| 1 | M&L for getting out clearly all grass vegetation, saplings, shrubs, bush, wood, undergrown roots, and trees not exceeding 30 cm girth and removing rubbish outside the periphery of the PH area under clearance including surface dressing complete all as specified & directed. |
| 2 | M&L for pruning of trees and cutting of newborn trees/bushes (any height) located inside pump house premises/on the roof of pump house complete all as specified & directed. |
| 3 | Cleaning of valve pit chambers inside Pump Houses including removal of mud, dust, debris, stagnant water etc complete all as specified & directed. |
| 4 | M&L for painting of motor body of any size and capacity using synthetic enamel paint with one coat as directed by Engr-in-charge including preparation of old surfaces complete all as specified & directed. |
| 5 | M&L for painting iron surfaces of pipes, NRV & sluice valves connected to motor running toward OHT of size 4\\"/6\\"/8\\" dia from pump using synthetic enamel black paint with one coat including preparation of old surface before application of paint complete all as specified & directed. |
| 6 | Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified & directed. |
| 7 | Testing of water sample , chemical, biological and physical including hardness, turbidity, E-coli, coliform all as directed by Engr-in-charge from a NABL accredited lab Note:- Contactor shall arrange for collection of sample as and when directed from pump houses / any other source & including provn of clean glass container properly sealed and send the same to the lab with - in 04 hrs of collection. |
| 8 | Excavation in trenches in soft/lose soil n.exc. 1.5M wide & n exc 1.5M deep for laying of GI/CI pipe line & getting out including forming bottom surface complete all as specified & directed. |
| 9 | Returning, filling in, trenches including spreading, levelling, watering and well ramming in layer n.exc. 250 mm in any type of soil after the pipe laid & tested complete all as specified and directed. |
| 10 | Removing excavated surplus soil to a distance n.exc. 50mtr and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified & directed. |
| 11 | Disconnecting and taking up old existing GI water tubing and connection / grade and in any position of trenches / under floors/ on walls etc including connected fitting/ accessories and fixtures such as bend, Tee, Union,Valve etc, all as directed and specified for the following sizes :- |
| 12 | 50mm dia |
| 13 | 40mm dia |
| 14 | 25mm dia |
| 15 | 20mm dia |
| 16 | 15mm dia |
| 17 | S & F GI Tubes, 'Medium grade', galvanised, with all fitting; laid in trenches complete all as specified & directed for the following size:- |
| 18 | 50mm dia bore |
| 19 | 40mm dia bore |
| 20 | 25mm dia bore |
| 21 | S & F GI Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified & directed, for the following size:- |
| 22 | 20mm dia bore |
| 23 | 15 mm dia bore |
| 24 | M&L to Supply, installation, testing and commissioning of Sluice valves flanged of class 1.6 PN with stainless steel spindle, nuts, bolts washer etc including taking out old UNSV sluice valve complete all as specified and as directed as per following sizes: |
| 25 | 150mm dia bore |
| 26 | 100mm dia bore |
| 27 | S&F Gun metal, glove or gate valves with iron wheel head, screwed both ends for GI pipe 50mm dia including taking out old unsv complete all as specified and directted. |
| 28 | S&F Gun metal, glove or gate valves with iron wheel head, screwed both ends for GI pipe 40mm dia including taking out old unsv complete all as specified and directted. |
| 29 | S&F Gun metal, glove or gate valves with iron wheel head, screwed both ends for GI pipe 25mm dia including taking out old unsv complete all as specified and directted. |
| 30 | S&F Gun metal, glove or gate valves with iron wheel head, screwed both ends for GI pipe 20mm dia including taking out old unsv complete all as specified and directted. |
| 31 | S&F Gun metal, glove or gate valves with iron wheel head, screwed both ends for GI pipe 15mm dia including taking out old unsv complete all as specified and directed. |
| 32 | Supply and fixing in repair Bib taps 20 mm dia, PTMT any colour, high pressure screwed for iron pipes and fixed to pipe (Minimum weight 15mm-90gms/20mm 125gms) fixed in repair complete all as specified & directed. |
| 33 | S & F in repair long length CI Detachable joint complete with nuts, bolts, washers and rubber ring (Set) suitable for 150 mm nominal bore CI/DI pipe complete all as specified & directed. |
| 34 | S & F in repair long length CI Detachable joint complete with nuts, bolts, washers and rubber ring (Set) suitable for100 mm nominal bore CI/DI pipe complete all as specified & directed. |
| 35 | S & F in repair long length CI Detachable joint complete with nuts, bolts, washers and rubber ring (Set) suitable for 80 mm nominal bore CI/DI pipe complete all as specified & directed. |
| 36 | S & F in repair long length CI Detachable joint complete with nuts, bolts, washers and rubber ring (Set) suitable for 50 mm nominal bore CI/DI pipe complete all as specified & directed. |
| 37 | S&F in repairs cast iron non return valve, both ends flanged jointed, ISI marked, of approved quality and tested complete all as specified and directed of following sizes :-. |
| 38 | 200mm dia bore |
| 39 | 150mm dia bore |
| 40 | 100mm dia bore |
| 41 | Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for taking credit and making good disturbed surfaces of walls, floors etc. |
| 42 | M&L for point wiring in PVC casing caping/concealed/conduit with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLSH cable of size 1.5 Sqmm as earth continuity conductor. |
