| 1 | M & L for Fully automatic star delta starter with single phase preventor for up to 20 HP pump complete including taking down old cable any make suitable for exting panel /Make, complete all as specified and directed. |
| 2 | M & L dol starter with single phase preventer for monoblock pump set up to 5 HP capacity complete including taking down old cable any make suitable for exsting panel /make, complete all as specified and directed. |
| 3 | M& L for digital soft starter 70 HP, capacity complete any make suitable for exsting panel /make, including taking down old cable cat part CSX 055 41 in L & T or Equivalent, complete all as specified and directed. |
| 4 | S&F in repair 2000 ltr capacity rotational moulded polyethelene water storage tank cynlindrical vertical with closed top Tripled layered, white colour (inside & outside of tank), hoisted and fixed in position including float valve of suitable size, complete all as specified and directed. |
| 5 | S&F in repair 1000 ltr capacity rotational moulded polyethelene water storage tank cynlindrical vertical with closed top Tripled layered, white colour (inside & outside of tank), hoisted and fixed in position including float valve of suitable size, complete all as specified and directed. |
| 6 | S&F in repair 500 ltr capacity rotational moulded polyethelene water storage tank cynlindrical vertical with closed top Tripled layered, white colour (inside & outside of tank), hoisted and fixed in position including float valve of suitable size, complete all as specified and directed. |
| 7 | Supply and fix sluice valve confirming to IS 14846 : 2000 CI body SS Spindle PN 1.6 ISI mark flanged ends for 80 mm bore pipe fixed with GI nuts, bolts, washers, rubber gaskets, etc including dismantling/taking out old unserviceable sluice valve, complete all as specified and directed. |
| 8 | All as per item No. 7 above but 100 mm dia bore. |
| 9 | All as per item No. 7 above but 150 mm dia bore. |
| 10 | Supply and fix butterfly valve confirming to IS 13095:1991, CI body, PN 1.6 ISI mark, flanged end for 80 mm bore pipe fixed with GI nut, bolts, washers, rubber gasket etc including dismantling/taking out old unserviceable valve, complete all as specified and directed. |
| 11 | Supply and fix non return valve, confirming to IS 5312:2004, CI body, for 150 mm dia bore pipe, ISI marked, flanged both ends, PN 1.6 rating, fixed with GI nuts, bolts, wahsers, rubber gasket etc including dismantling / taking out old unserviceable valve, complete all as specified and directed. |
| 12 | All as per item No. 11 above but 100 mm dia bore. |
| 13 | All as per item No. 11 above but 80 mm dia bore. |
| 14 | All as per item No. 11 above but 50 mm dia bore. |
| 15 | Supplying, laying, testing & commissioning of LT under ground XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volt grade 3.5 core X 70 sqmm laid in ducts fixed with saddle & clamps or passing through pipes complete with brass compression gland & proper lugs, nuts, bolts, washers completed including taking down old, complete all as specified and directed. |
| 16 | Supplying, laying, testing in repair FR multistranded single core copper Three run conductor of size 6 Sqmm PVC sheathed un-armoured,1100 volt grade, with RYB laid in floors/ducts or walls fixed with saddle & clamps or passing through pipes/flexible pvc pipe in concealed wiring complete with brass thimbles/lugs, nuts, bolts, washers, complete all as specified and directed. |
| 17 | Supplying, laying, testing in repair FR multistranded single core copper Three run conductor of size 10 Sqmm PVC sheathed un-armoured, 1100 volt grade, with RYB laid in floors/ducts or walls fixed with saddle & clamps or passing through pipes/flexible pvc pipe in concealed wiring complete with brass thimbles/lugs, nuts, bolts, washers, complete all as specified and directed. |
| 18 | Supplying, laying, testing in repair FR multistranded single core copper Three run conductor of size 16 Sqmm PVC sheathed un-armoured, 1100 volt grade, with RYB laid in floors/ducts or walls fixed with saddle & clamps or passing through pipes/flexible pvc pipe in concealed wiring complete with brass thimbles/lugs, nuts, bolts, washers, complete all as specified and directed. |
