| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with wooden switch board with bakelite cover and piano type switch including connection etc as required:- |
| 2 | Short Point :- |
| 3 | Medium Point :- |
| 4 | Long Point :- |
| 5 | Providing and fixing of 3 pin 5/6 amps plug point with piano type 5/6 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on switch board, earthing the 3rd pin etc. as required:- |
| 6 | Providing and fixing of 3/6 pin15/16 amps plug point with piano type 15/16 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable (FR) on switch board, earthing the 3rd pin etc. as required:- |
| 7 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:- |
| 8 | Short Point :- |
| 9 | Medium Point :- |
| 10 | Long Point :- |
| 11 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 12 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 13 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc conduit (medium gauge) complete with wooden switch board with bakelite cover and piano type switch including connection etc as required:- |
| 14 | Short Point :- |
| 15 | Medium Point :- |
| 16 | Long Point :- |
| 17 | Wiring for light/ fan/ exhaust fan/ call bell point with 2x1.5 sq. mm PVC insulated copper conductor cable (FR) in PVC conduit (medium gauge) recessed in slab/ wall complete with 6/10 amps modular type switch, cover plate, GI box including necessary connection etc. as required. |
| 18 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2 x 1.5 sq. mm PVC insulated Copper conductor cable (FR) on modular concealed switch board with cover plate earthing the 3rd pin etc. as required. |
| 19 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. |
| 20 | 2 X 1.5 sq mm |
| 21 | 2 X 2.5 sq mm |
| 22 | 2 X 4 sq mm |
| 23 | 2 X 6 sq mm |
| 24 | 2 X 10 sq mm |
| 25 | 4 X 4 sq mm |
| 26 | 4 X 6 sq mm |
| 27 | 4 X 10 sq mm |
| 28 | 4 X 16 sq mm |
| 29 | 4 X 25 sq mm |
| 30 | 4 X 35 sq mm |
| 31 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- |
| 32 | 1 X 1.5 sq mm |
| 33 | 1 X 2.5 sq mm |
| 34 | 1 X 4 sq mm |
| 35 | 1 X 6 sq mm |
| 36 | 1 X 10 sq mm |
| 37 | 1 X 16 sq mm |
| 38 | 4 X 70 sq mm |
| 39 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Aluminium conductor cable in existing PVC casing capping/ conduit including connection etc. as required:- |
| 40 | 2 X 4 sq mm |
| 41 | 2 X 10 sq mm |
| 42 | 4 X 16 sq mm |
| 43 | Supplying and fixing of the following PVC casing capping with all accessories etc. as required. |
| 44 | 25 x 12mm |
| 45 | 38 x 16mm |
| 46 | Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required. |
| 47 | 19/20 mm dia |
| 48 | 25 mm dia |
| 49 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
| 50 | 5/6 amps piano type switch |
| 51 | 16/20 amps piano type switch |
| 52 | 5/6 amps piano type call bell push |
| 53 | 3 pin 5/6 amps piano type socket |
| 54 | 3/6 pin 16/20 amps piano type socket |
| 55 | Angle/batten/pandent holder |
| 56 | Ceiling rose |
| 57 | Buzzer Call bell |
| 58 | Ding dong call bell |
| 59 | Musical call bell |
| 60 | Remote controlled call bell |
| 61 | 2.5 mfd fan capacitor |
| 62 | Electronic 4 step mini fan regulator |
| 63 | 3mm thick bakelite sheet |
| 64 | 5 amps power top:- |
| 65 | 15 amps power top:- |
| 66 | 32 amps DP kit kat switch:- |
| 67 | Supplying and fixing of the following sizes wooden switch boards with 3mm thick bakelite cover etc. as required. |
| 68 | 102mm x 102mm (4\\" X 4\\") :- |
| 69 | 102mm x 178mm (4\\" X 7\\") :- |
| 70 | 152mm x 203mm (6\\" X 8\\") :- |
| 71 | 203mm x 254mm (8\\" X 10\\") :- |
| 72 | 203mm x 300mm (8\\" X 12\\") :- |
| 73 | 254mm x 300mm (10\\" X 12\\") :- |
| 74 | 300mm x 380mm (12\\" X 15\\") :- |
| 75 | Supplying and fixing of the following sizes PVC switch boards with cover etc. as required. |
| 76 | 75mm x 75mm (3\\" X 3\\") :- |
| 77 | 102mm x 102mm (4\\" X 4\\") |
| 78 | 102mm x 178mm (4\\" X 7\\") :- |
| 79 | 152mm x 203mm (6\\" X 8\\") :- |
| 80 | 203mm x 254mm (8\\" X 10\\") :- |
