| 1 | Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, socket or power) complete including fittings such as switches ceiling roses, regulators, sockets light fittings, fans etc and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Point wiring complete concealed with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concelaed type wiring incl GI / MS branded sunken boxes suitable for normal / modular concealed on walls including plastic / heylam laminated sheet top cover 3 mm thick / modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular / normal type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following :-One light point controlled by one switch |
| 3 | All as per item No. 2 above but forOne fan point controlled by one switch/regulator |
| 4 | All as per item No. 2 above but forOne light point controlled by 2 way switch |
| 5 | All as per item No. 2 above but forOne 3 pin socket out let 5 Amps on independent board |
| 6 | All as per item No. 2 above but forOne bell/buzzer point controlled by bell push |
| 7 | All as per item No. 2 above but forOne 3 pin socket out let 5 A on same board |
| 8 | Point wiring complete surface type with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories surface type wiring incl GI/ MS branded sunken boxes suitable for normal/modular concealed on walls including plastic/heylam laminated sheet top cover 3 mm thick/modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular/normal type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following :-One light point controlled by one switch |
| 9 | All as per item No. 8 above but forOne fan point controlled by one switch / regulator |
| 10 | All as per item No. 8 above but forOne light point controlled by 2 way switch |
| 11 | All as per item No. 8 above but forOne 3 pin socket out let 5 Amps on independent board |
| 12 | All as per item No. 8 above but forOne bell / buzzer point controlled by bell push |
| 13 | All as per item No. 8 above but forOne 3 pin socket out let 5 A on same board |
| 14 | All as per item No 2 but concealed wiring drawn through existing PVC conduit.One light point controlled by one switch |
| 15 | All as per item No. 14 above but forOne fan / Exhaust point controlled by one switch/regulator |
| 16 | All as per item No. 14 above but forOne light point controlled by 2 way switch |
| 17 | All as per item No. 14 above but forOne 3 pin socket out let 5 Amps on independent board |
| 18 | All as per item No. 14 above but forOne bell / buzzer point controlled by bell push |
| 19 | All as per item No. 14 above but forOne 3 pin socket out let 5 A on same board |
| 20 | Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through non-metalic existing PVC conduit medium density ISI marked incl accessories surface type run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick GI/MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. |
| 21 | Point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC Casing & Caping ISI marked incl accessories surface type wiring incl 1.6 mm thick GI/MS sunken boxes concealed on walls including laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following One light point controlled by one switch |
| 22 | All as per item No. 21 above but forOne fan point controlled by one switch / regulator |
| 23 | All as per item No. 21 above but forOne light point controlled by 2 way switch |
| 24 | All as per item No. 21 above but forOne 3 pin socket out let 5 Amps on independent board |
| 25 | All as per item No. 21 above but forOne bell / buzzer point controlled by bell push |
| 26 | All as per item No. 21 above but forOne 3 pin socket out let 5 A on same board |
| 27 | Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic PVC conduit medium density ISI marked incl accessories concealed type run on walls/ ceiling incl GI/MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. |
| 28 | Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic PVC conduit medium density ISI marked incl accessories surface type run on walls/ ceiling incl GI/MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. |
| 29 | Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC casing caping ISI marked incl incl accessories surface type wiring run on walls/ ceiling incl GI/MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.Note for Item No 21 to 29:-(i) The earth wire for the points in the same circuit can be looped from point to point(ii) Earth wire shall be taken inside the conduit(iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring(iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring.(v) Cost of cutting chases for conduits and making good to walls, in case of recessed or concealed conduit wiring will be paid separately in other items. |
| 30 | S&F in repair LED batten suitable for indoor applications 20 Watts, 4 feet with extruded aluminium housing & integrated LED channel complete with all accessories all as specified and directed. |
| 31 | S&F in repair LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel with white arcylic cover complete with all accessories i all as specified and directed. |
| 32 | S&F LED luminaries, round / square type 18 watt Surface / Recess mounted rimless round/ square downlight. Modulded in engineering plastic bst in clas high lumen output & wider distribution complete with all accessories as specified and directed. |
