| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) with modular switch modular plates suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.;(a) Group A -- with Cat A Modular Accessories |
| 2 | Wiring for 5A /15A power plug with 2 x 4 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) alongwith 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required.;(a) 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earthwire (20mm Conduit) |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required.;(b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit) |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required.;(c) 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm Conduit) |
| 6 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required;(a) Cat A |
| 7 | Supplying and fixing following size modular PVC box alongwith modular base and cover plate for modulator switches in recess etc. as required;(a) 1 or 2 Module Cat A |
| 8 | Supplying and fixing following size modular PVC box alongwith modular base and cover plate for modulator switches in recess etc. as required;(g) 18 Module ) Cat A |
| 9 | Supplying and fixing suitable size modular PVC box with modular plate and cover in front on surface or in recess including providing and fixing 1 no 6 pin 15/16 A modular socket outlet and 1 nos 15/ 16 A modular switch connection painting etc. as required. ( For workstations);(a) Cat A |
| 10 | Supplying and fixing suitable size modular PVC box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch connection painting etc. as required. |
| 11 | Supplying and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch on board the modular surface/recessed PVC/GI modular box by suitably increasing its modular capacity modular plate and cover including connection painting etc. as required.;(a) Cat A |
| 12 | Installation earthing testing and commissioning of pre-wired fluorescent fitting/ compact fluorescent fittings of all types complete with all accessories and tube etc. directly on ceiling / wall including connections with 1.5 sq .mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required. |
| 13 | Installationearthing testing and commissioning of ceiling fan including wiring the down rod of standard length ( upto 30 cm) with 1.5 sq .mm FRFRLS PVC insulated copper conductor single core cable etc. as required. |
| 14 | Carriage of ceiling fan and regulator/ exhaust fan from store to site as required. |
| 15 | Extra for cutting and threading of GI pipe heavy gauge down rod for ceiling fan etc as required |
| 16 | Supplying and fixing extra down rod of 20 cm length GI pipe 15 cm dia heavy gauge including painting etc as required |
| 17 | Installation earthing testing and commissioning of exhaust fan upto 450 mm sweep in the existing opening including making the hole to suit the size of the above fan making good the damage connections testing commissioning etc as required |
| 18 | Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required (but without MCB/RCCB/Isolator);(f) 8 way double door Cat A |
| 19 | Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required (but without MCB/RCCB/Isolator);(g) 12 way double door Cat A |
| 20 | Supplying and fixing 6 A to 32 A C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.;(a) SP Cat A |
| 21 | Supplying and fixing 6 A to 32 A C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.;(b) SPN Cat A |
| 22 | Supplying and fixing following rating double pole 240 V isolator in the existing MCB DB complete with connections testing and commissioning etc as required;(a) 40 A Cat A |
| 23 | Supplying and fixing following rating three pole 415 V isolator in the existing MCB DB complete with connections testing and commissioning etc as required;(a) 40 A Cat A |
| 24 | Supplying and fixing SP blanking plate in the existing MCB DB complete as required |
| 25 | Supplying and drawing/fixing indoor type 0.5 sq.mm FR PVC insulated copper conductor unarmoured telephone cable ITD/DOT approved with GI saddles on wal or in the existing surface/recesed steel/PVC conduit having folowing pair(s) complete as required.;(a) 2 Pair |
| 26 | Supplying and fixing of following sizes of PVC casing caping alongwith accessories on surface as required.;(b)25mm casing capping |
| 27 | Supplying and drawing/fixing indoor type 0.5 sq.mm FR PVC insulated copper conductor unarmoured telephone cable ITD/DOT approved with GI saddles on wal or in the existing surface/recesed steel/PVC conduit having folowing pair(s) complete as required.;(a) 2 Pair |
| 28 | Supplying and drawing of Cat - 6 UTP 4 pair annealed tinned copper conductor PVC insulated PVC sheathed unarmoured data cable in existing surface/recessed steel/PVC conduit of appropriate size including connection etc. complete as required;(a) Cat 6 |
| 29 | Supplying installation and testing of suitable size modular GI box modular plate and cover complete with RJ-45 connector(modular LAN socket TX1000/ CAT6) including concealed metal box/surface GI/PVC Box modular plate punching identifying complete as required.;CAT A |
| 30 | Supplying installation and testing of suitable size modular GI box modular plate and cover complete with RJ-11 connector(modular telephone socket) including concealed metal box/surface GI/PVC Box modular plate punching identifying complete as required.;CAT A |
| 31 | Supply of 4 core armoured PVC/XLPE insulated PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) IS:7098(Part I) with latest amendments of following size.;4 Core 10 sq.mm |
| 32 | Supply of 4 core unarmoured PVC/XLPE insulated PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) IS:7098(Part I) with latest amendments of following size.;4 Core 6 sq.mm |
| 33 | Supply of 3 core armoured PVC/XLPE insulated PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) IS:7098(Part I) with latest amendments of following size.;3 Core 4 sq.mm |
| 34 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm in the existing masonry open duct etc. complete as required |
| 35 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Inchargesand cushioning with screened sand bed of 20mm thick protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.;(b) In rocky strata |
| 36 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface etc. complete as required |
| 37 | Supply and erecting of 48 inch (1200mm sweep) ceiling fan double ball bearing type complete with all accessories.;(a) Cat A |
| 38 | Supply and erecting of 12 inch (300 mm sweep) exhaust fan with double ball bearings 1400 rpm complete with all accessories.;(a) Cat A |
| 39 | Supply, installation, testing and commissioning of 36 watts or more LED Street light in Pressure die cast aluminium housing with polycarbonate cover having IP 65 class of protection or above having efficient hight output LED of make Greatwhite bearing cat No.LED-STL-38005, or Jaguar fittings bearing cat NoLSRT01S036XC or Bajaj bearing cat No. BRTFG 36W LED or any approved equivalent make ( to be approved by Engineer in Charge) complete with 40 mm dia GI pipe bend at an appropriate angle of length 80cms and having three years free replacement warranty complete as required. |
| 40 | Supply and installation of Post top lantern complete as required approved by engineer In charge |
| 41 | Fabrication of Special Bracket for mounting Ceiling Fan |
| 42 | Supply of LED Round recessed fitting 20 W of required size as per site condition of make Philips, Crompton or equivalent as approved by engineer in charge |
| 43 | Supply of 4 feet 20 W single box/batten industrial type LED luminaire with CRCA body pre coated in white and pre wired for LED type complet with all accessories of make Crompton , model no IGP 131LT8-16 or Havells bearing Cat No. LHFYBYPNIA1W022/ Bajaj Bearing Cat No.BLRB-DB 118/Wipro bearing Cat No WIO 921208 or any approved brand including 1 No of of 4 feet 20 W LED tube of make crompton bearing Cat No. LTT8-20/Bajaj bearing Cat No.BLRB 18W CWc /Havells bearing Cat No.LHLDCLXUL8X020 or Wipro bearing Cat No. LL13-181-650 as required.( Equivalent to be approved by Engineer in charge). The LED tube should have a warranty of two years from the date of commissioning. Please Enable Macros to View BoQ information |