| 1 | S&F HDPE DWC (Double wall corrugated) pipes confirming to IS-16098 of 152mm & 180mm internal & external dia respectively, pressure rating SN-8 fixed with rubber seal and copler required with and incl. suitable bends 90/60/45 degree etc, single Y junction, complete as required fixed as per manufacturer instruction laid in trenches for sewage lines all as specified and as directed.Note:- Rated included for pipes, bends any size and any types, Y junction copler/adaptor etc required and net total length of pipe with fitting shall be measured for payment purpose. Rate quoted by the contractor shall also include (a) (a) Removal of broken pipes, concrete bed and any other material upto 50m (b) Making surface under sewage pipe to required gradient for smooth flow of sewage (c) Filling and proper ramming of earth under, around and above the pipe after pipe is laid and tested and providing smooth/ levelled finish as already existing. |
| 2 | Cutting in to existing manholes any dia for connecting new drains,making good to pipe and rendering,cutting out existing benching for and forming branch channel(1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished,and reforming benching as required. |
| 3 | M&L to attend and rectify sewage complaint on daily routine basis as per complaint lodged by user at complaint cell through offline complain/online complain/verbal communications/telephonic communicatio of AGE B/R Sub division by deploying manpower by Cleaning/clearing blockage of bathroom/kitchen/WC Indian/WC European by cleaning the Nahani trap/gully trap/floor trap/Intercepting trap/P or S trap/multi floor trap etc of any description and in any position below or above ground level at different loacations ,flushing down with adequate water, removing & taking out of all materials such as sludge/ soil waste/polythene /mud/silt/liquid/semi liquid /semi solid/solid or any others items etc to make the entire system functional complete all as specified and directed.Note: (a) Complaint register/slip shall be produced at the time of claiming the payment.(b) Minimum one person shall be present on all working days 0900 hrs to 1700 hrs to attend the above complaint and reporting the progress to AGE B/R-I sub Divn.(c) Contrctor shall arrange suitable T&P (such as KHAPACHI, Bamboo, cleaning rod and suitable materials/tools, GI wire, PHAWADA, bucket, spike etc incl. necessary form work/scaffolding and safety measures.(d) For non-attending of sewage complaints within 48hrs recovery of Rs 200/- per complaints per day shall be deducted from his dues onthis account and the report on non compliance of such complaints enclosed with each RAR/Final bill.(e) Noting of complaints and distribution of complaints and maintaining record of complaint shall be arranged by contractors at his own expense |
| 4 | M&L for Cleaning and de-silting of manholes depth not exceeding 1.50 meter by pumping out/removing liquid waste/sewage/sludge and plugging the ends sewer pipes or diverting the flow into drains if necessary, removing silt, sludge,solids,semi solids etc, sprinking bleaching powder on the silt to avoid bad smell including all precautionary and safety measures, such as safety belts, lighting arrangements face mask etc and removing the same(silt,sludge &other waste material) in leak proof trucks covered with tarpoline to outside of MOD land all as per existing rules and regulations of civil authorities and flushing sewage line & manholes with adequate water as to make sewage line fully functional including reinstating the manhole cover to its original position complete all as specified and directed by Engr-in-Charge. |
| 5 | All as per Item No 4 above but depth depth exc 1.5 mtr complete all as spd and directed. |
| 6 | M&L Cleaning and desilting of sewage lines of any dia bore at any depth by pumping out /removing liquid waste/sewage ,plugging the ends pipes or diverting the flow into drains if necessary, removing silt, sludge either manually or mechanical means using truck mounted hydraulic jet pressure or as required on ground , including all precautionary and safety measures, such as safety belts, lighting arrangements face mask etc and removing the same(silt,sludge &other waste material) in leak proof trucks covered with tarpoline to outside of MD land all as per existing rules and regulations of civil authorities and flushing sewage line & manholes with adequate water as to make sewage line fully functional including reinstating the manhole cover to its original position complete all as specified and directed by Engr-in-Charge. (Note: Length of sewage lines including chambers, traps etc will be measured for payment. However cleaning of manholes shall be measured separately under appropriate item.) |
| 7 | Cleaning of septic tanks/soakage well/grease trap of any size,capacity & depth by Mechanically using sewage tankers/ Truck mounted hydraulic jet pressure machine with flushing the sewage line with heavy duty sewage pumps sewage suction pump,by desluding,dewatering,taking out of all materials such as sludge/ soil waste/polythene /mud/silt/liquid/semi liquid /semi solid/solid or any unwanted items etc,including flushing with adequate water to make the fully functional,re-fixing opened access cover and removing all retrieved material outside the periphery of defence land.Note :- The measurement for the quantity of sludge removed will be arrived by multiplying the inner dimensions of septic tank to actual depth of sludge deposited by dipping the measuring rod. The depth shall be of that wet surface sludge on measuring rod for payment purpose. |
| 8 | Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 9 | M&L for brick work in cement mortar 1:4 of old size sub class ‘B' bricks straight or curved on plan exceeding 6mtr mean radius complete all as specified and directed. |
