| 1 | Taking out old copper cable and S&F in Copper cable of size 25 sqmm single core, 440 Volt 50 Hz,draw in PVC conduit of including taking out old cable, complete all as specified and directed. |
| 2 | Taking out old copper cable and S&F in Copper cable of size 35 sqmm single core, 440 Volt 50 Hz,draw in PVC conduit not less than 25 mm including taking out old cable, complete all as specified and directed. |
| 3 | Taking out old copper cable and S&F in Copper cable of size 50 sqmm single core, 440 Volt 50 Hz,draw in PVC conduit not less than 25 mm including taking out old cable, complete all as specified and directed. |
| 4 | Taking out old UNSV Foot valve any size and S&F foot valve Cast iron body flange type ISI marked including nut, bolt all connected fitting including taking down old foot valves complete all as specified and directed of following sizes :- |
| 5 | (a) 80mm |
| 6 | (b) 100mm |
| 7 | (c) 150 mm |
| 8 | (d) 200 mm |
| 9 | Taking out old UNSV Starter and S&F in replacement automatic starter of star delta in sheet metal enclosure type, wall mounting suitable for centrifugal pump /submercible pump/monoblock pump pump of , 3 phase, 415 volt, 50 hz, suitable relay range in 5 to 30 Amp, ML contactor, ML over load relay all including taking out old starter single phase preventer fittngs complete all as specified and directed. |
| 10 | Taking out old UNSV MCCB and S&F in replacement of MCCB 4 pole, 63 Amp 36 kA breaking capacity, including suitable size copper lugs and connected fittings, complete all as specified and directed. |
| 11 | Taking out old UNSV MCCB and S&F in replacement of MCCB 4 pole, 100 Amp 36 kA breaking capacity, including suitable size copper lugs and connected fittings, complete all as specified and directed. |
| 12 | Taking out old UNSV MCCB and S&F in replacement of MCCB 4 pole, 250 Amp 36 kA breaking capacity, including suitable size copper lugs and connected fittings, complete all as specified and directed. |
| 13 | Taking out old UNSV MCCB and S&F in replacement of MCCB 4 pole, 400 Amp 36 kA breaking capacity, including suitable size copper lugs and connected fittings, complete all as specified and directed. |
| 14 | Taking out old contractor & S&F in replacement power contactor, type ML-4, 3 pole, 415V, 50Hz, 3 Phase, with auxilary contacts 2 NL&T. |
| 15 | Taking out old contractor & S&F in replacement power contactor, type ML-6, 3 pole, 415 V, 50Hz, 3 Phase with auxilary contacts 2 NO + 2 NC complete all as specified and directed. |
| 16 | Taking out old contractor & S&F in replacement power contactor, type ML-2, 3 pole, 415 V, 50Hz, 3 Phase with auxilary contacts 2 NO + 2 NC complete including taking out all as specified and directed. |
| 17 | Taking out old contractor & S&F in replacement electronic timer for Star Delta Starter type, timing range 3-30 sec, 415 V, 50 Hz complete including taking out all as specified and directed. |
| 18 | S&F in replacement thermal over load relay for Star Delta Starter type, range 5-30 amp, 415 V, 50 Hz complete including taking out all as specified and directed. |
| 19 | S&F in replacement thermal over load relay for Star Delta Starter type, timing range 66-120 amp, 415 V, 50 Hz complete including taking out all as specified and directed. |
| 20 | Taking out old UNSV starter and S&F in replacement fully automatic soft starter of 100 hp capacity Centrifugal motor pump set.Softstrter with Indoor type LT panel consists of followings items:- Indoor type panel powder coated colour RAL 7035,CPRI approved manufactured , Main switch MP based 200 Amp,OL/SS/EF protection builtin,Local/Remote function ,in remote condition the SS will operate from SCADA and in manual mode the SS will operate from panel,Proper cooling system of the panel all as specfied abd directed. |
| 21 | Taking out old UNSV starter and S&F in replacement fully automatic soft starter of 20 hp capacity Centrifugal motor pump set.Softstrter with Indoor type LT panel consists of followings items:- Indoor type panel powder coated colour RAL 7035,CPRI approved manufactured , Main switch MP based 63 Amp,OL/SS/EF protection builtin,Local/Remote function ,in remote condition the SS will operate from SCADA and in manual mode the SS will operate from panel,Proper cooling system of the panel all as specfied abd directed. |
