| 1 | Attending Electrical Faults of LT/MV electrical system comprising of LT/MV Service connection line, Feeder panel, Main Distribution panel, MCB DBs, Riser mains etc. on need basis by deputing qualified and trained/skilled technician having valid Electrical License of appropriate voltage and making arrangements for checking, testing with suitable testing devices, fault finding, replacing faulty MCBs/Isolators/Switches/lamps/holders etc. by new ones (cost of materials are not included in the scope of this item and will be paid separately) and restoration of the Power supply to the Telephone Exchange/Admin Bldg/BTS/Staff Quarters complex within reasonable time period etc. complete as required.(a) Distance up to 25 Kms from Sambalpur |
| 2 | (b) Distance above 25 Kms and up to 100 Kms from Sambalpur |
| 3 | (c) Distance above 100 Kms and up to 200 Kms from Sambalpur |
| 4 | Liaison with the Electricity DISCOMs for taking shutdown of LT/MV lines for checking, testing and replacement of faulty Service connection cable/Energy Meter/ Meter box/Feeder panel etc. and re energization of power supply after replacement of faulty components as above / removal of faults etc. complete as required. |
| 5 | Supply and fixing of SMC Junction box of size 200mm x 140mm x 95mm (inside dimensions) with hinged door type including supply and fixing of 1no. 4 pole stud connector with nuts and bolts etc. as required. (Sintex GSJB2014/SS) |
| 6 | Supplying & fixing of following items i/c connections with copper cond. cable i/c tesing, checking etc. as reqd.(M/s Philips / Havells / Bajaj ). a) 63A TPN SDFU Mainswitch W/o Sheet Steel Enclosure |
| 7 | 63 Amp. 4 pole on load type change over switch. W/o SS |
| 8 | Providing Enclosure for above Changeover / Main Switch |
| 9 | 40W 4'ft Fluorecent Tubelight |
| 10 | 18/20 W LED tube with single / Double side connection |
| 11 | 40W Electronics Choke (M/s Philips/ Surya or SS Make) |
| 12 | 4 way connector terminal |
| 13 | 6-32Amp SP MCB |
| 14 | 6-32Amp TP MCB |
| 15 | 2Way SPN MCB DB |
| 16 | 40 watt tube light starter |
| 17 | 6-63 Amp. HRC fuse DIN type |
| 18 | 6-63 Amp. HRC fuse bolted type |
| 19 | 40/63/100 Amp. 4pole isolator |
| 20 | 15/20W LED O/d Street light (IP65/ISI) (02Year Warrenty) |
| 21 | 30W LED O/d Street light (IP65/ISI) (02Year Warrenty) |
| 22 | 9/10W LED Bulb |
| 23 | Brass / PVC / Batten / angle holder |
| 24 | 10 Sq.mm FR PVC insulated copper conductor cable. |
| 25 | 1.5 Sq. mm FRLS PVC insulated, copper conductor |
| 26 | S/Making socketing with proper punching (10Sq.mm to 50Sq.mm) |
| 27 | Extention board with 03nos. 06Amp switch & Socket as reqd. |
| 28 | 100A Porcealin Kit Kut |
| 29 | Supplying, installation, testing & commissioning of 1200mm 220V, 1Ph., 50Hz. Celing fan with copper motor including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 30 | Repairing of Celing fan / Exhaaust fan, servicing, replacement faulty items etc. complete as per following (a) Overhauling of Ceiling Fan / Exhaust fan i/c dismantling, greasing of bearings, refitting, testing etc. as required. |
| 31 | Rewinding of 1200mm Ceiling fan as per original sample & specs. / speed, heat varnishing etc. complete as required. |
| 32 | Rewinding of 300mm Exhaust fan as per original sample & specs. / speed, heat varnishing etc. complete as required. |
| 33 | Rewinding of 380mm Exhaust fan as per original sample & specs. / speed, heat varnishing etc. complete as required. |
| 34 | Rewinding of 450mm Exhaust fan as per original sample & specs. / speed, heat varnishing etc. complete as required. |
| 35 | Bearings for fans (6201 & 6202) etc. as required. (Make: SKF/SS) |
| 36 | Capacitor for fans (2.5mfd to 5mfd) etc. as required. (Make: SKF/SS) |
| 37 | Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE aluminium conductor power cable of 1.1 KV grade of following core & Size size on wall / surface / Duct etc. as required. (a) 4x16Sq.mm Cable |
| 38 | 31/2 x 25Sq.mm Cable |
| 39 | Replacement of damaged feeder pillar with a newly fabricated one of size 450mm x 350 mm x250 mm deep made having 16 SWG MS sheet, duly powder coated with superior quality enamel paint after one coat of red oxide paint to accommodate one no SDFU (Excluding cost of spare)i/c providing angle iron mounting structure for support etc i/c grouting etc complete as required . |
| 40 | Supply of Hot pressed molded SMC Junction box, hinged double door type of following sizes suitable for application for fixing Electrical controls /switch gears/meters etc. with provision for cable entry/exit from bottom/side , locking arrangements including supply and fixing of 2nos 4 pole stud connectors, interconnections with suitable size single core PVC insulated copper conductor cable with copper sockets/lugs including fixing on existing pole / existing MS/GI angle stands etc. complete as required. (a) Size not less than 650mmX350mmX250mm (inside dimensions) (Make-Sintex model: SINTEX JB-6535/SS) |
| 41 | Size not less than 400mmX300mmX190mm (inside dimensions) (Make-Sintex model: SINTEX JB-4030/SS) |
| 42 | Making suitable angle base frame made of 40mmX40mmX5mm MS angle for installation of mentioned SMC junction / meter boxes , cutting, welding, fabricating, grouting the same on ground with required PCC work complete as required. |
| 43 | Replacement of faulty, burnt out and unserviceable exhaust fans by new one of a complete set 380mm /15\\" heavy duty 1400 RPM Exhaust Fans, capacitor start and run type, continuously rated, totally enclosed suitable for operation on 230 volts single phase 50 HZ AC supply, connection and testing etc. complete as required. (Make- Almonard HD (ISI) /Crompton Greaves) |
| 44 | Replacement of faulty, burnt out and unserviceable exhaust fans by new one of a complete set 300mm /12\\" heavy duty 1400 RPM Exhaust Fans, capacitor start and run type, continuously rated, totally enclosed suitable for operation on 230 volts single phase 50 HZ AC supply, connection and testing etc. complete as required. (make: Almonard model – 380/15” H/D). (Make- Almonard HD (ISI) /Crompton Greaves) Please Enable Macros to View BoQ information |