| 19 | Taking up/down Old unserviceable GI pipe 15 mm obre with all fittings from trenches / ducts / walls / floors / ceilings, complete all as specified and directed. |
| 20 | Supply and fix in GI pipes medium grade 15mm bore with all fittings / GI bends laid in trenches, complete all as specified and directed. |
| 21 | Supplying, laying, testing & commissioning of LT under ground XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volt grade 3.5 core X 35 sqmm laid in ducts fixed with saddle & clamps or passing through pipes complete with brass compression gland & proper lugs, nuts, bolts, washers completed including taking down old cable, complete all as specified and directed. |
| 22 | M&L testing Compact Motor Protection MM 10 relay for Medium & Large Size Motors Relay a microprocessor based Motor Protection Relay with 4 digits LED Display, Protections for Thermal Overload with Warning , Short Circuit, Under Current, Unbalance, Phase Loss, Phase Sequence Reversal, Earth Fault, Prolong Starting, Locked Rotor and Features of 4 Digit LED display, Measurement of RYB, Zero Sequence current and Thermal capacity, Separate LED’s for indication of Motor operational, Trip & Thermal OL/ pre-alarm, 2 nos, 1 no. Programmable Binary input for remote operation of C/O output contacts status, Programmable thermal OL time constant right from 1 sec to 40 sec, configured for operations of Trip Reset, Instant Tripping, Relay testing facility, Trip data recording Fault current or cause of last trip is displayed including suitable size current transformer for functioning motor pump, complete including taking down old, complete all as specified and directed by Engineer in charge. Make - L & T cat part no MM10240E005 / Havells / Indo Asian. |
| 23 | Supply and fixing in repair LED indicator suitable motor panel (RYB) type, complete all as specified and directed. |
| 24 | Supply and fixing in repair digital Ampmeter 0 to 100 Amps suitable motor panel (RYB) type, complete all as specified and directed. |
| 25 | S&F in repair Thermal over load relay ML type 14-32 A, complete all as specified and directed. |
| 26 | S&F in repair Thermal over load relay MN type 30-50 A, complete all as specified and directed. |
| 27 | S&F in repair MCCB's 3 Phase (TP) 200A 50Hz, 36 KA fixed in existing panel board, complete all as specified and directed. |
| 28 | S&F in repair MCCB's 3 Phase (TP) 100A to 160 A 50Hz, 30 KA fixed in existing panel board, complete all as specified and directed. |
| 29 | S&F in repair MCCB's 3 Phase (TP) 63A 50Hz, 30 KA fixed in existing panel board, complete all as specified and directed. |
| 30 | S&F in repair MCCB's 3 Phase (FP) 200A 50Hz, 36 KA including suitable size sheet metal enclosure, complete all as specified and directed. |
| 31 | S&F in repair Changover switch 125 Amps, 415 Volts, 4 Pole with sheet meta enclosure / existing panel board, complete all as specified and directed. |
| 32 | S&F in repair Changover switch 200 Amps, 415 Volts, 4 Pole with sheet meta enclosure / existing panel board, complete all as specified and directed. |
| 33 | Supplying, Installing, erecting commissioning and testing in repair LT indoor electric control panel board of cabinet type, dust & vermin proof of approved design comprising of CRCA sheet 1.6 mm having following features including dismantling old LT panel, removing from site, demolition of old foundation and making good complete all as specified and directed :-For Incoming :-(a) 01 No – MCCB 4 POLE, 35 KA 415V Capacity 160 Amp (35KA) DH series(b) 01 No – Voltmeter (0-500V) with selector switch(c) 01 No – Ammeter (0-300Amps) with selector switch(d) 01 Set – Pilot lampFor Outgoing :-(a) 01 No - Copper busbar of capacity 240 amp for each phase & neutral(b) 04 Nos - MCCB, TP (25KA) of 63 Amps capacity(c) 01 No - MCB TP 20 Amp(d) 02 Nos - Fully automatic star delta starter with single phase preventor for 30 HP pump..(e) 02 Nos - Fully automatic star delta starter with single phase preventor for 20 HP pump.(f) 5 Nos - Ammeter (0-100 Amps) with selector switch(g) 02 Nos - Caution board(h) All internal wiring suitable size FRLSH copper conductor, fuses, glands and connected necessary switchgears.(j) The panel made out of CRCA sheet duly painted with synthetic enamel paint 7 baked in oven, necessary angle iron of size 40x40x6 mm for grouting, PCC foundation etc complete all as specified and directed by the Engineer-in-charge. |