| 22 | Taking out old submersiblle cable and S&F submersible flat copper cabl e of size 6sqmmX3core , 220 volt , 50 Hzall specified and directed.Make-KEI/Polycab/Hevells |
| 23 | S&F in replacement DOL starter of relay range 2 to 5 amp in sheet metal enclosure type, wall mounting suitable for , 3 phase, 415 volt, 50 hz, rp, , ML over load relay all including single phase preventer fittings complete including taking out all as specified and directed.Make: Havells/L&T/ Crompton greaves as approved by GE] |
| 24 | M&L for cleaning of existing drainage system of Filter Pump House and cutting grass around 3 metre both sides, complete including taking out all as specified and directed. |
| 25 | Supply, fabrication and fixing MS chennal/ pipe fitting/barrel piece /lateral pipe as per site requirement including nut, bolt, washer, welding etc and fibre board gasket complete and making joint leak proof including including taking out dismantling old structure complete all as specified and directed. |
| 26 | M&L for welding work of size 12 mm consider one welding job including cutting, jointing and all connected accessories all specified and directed. |
| 27 | M&L for taking out unserviceable submersible pumping set complete with column pipe any capacity and any type from existing bore well carefully without damaging the p/set including connecting parts and lowering the same after repair including provision of suitable size of nut & bolts with washer and suitable packing for column pipes and connection of submersible cable complete all as directed by Engineer -in-Charge.( NOTE: (1) Chain pully block and clamps etc shall be provided by the contractor. (2) Necessary safety pracaution will be responsibility of the contractor. |
| 28 | Supply, install, testing of centrifugal priming pump/vaccum pump of capacity 5 HP, intake 55 LPM, minimum intake rate 55 cum per hour, minimum vaccum develop 650mm/hg, 220 volt, 50 Hz including connection to centifugal pump with & including starter of suitable size/capacity and single core copper cable of 10 sqmm length approx (20 metre) connection from starter to motor complete all specified and directed |
| 29 | Supply,install,commissioing and testing of submersible pump set 10 HP of mim head not less than 130 mtr ,min 15 stage ,motor electric driven 3 phase 415 volt AC,50 Hz,2880 RPM ,high quality abrasion resistance bronze and dynamically balanced impeller complete all as specfied and durected. |
| 30 | Disconnecting/ Dismentling of submersible / centrigual / Monoblock / Pressure Pump / Non Clog motor Pump/ VT Pump/ open well pump Set assy from its foundation at various place of Dronachal pump house and transporting to civil workshop for repair complete and taking back after repairing, fixing to its existing position and making all connections.Dismentling and opening of pump assy for checking out defects. Taking out shaft from pump and carrying out lathe work on shaft for checking and making straightness. Taking out of old worn out brass impeller and M&L for filling material on worn out part , grinding, poilshing and carrying out complete lathe work, refixing on shaft and check for its smooth functioning and balancing.(Parts for following items shall be paid under relevent item here-in-after under as supply). |
| 31 | (a) 100 HP motor |
| 32 | (b) 20 HP motor |
| 33 | (c) 12.5 HP motor |
| 34 | (d) 1 to 5 HP motor |
| 35 | Taking out unserviceable spares and burnt copper binding wire complete. M&L for rewinding of Centrifugal/submersible motor / open well motorwith insulated copper winding wire including sleeves as per original company and replacement of worn out parts, including grinding & polishing of rotor sleeves and refixing, testing & transport charges complete all as specified & directed by EIC (Parts for following items shall be paid under relevent item here-in-after under as supply). |
| 36 | (a) 1 HP to 30 HP Motor |
| 37 | Supply and fix the following parts of the submersible /open well pump and motor for capacity between 1 HP to 5 HP of original company as approved by Engineer-in-charge. ( Note :- .U/S Part other than as listed below of Pump if required to be replaced to make the pump functional is to be replaced by contractor. No extra payment shall be paid to contractor.) |
| 38 | (a) Bowl bush |
| 39 | (b) Impeller |
| 40 | (c) Neck ring |
| 41 | (d) Shaft sleeve |
| 42 | (e) Pump shaft |
| 43 | (f) Coupling |
| 44 | (g) Coupling key |
