| 1 | Excavation for foundation up to 1.50 mt. depth including sorting out and stacking of use ful materials and disposing off the excavated stuff up to 50 meter lead (A) Loose or soft soil. |
| 2 | Excavation for foundation for depth from 1.5 m to 3.0 mt. including sorting out and stacking of use ful materials and disposing off the excavated stuff up to 50 meter lead (A) Loose or soft soil. |
| 3 | Filling available excavated earth (excluding rock) in tranches plinth, sides of foundation, etc. in layers not exceeding 20 cm in depth. Consolidating each deposited layer by ramming and watering. |
| 4 | Filling in foundation and plinth with murrum or selected soil in layers of 20cm. Thickness including watering, ramming and consolidating etc. complete. |
| 5 | Providing and laying RUBBLE SOLING wherever required in foundation and plinth including hand packing filling interstices with chips and sand. Watering and compacting to Consolidated thickness, etc. complete as directed by engineer-in-charge. |
| 6 | Providing and laying cement concrete 1:2:4 (1-Cement :3-Coarse sand :4-graded stone aggregates 20mm nominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth (more than 10 ton). |
| 7 | Providing and laying controlled cement concrete M-200 and curing complete excluding the cost of from work and reinforcement for reinforced concrete work in (A) Foundation, footings, Base of columns and Mass concrete. |
| 8 | Providing and laying controlled cement concrete M-200 exposed work with curing etc. complete including the cost of formwork but excluding the cost of reinforcement for RCC work in (B) COLUMNS (i) Having cross-sectional area 0.05 to 0.08 Sq.m. |
| 9 | Providing and laying controlled cement concrete M-200 exposed work with curing etc. complete including the cost of formwork but excluding the cost of reinforcement for RCC work in (A) BEAMS (ii) Having cross-sectional area 0.08Sq.M and upto 0.12 Sq.M. |
| 10 | Providing and laying controlled cement concrete M-200 exposed work with curing etc. complete including the cost of formwork but excluding the cost of reinforcement for RCC work in (A) BEAMS :(i) Having cross-sectional area 0.05Sq.M to 0.08 Sq.M. |
| 11 | Providing and laying controlled cement concrete M.250 and curing complete including the cost of fromwork and excluding reinforcement for reinforced concrete work in Slabs, landings, shelves, balconies and cantilever slabs. (upto floor two level). |
| 12 | Providing form work of ordinary timber plankings so as to give a rough finishing including centring, shuttering, stratting and propping etc. height of propping and centering below supporting floor to ceilling not exceeding 04mm and removal of the same for in situ reinforced concrete and plain concrete work in Foundations footings Bases of columns etc. and Mass concrete. |
| 13 | Providing TMT Bar FE 500D reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level. |
| 14 | Brick work using common burnt clay building brick having crushing strength not less than 35 kg/Sq.cm. in foundation and plinth in cement mortar 1:6 (1 Cement :6 Fine sand). (B) Conventinal. |
| 15 | Providing material and labour for Brick work common burnt clay building bricks having crushing strangth not less than 35kg/sq.mt. in Superstructure above plinth level upto floor two level in cement mortar 1:5 (1 Cement : 5 fine Sand) (B) Conventional. |
| 16 | Half brick masonary in Common burnt clay building brick having Crushing strength not less than 35 Kg/Sq.Mt. in Cement Mortar 1:4 (1 Cement :4 Course sand) In foundation and plinth (B) Conventional. |
| 17 | Providing 15mm thick cement plaster in single coat on Rough (Similar) side of single or haft brick wall for interior plastering upto floor two level and finished even and smooth in (i) cement mortar 1:3 (1 Cement :3 Sand). |
| 18 | Providing 10mm thick cement plaster in single coat for plastering on ceiling and softs of stairs upto floor two level and finished even and smooth in (i) cement mortar 1:3 (1 Cement :3 Sand) and finishing with a floating coat of neat cement slurry. |
| 19 | Providing and Fixing FRP frame size 125 x 65mm and 35mm thick FRP shutter with wood grain raised pannel dising Finishing shutter having extra reinforcement on sides and edges and in Gel coat Finish. The core of the shutter is to be Filled up with injected fire polyurethene foam done in situ along with embaded wooden places for stiffening and also for taking hinges and fixtures. The whole FRP frame & shutter is to be water proof, weather proof, termite proof and resistance to mild acid/Aakali. Rates are to be inclusive of S.S. hinges with fastener sleeve & alluminium fixtures & fastenings. |
| 20 | Providing and laying white glazed tiles 6mm thick in flooring treads of steps and landing laid on a bed of 12mm thick cement plaster 1:3 (1 cement :3 Course sand) finished with flush pointing in White cement. |
| 21 | Providing and laying white glazed tiles 6mm thick in skrting risers of steps and dedo on 10mm thick cement plaster 1:3 (1 cement :3 Couse sand) and jointed with White cement slurry. |
