| 1 | Cleaning of blockage of bathroom / kitchen by cleaning the Nahani traps / gully / traps / floor trap of all the mud / Indian WC / European type WC / Wash hand basin / Urinal of all the mud / sludge / sludge and getting out including cleaning of SGSW / CI Pipe upto 1st manhole / washed thoroughly to grating of trap, CI waste pipe by opening the cleaning eye and depositing of sludge in a pit of suitable size at a distance not exceeding 50 metres form the gully trap and covering the same with the soil obtained from excavation of pit including all excavation as directed and whenever required and any urgent sewer blockages work as per directions by JE as per site requirement complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Cleaning of Blockage in sewage line having dia of 100mm to 150mm by deploying of skilled safaiwala by roding, sewage cleaning rod and ball system up to a depth of 1.50 mtr and removing of silt / cached mud / waste obtained from sewage line upto a lead of 2.50 KM to 5.00 KM complete all as specified and as directed. |
| 3 | All as per Ser item No 2.00 above but depth of sewer exceeding 1.50 metre but not exceeding 3.00 metre. |
| 4 | All as per Ser item No 2.00 above but dia of sewage line exceeding 150mm but not exceeding 300mm dia and depth of sewage line exceeding 3.00 metre but not exceeding 4.50metre. |
| 5 | Preventive and routine cleaning of Manhole through systematic Programme of cleaning / removing of silt accumulation chamber / manholes through a sewer cleaning gang under supervision of competent person including taking all safety precaution to avoid mis happenings and removal of silt / cached mud up to distance exceeding 2.5KM but not exceeding 5.00KM upto depth of manholes upto 1.50metre complete all as specified and as directed. |
| 6 | All as per Ser item No 5.00 above but depth of manholes exceeding 1.50metre but not exceeding 3.00metre. |
| 7 | All as per Ser item No 5.00 above but depth exceeding 3.00metre but not exceeding 4.50metre. |
| 8 | Routine cleaning of sewer through a systematic programme of cleaning of sewage line through Providing Suction cum Jetting sewerage Cleaning Machine as per Technical Specification along with safety equipment viz mask, Oxygen Cylinder, gloves, rope ladder, venella rope, body suits and helmet etc and attending sewer cleaning of sewer mains in lanes, sub lanes depth up to 1.50 metre including preventive maintenance of sewer lines and as directed by the Engineer-in-Charge. |
| 9 | All as per Ser item No 8.00 above but depth exceeding 1.50metre but not exceeding 3.00metre. |
| 10 | All as per Ser item No 8.00 above but depth exceeding 3.00metre but not exceeding 4.50metre. |
| 11 | Providing one trolley mounted sewage pump of non clogging type with self proming unit, 6.5 BHP capacity, diesel driven with discharge pipe including fuel, pump operator and pumping out of sewage / sludge effluent from sewage sump (to be used on failure of existing pumping system) to keep line clear complete all as specified and as directed. |
| 12 | Cleaning septic tank of 50 Users capacity including removal of sludge / sewage water and disposal to outside MD land and covering with layer of earth and sprinkling adequate quantity of lime powder to avoid health hazard complete all as specified and as directed. |
| 13 | All as per Ser item No 12.00 above but 100 users capacity |
| 14 | All as per Ser item No 12.00 above but 150 users capacity |
| 15 | All as per Ser item No 12.00 above but 200 users capacity |
| 16 | Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), for all kind of soil including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m complete all as specified and as directed. |
| 17 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5m complete all as specified and as directed. |
| 18 | Dismantling of old S.W / Sewage pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps : 150 mm diametre complete all as specified and as directed. |
| 19 | Material and labour for double wall corrugated pipes of 150mm bore, S 20 Grade made with HDPE material used for conveying and facilitating smooth flow of sewage and rodent proof in any length with rubber ring and solvent joints, including couplers and all necessary fixing arrangements laid in trenches or in floors complete all as specified and as directed.NOTE : These pipe shall have smooth internal surfaces and corrugated external surfaces. |
| 20 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto haunches of HDPE pipes including bed concrete as per standard design : 150 mm diametre HDPE pipe complete all as specified and as directed. |
| 21 | Material and labour for making good the road cutting portion with plain cement concrete 75mm thick PCC 1:2:4 type B1 (using 20mm graded aggregate) including finishing the concrete topping even and fair complete all as specified and as directed. |
| 22 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. For pipes 100 to 250 mm diametre complete all as specified and as directed. |
| 23 | Demolishing cement concrete any description manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-Charge. |
| 24 | Providing and laying Cement concrete 1:4:8 (1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) as a sub base complete all as specified and as directed. |
| 25 | Providing and laying cement concrete 1:2:4 (1 Cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural source sin retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of cantering, shuttering and finishing complete all as specified and as directed. |
| 26 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling and dressing and finishing the top smooth complete all as specified and as directed. |
| 27 | Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge. |