| 45 | (h) Impeller key |
| 46 | (j) Stud with nuts |
| 47 | (k) Thrust bearing |
| 48 | (l) Lower housing bush |
| 49 | (m) Upper housing bush |
| 50 | (n) Rotor shaft sleave |
| 51 | (o) Drain plug |
| 52 | (p) Water seal |
| 53 | (q) CI Bowl |
| 54 | (r) Bearing Suitable for pump set |
| 55 | (r) Rotor Shaft |
| 56 | Supply and fix the following parts of the submersible /open well pump and motor for capacity between 10 to 20 HP of original company as approved by Engineer-in-charge. ( Note :- .U/S Part other than as listed below of Pump if required to be replaced to make the pump functional is to be replaced by contractor. No extra payment shall be paid to contractor.) |
| 57 | (a) Bowl bush |
| 58 | (b) Impeller |
| 59 | (c) Neck ring |
| 60 | (d) Shaft sleeve |
| 61 | (e) Pump shaft |
| 62 | (f) Coupling |
| 63 | (g) Coupling key |
| 64 | (h) Impeller key |
| 65 | (j) Stud with nuts |
| 66 | (k) Thrust bearing |
| 67 | (l) Lower housing bush |
| 68 | (m) Upper housing bush |
| 69 | (n) Rotor shaft sleave |
| 70 | (o) Drain plug |
| 71 | (p) Water seal |
| 72 | (q) CI Bowl |
| 73 | (r) Rotor Shaft |
| 74 | (s) Bearing Suitable for Existing Pump |
| 75 | Taking out unserviceable spares and burnt copper binding wire complete. M&L for rewinding of submersible motor with insulated copper winding wire including sleeves as per original company and replacement of worn out parts, including grinding & polishing of rotor sleeves and refixing, testing & transport charges complete all as specified & directed by EIC (Parts for following items shall be paid under relevent item here-in-after under as supply). |
| 76 | (a) 100 HP Motor |
| 77 | Supply and fix the following parts of the centrigual Pump and motor for capacity 100 HP of original company as approved by Engineer-in-charge. ( Note :- .U/S Part other than as listed below of Pump if required to be replaced to make the pump functional is to be replaced by contractor. No extra payment shall be paid to contractor.) |
| 78 | (a) Bowl bush |
| 79 | (b) Impeller |
| 80 | (c) Neck ring |
| 81 | (d) Shaft sleeve |
| 82 | (e) Pump shaft |
| 83 | (f) Coupling |
| 84 | (g) Coupling key |
| 85 | (h) Impeller key |
| 86 | (j) Stud with nuts |
| 87 | (k) Thrust bearing |
| 88 | (l) Lower housing bush |
| 89 | (m) Upper housing bush |
| 90 | (n) Rotor shaft sleave |
| 91 | (o) Drain plug |
| 92 | (p) Water seal |
| 93 | (q) CI Bowl |
| 94 | (r) Rotor Shaft |
| 95 | (s) Bearing Suitable for Existing Pump |
| 96 | S&F in replacement to ON load Changeover Switch,Rotory type 100 Amp,415 Volt , TPN, front operated with out sheet metal enclosure suitable for mounting on existing panel as per sample and site requirement complete all as specified and directed |
| 97 | S&F in replacement to ON load Changeover Switch,Rotory type 200 Amp,415 Volt , TPN, front operated with out sheet metal enclosure suitable for mounting on existing panel as per sample and site requirement complete all as specified and directed |
| 98 | S&F in replacement to ON load Changeover Switch,Rotory type 63 Amp,415 Volt , TPN, front operated with out sheet metal enclosure suitable for mounting on existing panel as per sample and site requirement complete all as specified and directed |
| 99 | 28.S&F for SWR rope of size 10 mm outer dia dor tie/anchoring with submersible pumpset all as specified and directed. |
| 100 | S&F Rotational moulded (three layered), ISI marked polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity, hoisted and fixed in position including connecting up pipes including taking down old tank complete all as specified and directed. |
| 101 | Reapir/Maintain of existing flow meter Machine Any size and capacity complete all as specfied and directed. |
| 102 | S& F Bldg Security light 45 watt IP 65 Protection with clamp and braket size 50 mm medium class GI tubing complete with wiring all as specfied and directed. |
| 103 | M&L for installing GI strip of 32x6 mm dimensions and making proper arrangements for connection between earthing and Transformer/ equipment all as specified and directed by Engineer in charge. Please Enable Macros to View BoQ information |
| 104 | M&L for installing GI strip of 32x6 mm dimensions and making proper arrangements for connection between earthing and Transformer/ equipment all as specified and directed by Engineer in charge. Please Enable Macros to View BoQ information |