| 1 | Demolition of concrete block walling, brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles etc complete all as specified and directed. |
| 2 | Dismantling of wrought iron or mild steel work of any description in any position not otherwise provided for complete all as specified and directed |
| 3 | Taking up or down GI tubing and connections 15mm bore including cleaning or removal to store complete all as specified and directed. |
| 4 | Taking up or down GI tubing and connections 20mm bore including cleaning or removal to store complete all as specified and directed. |
| 5 | Taking up or down steel tubing and connections of 25mm bore including cleaning or removal to store complete all as specified and directed. |
| 6 | Taking down cement plaster on brick or concrete surfaces of wall/ceiling and likes including racking out joints, hacking for keys scrubbing down with water etc any description including removal of rubbish outside MoD land, complete all as specified and directed. |
| 7 | M&L for providing precast cement concrete block masonary with solid blocks exc 10 cm width, type C-1 (1:3:6) using 20mm graded aggregate and set in cement mortar (1:6) complete all as specified and directed. |
| 8 | M&L for rendering 15 mm thick in cm (1:4) on fair faces of concrete surfaces and finished even and smooth without using extra cement and mixed with WPC complete all as specified and directed |
| 9 | M&L for Rendering 15mm thick in CM 1:6. finished even & smooth without using extra cement to walls complete all as specified and directed. |
| 10 | M&L for two or more coats distempering on newly plastered surfaces with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification incl a coat of 1.5 mm (average) thick wall care putty complete all as specified and directed |
| 11 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & ungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over newly plastered surfaces of wall etc complete all as specified and as directed by Engr-in-Charge. |
| 12 | M&L for MS Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 13 | M&L for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including preparation of new steel surfaces of any description exc 10cm in width or girth complete all as specified and directed. |
| 14 | Supply and laying of 16mm outer dia CPVC pipes SDR 11 & plain CPVC SDR fittings on walls/ceiling or laying in floor complete all as specified and directed. |
| 15 | Supply and laying of 20mm outer dia CPVC pipes SDR 11 &plain CPVC SDR fittings on walls/ceiling or laying in floor complete all as specified and directed. |
| 16 | Supply and laying of 25mm outer dia CPVC pipes SDR 11 &plain CPVC SDR fittings on walls/ceiling or laying in floor complete all as specified and directed. |
| 17 | S & F in repair 25 mm dia Ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, ISI marked (Minimum weight 455 gms), screwed & suitable for iron pipe 25 mm bore, complete all as specified and directed. |
| 18 | S & F in repair 20 mm dia Ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, ISI marked (Minimum weight 455 gms), screwed & suitable for iron pipe 25 mm bore, complete all as specified and directed. |
| 19 | S & F 20 mm dia Ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, ISI marked (Minimum weight 455 gms), screwed & suitable for iron pipe 25 mm bore, complete all as specified and directed. |
| 20 | Dismantling of PVC water storage tank of capacity exceeding 250 litre but not exceeding 500 litre, including removal of rubbish outside MoD land complete all as specified and directed. |
| 21 | Dismantling of PVC/ RCC water storage tank of capacity exceeding 500 litre but not exceeding 1000 litre, including removal of rubbish outside MoD land complete all as specified and directed. |
| 22 | S&F Rotational moulded PVC, double layered, water storage tanks of capacity 500 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 23 | S&F Rotational moulded PVC, double layered, water storage tanks of capacity 1000 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 24 | S&F in repairs for 15 mm bore dia pipe Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 25 | S&F in repairs for 20 mm bore dia pipe Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 26 | Disconnecting existing tank exc.250 litres but not exc 500 litres capacity, setting aside (or lowering if required), cleaning by seven stages cleaning and sterilization of water tanks through bactoriological treatment by using TERBAC-5G, TERBAC-G65 and Ultra voilet rays as following and reconnecting and re-fixing in same position including writing date of cleaning in DD/MM/YYYY etc complete all as specified and directed.(i) Drain out the water by using exit valve or our own high capacity de watering system(ii) Cleaning all the algae formation inside the tank by using TERBAC-G10 a laboratory tested branded chemical of the company and scrubbing the walls of the tanks.(iii) Fresh water cleaning by high speed jet pump with pressure 5 PSI.(iv) First bacteria screening is Sterilization by using TERBAC-G5 a Laboratory certified branded halogen compound, test certificate of TERBAC-G5 from government laboratory mentioning suitability for sterilization should be submitted to the office before using for sterilization .(v) Cleaning the floor of the water tank by heavy duty industrial vacuum cleaner.(vi) Second bacteria screening and sterilizing method by using ultra violet ray. Ejector covering 360 degree with in the tank and kills all suspended bacteria.(vii) Cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified branded strong oxidizing agent TERBAC-G65.Test certificate of TERBAC-G65 From Government Laboratory mentioning suitability for sterilization should be submitted to the office before using for Sterilization. NOTE: CONTRACTOR WILL SUBMIT GOVERNMENT LABORATORY TEST CERTIFICATE OF TERBACG5, TERBAC-G65, FIX THE STICKER MENTIONING THE DATE OF CLEANING & NAME OF SITE ANDALSO PROVIDE CERTIFICATE CONFIRMING THE COMPLETION OF STERILIZATION OF WATERTANKS MENTIONING THE NAME OF STATION AND DATE OF CLEANING. ALL THE CLEANING &STERILIZATION STAFFS SHOULD BE UNDER ACCIDENTAL INSURANCE COVERAGE. |
| 27 | Disconnecting existing tank exc.500 litres but not exc 1000 litres capacity, setting aside (or lowering if required), cleaning by seven stages cleaning and sterilization of water tanks through bactoriological treatment by using TERBAC-5G, TERBAC-G65 and Ultra voilet rays as following and reconnecting and re-fixing in same position including writing date of cleaning in DD/MM/YYYY etc complete all as specified and directed.(i) Drain out the water by using exit valve or our own high capacity de watering system(ii) Cleaning all the algae formation inside the tank by using TERBAC-G10 a laboratory tested branded chemical of the company and scrubbing the walls of the tanks.(iii) Fresh water cleaning by high speed jet pump with pressure 5 PSI.(iv) First bacteria screening is Sterilization by using TERBAC-G5 a Laboratory certified branded halogen compound, test certificate of TERBAC-G5 from government laboratory mentioning suitability for sterilization should be submitted to the office before using for sterilization .(v) Cleaning the floor of the water tank by heavy duty industrial vacuum cleaner.(vi) Second bacteria screening and sterilizing method by using ultra violet ray. Ejector covering 360 degree with in the tank and kills all suspended bacteria.(vii) Cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified branded strong oxidizing agent TERBAC-G65.Test certificate of TERBAC-G65 From Government Laboratory mentioning suitability for sterilization should be submitted to the office before using for Sterilization. NOTE: CONTRACTOR WILL SUBMIT GOVERNMENT LABORATORY TEST CERTIFICATE OF TERBACG5, TERBAC-G65, FIX THE STICKER MENTIONING THE DATE OF CLEANING & NAME OF SITE ANDALSO PROVIDE CERTIFICATE CONFIRMING THE COMPLETION OF STERILIZATION OF WATERTANKS MENTIONING THE NAME OF STATION AND DATE OF CLEANING. ALL THE CLEANING &STERILIZATION STAFFS SHOULD BE UNDER ACCIDENTAL INSURANCE COVERAGE. Please Enable Macros to View BoQ information |