| 28 | Providing and fixing 75mm thick precast reinforced cement concrete (RCC) 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), Type B-1, in cover slabs for manholes, water tanks, etc., including cantering, shuttering, using 8mm dia TMT bars reinforcement, casting, curing, and finishing, and setting in cement mortar 1:4 (1 cement : 4 coarse sand), complete in all respects as per CPWD specifications and as directed by the Engineer-in-Charge. |
| 29 | Demolishing brick work In cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge. |
| 30 | Providing and laying autoclaved aerated cement blocks masonry with 150mm / 230mm / 300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. NOTE : The payment of RCC band and reinforcement shall be made for separately. |
| 31 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and as directed. |
| 32 | Material and labour for 15 mm thick cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 coarse sand), finishing the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 33 | Supply only integral water proofing compound complete all as specified and as directed. |
| 34 | Dewatering the existing PVC tank of 500 Ltr capacity kept over roof slab of building of any height and cleaning internal surfaces of tanks to remove scales, mud and other foreign materials, scrubbing with water using coir / Jute brushes and washing the surface with fresh water cleaning the surface with mixture of bleaching powder and water and finally washing with fresh water to surfaces and bottom surfaces etc complete and writing in Block CPITAL letters denoting \\"CLEANED ON (DATE)' and DUE ON (DATE)' , size of letter shall be 50mm complete all as specified and as directed.NOTE : Cleaning of OHT shall be done every four months during the contract period and measurement shall be taken at each time of cleaning. |
| 35 | All as per Ser item No 34.00 above but water tank 1000 Ltrs Capacity. |
| 36 | All as per Ser item No 34.00 above but water tank 2000 Ltrs Capacity. |
| 37 | All as per Ser item No 34.00 above but water tank 5000 Ltrs Capacity. |
| 38 | All as per Ser item No 34.00 above but water tank 10000 Ltrs Capacity. |
| 39 | Supply and fix in repairs PVC tank cover suitable for PVC tanks of capacity 500 to 10000 Ltrs including necessary fixing arrangements etc complete as in repairs (ISI Mark). |
| 40 | Dismantling tiles work in floors/wall tiles or Mosaic tiles for the thickness of tiles 10mm to 25mm including cement mortar and stacking material within 50 metres lead complete all as specified and as directed. |
| 41 | Providing and laying Ceramic Non skid floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on and including 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete all as specified and directed. |
| 42 | Providing and fixing Ist quality ceramic glazed wall tiles of size 450x300x6 to 7mm thick conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in walls, skirting, risers of steps and dados, over and including12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete all as specified and as directed. |
| 43 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts, guard bars etc. Of area 3 sq. metres and below complete and stacking within 50 metres lead complete all as specified and as directed. |
| 44 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer- in-Charge. |
| 45 | Providing and fixing for 25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm x 25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25 mm X 11 mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer’s specification and direction of Engineer-in-Charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places complete all as specified and as directed. |
| 46 | Providing and fixing ISI marked M.S. pressed butt hinges 100x58x1.90 mm bright finished with necessary screws etc. complete all as specified and as directed. |
| 47 | Providing and fixing aluminium tower bolts 200x10 mm, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified and as directed. |
| 48 | Providing and fixing aluminium handles 125 mm, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified and as directed. |
| 49 | Providing and fixing LLDPE Septic tank of 20 user capacity on site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete all as specified and as directed. |
| 50 | Providing and fixing LLDPE Septic tank of 25 user capacity on site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete all as specified and as directed. |
| 51 | Material and labour for soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size : 1.2 M dia X 3 M effective depth complete all as specified and as directed. |
| 52 | Dismantling 15 to 40 mm dia G.I. pipe internal connection inlet and outlet connections including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge. |
| 53 | Providing and fixing 20mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply and all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. |
| 54 | Providing and fixing 25mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply and all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. |
| 55 | Providing and fixing 15mm nominal bore C.P. brass bib cock of approved quality conforming to IS:8931 complete all as specified and as directed. |
| 56 | Providing and fixing 15mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 complete all as specified and as directed. |
| 57 | Supply and fix in repairs Chromium plated bib cock 2 way double handle with flange complete all as specified and as directed. MAKE : JAQUAR / GROHE / KOHLER |
| 58 | Providing and fixing White Vitreous China Flat back wash basin size 450x300 mm with single 15mm C.P. brass pillar tap, C.I. brackets, 32mm C.P. brass waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require complete all as specified and as directed. |
| 59 | Providing and fixing 15mm nominal bore uplasticised PVC connection pipe 45cm length with brass unions complete all as specified and as directed. |
