| 1 | Civil and Electrical works (SMA Network -9 Stations )SMA :-Strong Motion Accelerometer MEMS based Data Acquisition system with built in Sensor and GPS. (MR) |
| 2 | (SMA Network -9 Stations )SMA :-Software for Real Time data sending to CRS and processing the data (MR) |
| 3 | (SMA Network -9 Stations )Protective Cover: Protective cover for all SMAConvetor RJ45 to OFS cable (MR) |
| 4 | (SMA Network -9 Stations )LIU:-Ethernet to OFC Convertor with accessories (MR) |
| 5 | (SMA Network -9 Stations )OFC Cable:-Optical Fiber cable from 9 Stations to the control room including installation in Conduit Pipe (MR) |
| 6 | (SMA Network -9 Stations )PC Notebook:- Notebook with latest Specifications for downloading the data and checking of Health and Status of setting up remote station parameters. (MR) |
| 7 | Central Recording Stations (CRS) – For SMA and Broad Band SeismometerPC Workstation (CRS) :- Workstation with latest specification for Real Time monitoring the data display with pre-preloaded with analysis software. ( Branded make like HP/ Lenovo ) (MR) |
| 8 | Central Recording Stations (CRS) – For SMA and Broad Band Seismometer ( HP make ) Laser Jet Printer three in one color laser jet Printer (MR) |
| 9 | Central Recording Stations (CRS) – For SMA and Broad Band SeismometerOnline UPS of 5 KVA with 1 hour back up. (MR) |
| 10 | Central Recording Stations (CRS) – For SMA and Broad Band SeismometerGPS Time Receiver system with 20m cable. (MR) |
| 11 | Installation, commissioning and making network fully operational including transmission of digital data from 9 stations to CRS(MR) |
| 12 | Onsite training for installation, commissioning and operation of the network for one-week period of 4 persons (MR) |
| 13 | Broad Band Seismometer with Data Acquisition System:-Broad Band Seismometer (Triaxial) Velocity sensor with 10 m cable Model MBB. (MR) |
| 14 | Broad Band Seismometer with Data Acquisition System:-Data Acquisition System (DAS) (3 Channels) with inbuilt digitizer and GPS time receiver system with Antenna and 20 m cable. GPS Antenna 3 volt with 5-meter cable ( Model pebble).(MR) |
| 15 | Broad Band Seismometer with Data Acquisition System:-Modem for communication of data from field station to Central recording Station (SIM card to be in scope of BBMB) (MR) |
| 16 | Broad Band Seismometer with Data Acquisition System:-Maintenance free (MF) rechargeable battery for modem (12V/ 150 AH) (MR) |
| 17 | Broad Band Seismometer with Data Acquisition System:-Earthing and lighting arrestor – Maintenance free lighting arrestor for equipment at field station (MR) |
| 18 | Broad Band Seismometer with Data Acquisition System:-Protective cover for Data Acquisition System (MR) |
| 19 | Solar panel :- 75 Watt / 12 Volt DC Solar Panel with Charge Controller and Battery 12 Volt/150 AH. (Back up for 24 Hours, Maintenance Free) (MR) |
| 20 | Installation and Commissioning Charges for Broad Band Seismograph (MR) |
| 21 | First Year AMC charges |
| 22 | Second Year AMC charges |
| 23 | Third year AMC charges |
| 24 | Freight and insurance charges |
| 25 | Earth work in excavation in foundations trenches etc. in all kinds of soil where pick jumper work is not invalid and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15cm layers with compaction including disposal if all surplus soil as directed within lead of 30 metres. [ As per CSR-2020 item No. 6.6 ( b ) ] |
| 26 | Cement concrete 1:6:12 with stone aggregate 40 mm gauge mixing by mechanical means using concrete mixers volumetric type. [ As per CSR-2020 item No. 10.8 ( b ) ii ] |
| 27 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. [ As per CSR-2020 item No. 11.3 ] (i) |
| 28 | Damp proof course 4 cm thick of cement concrete 1:2:4 with two coats of bitumen 20/30 penetration @ 1.65 kg per sqm laid hot and sanded. [ As per CSR-2020 item No. 10.26 ] |
| 29 | First class burnt brick work laid in cement sand mortar 1:6 in first story up to 4 meters above plinth level. [As per CSR-2020 item No. 11.4 ] (i) |
