| 1 | Excavating in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for foundation of poles, laying of cables etc. and getting out in soft/loose soil complete all as specified and directed |
| 2 | Excavation in soft /loose soil in trenches not exceeding 1.5 mtr wide and exceeding 1.5 mtr in depth but not exceeding 3.0 mtr in depth and getting out complete all as specified and directed |
| 3 | Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified and directed |
| 4 | Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed |
| 5 | M&L for sand cushioning to under ground cable in trenches in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable and punned the sand for protection of cable complete all as specified and directedNote:- For payment punned thickness shall be measured and paid. |
| 6 | Supply and laying reinforced precast concrete cable cover class LV type 1 flat size 250mm x 150mm x 40mm complete all as specified and directed |
| 7 | Supplying, laying or fixing or passing through pipe, testing and commissioning XLPE insulated, steel tape / wire armoured heavy duty electric underground cable, 1100 volts grade with stranded aluminium conductor of following nominal cross sectional area including taking down old unserviceable cable:-Note:- Excavation, returning and removal shall be paid and measured seperately under respective item of BOQ |
| 8 | 10 Sqmm 4.0 core. |
| 9 | 16 Sqmm 4.0 core. |
| 10 | 25 Sqmm 3.5 core. |
| 11 | 35 Sqmm 3.5 core. |
| 12 | 50 Sqmm 3.5 core. |
| 13 | 70 Sqmm 3.5 core. |
| 14 | 95 Sqmm 3.5 core. |
| 15 | 120 Sqmm 3.5 core. |
| 16 | Supply and laying in replacement of GI Pipe light grade with all fitting and fixed complete to walls/ poles/underpass and ceilings or laid in floors complete all as specified and directed of following sizes :- |
| 17 | 40 mm bore |
| 18 | 50 mm bore |
| 19 | 80 mm bore |
| 20 | Supply and erecting in replacement of steel tubular swaged pole with cast iron base plate, finial taper plug, bolts, nuts & washers as per IS 2713 (Part-II) 1980 made out of mild steel tubing, type 410 SP-31 (9 metre long) including painting of poles with one coat of red oxide primer and two coat of aluminum paint (one coat before fixing and one coat of aluminum paint after fixing) over exposed surface and two coats of bituminous paint over embedded portion & the portion above coping shall be painted in alternative bands of black and yellow colour starting with white colour (each band of 30cm wide) by two coats of super enameled paint upto 1.5m height complete all as specified and directed. Note : Earth work and PCC shall be measured and paid for separately. |
| 21 | Supply and erecting in replacement of steel tubular swan nacked pole with cast iron base plate, finial taper plug, bolts, nuts & washers made out of mild steel tubing, type 410 SP-31 (9 metre long) including painting of poles with one coat of red oxide primer and two coat of aluminum paint (one coat before fixing and one coat of aluminum paint after fixing) over exposed surface and two coats of bituminous paint over embedded portion & the portion above coping shall be painted in alternative bands of black and yellow colour starting with white colour (each band of 30cm wide) by two coats of super enameled paint upto 1.5m height complete all as specified and directed. Note : Earth work and PCC shall be measured and paid for separately. |
| 22 | M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 23 | M&L for PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation complete all as specified and directed. |
| 24 | M&L for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate for coping around poles including nacessary form fork finishing even without using extra cement complete all as specified and directed. |
| 25 | Cutting wild grass, bushes, creeper, unwanted vegetation from inside / surrounding of E/M sub station (transformers) including cutting creepers from barbed / cattle fencing of the sub stn of area not exceeding 300 Sqm as when directed and removing of unwanted material from installation fencing/ compound and depositing where directed after taking proper electric shutdown form MRS Mathura.Note :- (i) The item shall be operated maximum two times in entire period of contract in the same installations.(ii) Area measured separately each time. |
| 26 | Labour & tools for trimming tree branches upto 100 mm girth of any location around existing HT/LT OH lines giving clearance of 1.5 m on all sides complete all as specified and directed.Note:- Trimming of tree branches irrespective in numbers in each tree shall be measured as one unit. |
| 27 | Supply, installing, commissioning and testing in replacement of LT out door panel board kiosk type (factory made of approved CPRI) made out CRCA sheet 3.15 mm thick,inner sheet 2.0 mm thick, dust and vermin proof and angle iron of suitable size, pedestal flame grouted in PCC (1:2:4) type B-1 20 mm graded stone aggregated thimble and cable entry boxes with cable glands including busbar chamber and water proof duly supported on 40x40x6 mm angle iron frame, opening arrengement from front and rear both duly fitted with comprising cable gland for entry & exit of cable having minimum clearance of 450mm above groung level complete comprising of the following:(a) Panel mounted multi function for voltage, current, frequency, power factor - 01 Set(b) Aluminium bus bar 03 Nos for phase of capacity 500 Amp and 01 Nos 500 Amp for neutral duly taped in colour coded FRP sleeves.(c) LED indicating lamp red, yellow and blue complete with lamp holdes, 220 volta AC- 01 set of 03(d) Panel wiring with 2.5 sqmm PVC sheathed, PVC insulated FRLSH standed copper conductor cable through MCB DP 10 Amp mounted on DIN rail.(e) 4 Pole MCCB 350 Amp, 36 KA -01 Nos incommer(f) 3 Pole MCCB 125 Amp, 36 KA - 02 Nos outgoing(g) 3 Pole MCCB 63 Amp, 16 KA - 04 Nos outgoing |