| 22 | Distempering (Three Coats) with oil bound washable distemper of approved brand and manufacture and of required shade on wall surfaces to give and even shade, over and including a priming coat with alkari resistance primer of approved brand after throughly brushing the surface and other foreign matter and also including prepairing the surface even and sand prepared smooth. |
| 23 | Providing and fixing water closet squalting Pan (Indian type) W.C. pan size 580mm (Earth work, Bed concrete, foot reste and trap to be measured and paid for separetely) (A) Vitreous China. (I) Long pattern = White colour including P or S trap pair of white viterious China 250mm x 130mm x30mm foot rest to long pattern squalting pan water closet including providing and G.I. Intel connection for flush pipe for W.C. Pan. |
| 24 | Providing an fixing WASH DOWN water closet (Equopean type) W.C. pan with intergral 'P' or 'S' trap including jointing the trap with soil pipe in C.M. 1:1 (1 cement :1 sand) (Seal and cover to be measured and paid for seperately) (A) Viterous China Pattern (i) in white colour including and fixing 12.5 Liters low level flushing cistern with apair, of C.I. or Mild brackets complete with fitting such as lead valve less syphon, 15mm nominal size brass ball valve with polythene float, C.P. brass handle union and couplings for connections with all titting etc. complete. |
| 25 | Providing and fixing WASH BASIN with single hole for pillar tap with C.I. Or M.S. brackets painted white including cutting holes and making good the same but excluding fittings (A) Vitreous China (ii) Flat Back washbasin 550 mm x v 400mm size (i) In white coour. Providing and Fixing C.P. brass waste for Wash Basin or sink. (A) 32mm dia Providing and Fixing M.I. fisher union for washbasin or sink. (A) 32mm dia. |
| 26 | Providing and fixing Urinal of approved quality including connection the Urinal with waste pipe, trap etc. complete (A) White earthenware flat back or corner tupe size 430mm x 260mm x 350mm. Providing and Fixing chromium plated bottle trap with necessary couplings of approved quality for wash basin. |
| 27 | Providing & fixing CAST IRON (Spun) NAHNI TRAPS of the following nominal dia meter of self ciening desingn with C.I. Screased down or hings gratting incutting coast of cutting and making good the walls and floors 100mm, Inlet and 50mm outlet. (C) 100mm dia. |
| 28 | Constructing brick masonry chamber for underground C.I. Inspection chamber and bends with bricks having crushing strength not less than 35 Kg./Cm2 in C.M. 1:5 C.I. cover with frame (light duty) 455 x 610mm intenal diamensions total weight of cover with frame to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg.) (RCC top slabe with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm size) foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete (i) Inside dimensions 455mm x 610mm and 450mm deep for single pipeline. |
| 29 | (B) Providing SOCK PIT of 5.00 cu.mt. Volume including excavating and filling brickbats with dry masonary work at top for 45 cm. height including covering the top with stone including providing vatas in C.M. 1:3 with finishing curing etc. complete as directed. |
| 30 | Providing and supplying in standard length ISI mark rigid unplsticised PVC pipes suitable for potable water with ring fit joint including cost of rings as per IS specification no.4985/1988 including all local central taxes, ransportation, freight charges, octroi, inspection charges, loading unloading, conveyance to the departmental stores and including cost of jointing meterial etc. complete Test Pressure 6Kg/Cm2 110mm dia. |
| 31 | Providing and fixing to Wall, Ceiling and Floor galvanised Mild steel tube (Medium grades) of the following nominal bore, tube fitting and clamp including making good the wall ceiling and floor. (C) 25mm dia. |
| 32 | Providing and fixing to wall, ceiling and floor galvanised Mild steel tube (Medium grades) of the following nominal bore, tube fitting and clamp including making good the Ceiling and floor. (E) 40mm dia. |
| 33 | Providing and fixing brass screw down stop tap. (A)15mm dia. |
| 34 | Providing and fixing pillar tap, Capstan head, Screw down high pressure with screws, shanks and back nuts 15mm dia. |
| 35 | Providing and Fixing screw down bib taps of following size (A) Brass screw down bib tap polished bright. (i) 15mm dia. |
| 36 | Providing and fixing Gun Metal check or Non return fall way wheel valve. (C) 25mm dia. |
| 37 | Providing erecting and fixing double coated ISI water tank of required capacity each with all necessary fitting and connection etc. complete on terrace. |
| 38 | Providing and laying marble stone slab flooring over 20mm (average) base of cement mortar 1:6 (1 cement :6 coarse sand) or L.M. 1:1:5 (1 - lime putty : 1:5 coarse sand) laid and jointed with gray cement slurry including rubbing and polishing complete (A) Marble slab 25mm thick. |
| 39 | Providing and fixing M.S. grills of required pattern to wooden frames of windows etc. with M.S. flats at required spacings and frame alround, square or round bars with round headed bolts and nuts or by screws (A) Plain Grill. |
