| 1 | M&L Surface dressing n.exc 15 cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Excavation in post holes (or similar holes) n. exc 0.5 cum each & getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm thick each layer watering and removing surplus soil to a distance n. exc 50mtr and making good surface in soft/loose soil complete all as specified and directed. |
| 3 | M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 5 | M&L for angle iron posts and struts in fencing including cutting tops to shape (swan neck) or as directed, drilling holes, notching for wire, etc flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work including flat iron for holding chain link fencing conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 6 | Mild steel round bars Fe-410-W (Gde.E-250) quality-A or Fe 290Gde, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 7 | M&L for 5 to 10 mm dia mild steel screw bolts, with hexogonal or square at one end and srewd the other or screwd both ends each screwd end to be fitted with washer and one hexogonal or square length exc 5cm and n. exc 10 cm complete all as specified and directed. |
| 8 | M&L for preparation or new steel and iron surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 9 | Fixing only galvanised chain link fencing of GI wire including line wire standards rails straining bolts etc including provision of binding wire and mesh size as per direction of GE Gwalior & complete all as specified and directed. |
| 10 | Supply only PVC Coated galvanised chain link fencing GI wire including line wire standards rails straining bolts etc including provision of binding wire and mesh size as per direction of GE Gwalior & complete all as specified and directed. |
| 11 | S&F for Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed. |
| 12 | Desilting and cleaning of drain of width not exceeding 30 cm and average depth not exceeding 30 cm, including removal of silt, sludge, garbage, and other deposited materials from the bed and sides of the drain. The work includes lifting, collecting, and disposing of the excavated material to a designated dumping site within all leads and lifts complete all as specified and directed. |
| 13 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 14 | M&L for brick work with sub class 'B' bricks (old size) straight or curved on plan, exc. 6m mean radius built, in cement mortar 1:6 as in manholes, septic tanks, soakage pits, drain etc in any position complete all as specified and directed. |
| 15 | M & L for brick work with sub class `B' bricks, straight or curved on plan, exc 6m mean radius, (except bricks) built in cement mortar 1:6 complete all as specified and directed. |
| 16 | M&L PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in surface channel,wall coping, and mass concrete etc, complete all as specified and directed. |
| 17 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends complete all as specified and directed. |
| 18 | Add or deduct for each 25 mm girth or part thereof over or under 30cm in above item complete all as specified and directed. |
| 19 | Taking down cement plaster any description on brick or stone walls, /RCC walls surfaces etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified & as directed. |
| 20 | M&L for 15 mm thick rendering on Brick masonry or other than fair faces of brick wall For External CM 1:6 finished even and fair without using extra cement, complete all as specified and directed. |
| 21 | M&L for two coats of cement base paint on new plastered surfaces complete all as specified and as directed. |
| 22 | Demolition of cement concrete (un reinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level) complete all as specifeid and directed |
| 23 | M&L hard core of for broken stone boulder of gauge n.exc 63mm deposited, spread and levelled in layers n.exc 15 cm thick watered and rammed to a true surfaces complete all as specified and directed. |
| 24 | M&L for 100mm thick Cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) complete all as specified and directed. |
| 25 | Providing and laying 60mm thick laquer finish (ISI Marked) factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 26 | Providing and laying 80mm thick laquer finish (ISI Marked) factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 27 | M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed |
| 28 | M&L for repair to pot holes any depth n. exc 4.00 Sqm each including sweeping free from dust and mud or water, scoring sunken surfaces in road, cutting around edges to at least 25mm in depth, putting in ready mix cold road patching premix as specified for thin premixed carpet (30mm thick) filled up to the top level of existing road , well rammed (including supply of materials) and compacted with hand roller , depth of pot holes not exc 40 mm (averaging 30mm thick). Note:- Pot holes shall be marked by Engineer-in-Charge before commencement of work and the same shall be entered in MB after making good and before laying of cold road patch carpet. |
| 29 | M&L preparation or new concrete surfaces of any description and applying two coats of plastic emulsion paint over a coat of primer complete all as specified and directed. |
| 30 | M&L preparation of old concrete surfaces of any description and applying one coat of plastic emulsion paint complete all as specified and directed. Please Enable Macros to View BoQ information |