| 30 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrated but excluding steel reinforcement centering and shuttering in superstructure.[ As per CSR-2020 item No. 10.20 ] |
| 31 | Centering and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels [ As per CSR-2020 item No. 9.6 ] |
| 32 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. [ As per CSR-2020 item No. 9.8 ] |
| 33 | Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete[ As per CSR-2020 item No. 18.18 ] |
| 34 | 12.5 mm thick cement plaster 1:6 [ As per CSR-2020 item No. 15.11 ] |
| 35 | 20mm thick cement plaster 1:6 in two coat work [ As per CSR-2020 item No. 15.28 ] |
| 36 | 10 mm thick cement plaster 1:4. [ As per CSR-2010 item No. 15.6 ] |
| 37 | White washing ( Two or more coat) [ As per CSR-2010 item No. 16.2 ] |
| 38 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregates 40mm gauge and 100mm fine sand filling using mechanical mixer for mixing of material. [ As per CSR-2020 item No. 14.3 ] |
| 39 | Conglomerate floor50mm thick cement concrete topping1:2:4 using mechanical mixer for mixing of material [As per CSR-2020 item No. 14.7 ] |
| 40 | Floating coat of 1:5mm thick neat cement laid in one operation to the topping [As per CSR-2020 item No. 14.4 ] |
| 41 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25mm mud plaster 7.5cm mud filling on another layerof 25mm mud plaster including two coats of bitumen laid hot at1.65Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing [As per CSR-2020 item No. 13.13 i ] |
| 42 | Cement concrete 1:2:4 gola 10cm x10cm concave quadrant along junction of roofs with parapet wall finished amooth where specially specified. ( As per CSR- 2020 item no 13.55) |
| 43 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 [As per CSR-2020 item No. 13.45 ] |
| 44 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes single socketed (working pressure 4 kgf/cm2) conforming to IS : 4985, including fixing with MS clamps U-PVCpipes (working pressure 4kgf. / sqcm) pipe 110 mm dia. [As per CSR-2020 item No. 13.74 a (i) ] |
| 45 | Providing and fixing110 mm dia U.P.V.C bend for Rainwater pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. a UPVC 110 mm bend [As per CSR-2020 item No. 13.75 a ] |
| 46 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading forglazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) :For fixed portion and chowkhats. [As per CSR-2020 item No. 17.45 ( a) ] |
| 47 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required. [ As per CSR-2020 item No. 17.45 ( b ) ] |
| 48 | Providing and fixing Stainless steel Jali to the satisfaction of the Engineering in-charge (MR) |
| 49 | Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) For shutter area up to 0.50 sqm [ As per CSR-2020 item No. 17.23-i ] |
| 50 | For shutter area above 0.50 sqm [ As per CSR-2020 item No. 17.23-ii ] |
| 51 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides. [ As per CSR-2020item No. 17.46-ii ] |
| 52 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete ISI designation no I (Size of door up to 700mm) (As per CSR item No. 17.43 (a) |
| 53 | RECESSED HDPE PIPE WIRING SYSTEMWITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked), overall1.5sq. mm, 1100volts grade to be laid in HDPE electrical conduit pipe 20mm/25mmdia. ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3universal socket (shuttered), 16/20Amp.combined/ universal Socket (shuttered),6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½\\" deep for walls and 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm,1100volts grade (For 6Amp. wall socket &plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface): Wiring light point. As per CSR2020 Item No. 34.03 (ii) |
| 54 | Wiring 6Amp. Plug control comprising wall socket point.(As per CSR2020 Item No. 34.03 (v) |
| 55 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- (As per CSR 34.09) Overall size 2.5sq.mm (Un-sheathed) (As per CSR 34.09 iii) Please Enable Macros to View BoQ information |