| 34 | Supplying, Installing, erecting commissioning and testing in repair LT indoor electric control panel board of cabinet type, dust & vermin proof of approved design comprising of CRCA sheet 1.6 mm having following features including dismantling old LT panel, removing from site, demolition of old foundation and making good complete all as specified and directed :-For Incoming :-(a) 01 No – MCCB 4 POLE, 35 KA 415V Capacity 250 Amp DH series(b) 01 No – Voltmeter (0-500V) with selector switch(c) 01 No – Ammeter (0-300Amps) with selector switch(d) 01 Set – Pilot lampFor Outgoing :-(a) 01 No - Copper busbar of capacity 375 amp for each phase & neutral(b) 02 Nos - MCCB, TP (25KA) of 160 Amps capacity(c) 01 No - MCB TP 20 Amp(d) 03 Nos - Digital soft starter , cat part CSX 055 41 in L & T or Equilelnt (e) 02 Nos - 3 Pole power contactors of type ML-4 in L&T or Equiulent (f) 01 Nos - Dol starter with single phase preventer for monoblock pump set 5 HP capacity L &T (g) 3 Nos - Ammeter (0-100 Amps) with selector switch(h) 02 Nos - Caution board(j) All internal wiring suitable size FRLSH copper conductor, fuses, glands and connected necessary switchgears.(k) The panel made out of CRCA sheet duly painted with synthetic enamel paint 7 baked in oven, necessary angle iron of size 40x40x6 mm for grouting, PCC foundation etc complete all as specified and directed by the Engineer-in-charge. |
| 35 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 36 | S&F Mild steel Joist, channel, angle or tee sections, fixed independently, without connecting plates etc, (cut to ordinary length of Fe 410-W-(Gde-E-250) quality-A, for making ladder of OHT tanks, complete all as specified and directed. |
| 37 | S&F Mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment including preparation of surfaces and applying one coat of primer and two coats of synthetic enamel paint, complete all as specified and directed. |
| 38 | Demolition of Concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 39 | M&L for PCC type B-2 (1:2:4) using 40 mm graded stone aggregate in foundation, filling and mass concrete as in motor foundation, complete all as specified and directed. |
| 40 | Demolition of brick work or stone/boulder masonary built in cement mortar or cement lime mortar including all quoins, complete all as specified and directed. |
| 41 | M & L brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete at various locations, complete all as specified and directed. |
| 42 | M&L for renderting 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, complete all as specified and directed. |
| 43 | Supply and fixing Battery 12 V 180 AH model No XP 1800 including taking down old of exide or equivalent, complete all as specified and directed. |
| 44 | Supply only pad lock 50 mm dia with minimum double key, seven lever, made out of hardened brass and rust restistant internal components, complete all as specified and directed. |
| 45 | S&F in repair pressure gauge 150 mm dia range 0-10 kg/Sqcm, complete all as specified and directed. Make : FIEBIG or equivalent.Note : Rate quoted deemed to be included for providing adopter/Ferrule/check nut etc required for fixing of pressure gauge. |