| 81 | Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required. |
| 82 | 1-2 module plastic switch board:- |
| 83 | 3 module plastic switch board:- |
| 84 | 4 module plastic switch board:- |
| 85 | 6 module plastic switch board:- |
| 86 | 8 module plastic switch board:- |
| 87 | 12 module plastic switch board:- |
| 88 | Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required. |
| 89 | 1-2 module :- |
| 90 | 3 module :- |
| 91 | 4 module :- |
| 92 | 6 module :- |
| 93 | 8 module :- |
| 94 | 12 module :- |
| 95 | Supplying and fixing of the following modular accessories including necessary connection etc. as required. |
| 96 | 6/10 amps one way SP switch (1M) :- |
| 97 | 16/20 amps one way SP switch (1M) :- |
| 98 | Bell push SP (1M) :- |
| 99 | 3 pin 6/10 amps socket outlet (2M):- |
| 100 | 3/6 pin 16/20 amps socket outlet (2M):- |
| 101 | 3/6 pin 25 amps socket outlet (2M):- |
| 102 | 4 step fan regulator (1M):- |
| 103 | 5 step fan regulator (2M):- |
| 104 | Switch board indicator lamp (1M):- |
| 105 | Buzzer call bell (1M):- |
| 106 | Blank plate (1M):- |
| 107 | Louvers/opaque type LED foot lamp (4M):- |
| 108 | 20/25 amps single phase motor starter switch (2M):- |
| 109 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\\"x 12\\" having locking arrangement including CC work, holes on earth pipe etc. as required. |
| 110 | Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required. |
| 111 | Supplying and drawing 2.5 sq. mm Copper conductor wire along with other wire for loop earthing including connection etc. as required. |
| 112 | Supplying & fixing of 900 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) :- |
| 113 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : - |
| 114 | Supplying of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades (Without regulator) (ISI marked, BEE 1 star/minimum service value 4.0m3/min/W) : - |
| 115 | Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length (up to 30 cm) by 2 x 1.5 Sq.mm PVC insulated copper conductor cable(FR) etc as required. |
| 116 | Supplying & installation of 400 mm sweep AC padestal fan with plastic blade including connection etc as required:- |
| 117 | Supplying & installation of 400 mm sweep AC padestal fan with metal blade including connection etc as required:- |
| 118 | Supplying & installation of 400 mm sweep AC wall mounting fan with metal blade including connection etc as required:- |
| 119 | Supplying & installation of 400 mm sweep AC wall mounting fan with plastic blade including connection etc as required:- |
| 120 | Supplying & installation of 450 mm sweep wall mounting air circulator including connection etc as required:- |
| 121 | Supplying & installation of 450 mm sweep AC padestal air circulator including connection etc as required:- |
| 122 | Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:- |
| 123 | Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required:- |
| 124 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:- |
| 125 | Dismantling the existing ceiling fan and making winding by (34/35/36 S.W.G) Copper wire, varnish, oiling, greasing and re-fixing the same including wiring the down rod of standard length ( up to 30 cm ) etc. as required :- |
| 126 | Supplying and fixing of 20 mm dia extra down rod (GI Pipe Medium Guage) with necessary hole for installation of ceiling fan as required. |
| 127 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required: |
| 128 | Supplying and fixing of following room heater complete with 15 amps top including necessary connection etc as required. |
| 129 | 1000/1500/2000/2500 watt blower type room heater:- |
| 130 | Supplying and fixing of following vertical storage water heater 5 star catagory complete with 15 amps top, connection pipes including necessary connection etc as required. |
| 131 | 15 litre storage capacity:- |
| 132 | 25 litre storage capacity:- |
| 133 | Supplying and fixing of following accessories for water heater including connection etc as required as per direction of site Engineer. |