| 28 | Supply, installing, commissioning and testing in replacement of LT out door panel board kiosk type (factory made of approved CPRI) made out CRCA sheet 3.15 mm thick,inner sheet 2.0 mm thick, dust and vermin proof and angle iron of suitable size, pedestal flame grouted in PCC (1:2:4) type B-1 20 mm graded stone aggregated thimble and cable entry boxes with cable glands including busbar chamber and water proof duly supported on 40x40x6 mm angle iron frame, opening arrengement from front and rear both duly fitted with comprising cable gland for entry & exit of cable having minimum clearance of 450mm above groung level complete comprising of the following:-(a) Panel mounted multi function for voltage, current, frequency, power factor - 01 Set (b) Aluminium bus bar 03 Nos for phase of capacity 500 Amp and 01 Nos 500 Amp for neutral duly taped in colour coded FRP sleeves.(c) LED indicating lamp red, yellow and blue complete with lamp holdes, 220 volta AC - 01 set of 03(d) Panel wiring with 2.5 sqmm PVC sheathed, PVC insulated FRLSH standed copper conductor cable through MCB DP 10A mounted on DIN rail.(e) 4 Pole MCCB 400 Amp, 36 KA -01 Nos incommer(f) 3 Pole MCCB 160 Amp, 25 KA -02 Nos outgoing(g) 3 Pole MCCB 125 Amp, 25 KA -02 Nos outgoing(h) 3 Pole MCCB 63 Amp, 16 KA - 02 Nos outgoing |
| 29 | Supply, installing, commissioning and testing in replacement of LT out door panel board kiosk type (factory made of approved CPRI) made out CRCA sheet 3.15 mm thick,inner sheet 2.0mm thick, dust and vermin proof and angle iron of suitable size, pedestal flame grouted in PCC (1:2:4) type B-1 20 mm graded stone aggregated thimble and cable entry boxes with cable glands including busbar chamber and water proof duly supported on 40x40x6 mm angle iron frame, opening arrengement from front and rear both duly fitted with comprising cable gland for entry & exit of cable having minimum clearance of 450mm above groung level complete comprising of the following:(a) Panel mounted multi function for voltage, current, frequency, power factor - 01 Set(b) Aluminium bus bar 03 Nos for phase of capacity 500 Amp and 01 Nos 500 Amp for neutral duly taped in colour coded FRP sleeves.(c) LED indicating lamp red, yellow and blue complete with lamp holdes, 220 volta AC- 01 set of 03(d) Panel wiring with 2.5 sqmm PVC sheathed, PVC insulated FRLSH standed copper conductor cable through MCB DP 10A mounted on DIN rail.(e) 4 Pole MCCB 630 Amp, 36 KA -01 Nos incommer(f) 3 Pole MCCB 350 Amp, 35 KA - 01 Nos outgoing(g) 3 Pole MCCB 250 Amp, 35 KA -01 Nos outgoing |
| 30 | Supply, installing, commissioning and testing in replacement of LT out door panel board kiosk type (factory made of approved CPRI) made out CRCA sheet 3.15 mm thick,inner sheet 2.0 mm thick, dust and vermin proof and angle iron of suitable size, pedestal flame grouted in PCC (1:2:4) type B-1 20 mm graded stone aggregated thimble and cable entry boxes with cable glands including busbar chamber and water proof duly supported on 40x40x6 mm angle iron frame, opening arrengement from front and rear both duly fitted with comprising cable gland for entry & exit of cable having minimum clearance of 450mm above groung level complete comprising of the following:-(a) Panel mounted multi function for voltage, current, frequency, power factor - 01 Set(b) Aluminium bus bar 03 Nos for phase of capacity 500 Amp and 01 Nos 500 Amp for neutral duly taped in colour coded FRP sleeves. (c) LED indicating lamp red, yellow and blue complete with lamp holdes, 220 volta AC- 01 set of 03(d) Panel wiring with 2.5 sqmm PVC sheathed, PVC insulated FRLSH standed copper conductor cable through MCB DP 10 Amp mounted on DIN rail.(e) 4 Pole MCCB 630 Amp, 36 KA -01 Nos incommer(f) 3 Pole MCCB 250 Amp, 25 KA - 02 Nos outgoing(g) 3 Pole MCCB 125 Amp, 25 KA - 01 Nos outgoing(h) 3 Pole MCCB 100 Amp, 16 KA - 01 Nos outgoing |
| 31 | Supply and fixing in replacement of MCCB 250 Amp rating, 4-Pole 415 Volt, adjustable thermal adjustable magnetic type breaking capacity 36 kA complete all as specified and directed. |
| 32 | Supply and fixing in replacement of MCCB 200 Amp rating, 4-Pole 415 Volt, adjustable thermal adjustable megnetic type breaking capacity 36 kA complete all as specified and directed. |
| 33 | Supply and fixing in replacement of MCCB 160 Amp rating, 4-Pole 415 Volt, adjustable thermal adjustable megnetic type breaking capacity 16 kA complete all as specified and directed. |
| 34 | Supply and fixing in replacement of MCCB 100 Amp rating, 4-Pole 415 Volt, adjustable thermal adjustable megnetic type adjustable thermal adjustable megnetic type breaking capacity 16 kA complete all as specified and directed. |