| 46 | Supplying, Installing, erecting commissioning and testing in repair LT Outdoor electric control panel board of cabinet type, dust & vermin proof of approved design comprising of CRCA sheet 16 guage having following features including dismantling old LT panel, removing from site, demolition of old foundation and making good complete all as specified and directed :For Incoming :-(a) 01 No – MCCB 4 POLE, 35 KA 415V Capacity 63 Amp (35KA) DH series(b) 01 No – Voltmeter (0-500V) with selector switch(c) 01 No – Ammeter (0-300Amps) with selector switch(d) 01 Set – Pilot lampFor Outgoing :-(a) 01 No - Copper busbar of capacity 100 amp for each phase & neutral(b) 02 Nos - MCCB, TP (25KA) of 63 Amps capacity(c) 02 Nos - Fully automatic star delta starter with single phase preventor for 20 HP pump.(d) 2 Nos - Ammeter (0-100 Amps) with selector switch(e) 02 Nos - Caution board(f) All internal wiring suitable size FRLSH copper conductor, fuses, glands and connected necessary switchgears.(g) The panel made out of CRCA sheet duly painted with synthetic enamel paint 7 baked in oven, necessary angle iron of size 40x40x6 mm for grouting, PCC foundation etc complete all as specified and directed by the Engineer-in-charge. |
| 47 | Supply and fixing in repair Voltmeter/ Ampmeter digital type of showing reading 0 to 500 Amps/volts suitable motor panel (RYB) type, complete all as specified and directed. |
| 48 | Supply and fixing in repair Copper busbar of capacity 150/240 amp for each phase & neutral suitable size insulator, nut , bolts motor panel (RYB) type, complete all as specified and directed. |
| 49 | M & L for cleaning of fire chamber / Valve Chamber in area and remove all debris / plastic etc from chamber and throughout outside of army area and painting of chamber plate red / Black colour including transport carrying debris, complete all as specified and directed. |
| 50 | S&F in repair main contactor ML 4, 3 Pole of Make L&T or equivalent, complete all as specified and directed. |
| 51 | All as per items No. 50 but ML 3, 3 Pole of Make L&T or equivalent, complete all as specified and directed. |
| 52 | All as per items No. 50 but MNX 70, 3 Pole of Make L&T (Cat Part No.ST19002) or equivalent, complete all as specified and directed. |
| 53 | Supply, fixing and testing altoch dozing system model No ADS-PRO including branch connection with all connecting material, Suitable size pipes, electric connection etc complete including taking down old, complete all as specified and directed. |
| 54 | Supply only chlorine refill casul Stequa 411 AE Refil including taking down old, complete all as specified and directed. |
| 55 | Supply only Alum Crystal required for disinfection/ treatment of water, complete all as specified and directed. |
| 56 | Supply only bleaching powder required for disinfection/ treatment of water, complete all as specified and directed. |
| 57 | Supply only TCC 90 required for disinfection/ treatment of water, complete all as specified and directed. |
| 58 | Supply only Copper sulphate required for disinfection/ treatment of water, complete all as specified and directed. |
| 59 | Supply only Soda ash required for disinfection/ treatment of water, complete all as specified and directed. |
| 60 | Supply only Calcium based high strength chlorine granuals to maintain Chlorine 1 ppm, complete all as specified and directed. |
| 61 | M & L and replacement for Earthing complete with GI earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.50 mtr below normal ground level connected to GI earth lead strip 32 x 6 mm dia by means of GI bolts, nuts, check nuts, washers made out of GI/steel, all as shown on electrical plate No3 of MESschedule part-I, earth lead strip connected to indicated position including concrete pit in PCC (1:3:6, C-1),Precast RCC cover slab 55 cm x 55 cm x 5 cm with reinforcement of 8 mm dia bar 100 mm c/c bothways including one handle made of 12 mm dia MS bar embedded in pre cast slab and 20 mm bore galvanised iron pipe\\"medium grade\\" for watering with GI funnel and wire mess including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil complete all as specified and as directed and testing on completion, complete all as specified and directed. |
| 62 | Material and labour for earth continuity conductor or main earthing lead 32 x 6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 6mm dia galvanised iron or steel wire complete including taking down old cable, complete all as specified and directed. |
| 63 | Material and labour and fixed in repair for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw, complete all as specified and directed. Please Enable Macros to View BoQ information |