| 1 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) not exceeding 1.50 Sqm each including taking out hold fast embedded in PCC, complete all as specified and directed. |
| 2 | Cleaning of septic tanks/soakage well of any size, capacity & depth by Mechanically using sewage tankers/ Truck mounted hydraulic jet pressure machine with flushing the sewage line with heavy duty sewage pumps sewage suction pump, by desludging, dewatering, taking out of all materials such as sludge/ soil waste/ polythene /mud/ silt/liquid/ semi liquid /semi solid/ solid or any unwanted items etc, including flushing with adequate water to make the fully functional, re-fixing opened access cover and removing all retrieved material outside the periphery of defence land. Note :- The measurement for the quantity of sludge removed will be arrived by multiplying the inner dimensions of septic tank to actual depth of sludge deposited by dipping the measuring rod. The depth shall be of that wet surface sludge on measuring rod for payment purpose.Note: Contractor/supervisor take complaint from JE concerned all day and ensure to resolve all complaint within same day. Incase of non attending complaints sufficient time as decided by Engr-in-Charge but not more than 3 day ,recovery @ 1000 per day will be recovered from contractor. |
| 3 | M&L for PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in padding over roof slab for providing proper slabs, and finishing the surfaces even & smooth without using extra cement, complete all as specified and directed. |
| 4 | M&L for mild steel work Roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed. |
| 5 | M&L for PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate as surface channels and drain etc including necessary form work complete all as specified and directed. |
| 6 | M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete, Fe-410-W Gde E-250 of quality 'A', complete all as specified and directed. |
| 7 | Excavation in post holes not exceeding 0.50 cum getting out in soft/ loose soil, returning,filling in layers not exceeding 50 mtr and making good surfaces complete all as specified and directed. |
| 8 | S&F Factory made Solid PVC Moulded Door Shutter with wood free EPS, 28 to 30mm thick (stiles) with 5 mm thick moulded prelam PVC sheet on the front face and 5 mm prelam PVC sheet on back face, supplying & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 9 | S&F 100mm long butt hinges medium weight cold rolled ISI marked mild steel complete all as specified and directed including necessary welding if required . |
| 10 | S&F 150mm extruded aluminium alloy handle fabricated anodized ISI marked, complete all as specified and directed. |
| 11 | S&F 150mm long aluminium, anodized barrel tower bolts of extruded section ISI marked, complete all as specified and directed. |
| 12 | S&F ventillators/ louvers with partially guaged shutter using 5 mm thick x 10 cm wide frosted glass strips and following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make and rubber beading and all necessary fittings as required etc all as directed.(a) SP 20048(b) Glazing clips 19352 |
| 13 | S&F GI tubing tubes 20mm bore \\"medium grade\\" galvanized with all fittings and fixed complete to walls and ceiling or laid in floors etc incld cutting chases, pinning in brick/concrete surfaces and making good to facings where required and pointing in cement mortar 1:3 incld dismantling of existing pipe line complete all as specified and directed. |
| 14 | S&F GI tubing tubes 15mm bore \\"medium grade\\" galvanized with all fittings and fixed complete to walls and ceiling or laid in floors etc incld cutting chases, pinning in brick/concrete surfaces and making good to facings where required and pointing in cement mortar 1:3 incld dismantling of existing pipe line complete all as specified and directed. |
| 15 | S&F Mild steel framed work such as grills, gratings using square/round bar with ends of bars shoulders/welded drilling holes for fixing of guard bars, complete all as specified and directed. |
| 16 | M&L for Formwork to sides of square or rectangular pillars, posts, struts, columns etc., complete all as specified and directed. |
| 17 | M&L plain cement concrete (1:2:4) type B-2 (40mm graded aggregate) as in pillars all as specified and directed. |
| 18 | S&F welded steel wire fabric not exc 4kg/sqm complete to wood or steel members all as specified and directed. |
| 19 | M&L for Preparing the new steel surfaces of any description over 10cm width or girth priming with red oxide zinc chrome and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 20 | Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc, complete all as specified and directed. |
| 21 | M&L for brick work in cement mortar 1:6 of old size sub class ‘B' bricks straight or curved on plan exceeding 6mtr mean radius, complete all as specified and directed. |
| 22 | M&L for brick work in cement mortar 1:4 of old size sub class ‘B' bricks straight or curved on plan exceeding 6mtr mean radius, complete all as specified and directed. |
| 23 | M & L for 400x400mmx6 to 7mm thick, non skid ceramic coloured tiles in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete over and including 20mm thick screed bed in CM (1:4) including dismantling floor,hearth or wall tiling incl cement mortar bedding (but not backing), and rubbish off the premises complete all as specified and as directed by Engineer-in-Charge. |