| 35 | Supply and fixing in replacement of MCCB 63 Amp rating, 4-Pole 415 Volt, adjustable thermal adjustable megnetic type adjustable thermal fixed megnetic type breaking capacity 16 kA complete all as specified and directed. |
| 36 | supply and fixing in replacement of LED street light fitting 70 watt 230 Volt AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver lamp bracket with impect and corrosion resistant including thermal megnetic in multiple optic complete with IP 65/66 protection complete all as specified and directed. |
| 37 | Supply and fixing in replacement of LED flood light fitting 120 watt 230 Volt, AC outdoor type with thermal megnetic in multiple optic and equipped with IP 66 protection with impect and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 38 | Supply and fixing in replacement of LED flood light fitting 150 watt 230 Volt, AC outdoor type with thermal megnetic in multiple optic and equipped with IP 66 protection with impect and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 39 | Supply and fixing in replacement of LED bollard flarefitted with low glare diffuser 12 with integrated driver with uniform light distribution complete all as specified and directed. |
| 40 | Supply and fixing in replacement of post top laltern LED type 30 watt 230 Volt AC outdoor type with decorative post top for 360 degree indirect light with IP 66 protection with impect and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 41 | Excavation in post hole (or similar hole) each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed. |
| 42 | Supply only chain link fencing made out of mild steel galvanised wire of any size complete all as specified and directed. |
| 43 | Fixing only chain link fencing including line wires, any mesh, sizes and type to any type of strandards, rail, straining bolts etc including provision of binding wire complete all as specified and directed.Note:- (i) Supply only chain link fencing will be measured and paid separately.(ii) Supply and fixing mild steel nut bolt, line wire and flat iron will be measured and paid separately. |
| 44 | Supply and fixing mild steel section in post and struts for fencing including cutting top to shape as directed drilling hole notching for wire etc or flat iron fillet (for security wire mesh etc) including all necessary drilling bolting or riverting etc complete all as specified and directed. |
| 45 | Supply and fixing Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends,each screwed end to be fitted with washers and one hexagonal or square nut, not exc 5 cm long & dia of shank 11 to 15 mm complete all as specified and directed. |
| 46 | M&L for Preparation of new steel surfaces of any description over 10 cm width or girth, not otherwise desenbed and applying two coats of synthetic enamel paint over a coat of zinc chromate primer complete all as specified and directed. |
| 47 | Supply & fixing cable jointing kit for 1.1 KV grade cable for straight through joint heat shrinkable type complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm including taking down old unserviceable joint kit complete all as specified and directed. |
| 48 | Supply & fixing cable jointing kit for 1.1 KV grade cable for straight through joint heat shrinkable type complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm including taking down old unserviceable joint kit complete all as specified and directed. |
| 49 | M&L for GI strip of size 32x6mm as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle including taking down old unserviceable rusted strip any type and size complete all as specified and directed. |
| 50 | M&L for copper strip of size 32x6mm as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle including taking down old unserviceable rusted strip any type and size complete all as specified and directed. Note :- cost of insulating saddle for fixing of copper strip on wall/ roof/ floor etc is including in quotated rates complete all as specified and directed. |
| 51 | M&L for earthing complete with galvanised steel earth plate electrode 60cmX60cmX6.0mm thick, buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not than 1.5mtr below normal ground level connected to GI earth strip of size 32x6mm dia by means of bolts, nuts, check nuts and washers of galvanised iron complete earth pit of PCC M-10(Nominal mix) using 20mm graded stone aggregate, 50mm thick earth pit cover of RCC M-15 (Nominal mix) using 20mm graded stone aggregate with MS TMT reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape, PGI funnel, wire mesh and 20mm bore GI water pipe medium grade and 40mm bore medium grade GI pipe for protection of earth strip from plate to main panel/eqpmt, pole/bus bar etc, common salt, charcoal dust including testing on completion complete all as specified and as directed all as shown in electrical plate No. 3 including testing on completion and making good the disturbed surfaces of wall floors etc without claiming extra cost including taking down old unserviceable earthing complete all as specified and directed.Note: GI strip beyond 7.5 metre length from earth electrode shall be measured and paid separately. |
| 52 | All as per serial item No. 40.00 here-in-before but earthing with 4 mm dia GI wire complete all as specified and directed. Please Enable Macros to View BoQ information |