| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:- |
| 2 | Short Point :- |
| 3 | Medium Point :- |
| 4 | Long Point :- |
| 5 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 6 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 7 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- |
| 8 | 1 X 1.5 sq mm |
| 9 | 1 X 2.5 sq mm |
| 10 | 1 X 4 sq mm |
| 11 | 1 X 6 sq mm |
| 12 | 1 X 10 sq mm |
| 13 | 2 X 1.5 sq mm |
| 14 | 2 X 2.5 sq mm |
| 15 | 2 X 4 sq mm |
| 16 | 2 X 6 sq mm |
| 17 | 2 X 10 sq mm |
| 18 | 4 X 4 sq mm |
| 19 | 4 X 6 sq mm |
| 20 | 4 X 10 sq mm |
| 21 | 4 X 16 sq mm |
| 22 | Supplying and fixing of the following PVC casing capping with all accessories etc. as required:- |
| 23 | 20mm x 12mm |
| 24 | 25mm x 12mm |
| 25 | Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required:- |
| 26 | 19/20 mm dia |
| 27 | 25 mm dia |
| 28 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required:- |
| 29 | 2 X 1.5 sq mm |
| 30 | 2 X 2.5 sq mm |
| 31 | 4 X 6 sq mm |
| 32 | Wiring for Circuit/Sub-main with the following sizes PVC insulated Copper conductor cable (FR) in PVC conduit including connection etc. as required:- |
| 33 | 2 X 1.5 sq mm |
| 34 | 2 X 2.5 sq mm |
| 35 | 4 X 6 sq mm |
| 36 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required:- |
| 37 | Pandent holder |
| 38 | Angle/batten holder |
| 39 | Ceiling rose |
| 40 | Ding dong call bell |
| 41 | Remote controlled call bell |
| 42 | 2.5 mfd fan capacitor |
| 43 | 5 amps power top:- |
| 44 | 15 amps power top:- |
| 45 | Side holder for FTL/T5 |
| 46 | Side holder for pin type CFL |
| 47 | Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required:- |
| 48 | 1-2 module plastic switch board:- |
| 49 | 3 module plastic switch board:- |
| 50 | 4 module plastic switch board:- |
| 51 | 6 module plastic switch board:- |
| 52 | 8 module plastic switch board:- |
| 53 | 12 module plastic switch board:- |
| 54 | Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required:- |
| 55 | 1-2 module :- |
| 56 | 3 module :- |
| 57 | 4 module :- |
| 58 | 6 module :- |
| 59 | 8 module :- |
| 60 | 12 module :- |
| 61 | Supplying and fixing of the following modular accessories including necessary connection etc. as required:- |
| 62 | 6/10 amps one way SP switch (1M) :- |
| 63 | 6/10 amps two way SP switch (1M) :- |
| 64 | 16/20 amps one way SP switch (1M) :- |
| 65 | Bell push SP (1M) :- |
| 66 | 32 amps one way DP switch (2M):- |
| 67 | 3 pin 6/10 amps socket outlet (2M):- |
| 68 | 3/6 pin 16/20 amps socket outlet (2M):- |
| 69 | 5 step fan regulator (2M):- |
| 70 | RJ11 telephone socket outlet (1M):- |
| 71 | RJ45 LAN socket outlet (1M):- |
| 72 | TV socket outlet (1M):- |
| 73 | Switch board indicator lamp (1M):- |
| 74 | Blank plate (1M):- |
| 75 | 20/25 amps single phase motor starter switch (2M):- |
| 76 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W):- |
| 77 | Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length (up to 30 cm) by 2 x 1.5 Sq.mm PVC insulated copper conductor cable(FR) etc as required:- |
| 78 | Supplying and fixing of 500 mm metallic body pedestal fan as per cat no-BRIZSTAR FARRATA 20\\" of Crompton ( similar specification of Havells / USHA) |
| 79 | Supplying & installation of 400 mm sweep AC wall mounting fan with metal blade including connection etc as required:- |
| 80 | Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:- |
| 81 | Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required:- |
| 82 | Supplying & installation of 300 mm sweep 900 rpm metalic body exhaust fan including connection etc as required (ISI marked) :- |
| 83 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:- |
| 84 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required:- |
| 85 | Dismantling the existing ceiling fan and making winding by (34/35/36 S.W.G) Copper wire, varnish, oiling, greasing and re-fixing the same including wiring the down rod of standard length ( up to 30 cm ) etc. as required:- |
| 86 | Supplying and fixing of following room heater complete with 15 amps top including necessary connection etc as required:- |
| 87 | 1000/1500/2000/2500 watt blower type room heater:- |
| 88 | Supplying and fixing of following vertical storage water heater 5 star catagory complete with 15 amps top, connection pipes including necessary connection etc as required. |
| 89 | 25 litre storage capacity:- |
| 90 | Supplying and fixing of following luminaries complete with necessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours):- |
| 91 | Decorative wall mounting fancy bracket light fixture suitable for GLS or retrofit CFL/LED (without lamp):- |
| 92 | Supplying and fixing of the following Lamps & accessories including connection etc. as required:- |
| 93 | 36/40 watt T-8/T-12 FTL lamp:- |
| 94 | 14/15 watt retrofit CFL:- |
| 95 | 18/20 watt retrofit CFL:- |
| 96 | 23/25 watt retrofit CFL:- |
| 97 | 13 watt CFL 2 pin/4pin PL lamp :- |
