| 1 | External Electrification Works of Railway Staff Quarters and Other Service Buildings at Holenarsipura and Mysuru, in connection with Railway Electrification works of Mysuru-Hassan-Mangalore section of South Western Railway. |
| 2 | Amount after unconditional rebate |
| 3 | Total Of BOQ 3, BOQ 4 and BOQ 5 |
| 4 | SCHEDULE -\\"A\\" DSR 2025 Electrical Items |
| 5 | SCHEDULE -\\"B\\" KPWD SR 2023-24 - Electrical Items |
| 6 | SCHEDULE - \\"C\\" Market Rate - Electrical Items |
| 7 | Part A - DSR 2025 - Electrical Items |
| 8 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 9 | Above 120 sq. mm and upto 400 sq. mm |
| 10 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 11 | Above 120 sq. mm and upto 400 sq. mm |
| 12 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 13 | Upto 35 sq. mm |
| 14 | Above 35 sq. mm and upto 95 sq. mm |
| 15 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 16 | Upto 35 sq. mm |
| 17 | Above 35 sq. mm and upto 95 sq. mm |
| 18 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 19 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 20 | 4 X 16 sq. mm (28mm) |
| 21 | 3½ X 50 sq. mm (35mm) |
| 22 | 3½ X 95 sq. mm (45mm) |
| 23 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 24 | 4 X 16 sq. mm |
| 25 | 3½ X 50 sq. mm |
| 26 | 3½ X 95 sq. mm |
| 27 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc a required |
| 28 | 100 mm dia |
| 29 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 30 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 31 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 32 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 33 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 34 | Part B - KPWD SR 2023-24 -Electrical Items |
| 35 | LED Street Light - 'Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT > 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency>1301m/w, nominal CRI >75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. |
| 36 | LED Streetlight 70W |
| 37 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. |
| 38 | Supplying and Fixing of........mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GIor GIorrailor RCC pole/wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. |
| 39 | Using 32mm dia G.I.Pipe |
| 40 | GI/ Copper strips for grounding connections, using necessary fixing materials as required. |
| 41 | 50 x 6 mm GI strip |
| 42 | 50 x 6 mm Copper strip |
| 43 | Supplying & Fixing Chemical earthing for grounding. Conduits, IC cut -outs & other equipments back fill compound which is non -corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm |
| 44 | Using 4ft. Copper bonded rod with backfill compound |
| 45 | Providing 6kg Fire Extinguisher Mono Ammonium Phosphate Powder 90, Stored Pressure Type, Pressure Gauge, Gross Weight 9.40 Kg, empty weight 3.4 Kg, Can Height 480MM, Diameter 160MM, Discharge Time less than 13 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,B, C and electrically started Fire, A Rating 3A, B Rating 21B, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete IS 15683 and CE Approved |
| 46 | Providing 4.5Kg C02 gas valve type Fire Extinugisher, Tro lley Mounted, Easy Weight Management used Unused Mechanism, Gross Weight 19.1 Kg. empty Weight 14.6 Kg. Can Height 860MM Diameter 140MM, Discharge Time less than13 Sees,Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 138, Can Constuction : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness : 4.5M M lSI Approved, 1YearWarranty.with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete |
| 47 | Supplying of four bucket stand along with buckets, complete. |