| 33 | S&F 2' x 2' Recess mounted LED Luminaire 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all i as specified and directed. |
| 34 | S&F Decorative, wall mounting ,champagne gold finish fixture with plastic body suitable for 9 watt LED lamp B22 base all as specified and directed by Engineer -in-Charge.. |
| 35 | Supply and Fix Modular switch 1 way 6A,1 module |
| 36 | Supply and fix Modular switch 1 way 16A, 1 module |
| 37 | Supply and fix Modular switch 2 way 6A,1 module |
| 38 | Supply and Fix Modular Bell push 6A 1 module |
| 39 | Supply and fix modular Socket, 6A - 2/3 pin combined 2 module |
| 40 | Supply and fix modular Socket 6A/16A - 2/3 pin combined 2 module, |
| 41 | Supply and fix modular type Fan step regulator, 120W - 2 module |
| 42 | S&F of of Switch piano flush button single pole two way 5 Amps all as specified and as directed. |
| 43 | S&F of Angle holder PVC/polycarbonate type all as specified and as directed |
| 44 | S&F of switch piano flush type single pole one way 5 Amps |
| 45 | S&F of switch socket combination 5 pin 2 in 1, 5 A Flush type all as specified and as directed |
| 46 | S&F of switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal all as specified and as directed |
| 47 | S&F of bell push flush type 5A all as specified and as directed . |
| 48 | S&Fin repair of MCB SPN 240 volts 32/40 Amps complete all as specified and as directed |
| 49 | S&F in repair of MCB single pole 240 volts 10/16/20/32 Amps complete all as specified and as directed |
| 50 | S&F in repair of MCB TPN 415 volts, 10KA 'C' curve 63 Amps complete all as specified and as directed |
| 51 | S&F in repair of MCB TPN 415 volts, 10KA 'C' curve 100 Amps complete all as specified and as directed |
| 52 | S&Fin repair of MCB DB SPN 4 way double door type 240 volts with 200 Amps rated busbar as specified and as directed. |
| 53 | S&F in repair of MCB DB SPN 8 way double door type 240 volts with 200 Amps rated busbar as specified and as directed. |
| 54 | S&Fin repair of MCB DB TPN 4 way with double door type 415 volts with 200 Amps rated busbar for housing MCBs as specified and as directed. |
| 55 | S&F ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed |
| 56 | S&F stepped type electronic fan regulator flush Switch/socket type all as specified and as directed |
| 57 | S&Fin repair of Ding Dong bell AC 230 volts single pole. |
| 58 | Removing of old existing and provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 6 Sqmm along with 6 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed |
| 59 | Removing of old existing and provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 4 Sqmm along with 4 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed |
| 60 | Removing of old existing and provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 2.5 Sqmm along with 2.5 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed |
| 61 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed including dismantaling and taking down old Earthing plates. |
| 62 | Supply and fixing in repair 30 W LED bldg security light fitting with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection including taking out old fittings. |
| 63 | S&F in repair of Bracket made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer including removing the old existing GI bracket from bldg complete all as specified and directed. |
| 64 | M & L excavation in trenches in hard/dense soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables on trenchs etc complete all as specified and as directed. |
| 65 | M & L for returning, filling in trenches incl spreading leveling watering and well ramming in layers with hard/dense soil not exc 25 cm thick in each layer complete as specified and as directed |
| 66 | M & L for removing excavated soil to a distance not exc 1.5 mtr above the starting point complete all as specified and as directed |
| 67 | M & L for sand cushioning with a layer of M-sand 23 cm thick under and above the cable complete all as specified and as directed |
| 68 | S & L sub class burnt bricks for cable protection complete as specified as directed |
| 69 | S&L cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor connected with suitable legs including neccessary roadcrossing if applicable and taking out the existing unserviceable cable for following size :-2 C x 10 Sqmm |
| 70 | All as per item No. 69 above but for4 C x 16 Sqmm |
| 71 | All as per item No. 69 above but for3.5 C x 25 Sqmm |
| 72 | M&L for GI tubing light grade 40mm dia with all accessories for cable protection fixed on poles / bldgs / road and laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed. |
| 73 | S&F in repair Bulk Head Fitting suitable for indoor application of 10 watt, including electrical connecion from ceiling rose with 3 core 1.5 sqmm sheathed wire all as directed. |
| 74 | S&F in repair LED Bulb suitable for indoor application of 9 watt, to fit in Angle Holder or Decorative wall light fixture all as directed. |
| 75 | S&F in replacement PVC Fresh air fan of 200 mm sweep 1200/1400 RPM with louver complete including necessary core cutting arrangement for installation all as specified and directed. Please Enable Macros to View BoQ information |
| 76 | S&F in replacement PVC Fresh air fan of 200 mm sweep 1200/1400 RPM with louver complete including necessary core cutting arrangement for installation all as specified and directed. Please Enable Macros to View BoQ information |