| 10 | All as per description of item 9 above but except bricks complete all as specified and directed |
| 11 | M&L for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed. |
| 12 | Demolition of cement concrete unreinforced of any description in any position not otherwise specifically provided for complete all as specified and directed |
| 13 | M&L for PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in coping ,PCC block for hold fast including all necessary from work complete all as specified and directed. |
| 14 | M&L for (a) 15mm thick plaster in cement sand mortar (1:4) mixed with water proofing compound as approved as per manufacturer’s instructions shall be applied both on floor and wall. The surfaces then shall be cured and allowed to dry. All the joints of pipe shall be sealed properly.(b) Apply a coat of Moisture Cured High Tensile Elastomeric Modified Poly Urethane Based Liquid Membrane on floor as well as on wall as per manufacturer’s instructions of make/manufacturers as specified.(c) Manufacturer/approved agencies for water proofing treatment to sunken slab/portion membrane shall be as per approved list (Note:-The Rate included for WPC )Note:- Ponding test to be carried out after application and leakage seepage if any to be rectified by WPC layer before filling PCC 1:5:10. |
| 15 | Providing precast cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in cover slabs,shelves nd similar articles with flat iron frames including necessary moulds/formwork set in cement mortar (1:6) complete all as specifed and directed. NOTE: Flat iron frames wll be measured and paid seperately |
| 16 | M&L for MS angle iron frame for manholes frame and covers including necessary cutting,welding,drilling,bolting etc as required complete all as spd and directed by engr in charge. |
| 17 | M&L for Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 18 | M&L for Mild steel TMT bars 6mm to 8mm dia cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 19 | Demolition by breaking up drain pipes (salt glazed stoneware or AC/RCC/DWC) any dia jointed in cement mortar and taking out of trenches and removing the debris including concrete bed and haunching from the trenches complete all as specified and directed by Engineer-in-Charge |
| 20 | Reinforced concrete pipes,of bore of pipe in 150 mm class NP2, laid & jointed complete with collars laid in trenches in concrete padding jointed in cement mortar 1:1 complete all as specified and directed by Engineer-in-Charge. Note:-Rated included for pipes, bends any size and any types, Y junction copler/adaptor etc required and net total length of pipe with fitting shall be measured for payment purpose. Rate quoted by the contractor shall also include (a) (a) Removal of broken pipes, concrete bed and any other material upto 50m (b) Making surface under sewage pipe to required gradient for smooth flow of sewage (c) Filling and proper ramming of earth under, around and above the pipe after pipe is laid and tested and providing smooth/ levelled finish as already existing. |
| 21 | Reinforced concrete pipes,of bore of pipe in 300 mm class NP2, laid & jointed complete with collars laid in trenches in concrete padding jointed in cement mortar 1:1 complete all as specified and directed by Engineer-in-Charge. Note:-Rated included for pipes, bends any size and any types, Y junction copler/adaptor etc required and net total length of pipe with fitting shall be measured for payment purpose. Rate quoted by the contractor shall also include (a) (a) Removal of broken pipes, concrete bed and any other material upto 50m (b) Making surface under sewage pipe to required gradient for smooth flow of sewage (c) Filling and proper ramming of earth under, around and above the pipe after pipe is laid and tested and providing smooth/ levelled finish as already existing. |
| 22 | Concrete bed to drain pipes of bore 150mm dia including packing under hunching against the sides of pipe after they are laid tested in cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates complete all as specified and directed by Engineer-in-Charge |
| 23 | Concrete bed to drain pipes of bore 300 mm dia including packing under hunching against the sides of pipe after they are laid tested in cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates complete all as specified and directed by Engineer-in-Charge |
| 24 | Taking down cement plaster on brick or concrete surfaces any description including raking out joints hacking for key scrubbing down with water |
| 25 | M&L for Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surfaces including scaffolding upto 7 mtr height and curing the surface complete all as specified and directed by Engineer-in-charge. |
| 26 | Preparation of new plastered surfaces and Material & Labour for applying Two or more coats of weather proof exterior acrylic emulsion paint(1st Quality) of required shade (Company Depot Tinted) with silicon additives, over and including priming coat of exterior primer of same make on surfaces of walls complete all as specified and directed. Note :- (a) Height of Bldg : any height (b) Exterior acrylic emulsion paint shall be anit-fungal, dust resistant, water repellant, crack-bridging, weather proof type 1st Quality. Please Enable Macros to View BoQ information |
| 27 | Preparation of new plastered surfaces and Material & Labour for applying Two or more coats of weather proof exterior acrylic emulsion paint(1st Quality) of required shade (Company Depot Tinted) with silicon additives, over and including priming coat of exterior primer of same make on surfaces of walls complete all as specified and directed. Note :- (a) Height of Bldg : any height (b) Exterior acrylic emulsion paint shall be anit-fungal, dust resistant, water repellant, crack-bridging, weather proof type 1st Quality. Please Enable Macros to View BoQ information |