| 1 | Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed. |
| 2 | Excavation in trenches not exc 1.5mtr deep and not exc 1.5mtr wide for foundation etc or for shafts, wells, cesspits, manholes, pier holes, laying cable, erection of poles, stay assembly etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 3 | M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. |
| 4 | Earth filling under floor spreading and levelling in layers n.exc 25 cm thick incl well ramming and watering as required complete all as specified and directed.Note 1. Earth filling will be done from excavated mtrl obtained from Ser Item No. 2 above.2. Compacted thickness will be measured and paid. |
| 5 | Returning, filling in including ramming, consolidating etc of each layer n.exc 25cm thick in hard/dense soil complete all as specified and directed. |
| 6 | Removing excavated meterial to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 7 | M & L for damp proof course to horizontal or vertical surface including necessary form work in PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) using water proofing compound if required, 40 mm thick complete all as specified and directed.Note : Water proofing will be measured and paid separately. |
| 8 | Supply only water profing compound complete all as diected. |
| 9 | M&L for Hardcore of broken stone or boulders of gauge n. exc. 63 mm deposited, spread and levelled in layers N. exc. 15 cm thick watered and rammed to a true surface complete all as specified and directed. |
| 10 | M&L for 75 mm thick plain cement concrete, (1:4:8), type D-2 (using 40 mm graded stone aggregate), as in sub base of floors complete all as specified and directed. |
| 11 | M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.50mm graded stone aggregate) as in levelling courses or floors finishing complete all as specified and directed. |
| 12 | M&L for 75mm thick, PCC 1:3:6 type CI (using 20mm graded stone aggregate), finished even and smooth without using extra cement as in plinth protection laid in alternate bays incl joints filling complete all as specified and directed. |
| 13 | M&L for RCC M-25 (Design mix) as in foundation, incl rafts, footings, foundation beams, plinth beams, bases for columns etc, basement slabs under reamed piles and mass concrete complete all as specified and directed. |
| 14 | M&L for RCC M-25 (Design mix) as in columns, pillars, piers, post and struts complete all as specified and directed |
| 15 | M&L for RCC M-25 (Design mix) as in beams, cantilevers, bressumers, lintal over 1.5 M span complete all as specified and directed |
| 16 | M&L for RCC M-25 (Design Mix) as in slab supported on walls, beams and columns in floors roofs landings balconies canoipes, deck slabs and in shelves complete all as specified and directed. |
| 17 | M&L for Form work flat, rough finished surfaces of footings, sides of concrete foundatins, based of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter complete all as specified and directed. |
| 18 | M&L for Form work flat, rough finished surfaces of posts, struts, piers columns, sides of pillars etc complete all as specified and directed. |
| 19 | M&L for Form work flat, rough finished surfaces of beams, haunching, girders bressumers, lintels cantilevers shelves incl supports, overhangs sides and soffits of floor or roof beam, also spalys between floors and beams etc complete all as specified and directed |
| 20 | M&L for Form work, flat, rough finished surfaces of soffits of suspended slab such as roof slabs floor slabs etc complete all as specified and directed. |
| 21 | M&L for Form work, flat, rough finsihed to edges of concrete flat, traeads, breaks in floor window cills concrete railing exc 10cm but n.exc 20cm wide rough finished surfaces of concrete complete all as specified and directed. |
| 22 | S&F TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending etc and securing with including Mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 23 | Supply and fixing Deformed or TMT steel bars 8mm or 10mm dia in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia all as specified. |
| 24 | S&F TMT bars 6 to 8 mm dia and over upto 10mm as in stirrups,cut to length, bent to shape required, including cranking, bending etc and securing with including mild steel wire (annealed) not less than 0.9mm dia as in stirrups complete all as specified and directed. |
| 25 | M&L for Precast cement concrete block masonry with solid blocks type C-1, 1:3:6 (20mm graded aggregate) exc 10cm in width and setting in mortar 1:6 complete all as specified and directed. |