| 60 | Providing and fixing 32 mm dia P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete all as specified and as directed. |
| 61 | Disconnecting damaged overhead / terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-Charge. |
| 62 | Providing and placing on terrace (at all floor levels) polyethylene TRIPLE LAYERED water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank complete all as specified and as directed. |
| 63 | Providing and fixing for 20 mm nominal bore ball valve (brass) of approved quality, High or low pressure, with plastic floats complete all as specified and as directed. |
| 64 | Providing and fixing for 20 mm nominal bore gun metal gate valve with C.I. wheel of approved quality (screwed end) complete all as specified and as directed. |
| 65 | Supply and fix CP grating 100mm dia round fixed on floor / nahani trap fixed with cement mortar complete all as specified and as directed. |
| 66 | Supply and fix in repair hand shower (health faucet) with 8mm dia 1 mtr long flexible tube and wall hook chromium plated complete all as specified and as directed. |
| 67 | Supply and fix for Stainless Steel Material 202 grade soap dispenser, 800ml capacity with wall-mounted plate, make sure it mounted tightly complete all as specified and as directed. |
| 68 | Providing and fixing PTMT towel rail 600mm long with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour complete all as specified and as directed. |
| 69 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete all as specified and as directed. |
| 70 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials including malba all complete as per directions of Engineer-in-Charge. |
| 71 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required complete all as specified and as directed. |
| 72 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid complete all as specified and as directed. |
| 73 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required complete all as specified and as directed. |
| 74 | Supply and fix Rectangular shaped urinal partition with 8mm thick frosted glass of size 450 x 900mm with smooth edges complete all as specified and as directed.MAKE : JAQUAR |
| 75 | Dismantling C.I. or PVC rain water pipe with fittings and clamps including stacking the material within 50 metres lead :75 to 80 mm dia pipe complete all as specified and as directed. |
| 76 | Dismantling C.I. or PVC rain water pipe with fittings and clamps including stacking the material within 50 metres lead :100 mm dia pipe complete all as specified and as directed. |
| 77 | Providing and fixing on wall face unplasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed 75 mm diametre pipes complete all as specified and as directed. |
| 78 | Providing and fixing on wall face unplasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed 110 mm diametre pipes complete all as specified and as directed. |
| 79 | Providing and fixing on wall face unplasticized - PVC moulded fittings / accessories for unplasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.; Single tee without door, Size; 75x75x75 mm complete all as specified and as directed. |
| 80 | Providing and fixing on wall face unplasticized - PVC moulded fittings / accessories for unplasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion.; Single tee without door, Size;110x110x110 mm complete all as specified and as directed. |
| 81 | Providing and fixing on wall face unplasticized - PVC moulded fittings / accessories for unplasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion.; 75 mm bend complete all as specified and as directed. |
| 82 | Providing and fixing on wall face unplasticized - PVC moulded fittings / accessories for unplasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion.; 110 mm bend complete all as specified and as directed. |
| 83 | Material and labour for providing 100mm thick vaccum dewatered floor of Ready Mix Concrete (M-25 grade) including side shuttering (MS channel) and vibrating the same using double screed vibrator, removal of excess water using vaccum pump, suction matt, floating and revolling of concrete to the required finish using skin floater and power trovel complete all as specified and as directed. |
| 84 | Supply and application of non metallic floor hardener @ 3 Kg / Sqm on wet concrete mate complete all as specified and as directed.MAKE - NITOFLOR of FOSROC or Equivalent |
| 85 | Cutting the groove of size 3mm x 20mm using diamond cutter on vaccume dewatered floor and filling the same with bitumen complete all as specified and as directed. |
| 86 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead complete all as specified and as directed. |
| 87 | Material and labour for steel work welded in built up sections / framed work, in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required complete all as specified and as directed. |
| 88 | Material and labour for painting with synthetic enamel paint to new steel surfaces and two or more coats on new work of approved brand and manufacture to give an even shade complete all as specified and as directed. |
| 89 | Dismantling of 60 mm thick precast cement concrete paver blocks, including removal by manual means, carefully stacking of serviceable paver blocks within site premises, and disposal of unserviceable materials within a lead of 50 metres, complete as directed by Engineer-in-Charge. |
| 90 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size / shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.(a) 60 mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. |
| 91 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-Charge, beyond 50 m initial lead, for all leads including all lifts involved complete all as specified and as directed. Please Enable Macros to View BoQ information |