LT ABC Cable 3X95 Sq mm |
| 9 | ACSR Weasal Conductor | ACSR Weasal Conductor |
| 10 | 11 Kv Polymeric Disc Insulator 45 KN (T&C Type) | 11 Kv Polymeric Disc Insulator 45 KN (T&C Type) |
| 11 | 11 Kv Disc Fitting 45 KN (T&C Type) | 11 Kv Disc Fitting 45 KN (T&C Type) |
| 12 | 11 Kv Pin Insulator (Polymeric) | 11 Kv Pin Insulator (Polymeric) |
| 13 | 11 Kv Pin With Nut | 11 Kv Pin With Nut |
| 14 | 11/0.4 Kv T/F 25 KVA | 11/0.4 Kv T/F 25 KVA |
| 15 | 11/0.4 Kv T/F 63 KVA | 11/0.4 Kv T/F 63 KVA |
| 16 | 11/0.4 Kv T/F 100 KVA | 11/0.4 Kv T/F 100 KVA |
| 17 | 11/0.4 Kv T/F 250 KVA | 11/0.4 Kv T/F 250 KVA |
| 18 | 11 Kv TPMO with polymer Insulator | 11 Kv TPMO with polymer Insulator |
| 19 | 11 Kv Do Fuse Set | 11 Kv Do Fuse Set |
| 20 | Distribution Box 3 Phase (SMC) | Distribution Box 3 Phase (SMC) |
| 21 | Stay Set Complete 16X1800 mm | Stay Set Complete 16X1800 mm |
| 22 | Earthing Of Pole By Ms Earthing Rod Of 20X2500Mm | Earthing Of Pole By Ms Earthing Rod Of 20X2500Mm |
| 23 | Ms Channel (Dropper) 100X50X2028Mm (For Fuse Set) | Ms Channel (Dropper) 100X50X2028Mm (For Fuse Set) |
| 24 | Ms Top Channel (125X65X2240Mm) | Ms Top Channel (125X65X2240Mm) |
| 25 | Holding Clamps For Top Channel & Fuse Set Etc. With Bolts & Nuts | Holding Clamps For Top Channel & Fuse Set Etc. With Bolts & Nuts |
| 26 | Ms Angle 75X75X6X2028Mm With Clamp & Bolt And Nut (T/F Base) | Ms Angle 75X75X6X2028Mm With Clamp & Bolt And Nut (T/F Base) |
| 27 | Ms Channel 125X65X1300Mm (T-Off) | Ms Channel 125X65X1300Mm (T-Off) |
| 28 | T-Off Chennel Clamp | T-Off Chennel Clamp |
| 29 | Henley Type Tailless Unit Protection Cubical Panel 500 A, 650 V For 250 Kva DTR | Henley Type Tailless Unit Protection Cubical Panel 500 A, 650 V For 250 Kva DTR |
| 30 | Lt Incoming Panel With Metering Equipment & Fixing Arrangement | Lt Incoming Panel With Metering Equipment & Fixing Arrangement |
| 31 | 4 Core Lt Mcb With Box | 4 Core Lt Mcb With Box |
| 32 | Copper L-Piece 62X225X12Mm | Copper L-Piece 62X225X12Mm |
| 33 | All. Leg Long Barrel, All Size | All. Leg Long Barrel, All Size |
| 34 | LT Fuse Set With Box | LT Fuse Set With Box |
| 35 | LT Clamp With I Hook | LT Clamp With I Hook |
| 36 | Piercing Connector A Type | Piercing Connector A Type |
| 37 | Distribution Box Clamp | Distribution Box Clamp |
| 38 | Suspension Clamp | Suspension Clamp |
| 39 | Dead End Clamp | Dead End Clamp |
| 40 | Danger Baord | Danger Baord |
| 41 | Concreting Of Poles | Concreting Of Poles |
| 42 | Concreting Of Stay | Concreting Of Stay |
| 43 | Body and neutral earthing of 400 KVA transformers by digging pits 6” dia up to 3 mtr deep including inserting lowering 80mm dia G.I. and insert 50mm G.I. pipe chemical filled pipe (Pipe in pipe earthing) I.S.I. Mark B-Grade connecting with G.I. flat 50x6 mm Power Transformer to 80mm dia G.I. pipe and filling of chemical mixture around the G.I. pipe up to 3mtr. Including making of chamber. | Body and neutral earthing of 400 KVA transformers by digging pits 6” dia up to 3 mtr deep including inserting lowering 80mm dia G.I. and insert 50mm G.I. pipe chemical filled pipe (Pipe in pipe earthing) I.S.I. Mark B-Grade connecting with G.I. flat 50x6 mm Power Transformer to 80mm dia G.I. pipe and filling of chemical mixture around the G.I. pipe up to 3mtr. Including making of chamber. |
| 44 | Plinth For Size 2X2X1.5M above ground level and one. Ft. below the ground level of 9’’ after excavation of 4 earth brick ballast shall be provided and hammering will be done properly. After that a retaining wall of 9 width by first class brick in ratio 1:4 of cement and sand shall be made. The earth shall be filled up to one ft. below the top of the plinth. after this brick ballast shall be provided upto 6 from the earth level and proper hammering shall be done. One No. Jall of 12 mm. MS tore shall be fixed in the hollow of plinth and one. Ft. thick RCC in ration of cement, sand and stone ballast shall be laid on the top of the plinth. The 12 mm. thick plastering shall be done all around the plinth in 1:4 ratio of cement and sand. The contractor shall be responsible to complete the work as per direction of Supervision Engineer. It includes the cost of all material, labour, T & P, carrier etc. required for proper completion of work. | Plinth For Size 2X2X1.5M above ground level and one. Ft. below the ground level of 9’’ after excavation of 4 earth brick ballast shall be provided and hammering will be done properly. After that a retaining wall of 9 width by first class brick in ratio 1:4 of cement and sand shall be made. The earth shall be filled up to one ft. below the top of the plinth. after this brick ballast shall be provided upto 6 from the earth level and proper hammering shall be done. One No. Jall of 12 mm. MS tore shall be fixed in the hollow of plinth and one. Ft. thick RCC in ration of cement, sand and stone ballast shall be laid on the top of the plinth. The 12 mm. thick plastering shall be done all around the plinth in 1:4 ratio of cement and sand. The contractor shall be responsible to complete the work as per direction of Supervision Engineer. It includes the cost of all material, labour, T & P, carrier etc. required for proper completion of work. |
| 45 | FRP Fencing with foldable Gate hight minimum 06 feet (Rate shold be running per meter) including painting of Fencing with Red Oxide and Yellow enamel paint and with proper grouting Erection and construction of Toe-wall around the transformer plinth including making wall 9 inch wide & 30 cm. under the ground level and 30 cm. up to the ground level and making pocket Filling the concreting for grouting as per direction by supervising engineer and plastering around the wall in ratio 1:4 cement and sand (as per approved GTP). All material/labour will be arranged by the contractor. | FRP Fencing with foldable Gate hight minimum 06 feet (Rate shold be running per meter) including painting of Fencing with Red Oxide and Yellow enamel paint and with proper grouting Erection and construction of Toe-wall around the transformer plinth including making wall 9 inch wide & 30 cm. under the ground level and 30 cm. up to the ground level and making pocket Filling the concreting for grouting as per direction by supervising engineer and plastering around the wall in ratio 1:4 cement and sand (as per approved GTP). All material/labour will be arranged by the contractor. |