| 26 | M&L for Precast cement concrete block masonry with solid blocks grade type B1 1:2:4 (20mm graded aggregate) n.exc 10cm in width and setting in mortar 1:6 complete all as specified and directed. |
| 27 | M&L for rendering 15 mm thick on stone masonry/PCC block masonry surface of walls in CM 1:6, surface finished even and surface without using extra cement complete all as specified and directed. |
| 28 | M&L for rendering 15 mm thick on stone masonry/PCC block masonry or brick masonry of external surface of walls in CM 1:4, surface finished even and smooth without using extra cement complete all as specified and directed. |
| 29 | M&L for rendering 5mm thick on fair faces of concrete surface of ceiling/Chajjahs in CM 1:3, surface finished even and smooth without using extra cement complete all as specified and directed. |
| 30 | M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash, complete all as specified and directed. |
| 31 | M&L for preparation of newly plastered wall surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 32 | M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed. |
| 33 | M&L for Non skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles including 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 34 | M&L for Glazed ceramic coloured tiles 350x250x7mm/ 450x300x7mm thick on vertical surfaces such as dados and risers to step etc, set and jointed in neat cement slurry and pointed in coloured cement to match the tiles including 10mm thick rendering in CM 1:4 as backing coat to receive wall tiles complete all as specified and as directed. |
| 35 | S&F Factory made solid PVC door frame of size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube fixed to wall complete all as specified and directed. |
| 36 | S&F Factory made solid PVC moulded door shutter , 30mm thick (stiles) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for tip rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the MS frame wedded / sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement supplying and fixing in the frame at site as per specification and drawing complete all as specified and directed. |
| 37 | S&F Butt hinges MS 100 mm, medium weight, cold rolled complete all as specified and directed |
| 38 | S&F Aluminium handle 150 mm cast type anodized complete all as specified and directed. |
| 39 | S&F Aluminium anodized tower bolt 150 mm size complete all as specified and directed. |
| 40 | S&F 300mm aluminium alloy, anodized, sliding door bolts with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 41 | S&F Vitreous China squatting pan, ‘Orissa’ pattern, WC of size 580 x 440 mm white, with integral foot rests, trap, flush pipe including connection to trap and flushing pipe, antisyphonage pipe etc. complete all as specified and directed. |
| 42 | S&F Vitreous China Wash down water closet pan pedastel pattern (EWC) white in colour with and incl plastic water seat and cover white closed pattern with flat bottom and cover and MS chromium plated hinging device incl 2 way CP 15mm Bib tap Quarter turn fancy type with crutch or butterfly handle incl health faucet ABS body with wall hook and 1.25 metre long SS braided rubber hose pipe and wall hook mounted type and incl connection to outgoing pipe and flushing pipe complete all as specified & directed |
| 43 | S&F Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; supply and fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed. |
| 44 | S&F 110 mm bore PVC SWR pipe single socketed in any length with rubber ring joint laid in trenches or floor complete all as specified and directed. |
| 45 | S&F 75 mm bore PVC SWR pipe single socketed in any length with rubber ring joint laid in trenches or floor complete all as specified and directed. |
| 46 | S&F PVC (SWR) bends 110mm dia any radius with access door complete all as specified and directed. |
| 47 | S&F PVC (SWR) bends 75 mm dia any radius with access door complete all as specified and directed. |
| 48 | S&F PVC (SWR) floor trap 75 mm dia with grating including joint with solvent cement complete all as specified and directed. |
| 49 | S&F PVC flushing cistern low level of 10 liter capacity white with inlet ball valve float and handle including bracket and PVC connections 15 mm size with PTMT nut of length 450 mm etc. complete all as specified and directed |
| 50 | S&F Vitreous china wash hand basin white flat back size 550x400mm including chromium plated fancy type long neck pillar tap capstain head suitable for 15mm bore of pipe, CI bracket. CP waste coupling and PVC waste pipe 75 cm long and 15mm dia and 450mm long PVC connection pipe complete all as specified and directed. |