| 43 | One light point/fan point/Ex fan point controlled by one 5 Amps switch one way |
| 44 | One 3 pin 5 Amp switch socket outlet on independent board |
| 45 | One 3 pin 5 Amp switch socket outlet on same board with accessories |
| 46 | M&L for point wiring in PVC casing caping/concealed/conduit with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor. |
| 47 | S&F in repair switch piano Flush type, single pole, one way 6 amp 240 volts, complete all as specified and as directed. |
| 48 | S&F in repair Socket outlet 2 in 1, 3 pin, 6 Amps, flush type complete all as specified and as directed. |
| 49 | S&F in repair Switch socket combination 2 in1, 3 pin, 6 and 16 Amp flush type,universsal complete all as specified and as directed. |
| 50 | S&F in repairs stepped type electronic fan regulator for ceiling fan 1200/1400mm size,230 volts,6 Amps, complete all as specified & directed. |
| 51 | Supply and fix in repair ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body complete all as specified and directed. |
| 52 | S&F in repair Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed. |
| 53 | Supply and fix in repair LED inverter bulb 12W complete all as specified and directed. |
| 54 | S & F in repair decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, environmental friendly, 1x22 W, 230 Volt aluminium LED lighting fixture with high lumen output, environmental friendly, complete all as specified and directed. |
| 55 | Supply and fix in repair exhaust fan, plastic body AC single Phase copper winding, 230V 50Hz of size 150mm sweep with, blades, and frame and louver including taking out old unsv and depositing in MES store complete all as specified and directed. |
| 56 | S&F in repairs Double door metallic sheet metal enclosure for DB MCBs SPN 4 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified & directed. |
| 57 | S&F in repairs Double door metallic sheet metal enclosure for DB MCBs SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified & directed. |
| 58 | S & F in repairs MCB, SPN 32 Amps 240 Volts C curve, complete all as specified and as directed. |
| 59 | S & F in repairs MCB SP 6 to 32 Amps, 240 Volts, C Curve complete all as specified and directed. |
| 60 | M&L for sub main wiring with two run single core 4 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia PVC conduit/casing caping, medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc complete all as directed. Note: Two runs of 4 sqmm and one run of 4 sqmm cable and one run of casing capping shall be measured as one RM |
| 61 | S&F in repair 1100 V grade heavy duty cable with pvc insulated aluminium conductor served with an inner sheathing of pvc tape and overall pvc sheathed in service connection suspended by insulating hangers not more than 1mtr apart including 4mm suspension wire two single core cable flat or circular of size 6 sqmm including taking taking out old unsv complete all as specified and directed. |
| 62 | Supply and fixing in repair ceiling fans complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cageinduction motor, complete all as specified and directed by Engr-in-charge. |
| 63 | M&L for disconnecting of chloronome plant from main raising line including all INPUT/OUTPUT water supply pipes and electric connections from LT panel to repair/replace of following old UNSV parts:- |
| 64 | M & L in repair of NRV made of brass as existing suitable size complete all as specified & directed. |
| 65 | M & L in repair of union as per existing suitable size complete all as specified & directed. |
| 66 | M & L in repair of elbow as per existing suitable size complete all as specified & directed. |
| 67 | M & L in repair of ball valve of CPVC as per existing suitable size complete all as specified & directed. |
| 68 | M & L in repair of connector as per existing suitable size ccomplete all as specified & directed. |
| 69 | M & L in repair of SS aegitator complete with rotator fan and all connected accessories as per existing suitable size complete all as specified & directed. |
| 70 | M & L in repair of MTA of dozer as per existing suitable size complete all as specified & directed. |
| 71 | M & L in repair of FTA of dozer as per existing suitable size complete all as specified & directed. |
| 72 | M & L in repair of motor bush after opening of complete motor nut and bolts as per existing/suitable size complete all as specified & directed. |
| 73 | M & L in repair of chlorine injector pump as per existing/suitable size complete all as specified & directed. |
| 74 | M & L in repair of star coupling as per existing suitable size complete all as specified & directed. |
| 75 | M & L in repair of CPVC pipes of high grade as per existing suitable size complete all as specified & directed. |
| 76 | M & L in repair of FRP tank of dozer as per existing/suitable size and capacity complete all as specified & directed. |
| 77 | M & L in repair of UNSV DOL starter three phase suitable for 220 V, 50 Hz, motor upto 2 to 3 HP capacity complete all as specified & directed. Make L&T , Havells /Shalabh India Ltd |
| 78 | M & L in repair of UNSV 3 phase electric motor as per existing make & capacity suitable for 220 V, 50 Hz, complete all as specified & directed. |
| 79 | S & F in repairs MCB, TPN 16 Amps 240 Volts C curve, complete all as specified & directed. |
| 80 | S & F in repairs diaphram of chloronome pump as per existing make and model complete all as specified & directed. |
| 81 | M&L for assembling of chloronome plant including all INPUT/OUTPUT water supply connections and electric connections, to make functional complete all as specified & directed. Please Enable Macros to View BoQ information |