| 24 | M&L for Cement concrete 40mm thick type B-1, 1:2:4 using (20mm graded aggregate)as in finish flooring without using extra cement complete all as specified and directed. |
| 25 | M&L for machine cut Kota stone, stone slab flooring 16-18 mm thick over screed bed 20mm thick in cement mortar 1:4 set, jointed and pointed with grey cement slurry mixed with pigment to match the shade of the slab including, rubbing and granite polishing, complete all as specified and directed. |
| 26 | All as per serial item No. 25 here-in-above but over 10mm thick in cement mortar 1:4 in vertical surface/ skirting complete all as spd and directed. |
| 27 | M&L black sheet 1mm thick covering to door shut ters; covering to door chowkats (frames); , etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required all as specified and directed. |
| 28 | S&F Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted fixed in position all as specified in SSR part-I, capacity of tank 500 ltr incl inlet and outlet connection 20mm dia and 15mm dia GI pipes medium grade respectively 20mm GI pipe medium grade over flow pipe 15cm long and PTMT valve 20mm high pressure with polyethylene float and fly nuts including dismantling water tanks (capacity of tank exc. 250 ltr but n. exc. 500 ltr) and removing from site complete all as specified and directed. |
| 29 | M&L for preparation of old decorated surfaces of walls and applying Two coats of cement base paint white or tinted all as directed. |
| 30 | M&L for applying two coats of oil bound distemper over a coat of suitable primer on old surfaces of walls incld preparation of surfaces complete all as specified and directed. |
| 31 | M&L for preparation of new plastered surface of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. |
| 32 | M&L plain cement concrete (1:4:8) type D-2 (40mm graded aggregate) as in foundation filling and massconcrete complete all as specified and directed. |
| 33 | Taking down cement plaster on brick or concrete surfaces any description including raking out joints hacking for key scrubbing down with water complete all as specified and directed. |
| 34 | M&L for Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement and curing the surface, complete all as specified and directed. |
| 35 | M&L for Rendering 10mm thick in CM 1:3, in ceiling, finished even & smooth without using extra cement and curing the surface, complete all as specified and directed. |
| 36 | S&F of UPVC underground drawings pipe (UDS) type 'B' 160mm dia with wall thickness 4mm (min) and pressured 4 KN /Mtr Sq jointed in cement solvent complete including providing 100 mm thick cement concrete (1:4:8) type D-2 using 40mm graded crushed stone agg as in bed for 160mm bore pipes incl packing under and haunching against the sides of pipes after they are laid tested including taking down old damaged SGSW pipes from existing lines including necessary excavation of old fitted in trenches complete all as specified and directed. |
| 37 | M&L for Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surfaces even & smooth without using extra cement including scaffolding upto 7 meter height and curing the surface, complete all as specified and directed. |
| 38 | M&L for preparation of New plastered surfaces of wall including scaffolding up to 7m height, two coats of cement base paint over a coat of primer on newly plastered surfaces of wall including preparation of surfaces and curing after applying each coat, complete all as specified and directed. |
| 39 | M&L for applying two coats of oil bound distemper over 2-3 mm thick wall care putty on walls surfaces including preparation of surface complete all as specified and directed |
| 40 | Supply & fixing of CP health faucet with ABS body, Stainless Steel hose, 1.20mtr flexible SS tube & hook fixed with and incl CP screws complete all as specified and directed. |
| 41 | M&L for providing glazed ceramic coloured wall tiles of size 300mmx450mmx7mm thick, set, jointed in colour cement to match laid over and including 10 mm thick rendering in cement mortar 1:4 including dismantling of floor tiling incl cement mortar bedding (but not backing)removing serviceable tiles to a store and rubbish off premises, complete all as specified and directed. |
| 42 | S&F 25mm bore GI tubing medium grade galvanized ISI marked with all fittings, laid in trenches or ground/ in walls, complete all as specified and directed. |
| 43 | S&F in repair vitreous china wash down water closet (pedestal pattern) white colour including P or S trap, fixing bolts and connecting to drain pipe, including seat cover plastic flat bottom, Butterfly Stainless Steel Jet or Bidet hands free spray and Stainless Steel Chromium plated hinging device and connection to flush pipe, anti syphonic pipe etc complete all as specified and directed. |
| 44 | S&F in repair vitreous china wash hand basin (flat back or angle back type) coloured of bowl size 550mmx400mm including cutting for and pinning in ends of brackets or erecting stand etc complete all as specified and directed. |
| 45 | S&F 5mm thick looking mirror of size 600x450mm of selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 46 | S&F in repair Towel rail 600mm long fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms), complete all as specified and directed. |
| 47 | S&F in repairs 10 liters PVC low level flushing cistern (white colour) syphonic action type with inlet ball valve float and push type handle including bracket, PVC 32mm dia flush pipe with coupling and fixed complete all as specified and directed. |