| 48 | Supplying of Hand gloves, complete. |
| 49 | Supplying of first aid box, complete. |
| 50 | Supplying of Saftey Mask, complete. |
| 51 | Supplying of First Aid Chart with lamination, complete. |
| 52 | Supplying and installation of Rubber Mat 1 mtr x 1 mtr - 10 mm thick, complete including cost of materials, labour, usage charges of machinery complete as per specifications. |
| 53 | RCC Pole - 9 Mtr Long, 150 Kg WL Sq Section (Dwg No. BESCOM/GM/QS&S/51 Dtd 24.11.2018) as per IS-785- 9mtr 150Kg WL |
| 54 | Supply |
| 55 | Erection - (Including Erection, Excavation & Fixing) |
| 56 | Pre-Stressed Tubular Spun Pole - 11 Mtr Long, 500 Kg WL(Dwg No. BESCOM/GM/QS&S/45 Dtd 24.11.2018) as per IS-13158: 1991 |
| 57 | Supply |
| 58 | Erection of 11 Mtr long Concrete Spun Pole in a pit of 2.5 Mtr depth (Mechnised Labour) |
| 59 | Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved Drawing |
| 60 | Hard Soil |
| 61 | 11 kV, Horizontal Cross Arm - Galvanised Iron (GI) |
| 62 | Supply |
| 63 | Erection |
| 64 | 11 kV, 200 Amps Single Break Polymer Type Post Insulators GOS |
| 65 | Supply |
| 66 | Erection |
| 67 | H - Frame Set for fixing 11 kV, 200 Amps Single Break GOS - (For DP structure for providing New GOS for sectionalisation) - GI |
| 68 | Supply |
| 69 | Erection |
| 70 | 11 kV, DOLO Cutout Conventional to Erstwhile KEB Specification |
| 71 | Supply |
| 72 | Erection |
| 73 | Single H Frame without Transformer Seating and Seating angle support cross arm for 11 Mtr Spun Pole for 63/100/250/500 kVA (OH Line) - MS |
| 74 | Supply |
| 75 | Erection |
| 76 | LT Line Spacer-For 4 Wire |
| 77 | Supply |
| 78 | Erection |
| 79 | 11 kV, 5 KN Composite/Polymeric Pin Insulator (24 mm Dia FRP Rod)-Supply & Erection |
| 80 | 1.1 kV Polymeric Pin Insulator-Supply & Erection |
| 81 | No. 8 Strain Insulator-Supply & Erection |
| 82 | No. 15 Strain Insulator-Supply & Erection |
| 83 | Guy Wire & GI Wire as per IS-2141-7/10 SWG Guy Wire(7/3.251 mm Dia), Std Wt: 680 Kg/KM |
| 84 | 11 kV, Special 3 Pin Cross Arm - GI |
| 85 | Supply |
| 86 | Erection |
| 87 | LT 4 Pin Cross Arm - GI |
| 88 | Supply |
| 89 | Erection |
| 90 | LT 2 Pin Cross Arms - GI |
| 91 | Supply |
| 92 | Erection |
| 93 | LT ST Support 50x6 mm Flat - GI |
| 94 | Supply |
| 95 | Erection |
| 96 | HT ST Support 50x8 mm Flat - GI |
| 97 | Supply |
| 98 | Erection |
| 99 | Spiral Earth Electrode |
| 100 | Supply |
| 101 | Erection |
| 102 | Clamps A Type (MS & GI) as per IS-1977-RCC Pole Clamp - GI |
| 103 | Supply |
| 104 | Guy Clamp - MS (Dwg No. BESCOM/GM/QS&S/07 Dtd 24.11.2018) |
| 105 | Supply |
| 106 | Erection |
| 107 | Anchor Rod using 12 mm rounds/Guy Rod - GI |
| 108 | Supply |
| 109 | PG Clamp- Rabbit to Rabbit |
| 110 | Supply |
| 111 | PG Clamp Rabbit to Insulated Wire - 95 Sqmm(Dwg No. BESCOM/GM/QS&S/43 Dtd 24.11.2018 |
| 112 | Supply & Erection |
| 113 | LT Distribution Box as per IS-13947 Part-1&2 - LT Distribution Box for 100/250 kVA DTC with MCCB's (SMC) |
| 114 | Supply |
| 115 | Erection |
| 116 | 10 kV, 5 kA Lightning Arrester Polymeric type with GROUND DISCONNECTOR |
| 117 | Supply |
| 118 | Erection |
| 119 | Double Pole TC Set for erection of Transformer on RCC/PSCC 9 Mtr Long Poles as per IS-1977 - For 100/300 kVA 4/5 Star Rated Transformer onRCC Pole - 9 Mtr Long, 145 Kg WL - GI |
| 120 | Supply |
| 121 | Erection |
| 122 | 1.1 KV Class HR (Heat Resistant) PVC Insulated & UnSheathed Aluminium Wires Multistrand Single Core Lead wires as per IS-694: 2010 - PVC Wire - 185 SqmmAl Wt: 49 Kg, Total Wt: 68 Kg/100 Mtr Coil |
| 123 | Supply |
| 124 | Erection |
| 125 | Meter Protection/Tamper Proof Box (MS) for LT Installations 25 HP and above-LT Metering Box for housing the ETV Meter without CT's busbar wiring etc |
