| 1 | Structural steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: Unit:kilogramSTEEL FREE ISSUED( S.l.No. : 10.4) Page No.: 119 - (Sl No. code 1007) Page No.: 324 |
| 2 | Providing asbestos cement 6 mm thick corrugated sheets roofing and fixing with polymer coated J, or L hooks, bolts and nuts 8mm dia. G.I. plain and bitumen washers complete excluding the cost of purlins, rafters and trusses: corrugated sheets :Upto 60 degrees pitch Unit:sqmAsbestos cement sheet shall be issued free by BHEL.( S.l.No. : 12.10.1) Page No.: 137 - (Sl No. 0200) Page No.: 5 |
| 3 | Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. :150 mm diameter pipes Unit:metre( S.l.No. : 13.86.4) Page No.: 154 |
| 4 | Painting with aluminium paint of approved brand and manufacture to give an even shade . :Two or more coats on new work Unit:sqm( S.l.No. : 13.95.1) Page No.: 155 |
| 5 | Refixing old glass panes with putty and nails Unit:sqm( S.l.No. : 14.10) Page No.: 158 |
| 6 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead. Unit:kg.( S.l.No. : 15.18) Page No.: 168 |
| 7 | Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 metres lead of: :G.S. Sheet Unit:sqm( S.l.No. : 15.28.1) Page No.: 169 |
| 8 | Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 metres lead of: :Asbestos sheet Unit:sqm( S.l.No. : 15.28.2) Page No.: 169 |
| 9 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead ::150 mm dia pipe Unit:metre( S.l.No. : 15.42.3) Page No.: 171 |
| 10 | FIXING OF AVAILABLE PROFILED GALVALUME SHEETING AND FLASHING IN ROOFS/CLADDING FOR ALL HIGHT AS REQUIRED BY MEANS OF GALVANIZED SELF DRILLING SELF TAPPIING FASTENERS (12-14X55 WITH EPDM SEALS) AT RECOMMENDED SPACINGS FOR ALL HEIGHTS IN WORKSHOPS AND BUILDINGS INCLUDING ALL REPAIR/RECTIFICATION(CLOSING OF HOLES ETC.) REQUIRED WHEREVER AND CARTAGE OF ALL SHEETS TO SITE PROVIDED FREE OF COST AT DESIGNATED STORE COMPLETE AS PER DIRECTION OF ENGINEER IN CHARGE. |
| 11 | Erection of fabricated materials including assembling, alignment, cutting, welding, drilling, bolts, nuts, washers etc. and cartage upto erection sites (welding transformer, electrodes, gases, power supply will be issued at BHEL stores free of cost). |
| 12 | PROVIDING REINFORCED BY ORGANIC FIBRES AND/OR INORGANIC SYNTHETIC FIBRES CEMENT 6 MM THICK CORRUGATED SHEETS (AS PER IS: 14871) ROOFING UP TO ANY PITCH AND FIXING WITH POLYMER COATED J, OR L HOOKS, BOLTS AND NUTS 8 MM DIA.G.I. PLAIN AND BITUMEN WASHERS OR WITH SELF DRILLING FASTENER AND EPDM WASHERS ETC. COMPLETE (EXCLUDING THE COST OF PURLINS, RAFTERS AND TRUSSES), INCLUDING CUTTING SHEETS TO SIZE AND SHAPE WHEREVER REQUIRED. |
| 13 | Supply and Fixing of profiled sheeting 1000-1020 mm cover width, 28 -30 mm high 5 to 6 crests manufactured out of hi-tensile BARE Aluminium zinc alloy coated high tensile steel sheet (AZ-150 gsm. Aluminium –Zinc alloy metallic coating of total both sides 550 Mpa yield stress). The minimum Basic Material Thickness (BMT) should be 0.47 mm and TCT should be 0.50 mm . The sheet shall have wide pans with required nos. of small stiffening ribs for effective water shedding and special male/female ends with full return legs on side laps for purlin support. The male end of the sheet shall have anti-capillary flute at side laps to prevent leakages. The sheet shall be fixed by means of Galvanised selfdrilling self-tapping fasteners (12-14x55 with EPDM seals). The sheet shall be supplied in lengths maximum upto 6-12 Mtrs long to suit site dimensions. |
| 14 | FABRICATION OF M.S. STEEL GUTTER/RAIN WATER PIPE USING MS SHEET OF THICKNESS 2MM OR MORE IN REQUIRED PROFILE AS PER DRAWING INCLUDINGINCLUDING BENDING IN REQUIRED SHAPE, CUTTING, WELDING, GRINDING OF ALL WELDING JUNCTION/ JOINTS ETC AND FINALLY PAINTING ONE COAT OF RED OXIDE ZINC CHROMATE PRIMER PAINT OF APPROVED MAKE INCLUDING CARTAGE OF MATERIAL SUCH AS MS SHEET FROM STORE TO WORKING SITE, LABOUR, T&P ETC. REQUIRED FOR PROPER COMPLETION OF THE WORK (STEEL, WELDING ELECTRODES, GASES ETC. WILL BE SUPPLIED FREE OF COST.). NOTE: - THE ITEM DOES NOT INCLUDE THE ERECTION FOR THE SAME AND SHALL BE PAID SEPARATELY. |
| 15 | PROVIDING AND FIXING OF 3MM THICK ONE SIDE CLEAR EMBOSSED PROFILED TRANSPARENT POLYCARBONATE SHEET WITH UV RESISTANT HAVING SUITABLE PROFILE MATCHING TO THE ROOFING & CLADDING SHEETS WITH SUITABLE FASTENERS COMPLETE AS PER THE DIRECTION OF ENGINEER I/C. |
| 16 | Fabrication and fixing MS grills, railings or required pattern in wooden frame or grouted in cement concrete with MS flat, square or round bars or angles etc. including all nuts, bolts or screws, priming coat etc. complete including cartage at site of work. (Steel will be supplied free of cost at BH |
| 17 | CLEANING OF AC/STEEL/GI ROOF SHEETING CRANE GIRDER TOP, PLATEFORMS, GUTTERS/DRAIN PIPES INCLUDING ALL TOOLS AND TACKLES REQUIRED FOR CLEARING AND DISPOSAL UP TO 2 KM OF DUST/RUBBISH ETC.GENERATED/COLLECTED DURING CLEARING PROCESS, COMPLETE IN ALL RESPECT AS PER DIRECTION OF ENGINEER INCHARGE. |
| 18 | PROVIDING & APPLYING 'COLD APPLIED BITUMINOUS COMPOUND WITH MINERAL FILLERS', KNOWN AS \\"TARPLASTIC\\",CONSUMPTION @ AVERAGE 500 GM FOR REPAIR OF EACH POINT OF AC/ MS RAIN WATER PIPE/ GUTTER JOINT AT ALL HEIGHT UPTO 40.0 M FROM FLOOR INCLUSIVE WITH ALL NECESSARY ARRANGEMENT LADDERS, T&P, SAFETY PEPS AND LABOUR AFTER CLEANING THE SURFACE BY WAY OF REMOVING OLD WORN OUT PROTECTIVE LAYERS, DUST CLOGS, LOOSE PARTICLES, BROKEN GLASSES ETC. AND EXPOSING THE MOTHER SURFACE. NOTE : MEASUREMENT SHALL BE BASED ON NO. OF PIPE/ GUTTER JOINT POINT TREATED Please Enable Macros to View BoQ information |