| 134 | Heating element / Coil |
| 135 | Thermostat/ Thermal cutout. |
| 136 | Supplying and fixing of following luminaries complete with necessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours):- |
| 137 | Bulk head fittings with frosted/clear glass suitable for GLS or retrofit CFL/LED (without lamp) : - |
| 138 | Decorative wall mounting fancy bracket light fixture suitable for GLS or retrofit CFL/LED (without lamp) : - |
| 139 | Supplying and fixing of the following Lamps & accessories including connection etc. as required. |
| 140 | 15 watt GLS lamp:- |
| 141 | 25/40/60/100 watt GLS lamp:- |
| 142 | 200 watt GLS lamp:- |
| 143 | 250 watt HPSV lamp:- |
| 144 | 500 watt halogen lamp:- |
| 145 | 1000 watt halogen lamp:- |
| 146 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 147 | Surface mounted integrated 10 watt LED batten with polycarbonate diffuser:- |
| 148 | Surface mounted integrated 20 watt LED batten with polycarbonate diffuser:- |
| 149 | Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):- |
| 150 | Surface mounted box type batten suitable for double 18/20 watt integrated LED tube lamp (without lamp):- |
| 151 | Recessed/Surface mounted 1ft x 1ft decorative 16/18 watt LED panel light with integral driver and high quality polycarbonate diffuser:- |
| 152 | Recessed round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 153 | Surface mounted round/Square shaped 6/7 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 154 | Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 155 | Surface mounted round/Square shaped 18/20 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 156 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 157 | 25 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 158 | 45 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 159 | 60 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 160 | 90 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 161 | 120 watt LED flood light fixture with integral driver and secondary lens (IP 66):- |
| 162 | 150 watt LED flood light fixture with integral driver and secondary lens (IP 66):- |
| 163 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:- |
| 164 | 18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):- |
| 165 | 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink |
| 166 | 12 watt LED retrofit lamp with polycarbonate body and aluminium heatsink |
| 167 | 20 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 168 | 40 watt LED retrofit lamp with polycarbonate body and aluminium heatsink |
| 169 | Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:- |
| 170 | 32 amps 415 volts four strip Copper busbar chamber 4 ways of size (300mmx240mmx80mm):- |
| 171 | 63 amps 415 volts four strip Copper busbar chamber 4 ways of size (330mmx280mmx100mm):- |
| 172 | 100 amps 415 volts four strip Copper busbar chamber 4 ways of size (455mmx330mmx120mm):- |
| 173 | 200 amps 415 volts four strip Copper busbar chamber 4 ways of size (455mmx330mmx120mm):- |
| 174 | Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:- |
| 175 | 32 amps 240 volts DP main switch (rewireable):- |
| 176 | 63 amps 240 volts DP main switch (rewireable):- |
| 177 | 32 amps 415 volts TPN main switch (rewireable):- |
| 178 | 63 amps 415 volts TPN main switch (rewireable):- |
| 179 | 100 amps 415 volts TPN main switch (rewireable):- |
| 180 | 200 amps 415 volts TPN main switch (rewireable):- |
| 181 | Supplying and installation of fuse unit kitkat/HRC/HBC of the following ratings in existing main switch/panel board including necessary connection etc as required:- |
| 182 | 32 amps kitkat porcelain fuse unit with base(rewireable):- |
| 183 | 63 amps kitkat porcelain fuse unit with base(rewireable):- |
| 184 | 100 amps kitkat porcelain fuse unit with base(rewireable):- |
| 185 | 200/250 amps kitkat porcelain fuse unit with base(rewireable):- |
| 186 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. |