| 126 | Supply |
| 127 | Erection |
| 128 | CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port UNIDIRACTIONAL (Used for HT Installation, LT Metering Cubicle {50-150 KW}) |
| 129 | Supply |
| 130 | Erection |
| 131 | 3 Phase CT/PT operated alternating current Smart Meter of Accuracy Class 0.2s DLMS with RF Communication Module |
| 132 | Supply |
| 133 | Erection |
| 134 | LT AC 3 Phase 4 Wire CT Operated, 5 Amps Smart Energy Meter, Class 0.5s Accuracy with RF Communication Module |
| 135 | Supply |
| 136 | Fixing and Wiring of Single/3 Phase Meter on the existing meter board |
| 137 | Miscellaneous Materials |
| 138 | Caution/Danger Board |
| 139 | Fixing of Danger Board |
| 140 | Full Threaded Bolt & Nut as per IS-1367-16x65mm |
| 141 | ACSR conductor as per IS : 398 (Part - 2/1996) are the latest revision - Rabbit ACSR (6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM |
| 142 | Stringing of Conductor (including pin binding, providing jumps, dead ending, etc.,) - Rabbit |
| 143 | Releasing of Conductor - Rabbit |
| 144 | 11 kV [6.35/11 kV(E)], HT Aerial Bunched Cable XLPE insulation confirming to IS-14255: 1995 - 3x95 + 1x70 Sqmm (Insulated Messenger Wire) |
| 145 | Supply |
| 146 | Stringing of 11 kV grade Aerial Bunched 3 Core cable of XLPE insulation of size 3x95 Sqmm + 1x70 Sqmm with Insulated Messenger Wire |
| 147 | 11 kV [6.35/11 kV(E)], HT Aerial Bunched Cable XLPE insulation confirming to IS-14255: 1995 - 3x95 + 1x70 Sqmm (Insulated Messenger Wire) |
| 148 | Supply |
| 149 | Stringing of 1.1 kV grade Aerial Bunched 3 Core cable of XLPE insulation of size (3x95) (Phase Conductor) + (1x70) (Insulated Messenger Neutral) + (1x35) (Street Light Control |
| 150 | Accessories for ABC Cables as per NF-33, as per IS-13573 for Joints & Terminations - Suspension Clamp suitable for insulated Messsenger wire of size 25 to 95 Sqmm |
| 151 | 11 kV, AB Cable Straight thru' joint kit suitable for 95 Sqmm - Supply |
| 152 | Universal Hook and Bolt & Nut |
| 153 | Supply |
| 154 | Erection |
| 155 | Dead End Clamp/Anchor Clamp Assembly 70 to 210 Sqmm Bare Messenger (Exclusive of Pole Clamp and Eye Hook) |
| 156 | Supply |
| 157 | Erection |
| 158 | a) Loading and unloading of Pole (loading of Pole to vehicles at stores and unloading at workspot) NOTE:- Consolidated amount for both loading and unloading. |
| 159 | 9 Mtr RCC/PSCC Pole |
| 160 | ESCOM SR Items 2021 - 22 Electrical |
| 161 | A)Base Concreting with CC 1:4: 8 |
| 162 | a).Pole base for 11/9.5/9/8 Mtr supports (500x650x150mm) |
| 163 | b).Pole base for 11 Mtr Spun Pole (1000x1000x150mm) |
| 164 | B) Pole Concreting with CC 1:2:4 (without coping) |
| 165 | a).9 Mtr support (650x500x1700mm) |
| 166 | e) 11 Mtr Spun Pole (1000x1000x2500mm) |
| 167 | g) Guy concreting with Boulders, Mud & Sand As per Drawing No. BESCOM/GM/CP/7/dt: 24.10.07. (with out cement) |
| 168 | C) Providing Coping for Pole with CC 1:2:4 (As per actuals) |
| 169 | a) 150 mm all around the Pole for an height of 300 mm for RCC, PSCC Pole |
| 170 | Part - C -MARKET RATE - Electrical Items |
| 171 | Street Light Feeder Pillar Panel: |
| 172 | Supply, erection, testing and commisioning of Outdoor type Street Light Feeder Pillar Panel fabricated out of 14 SWG CRCA sheet steel metal with all aluminium TPN busbars, doors interlock with switches, dead front type design, metal pretreatment of such as derusting, degreasing, phosphating, Powder coated, prime coats and finish paints of approved color with all leads and lift and as directed by the Engineer incharge. The Panel shall be erected with suitable\\" C \\" Channels over the existing Duct and shall comprise of the following. |