| 98 | 36/40 watt electronic ballast:- |
| 99 | FTL starter:- |
| 100 | 18/20 watt T-8/T-12 FTL lamp:- |
| 101 | 14/28 watt T-5 lamp:- |
| 102 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 103 | Surface mounted integrated 20 watt LED batten with polycarbonate diffuser:- |
| 104 | Recessed/Surface mounted 2ft x 2ft decorative 36 watt LED panel light with integral driver and high quality polycarbonate diffuser:- |
| 105 | Recessed/Surface mounted 1ft x 1ft decorative 16/18 watt LED panel light with integral driver and high quality polycarbonate diffuser:- |
| 106 | Recessed round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 107 | Recessed round/Square shaped 18 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 108 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 109 | 36 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 110 | 45 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 111 | 60 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 112 | 90 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 113 | 120 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 114 | 120 watt LED flood light fixture with integral driver and secondary lens (IP 66):- |
| 115 | 6 watt/10 watt LED Bulkhead light with high quality polycarbonate diffuser (IP 65):- |
| 116 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:- |
| 117 | 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 118 | 12 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 119 | 18 watt LED PL-Lamp with integral driver and high quality polycarbonate diffuser :- |
| 120 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required:- |
| 121 | 2 way SPN MCB DB (single door):- |
| 122 | 4 way SPN MCB DB (double door):- |
| 123 | 6 way horizontal TPN MCB DB (Double door):- |
| 124 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:- |
| 125 | 6 to 32 amps SP MCB:- |
| 126 | 6 to 32 amps DP MCB:- |
| 127 | 40/50/63 amps TP MCB:- |
| 128 | 40/50/63 amps TPN MCB:- |
| 129 | 40/50/63 amps FP MCB:- |
| 130 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required:- |
| 131 | 3 core 4 Sq mm |
| 132 | 4 core 16 Sq mm |
| 133 | 4 core 25 Sq mm |
| 134 | 4 core 4 Sq mm |
| 135 | Supplying and laying of following sizes XLPE insulated PVC sheathed copper conductor Un-armoured cable including necessary connection etc as required. |
| 136 | 3 core 1.5 Sq mm |
| 137 | 3 core 2.5 Sq mm |
| 138 | 4 core 4 Sq mm |
| 139 | Supplying & fixing of 12mm thick marine plywood conforming to IS:710 with necessary painting etc as required:- |
| 140 | Excavation of earth for cable trench of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks per metre for protection including ramming, consolidating to the original shape as per dirrection of Site Engineer :- |
| 141 | Drawing of armoured/un-armoured cable with proper saddling etc as required:- |
| 142 | Supplying & installation of Digital timer Switch including necessary connection etc as required:- |
| 143 | Supplying & installation of Astronomical timer Switch including necessary connection etc as required:- |
| 144 | Supplying and laying of following sizes XLPE insulated PVC sheathed copper conductor Un-armoured cable including necessary connection etc as required. |
| 145 | 3 pole 18 amps (AC3) power contactors with 1NO+1NC Aux. Contact. |
| 146 | Supplying, installation, testing and commissioning of following ratings Valve regulated lead acid(VRLA) battery with all accessories including necessary connections etc. as required:- |
| 147 | 12 V/ 180AH tall tubular/ flat plate Battery:- |
| 148 | Cleaning of existing ceiling fan/luminaries. |
| 149 | Comprehensive AMC (CAMC) and preventive maintenance (quarterly visit during the CAMC period) of existing 3 nos. 2 KVA, 1-phase online UPS installed at New Rabhavan:- |
| 150 | Supplying, installation, testing and commissioning of Splitter & Booster unit for DMX signal including all other necessary accessories & connections etc. as required (Make:- WIPRO [Cat No:- WL-SPL 26] or with same specification of JAQUAR / PHILLIPS):- |
| 151 | Providing skilled wireman/ electrician for all days of a month including sundays and national holidays for upkeeping & mtc. of the existing electrical light fixtures, fan, outdoor lights, feeder pillars, and Main electrical panel, distribution panel including replacement of defective items and additional IE works etc. and upkeeping of the DG sets as per the directions of the Engineer-in-charge:- |
| 152 | 01 (one) Higher skilled / Electrician [Morning shift from 6:00 AM to 10:00 AM = 4 Hours & Evening shift from 5:30 PM to 9:30 PM = 4 Hours] |
| 153 | 01 (one) semi-skilled wireman [Morning shift from 6:00 AM to 10:00 AM = 4 Hours & Evening shift from 5:30 PM to 9:30 PM = 4 Hours] |
| 154 | 01 (one) Higher skilled / Electrician [Night shift from 10:00 PM to 6:00 AM = 8 Hours] Please Enable Macros to View BoQ information |