| 187 | 2 way SPN MCB DB (single door):- |
| 188 | 4 way SPN MCB DB (single door):- |
| 189 | (2+4) / 6 way SPN MCB DB (single door):- |
| 190 | (2+6) / 8 way SPN MCB DB (single door):- |
| 191 | (2+10) / 12 way SPN MCB DB (single door):- |
| 192 | 4 way horizontal TPN MCB DB (Single door):- |
| 193 | 4 way horizontal TPN MCB DB (Double door):- |
| 194 | 6 way horizontal TPN MCB DB (Double door):- |
| 195 | 8 way horizontal TPN MCB DB (Double door):- |
| 196 | Supplying and installation of powder coated steel sheet enclosure for 415 volts MCCB (TP/FP) complete with necessary connection etc as required |
| 197 | Enclosure suitable for MCCB upto 100 amps:- |
| 198 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:- |
| 199 | 6 to 32 amps SP MCB:- |
| 200 | 6 to 32 amps DP MCB:- |
| 201 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:- |
| 202 | 40 amps DP isolator:- |
| 203 | 63 amps DP isolator:- |
| 204 | 63 amps FP isolator:- |
| 205 | Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):- |
| 206 | 16 to 100 amps TP MCCB, Breaking capacity 16/18KA (Thermal Magnetic):- |
| 207 | 16 to 100 amps FP MCCB, Breaking capacity 16/18KA (Thermal Magnetic):- |
| 208 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required |
| 209 | 3 core 4 Sq mm |
| 210 | 4 core 10 Sq mm |
| 211 | Supplying and fixing of aluminium terminal ends (LUGS) - long barrel of following sizes : - |
| 212 | 4/6 sq mm |
| 213 | 10 sq mm |
| 214 | Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes: - |
| 215 | 4 sq mm |
| 216 | 10 sq mm |
| 217 | 6 sq mm |
| 218 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:- |
| 219 | 25 mm dia |
| 220 | 40 mm dia |
| 221 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:- |
| 222 | Supplying and fixing of 20 mm MS pipe as down rod for installation of luminaries with necessary accessories etc as required. |
| 223 | Supplying & fixing of 40 mm dia G.I pipe (medium gauge) cross bar for fixing of ceiling fan/luminaries including painting & necessary accessories etc as required. |
| 224 | Supplying & fixing of 40mmx6mm MS clamp for installation of ceiling fan/luminaries on cross bar including necessary accessories etc as required:- |
| 225 | Supplying & fixing of 12mm thick marine plywood conforming to IS:710 with necessary painting etc as required:- |
| 226 | Excavation of earth for cable trench of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks per metre for protection including ramming, consolidating to the original shape as per dirrection of Site Engineer :- |
| 227 | Drawing of armoured/un-armoured cable with proper saddling etc as required:- |
| 228 | Cleaning of existing ceiling fan/luminaries. |
| 229 | Supplying, installation, testing and commissioning of following ratings inverter with Square/ sine wave technology, noiseless operation, inbuilt advance PCB programming, microprocessorwith all accessories including necessary connections etc. as required:- |
| 230 | 600VA, 12V DC, 1 Ph input/1 Ph output inverter(Square wave technology):- |
| 231 | 850VA, 12V DC, 1 Ph input/1 Ph output inverter(Square wave technology):- |
| 232 | 1100VA, 12V DC, 1 Ph input/1 Ph output inverter(Square wave technology):- |
| 233 | Supplying, installation, testing and commissioning of following ratings Valve regulated lead acid(VRLA) battery with all accessories including necessary connections etc. as required:- |
| 234 | 12 V/ 150AH tall tubular/ flat plate Battery:- |
| 235 | 12 V/ 180AH tall tubular/ flat plate Battery:- |
| 236 | 12 V/ 200AH tall tubular/ flat plate Battery:- |
| 237 | Hiring of 01(one) electrician/ skilled wireman for providing of duty in 01(one) shift for upkeeping & mtc.of the existing electrical installations i.e light fixtures, fan, outdoor lights, main electrical pannel, distribution pannel i/c restoration / replacement of defective components along with addition/ alteration IE installations etc.as per the the direction of the Engineer-In-Charge. Please Enable Macros to View BoQ information |