| 173 | Incoming |
| 174 | 32 Amps, MCB's TP + NL, - 1No |
| 175 | RYB phase indication lamps - 1 set |
| 176 | (MDM) Data Main Meter - 1No |
| 177 | CT Ratio 100 / 5 A, Class 1.0 - 3 no's |
| 178 | ON / OFF ILPB with NO- NC Contactors - 2 Sets |
| 179 | Auto / Manual Selector Switch - 1 Nos |
| 180 | Out-going |
| 181 | 32/40 Amps MCB's FP, 10 ka Breaking Capacity - 4 No's |
| 182 | Transformer 15 KV Transformer in Control type - 1No |
| 183 | Supply, installation, testing and commissioning outdoor type 3 Phase Meter Box (Temper Proof Box with CT) |
| 184 | Incoming |
| 185 | Aluminiaum Bus Bar 200 Amps , TP + NL & Bus Bar Connecting |
| 186 | CT Ratio 000/ 5 A, Class 0.5 va - 4 no's |
| 187 | Out-going |
| 188 | Aluminiaum Bus Bar 200 Amps , TP + NL & Bus Bar Connecting |
| 189 | Supply, installation, testing and commissioning outdoor type 3 Phase Meter Box (Temper Proof Box without CT) |
| 190 | Incoming |
| 191 | Aluminiaum Bus Bar 200 Amps , TP + NL & Bus Bar Connecting |
| 192 | Out-going |
| 193 | Aluminiaum Bus Bar 200 Amps , TP + NL & Bus Bar Connecting |
| 194 | Supply, erection, testing and commisioning of Outdoor type LT Metering Panel fabricated out of 16 SWG CRCA sheet steel metal with all aluminium TPN busbars, doors interlock with switches, dead front type design, metal pretreatment of such as derusting, degreasing, phosphating, Powder coated, prime coats and finish paints of approved color with all leads and lift and as directed by the Engineer incharge. The Panel shall be erected with suitable\\" C \\" Channels over the existing Duct and shall comprise of the following. |
| 195 | Incoming |
| 196 | 100 A TP +NL MCCB 36 KA breaking capacity with O/C, S/C release - 1 No, |
| 197 | 150 A Aluminium Busbar - 1 set (Colour code shall be followed strictly for all phases) with heat shrinkable sleeves and SMC busbar supports) |
| 198 | RYB phase indication lamps - 1 set |
| 199 | Volt meter with selector switch - 1 No |
| 200 | Ammeter with selector switch - 1 No |
| 201 | Earth Leakage Relay with CBCT - 1 No |
| 202 | 6 Amps SP MCB for Control Circuits |
| 203 | CTS 100/5A Class 1.0 Burden 5VA. |
| 204 | Out-going |
| 205 | Individual Single phase metering compartment with look through glass arrangment- 5 No's |
| 206 | Individual Three phase metering compartment with look through glass arrangment - 2 No's |
| 207 | Each Compartment with complete wiring for single phase meter / Three phase meter |
| 208 | Each Compartment with 32 A Fuse cutout |
| 209 | One full MCB Compartment with 5 nos of 32 Amps DP MCB's and 2 nos of 40 A TPN MCB's |
| 210 | Suitable Spreader Terminals and Extended Rotary Handles for all MCCB's as required. |
| 211 | Supply of 1.1 KV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LT UG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 |
| 212 | Supply |
| 213 | 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm) |
| 214 | 50 Sqmm, 3.5 Core, (18 GI Strips - 4 x 0.8 mm) |
| 215 | 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) |
| 216 | HT UG Cable |
| 217 | Arranging HT Power supply |
| 218 | Arranging required HT Power supply from MESCOM wth Submission of application for Power supply, Obtaining Power sanction, CEIG / CEA Approval from Electrical Inspectorate , Feasibility report, Preparing wiring Diagram, Completion report, Agreement papers as per the requirement of MESCOM, Liasioning and Final Servicing of the Installation with Permanent power supply ( Excluding Deposits & other Charges to be remitted to MESCOM.) Please Enable Macros to View BoQ information |