| 48 | S&F in repair Vitreous china urinal half stall complete incl providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and incl 60mm long brass screws, pointing around urinal in back in cement; fixing automatic cistern with brackets, flush pipe, grating and union for discharge pipe, complete all as specified and directed. |
| 49 | M&L in repairs 75mm PVC floor trap, including fixed in cement type B-1 (1: 2:4) complete all as specified and as directed. |
| 50 | S&F in repair PVC connection 15mm bore size with PTMT nuts of length 450mm complete all as specified and directed. |
| 51 | S&F in repair pillar tap chromium plated fancy type Swan Neck with capstan heads screwed down high pressure with or without lettered hot or cold with long screwed, shanked and fly nuts screwed for iron pipe 15mm dia complete all as specified and directed. |
| 52 | S&F in repair bib taps, fancy type, chromium plated, cast copper alloy ISI marked with crutch or butter fly handle high pressure screwed down screwed for iron pipe of 15mm bore, complete all as specified and directed. |
| 53 | S&F in repair 15mm bore Angle valve fancy type chromium plated ISI marked with crutch or butter fly handle high pressure screwed both ends for iron pipe or for union and fixed complete all as specified and directed. |
| 54 | S&F PVC (SWR) bends of 75mm bore any radius complete all as specified and directed. |
| 55 | S&F in repair PVC (SWR) 110mm bore pipes, single socketed in any length with rubber ring joints laid in trenches or floor/wall complete all as specified & directed. |
| 56 | S&F in repair PVC (SWR) 75mm bore pipes, single socketed in any length with rubber ring joints laid in trenches or floor/wall complete all as specified and directed. |
| 57 | S&F PVC (SWR) bends of 110mm bore any radius complete all as specified and directed. |
| 58 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 59 | M&L for 75mm thick plain cement concrete type C-2 1:3:6 (using 40mm graded crushed stone aggregate) as in flooring/Sub base all as spd and directed. |
| 60 | M&L for Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 61 | M&L for Non abrasive paving (rectified endura) heavy duty cement concrete coloured tiles 300x300mmx10mm thick set jointed and pointed in neat cement slurry mixed with pigment laid over 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 62 | S&F Prepainted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength 550 Mpa as in roof covering/cladding to walls, fixed with self taping screws, complete all as specified and directed. |
| 63 | S&F pre painted galvalume aluminum zinc coated GI based plain steel sheeting 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to walls, fixed with self taping screws, complete all as specified and directed. |
| 64 | S&F in repair 20mm PTMT ball valve high pressure with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed, complete all as specified and directed. |
| 65 | M&L for liquid water proofing treatment to RCC roof slab incld dismantling of existing treatment of any description in following procedure : (a) Laying 10mm thick rendering in Cement mortar 1:4 mixed with WPC 3% by weight of cement on fair faces of concrete roof surfaces , finished even and fair to receive treatment on roof Complete (b) Applying first coat fiber reinforced elastomeric liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with sun reflective index (SRI) of 100-110, having minimum elongation of 350%, tensile strength 2.9 Mpa and shall have reack bridging ability upto 2.5mm and shall resist 10 bars of hydrostatic pressure reduce surface temperature upto 10 degree celsius with 3.3% dilution as priming coat (c) laying of fiber mesh 0.3mm thickness weave in leno pattern having weight 4.5 gm/ Sqm and pasting it properly with overlap of 50mm and allow it to dry (d) Applying second coat undiluted @ 0.45 ltr/ sqm as directed by Engr-in-Charge (e) Applying third and final coat undiluted @ 0.45 ltr/ sqm as directed by Engr-in-Charge. (The rate includes for filling cracks in existing roof with cement putty using suitable bonding agent (shalcrate 42) before laying cement plaster). |
| 66 | S&F factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other frame/Chowkhat of size 45x70mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum , screw withdrawal strength of 2200N (Face) & 1100N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with properly of being termite/borer proof, water/moisture proof and fire retardant 152 Section 8 and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length, complete all as specified and directed. |
| 67 | S&F 75mm long butt hinges medium weight cold rolled ISI marked mild steel complete all as specified and directed including necessary welding if required . |
| 68 | S&F 75mm Hasp and staple, safety type, aluminum anodised including bolt to hinge plate and fixed with screws complete |
| 69 | S&F in repair mild steel, chromium plated Soap Dish fixed with and incl CP screws all as specified and directed. |
| 70 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for reinforcement cut as required to facilitate demolition, complete all as specified and directed |
| 71 | M&L Providing precast cement concrete 1:2:4 Type B1 using 20 mm graded aggregate, in cover slabs (for manholes etc.) set in CM 1:6 including necessary moulds/ formwork complete all as complete and directed. |