| 40 | Painting two coats (Including priming coat) on new steel and other metal surface with enamel paint, brushing, interior to give an even shade including cleaning the surface an even shade including cleaning the surface of all dirt, dust and other foreign matter. |
| 41 | Point wiring for independent PLUG with following size mains earth wire of 1.5 sq.mm 9green) both are of ISI marked 1.1 KV grade FRLS PVC insulated julti strand copper wires upto 10 mt length, in following below of pipe erected complete with ISI Marked 3/5 Pin socket and tissino type switch erected with earth continuity connection erected on Metal/PVC/Wooden box covered with 3 mm thick PC (Polycarbonate)/Acrylic/Laminated sheet. (i) partial PVC pipe and drops in oval conduit / PVC casing capping erected concealed in wall/ceiling complete. |
| 42 | Providing following type of Modular Type Accessories mounted with PVC/ metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate, modules erected with necessary connections as per site situation directed by Engineer In charge. (2) One No 5 pin plug Cat.II |
| 43 | Providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required. (c) One wire 1.50 sq.mm. |
| 44 | Providing & erecting 415V MCB Four Pole Switch for Lighting Load (B curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity. (a) 6 to 32 Amp. Cat.I. |
| 45 | Supplying & erecting earth pit of minimum bore dia. 150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications with chamber and heavy duty cover. (A) (approved make OEM has to submit test certificate including value of earth resistance of installation duly stamped and signed by agency and officer Incharge has to ensure the value of earthing resistane mentioned in test Certificate( & having back filling compound of (B) Inner chemical (CCM Compund) - Resistivit:- 0.2 ohm / meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry from, Sulphar content:-<2%(C) Back fill Compound :- Earthing compound should be capable to retain moisture for long time Necessary test report must be submitted by Agency. (a) For Electrical Installation up to 440V in normal soil. Length of pipe - 1 Mtr Back filling compound - 1 Nos Bag of 15 Kg. |
| 46 | Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steet conforming to IS: 513/CRCA/ aluminium die cast powder coated and high U.V. & corrosion resistance with diffuser with company mark/name 160V to 270V, Power Factor more than 0.95, THD < 15%, CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt, LED LED driver efficiency > 85% (fitting required LM-79 & LM-80 Certificates) (NOTE: Below description have shown ranges of Wattage capacity of LED fittings. The Engineer incharge many select any wattage capacity between the ranges shown) (iiI) 18-20 Watts, Surge - 2KV, IP-20, converntional 4 feet Cat-III. (Philips, crompton, Syska). |
| 47 | Providing and fixing 18mm thick machine cut, mirror/egg shell polished, Granite stone work of approved shape, size, color, design and pattern as per approved architect for wall lining (veneer work) including dao, skirting, risers of steps, door / window sill and four side windows, lift facade, ledges, etc., including edge moulding, rounding the dges etc. wherever requiredas per design & grooves and mulds truly in plumb in required design and pattern wherever required, stones of different finished surface textures, on 12mm (average) thick cement mortar 1:3 (1 cement : 3 coarse san) laid and jointed with white cement slurry @ 3.3 Kg/Sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing, removing any unevenness on the surface etc all complete as per Architectural drawings, and as directed by the Engineer-inc-Charge for all lift, all floor leves, all heights and leads. The item to include all material, fixing, scaffolding, labour, Wastage etc. complete in all respects Required test shall be done as per relavent IS Code. Note: No extra payment pay for architectural Ornamental Design upto 10% of flooring area. Rate shall be inclusive of cutting of slab in any shape, at any level for service cutout COMPLETE ETC. |
| 48 | Providing material and labour for laying water proofing over R.C.C. Slab consisting first Layer of special water proofing compound 1 Kg/10 sq.mt. mixed with Cement slurry spreded over maked slab and second layer of leveling Coarse of C:M 1:3 (1 cement :3 fine sand) of 25mm (a.v) bed thickness. Third layer consisting of brick aggregates of 75mm (a.v) thickness mix with 50% cement mortar 1:3 for joint filling and top finish having 10mm average thickness and exposed top smooth finishing with cement slurry including making false chequired 300mm x 30mm in size. The treatment is to be carried alongwith the vertical surface of the parapet and other joining wall upto height of about 200mm in a shape of quarter round vata including curing etc. complete as per specification. UPTO FLOOR TWO LEVEL. Water proofing compound having I.S.I. MARK of ISO mark should be used wherever cement used and no extra payment will be made for vata, curvature etc. only fiat surface area will be consider for payment. Please Enable Macros to View BoQ information |