| 51 | S&F Looking mirror 600x450mm beveled edge with PVC sheet frame and back supported with 6mm thick AC building board or plywood sheet complete all as specified and directed. |
| 52 | M&L for 5mm thick rendering cm 1:3 on top of roof slab using water proofing compound as per manufacturer's instruction complete all as directed.Note : WPC will be measured and paid seprately. |
| 53 | M&L for Applying oil bound bitumen primer @ 1.50 Kg/Sqm and providing 3 mm thick APP modified water proofing membrane weighing 3.6 kg/sqm reinforced with non woven polyester matt weighing not less than 150 gm /sqm having softening point not less than 140 centigrate, having tensile strength of 650N/sqm and 350 N/sqm in longitudinal and transverse directions respectively of the reinforced tearing strength of 180N by torch application with minimum 10cm side overlap and 15cm end lap, applying a coat of blown grade hot bitumen 85/25 over the membrane @ 1.2 Kg /Sqm top of membrane surface shall then be finished with solar reflective bituminious aluminium paint @ 0.10 Kg/Sqm complete all as directed including taking down existing treatment complete all as specified and directed. |
| 54 | S&F Powder coated aluminium sliding window (three way) frame & shutter with glazed shutter and without wiremesh shutter /skeleton section with the following details :-(i) Aluminium frame section 116x36.50x1.80mm.(ii) Aluminium shutter glazed/skeleton section 50x20x1.50mm thick.(iii) Aluminium grill size 50mmx50mm and 4 to 5mm thick bars complete all as specified.(iv) Fixing arrangements legs in hold fast in walls incl PCC (1:3:6) making goog distributed surfaces complete in originally shape.(v) 4mm thick glass orinary quality and fixed with rubber gasket for with glazed shutter etc.(vi) Stainless steel wire mesh 0.36mm nominal dia avg aperature 1.14mm and fixed with rubber gasket for without glazed shutter etc.(vii) Aluminium disc /bow hanle and locking system complete |
| 55 | S&F Powder coated aluminium Ventilator (partially fixed glazing and Partially louvered glazing) with the following details :-(i) Aluminium frame section 45x25x1.80mm.(ii) Fixing arrangements legs in hold fast in walls incl PCC (1:3:6) making goog distributed surfaces complete in originally shape.(v) 4mm thick frosted glass orinary quality (partially fixed glazing and Partially louvered glazing) and fixed with rubber gasket for with glazed shutter etc. |
| 56 | S&F 20 mm outer dia CPVC Pipe (ISI Marked) SDR II & plain CPVC SDR II fittings fixed on wall, celing or floors complete all as specified and directed. |
| 57 | S&F 25m outer dia CPVC Pipe (ISI Marked) SDR II & plain CPVC SDR II fittings fixed on wall, celing or floors complete all as specified and directed. |
| 58 | S&F 15mm Bib taps chromium plated fancy type cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for union with long screwed and fixed complete all as specified and directed. |
| 59 | S&F 15mm bore stop valves fancy type chromium plated cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fixed complete all as specified and directed. |
| 60 | S&F Brass chromium plated tubular towel rail, 20mm dia ‘D’ type, 60CM long between flanges complete all as specified and directed. |
| 61 | M & L for DWCPE(SN4) pipes nominal dia 172.50 (OD)/148.50(ID) mm diameter Pipes) laid on any depth of trenches including jointing/cutting as required length pipes with jointing with socket/spight with elastomeric sealing complete activities to execute and make sewer line functional all as specified and directed by Engr-in-Charge |
| 62 | M&L for cement concrete 1:2:4 type B1 using 20mm graded aggregate as in benching, bed plates, coping and the like including weathering, slightly rounded or chamfered angles as directed including formwork and finishing all exposed surfaces complete all as specified and directed by Engr-in-Charge. |
| 63 | M&L for precast reinforced cement concrete type B-1, 1:2:4 (20mm graded) aggregate as in manhole cover slab and similar work including necessary form work complete all as specifed and directedNote : Reinforcement will be measured and paid separately. Please Enable Macros to View BoQ information |
| 64 | M&L for precast reinforced cement concrete type B-1, 1:2:4 (20mm graded) aggregate as in manhole cover slab and similar work including necessary form work complete all as specifed and directedNote : Reinforcement will be measured and paid separately. Please Enable Macros to View BoQ information |