| 72 | M&L for broken stone or boulder hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed. |
| 73 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and directed. |
| 74 | M&L for 25mm thick levelling course in cement concrete type B-1 1:2:4 using 20mm graded aggregate complete all as specified and directed. |
| 75 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 76 | M&L for modular point wiring with 1.5 sqmm (nominal area) PVC insulated FRLS and unsheathed multistranded copper conductor cable 1100 volts grade drawn through and including PVC rigid concealed conduit not less than 1.8 mm thick (ISI marked) with all accessories including suitable modular plate (Inner + Outer) and modular metallic boxes of suitable sizes including 1.5 sqmm PVC FRLS insulated unsheathed copper conductor multistranded cable for continuous earth conductor connected to common earth dolly, complete all as specified & directed for the following :- Note:- Proper colour coding is to be followed as per IS Specification. |
| 77 | One light point controlled by 5 Amp SP, one way, 240 Volts. |
| 78 | All as per item No. 76.00 here-in-before but for one 5 pin 6 Amp socket outlet point on same board |
| 79 | All as per item No 76.00 here-in-before but using 4.00 Sqmm (nominal area) multistranded copper conductor cable for geyser sheet metal plug socket outlet/metal plug top including 4.00 Sqmm size FRLSH PVC insulated and sheathed copper conductor cable as earth conductor (green colour) connected to common earth dolly for geyser on independent point complete all as specified and directed. |
| 80 | S&F of Modular switch piano flush button SP, 1 way 5/6 amps 240 volts with polycarbonate body all as specified and directed. |
| 81 | S&F for Modular socket out let, 6 pin 5/6 and 15/16 amps multi purpose 2 in 1 flush type, 240 volts with polycarbonate body all as specified and directed. |
| 82 | S&F for Modular socket 2 in 1, 6 amps 2/3 pin Combined 2 Modular , 240 volts. with polycarbonate body all as specified and directed. |
| 83 | S&F MCB DB sheet enclosure, Single door type, single pole and neutral 240V with 200 Amp rated bus bar suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete confirming to IP 42/43 without MCB and with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed. |
| 84 | S&F surface and wall mounted LED batten with polycarbonate housing and integrated electronic driver tube light fitting 20W, 3.5/4 ft long, 220 Volts , and connecting to ceiling rose with three core twisted flexible copper cable of suitable size complete all as specified and directed. |
| 85 | M&L for ceiling rose surface bakelite 2 to 3 terminals with polycarbonate body complete all as specified and directed. |
| 86 | S&F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 87 | S&F exhaust fan, steel body AC single Phase. 230V of size 250 mm sweep with, blades, and frame and louvers complete all as specified and directed. |
| 88 | S&F 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 89 | S&F 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 32 Amp current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 90 | Supply and laying in replacement of cable XLPE insulated armoured heavy duty electric cable with extruded insulation aluminium conductor, 1100 volts grade of cross sectional area 6 Sqmm 2 Core, complete all as specified and directed. |
| 91 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cables, pipes etc and getting out in any type of soil complete all as specified and directed. |
| 92 | Returning filling in including spreading, leveling and well ramming, in layers not exceeding 25 cm each layer of any type of soil complete all as specified and directed. |
| 93 | Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 94 | M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified and directed. Note: Punned thickness of sand shall be measured. |
| 95 | Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge |
| 96 | Material and labour for replacement of GI tubing light grade 20 mm bore for passing through cables under the floor, along the wall or along the pole complete all as specified and directed . |
| 97 | M&L for cutting existing GI/CI pipe line of size 40/25 mm dia pipe making new connection for GI pipe including short pieces , inserting tees, bends ,sockets, union etc with existing water line, complete all as specified and directed |
| 98 | S&F stop valve 25 mm dia cast copper alloy screwed on high pressure with crutch or butterfly handle screwed bolts ends, for iron pipe or for union and fixed complete all as specified and directed. |
| 99 | M&L for earthing complete with galvanized steel earth plate electrode 60cmX60cm X6mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth lead wire of 4.0mm dia by means of nuts bolts, washers, check nuts of iron or steel including PCC pits and RCC cover in PCC 1:2:4 (type B-1) and necessary earth work in any type of soil medium grade GI watering pipe 20 mm dia with funnel and wire mesh and 15mm bore GI pipe light grade protection pipe upto test point etc including excavation and charcoal, common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I. all specified |
| 100 | Note: (i) In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.(ii) The Schedule of Credit amount shall be deducted from the total of this schedule (BoQ) to arrive at Contract Sum. Please Enable Macros to View BoQ information |